Wilo Motor T 17.3, 20.2:
EMU FA, Rexa SUPRA, Rexa SOLID
6086016 • Ed.01/2019-10
zh-CHS 安装及操作说明 en Installation and operating instructions


3
Chinese (simplified).......................................................................................... 4
English ............................................................................................................... 49

zh-CHS
4 WILO SE 2019-10
目录
1 概述 ............................................................................................................................................................................................ 6
1.1 关于本说明书 ....................................................................................................................................................................................................6
1.2 版权 .....................................................................................................................................................................................................................6
1.3 保留更改权力 ....................................................................................................................................................................................................6
1.4 保修和免责声明................................................................................................................................................................................................6
2 安全 ............................................................................................................................................................................................ 6
2.1 安全说明的标识................................................................................................................................................................................................6
2.2 工作人员资格鉴定............................................................................................................................................................................................8
2.3 电气作业.............................................................................................................................................................................................................8
2.4 监控装置.............................................................................................................................................................................................................8
2.5 在危害健康的介质内使用...............................................................................................................................................................................8
2.6 永磁电机.............................................................................................................................................................................................................8
2.7 运输 .....................................................................................................................................................................................................................9
2.8 安装/拆卸工作...................................................................................................................................................................................................9
2.9 运行期间.............................................................................................................................................................................................................9
2.10 维护工作.............................................................................................................................................................................................................9
2.11 工作介质.......................................................................................................................................................................................................... 10
2.12 运营者的责任 ................................................................................................................................................................................................. 10
3 应用/使用................................................................................................................................................................................. 10
3.1 规定用途.......................................................................................................................................................................................................... 10
3.2 未按规定使用 ................................................................................................................................................................................................. 10
4 产品说明 .................................................................................................................................................................................. 11
4.1 结构 .................................................................................................................................................................................................................. 11
4.2 Digital Data Interface ..................................................................................................................................................................................... 12
4.3 监控设备.......................................................................................................................................................................................................... 12
4.4 运行模式.......................................................................................................................................................................................................... 13
4.5 使用变频器运行 ............................................................................................................................................................................................. 14
4.6 在易爆环境中运行......................................................................................................................................................................................... 14
4.7 铭牌 .................................................................................................................................................................................................................. 14
4.8 型号代码.......................................................................................................................................................................................................... 15
4.9 供货范围.......................................................................................................................................................................................................... 16
4.10 附件 .................................................................................................................................................................................................................. 17
5 运输和存放.............................................................................................................................................................................. 17
5.1 交货 .................................................................................................................................................................................................................. 17
5.2 运输 .................................................................................................................................................................................................................. 17
5.3 存放 .................................................................................................................................................................................................................. 18
6 安装及电气连接...................................................................................................................................................................... 18
6.1 工作人员资格鉴定......................................................................................................................................................................................... 18
6.2 安装方式.......................................................................................................................................................................................................... 18
6.3 运营者的责任 ................................................................................................................................................................................................. 18
6.4 安装 .................................................................................................................................................................................................................. 19
6.5 电气连接.......................................................................................................................................................................................................... 24
7 试运行 ...................................................................................................................................................................................... 29
7.1 工作人员资格鉴定......................................................................................................................................................................................... 29
7.2 运营者的责任 ................................................................................................................................................................................................. 29
7.3 旋转方向监控(仅限三相交流电机) ...................................................................................................................................................... 29
7.4 在易爆环境中运行......................................................................................................................................................................................... 30
7.5 接通前 .............................................................................................................................................................................................................. 30
7.6 接通和关闭...................................................................................................................................................................................................... 31
7.7 运行期间.......................................................................................................................................................................................................... 31
8 停止运行/拆卸......................................................................................................................................................................... 32
8.1 工作人员资格鉴定......................................................................................................................................................................................... 32
8.2 运营者的责任 ................................................................................................................................................................................................. 32

zh-CHS
安装及操作说明 Wilo Motor T 17.3, 20.2:#EMU FA, Rexa SUPRA, Rexa SOLID 5
8.3 停止运行.......................................................................................................................................................................................................... 32
8.4 拆卸 .................................................................................................................................................................................................................. 32
9 维护和维修.............................................................................................................................................................................. 34
9.1 工作人员资格鉴定......................................................................................................................................................................................... 34
9.2 运营者的责任 ................................................................................................................................................................................................. 35
9.3 工作介质.......................................................................................................................................................................................................... 35
9.4 维护间隔.......................................................................................................................................................................................................... 35
9.5 维护措施.......................................................................................................................................................................................................... 36
9.6 维修工作.......................................................................................................................................................................................................... 39
10 故障、原因和排除方法.......................................................................................................................................................... 41
11 备件 .......................................................................................................................................................................................... 44
12 废弃处置 .................................................................................................................................................................................. 44
12.1 油和润滑剂...................................................................................................................................................................................................... 44
12.2 防护服 .............................................................................................................................................................................................................. 44
12.3 关于收集损耗的电气产品和电子产品的相关信息................................................................................................................................. 44
13 防爆认证 .................................................................................................................................................................................. 44
13.1 获得防爆认证的水泵标识............................................................................................................................................................................ 44
13.2 防护等级.......................................................................................................................................................................................................... 44
13.3 规定用途.......................................................................................................................................................................................................... 45
13.4 电气连接.......................................................................................................................................................................................................... 45
13.5 试运行 .............................................................................................................................................................................................................. 47
13.6 维护和维修...................................................................................................................................................................................................... 47
14 附件 .......................................................................................................................................................................................... 47
14.1 拧紧扭矩.......................................................................................................................................................................................................... 47
14.2 在变频器上运行 ............................................................................................................................................................................................. 48

zh-CHS 概述
6 WILO SE 2019-10
1 概述
1.1 关于本说明书 本说明书是产品的固定组成部分。遵守本说明书中列出的要求和操作步骤,是按规
定使用及正确操作产品的前提条件:
ƒ在执行所有工作前或使用产品前请仔细阅读本说明书。
ƒ请妥善保管说明书,以备随时使用。
ƒ另外注意遵守产品上标注的所有产品相关参数和标识。
原版操作说明书以德语撰写。所有其它语种的说明书均为其翻译件。
1.2 版权 本说明书的版权归Wilo所有。所有内容禁止以任何形式:
ƒ翻版。
ƒ传播。
ƒ出于竞争目的非法使用。
Wilo保留更改所述数据的权利,恕不另行通知,对于技术性描述不准确和/或遗漏不
承担任何责任。
1.3 保留更改权力 Wilo保留对产品以及单个部件进行技术变更的权利。说明书中使用的图片可能与实
际设备存在偏差,仅用于举例介绍产品。
1.4 保修和免责声明 Wilo对于如下情况,不承担任何保修义务或责任:
ƒ由于运营者或委托方提供的数据存在缺陷或者错误,导致出现配置欠缺问题
ƒ不遵守本说明书的内容
ƒ未按规定使用
ƒ不按规范存放或运输
ƒ错误安装或拆卸
ƒ缺乏维护
ƒ无授权维修
ƒ安装基础有缺陷
ƒ化学、电气或电化学影响
ƒ磨损
2 安全 本章节主要介绍各生命阶段适用的基础提示信息。不遵守提示会导致下列危险:
ƒ电气、机械和细菌作用以及电磁场危害人身安全
ƒ有害物质泄漏会污染环境
ƒ物资损失
ƒ产品重要功能失灵
不遵守提示信息会导致丧失索赔权利。
此外也应遵守其他章节列出的各项指导说明和安全说明!
2.1 安全说明的标识 本安装及操作说明针对物资损失和人身安全问题列举了多项安全说明。其表现形式
各有不同:
ƒ涉及到人身安全问题的安全说明以一个信号词作为开端,配套使用相应的符号
并使用灰色作为背景色。
危险
危险类型和危险源!
危险产生的影响以及避免危险说明。
ƒ涉及到物资损失问题的安全说明也以一个信号词作为开端,但是没有符号。
小心
危险类型和危险源!
影响或信息。
信号词
ƒ危险!
如不注意,会导致死亡或重伤!

安全 zh-CHS
安装及操作说明 Wilo Motor T 17.3, 20.2:, EMU FA, Rexa SUPRA, Rexa SOLID 7
ƒ警告!
如不注意,可能导致人员受伤(重伤)!
ƒ小心!
如不遵守,可能造成物资损失,甚至导致全损。
ƒ提示!
操作产品时有用的注意事项
文本说明
‡前提条件
1. 操作步骤/细目列举
⇒ 提示/指导
▶ 结果
图标
在本说明书中使用以下图标:
电击危险
细菌感染危险
强磁场危险
爆炸危险
爆炸气体导致危险
一般警告图标
切割受伤警告
高温表面警告
高压警告
悬挂物警告
个人防护装备:戴安全头盔
个人防护装备:穿劳保鞋
个人防护装备:戴防护手套
个人防护装备:佩戴口罩

zh-CHS 安全
8 WILO SE 2019-10
个人防护装备:戴护目镜
禁止独自工作!必须两人在场。
实用注意事项
2.2 工作人员资格鉴定 工作人员必须:
ƒ了解当地现行的事故预防条例。
ƒ已阅读安装及操作说明书并且理解其中内容。
工作人员必须具备下列资质:
ƒ电气作业:电气作业必须由专业电工执行。
ƒ安装/拆卸工作:必须由专业人员执行,而且要求该人员接受过相关培训,了解
工作中会用到的工具以及当前施工现场需要使用的固定材料。
ƒ保养工作:必须由熟悉所使用工作介质及其废弃处置的专业人员执行。此外工
作人员还必须具有机械制造方面的基础知识。
“专业电工”定义
所谓“专业电工”,是指接受过相关培训,具备所需知识和经验,能够发现并且规避
电力危险的人员。
2.3 电气作业 ƒ电气作业由专业电工负责执行。
ƒ在对产品开始任何作业之前,都应先将其断电并采取措施防止重新接通。
ƒ通电时注意遵守当地相关法规。
ƒ注意遵守当地供电公司的相关规定。
ƒ将电气连接方式等知识告知相关人员。
ƒ告知相关人员如何关闭产品。
ƒ遵守本安装及操作说明以及铭牌上给出的技术参数。
ƒ将产品接地。
ƒ遵守电气开关设备连接规定。
ƒ如果使用启动控制器(比如软启动或变频器等),注意遵守电磁兼容性规定。
如果需要,考虑采取专业措施(比如使用屏蔽电缆和滤波器等)。
ƒ更换损坏的接线电缆。请咨询客户服务部。
2.4 监控装置 安装方必须准备下列监控设备:
断路器
断路器的规格和开关属性取决于所连接产品的额定电流。注意遵守当地相关法规。
电机保护开关
对于不带插头的产品,安装方应该准备一个电机保护开关!最低要求是配备一个符
合本地规定,具备温度补偿、差分触发和重启锁定功能的热敏继电器/电机保护开
关。针对反应灵敏的电网,安装方还应准备其他保护装置(比如超压、欠压或缺相
继电器等)。
漏电断路器 (RCD)
遵守当地供电公司的相关规定!建议使用漏电断路器。
如果人员可能接触到产品和导电液体,需要对电路连接采取安全措施,装备一个漏
电断路器 (RCD)。
2.5 在危害健康的介质内使用 如果在危害健康的介质内使用产品,可能导致细菌感染危险!拆下之后,以及再次
使用之前,应该彻底清洁产品并进行消毒。运营者必须注意以下几点:
ƒ进行产品清洁时,提供下列防护装备供工作人员使用:
–封闭式护目镜
–氧气面罩
–防护手套
ƒ告知所有工作人员,流体会导致危险,并普及正确的流体处理方法!
2.6 永磁电机 通过永磁转子驱动永磁电机。在使用永磁电机时请注意以下几点:

安全 zh-CHS
安装及操作说明 Wilo Motor T 17.3, 20.2:, EMU FA, Rexa SUPRA, Rexa SOLID 9
ƒ磁铁和磁场
如果关闭电机外壳,磁铁和磁场不会产生危险。对于佩戴心脏起搏器的人同样
不会构成特殊危险。在保养时可毫无顾忌地打开螺旋塞。绝对不能打开电机外
壳!只有客户服务部可以在打开的电机上作业!
ƒ发电机运行模式
如果在没有电能情况下驱动转子(比如在流体回流时),电机会产生感应电
压。这时接线电缆会通电。另外在连接有水泵时,会向连接的变频器馈能。为
避免因过电压损坏变频器和电机,设计了以下方案:
–向供电网反馈传入的能量。
–通过制动电阻导出传入的能量。
2.7 运输 ƒ穿戴以下防护装备:
–安全鞋
–安全头盔(使用提升设备的情况下)
ƒ运输产品时始终抓住把手。不得拉扯接线电缆!
ƒ只使用合法且获得认证的提升装置。
ƒ根据实际情况(天气、接合点、负载等)选择提升装置。
ƒ始终把提升装置固定在接合点(把手或吊孔)上。
ƒ使用期间必须保证提升设备稳定可靠。
ƒ使用提升设备时,如果需要(比如视线受阻),安排另外一位工作人员负责协
调。
ƒ切勿在悬挂物下停留。悬挂物切勿从有人员停留的工作位置上方经过。
2.8 安装/拆卸工作 ƒ穿戴以下防护装备:
–安全鞋
–安全手套,用以预防切割伤害
–安全头盔(使用提升设备的情况下)
ƒ遵从当地有关作业安全和事故防范措施的现行法律法规。
ƒ将产品断电并采取安全措施防止意外接通。
ƒ所有旋转零部件均须保持静止。
ƒ在封闭的空间内需提供足够的通风条件。
ƒ在集水坑和封闭空间内作业时,为安全起见,必须有第二个人在场。
ƒ如果出现有毒气体或窒息气体汇集的情况,立刻采取对策!
ƒ彻底清洁产品。如果在危害健康的流体内使用过产品,请消毒!
ƒ进行所有焊接作业或使用电气装置工作时,确保不存在爆炸风险。
2.9 运行期间 ƒ穿戴以下防护装备:
–安全鞋
–耳罩(遵循工作规程的相关通知)
ƒ产品工作区域不是人员停留区。在产品运行期间,禁止任何人在工作区域内停
留。
ƒ通过单独的控制器根据流程接通和断开产品。在停电之后,可自动接通产品。
ƒ一旦发生故障或者出现异常,操作人员必须立即报告主管。
ƒ一旦出现危及人身安全的缺陷,操作人员必须立刻关闭设备:
–安全和监控设备故障
–外壳部件损坏
–电气装置损坏
ƒ切勿探入吸水口中。旋转的部件可能会对身体造成挤伤或割伤。
ƒ如果电机在运行过程中浮出水面,电机外壳温度可能超过 40°C (104°F)。
ƒ打开入口侧和出口侧管路中的所有截止阀。
ƒ通过干转保护确保不会低于最低水浸。
ƒ在一般工作条件下,产品的噪声低于 85dB(A)。但是实际发出的噪声受多种因素
影响:
–安装深度
–安装
–附件和管路固定件
–工况点
–潜水深度
ƒ如果产品在有效的工作条件下运行,则运营者方面必须执行声压测量。声压超
过 85dB(A) 时,佩戴耳罩并标识工作区域!
2.10 维护工作 ƒ穿戴以下防护装备:
–封闭式护目镜
–安全鞋
–安全手套,用以预防切割伤害
ƒ始终在运行空间/安装地点以外执行维护工作。

zh-CHS 应用/使用
10 WILO SE 2019-10
ƒ只执行本安装及操作说明中列出的维护工作。
ƒ进行维护和维修时,只能使用生产商提供的原装部件。由于使用非原装部件而
造成的任何损失,生产商概不承担任何责任。
ƒ一旦发生流体和工作介质泄露事故,立即收集泄漏物并按照当地现行法规进行
废弃处理。
ƒ将工具保管在指定位置。
ƒ工作结束后,重新安装所有安全和监控设备,并检查其功能是否正确。
更换工作介质
一旦发生损坏,电机内可能形成高达数巴的压力!打开螺旋塞时,这种压力会向外
冲出。如果打开螺旋塞时不注意,它可能会高速弹出!请始终遵守以下指示,避免
受伤:
ƒ遵守规定的工作步骤顺序。
ƒ缓慢转动螺旋塞,不要完全拧出。开始泄压之后(可听见空气鸣叫声或嘶嘶
声),不要继续转动螺旋塞。
警告!泄压时可能喷出高温工作介质,会导致烫伤!为了避免受伤,执行任何
作业之前,都应先将电机冷却到环境温度!
ƒ待泄压完成之后,完全拧出螺旋塞。
2.11 工作介质 电机密封室内注有白油。定期维护时必须更换工作介质,之后按照本地相关法规进
行废弃处置。
2.12 运营者的责任 ƒ为工作人员提供以其母语写成的安装及操作说明。
ƒ为工作人员提供必要的培训,确保其能胜任指派的工作。
ƒ提供必要的防护装备并保证工作人员佩戴防护装备。
ƒ使产品上安装的安全和提示标牌长期保持清晰可读状态。
ƒ使工作人员了解设备的功能原理。
ƒ杜绝电流导致危险。
ƒ为设备中的危险部件装备触摸防护装置(安装方提供)。
ƒ标记工作区并采取安全措施。
ƒ为工作人员指定工作范围,保证安全作业。
禁止儿童和 16 岁以下或身体、感官或精神上能力不足的人员处理该产品!18 岁以
下人员必须由专业人员监督!
3 应用/使用
3.1 规定用途 潜水泵适用于泵送:
ƒ含有粪便的污水
ƒ污水(含少量沙子和砂砾)
ƒ工艺污水
ƒ干物质所占比例不超过 8% 的流体
3.2 未按规定使用
危险
输送爆炸性流体会导致爆炸!
严禁输送纯粹形态下的易燃易爆流体(汽油、煤油等)。爆炸导致生命危险!
水泵不是针对这类流体设计出的产品。
危险
危害健康的流体会导致危险!
如果在危害健康的流体中使用过水泵,则拆卸水泵后必须进行消毒处理,之后
才能用于其他工作!有生命危险!遵守工作规程的相关规定!运营者必须保证
工作人员已经收到并阅读工作规程!
潜水泵不得用于泵送以下流体:
ƒ饮用水
ƒ混杂硬物(比如石头、木头、金属等)的流体
ƒ含有大量磨蚀性物质(比如沙子、砂砾等)的流体。
符合规定的使用还包括遵守本说明的规定。任何超出规定范围的应用均视为不合规
定。

产品说明 zh-CHS
安装及操作说明 Wilo Motor T 17.3, 20.2:, EMU FA, Rexa SUPRA, Rexa SOLID 11
4 产品说明
4.1 结构 污水潜水泵作为潜水式整装机组,适用于湿井安装和干式地坑安装。
Y
X
Z
1
2
3
4
5
6
7
8
Fig.1: 示意图
1 进线接线电缆
2 电机
3 密封壳体/轴承箱体
4 出水口
5 吸水口
6 水力部件外壳
7 吊装孔/把手
8 坐标系:Digital Data Interface中的振动传感器
4.1.1 水力部件 离心式水力部件配备不同形式的叶轮、出口侧水平法兰接口以及泵体密封环和叶轮
耐磨环。
水力部件不是自吸式产品,即流体必须自动流入或者在一定的供给压力下流入。
叶轮形式
叶轮形式取决于叶轮规格,不是所有叶轮形状都适合所有水力部件。下文概述介绍
各种叶轮形式:
ƒ涡流叶轮
ƒ单通道叶轮
ƒ双流道叶轮
ƒ三通道叶轮
ƒ四通道叶轮
ƒSOLID 叶轮,封闭或半开
泵体密封环和叶轮耐磨环(取决于水力部件)
吸水口和叶轮在泵送过程中大多承受负荷。如果装备通道叶轮,则叶轮和吸水口之
间的间隙是保持恒定效率的重要因素。叶轮和吸水口之间的间隙越大,输出量的损
耗就越高。这样会降低效率,发生堵塞的危险提高。为了确保水力部件能够长期高
效运行,视装备的叶轮和水力部件而定,设备装有一个叶轮耐磨环和/或泵体密封
环。
ƒ叶轮耐磨环
叶轮耐磨环安装在通道叶轮上,保护叶轮的入流边。
ƒ泵体密封环
泵体密封环安装在水力部件的吸水口中,保护通向离心室的入流边。
在磨损时,客户服务部可方便地更换两个部件。
4.1.2 电机 三相交流电规格的表面冷却型异步或永磁电机。通过周围的流体进行冷却。余热通
过电机外壳直接排放到流体或周围空气中。电机可以在运行过程中露出液面,可以
干式地坑安装。注意!为预防在干式地坑安装中电机过热,必须调整功率和接通
时间!接线电缆有裸线端。
电机装备概述
异步电动机 永磁电机
T20.2 T17.3...-P T20.2...-P
类型 异步 同步 同步
最高效率等级(根据 IEC 60034) IE3 IE5 IE5
使用变频器运行 o !(Wilo-EFC) !(Wilo-EFC)
Digital Data Interface o • •
浸入运行模式 S1 S1 S1
非浸入运行模式 S2* S2* S2*
干式地坑安装运行模式 S2* S2* S2*
上方滚动轴承:永久润滑的,维护需求低 • • •

zh-CHS 产品说明
12 WILO SE 2019-10
异步电动机 永磁电机
T20.2 T17.3...-P T20.2...-P
下方滚动轴承:永久润滑的,维护需求低 • • •
纵向防水密封接线电缆 • • •
! = 必要/前提条件, • = 标配,o = 可选,− = 不可用
* 运行时长(单位为分钟)与电机功率有关,参见型号铭牌。
4.1.3 密封件 流体密封件和电机舱密封件类型不同:
ƒ“G”型:两个单独的机械密封
ƒ“K”型:两个机械密封装在一个不锈钢制成的整装密封盒中
如果密封件发生泄漏,液体会进入密封室或泄漏腔:
ƒ密封室接收流体侧密封件泄漏出的液体。
出厂时密封室内注有医用白油。
ƒ泄漏腔接收电机侧密封件泄漏出的液体。
泄漏腔在出厂时是空的。
小心!如果电机未附加装备泄漏腔,电机侧密封件泄露出的液体会进入电机!
密封室和泄漏腔概述
异步电动机 永磁电机
T20.2 T17.3...-P T20.2...-P
密封室 • • •
泄漏腔 • − •
• = 标配,− = 不可用
4.1.4 材料 标准规格使用下列材料:
ƒ水泵壳体:灰口铸铁
ƒ叶轮:灰口铸铁
ƒ电机外壳:灰口铸铁
ƒ电机侧密封件:
–“G”= 碳/陶瓷或 SiC/SiC
–“K”= SiC/SiC
ƒ流体侧密封件:SiC/SiC
ƒ静态密封件:FKM (ASTMD1418) 或 NBR(丁腈橡胶)
所使用材料的精确参数体现在相应的配置中。
4.2 Digital Data Interface
注意
注意Digital Data Interface的说明书!
阅读并遵守有关Digital Data Interface的单独说明书,以了解详细信息和高级设
置。
Digital Data Interface 是一种集成在电机中的通讯模块,包括集成式网络服务器。通
过用户图形界面,借助网络浏览器进行访问。通过用户界面可方便地配置、控制和
监控水泵。为此可在水泵中安装不同的传感器。另外可通过外部控制的信号变送器
将其他设备参数加载到控制装置中。Digital Data Interface 可根据系统模式:
ƒ监控水泵。
ƒ使用变频器控制水泵。
ƒ控制有最多 4 台水泵的完整设备。
4.3 监控设备 监控设备概述
异步电动机 永磁电机
T20.2 T20.2 T17.3...-P T20.2...-P
内部监控设备
Digital Data Interface − • • •

产品说明 zh-CHS
安装及操作说明 Wilo Motor T 17.3, 20.2:, EMU FA, Rexa SUPRA, Rexa SOLID 13
异步电动机 永磁电机
T20.2 T20.2 T17.3...-P T20.2...-P
电机绕组:双金属 • − − −
电机绕组:PTC o • (+ 1...3x Pt100) • (+ 1...3x Pt100) • (+ 1...3x Pt100)
电机轴承:Pt100 o o o o
密封室:电感式传感器 − − − −
密封室:电容式传感器 − • • •
泄漏腔:浮子开关 • − − −
泄漏腔:电容式传感器 − • − •
振动传感器 − • • •
外部监控设备
密封室:电感式传感器 o − − −
• = 标配,− = 不可用,o = 可选
所有现有的监控设备必须始终处于连接状态!
4.3.1 无 Digital Data Interface 的电机 电机绕组监控
电机过热保护可以保护电机绕组免于过热。标准安装带一个双金属片的温度限制装
置。如果达到反应温度,必须使用重启锁定功能执行一次关闭操作。
温度探测装置可以选装一个 PTC 传感器。此外也可将电机过热保护装置用作温度调
节装置。这样就可以探测两个温度。如果达到更低的反应温度,可以在电机冷却后
执行一次自动重启。只有达到高反应温度时,才必须使用重启锁定功能执行一次关
闭操作。
密封室外部监控装置
密封室可以装备一个外部铅芯湿度电极。电极记录通过液体侧机械密封渗入介质的
事件。之后就可以通过水泵控制器生成报警或者关闭水泵。
泄漏腔监控
泄漏腔装有一个浮子开关。浮子开关记录通过电机侧机械密封渗入流体的事件。之
后就可以通过水泵控制器生成报警或者关闭水泵。
电机轴承监控
电机轴承热监控设备保护滚动轴承免于过热。使用 Pt100 传感器记录温度。
4.3.2 有 Digital Data Interface 的电机
注意
注意Digital Data Interface的说明书!
阅读并遵守有关Digital Data Interface的单独说明书,以了解详细信息和高级设
置。
通过 Digital Data Interface 分析所有现有的传感器。通过Digital Data Interface的图形
操作界面显示当前值和设置极限参数。在超过极限参数时会发出警示或警报信息。
为安全关闭水泵,电机绕组另外配备有 PTC 传感器。
4.4 运行模式 运行模式 S1:连续运行
水泵能在额定负荷下连续运行,而不会超过允许的温度。
运行模式:非浸入运行
“非浸入运行”这种运行模式描述电机在水泵运行过程中浮出水面。这时水位可以降
至更低位置,直至达到水力部件上缘。
非浸入运行时注意以下几点:
ƒ已指定“非浸入”运行模式
允许在“非浸入”运行模式下露出电机。
ƒ未指定“非浸入”运行模式

zh-CHS 产品说明
14 WILO SE 2019-10
如果电机配备温度调节装置(双回路温度监控装置),则允许露出电机。电机
冷却后,可以通过低温功能自动重启。只有达到高温时,才必须使用重启锁定
功能执行一次关闭操作。小心!为了保护电机绕组免于过热,必须为电机配备
温度调节装置!如果只装有温度限制装置,则电机不可在运行过程中浮出水
面。
ƒ电机带有集成的Digital Data Interface
不允许电机非浸入运行。通过用户界面在“非浸入运行”功能中规定框架参数。
ƒ最高流体和环境温度:最高环境温度相当于铭牌上标注的最高流体温度。
4.5 使用变频器运行
4.5.1 异步电动机 允许使用变频器运行异步电动机。变频器必须至少有以下接口:
ƒ双金属和 PTC 传感器
ƒ湿度电极
ƒPt100 传感器(如果有电机轴承监控!)
其他要求参考并注意遵守章节“在变频器上运行 [}48]”!
如果电机配备有Digital Data Interface,另外要确保具备以下前提条件:
ƒ网络:Ethernet 10BASE-T/100BASE-TX,基于 IP
ƒ协议支持:Modbus TCI/IP
详细的要求请参考Digital Data Interface的单独说明书!
4.5.2 永磁电机 在运行永磁电机时,确保具备以下前提条件:
ƒ有 PTC 传感器接口的变频器
ƒ网络:Ethernet 10BASE-T/100BASE-TX,基于 IP
ƒ协议支持:Modbus TCI/IP
详细的要求请参考Digital Data Interface的单独说明书!
永磁电机允许使用以下变频器运行:
ƒWilo-EFC
其他变频器敬请垂询!
4.6 在易爆环境中运行
异步电动机 永磁电机
T 20.2 T 17.3...-P T 20.2...-P
经 IEC-Ex 批准 o o o
经 ATEX 批准 o o o
经 FM 批准 o o o
经 CSA-Ex 批准 − − −
图例
− = 不存在/不可能,o = 可选,• = 标配
在爆炸性气体中使用时,水泵铭牌上必须具有下列标识:
ƒ相应认证的防爆标识
ƒ防爆等级
关于防爆电缆的相关要求,参见本操作说明书的附录,并注意遵守要求!
ATEX 认证
水泵适合在潜在爆炸环境中运行:
ƒ设备组:II
ƒ类别:2,1 区和 2 区
水泵不可在 0 区使用!
FM 认证
水泵适合在潜在爆炸环境中运行:
ƒ防护等级:Explosionproof
ƒ类别:Class I,Division 1
注意:如果根据 Division 1 布线,则也允许在 Class I, Division 2 中安装。
4.7 铭牌 下面概述介绍铭牌上的缩写词和相关数据:

产品说明 zh-CHS
安装及操作说明 Wilo Motor T 17.3, 20.2:, EMU FA, Rexa SUPRA, Rexa SOLID 15
铭牌缩写词 含义
P-Typ 水泵类型
M-Typ 电机类型
S/N 序列号
Art.-No. 商品号
MFY 生产日期*
QN工况点流量
Qmax 最大流量
HN工况点扬程
Hmax 最大扬程
Hmin 最小扬程
n转速
T流体最高温度
IP 防护等级
I额定电流
IST 启动电流
ISF 服务因数下的额定电流
P1功耗
P2额定功率
U额定电压
UEMF 感应电压
f频率
fop 最高工作频率
Cos φ 电机效率
SF 服务因数
OTS运行模式:浸入式
OTE运行模式:非浸入式
AT 启动方式
IM org 叶轮直径:初始
IM korr 叶轮直径:修正后
*生产日期书写格式符合 ISO8601 标准:JJJJWww
ƒJJJJ = 年份
ƒW = 周缩写词
ƒww = 日历周数据
4.8 型号代码 各个水力部件之间的型号代码不同。下面展示各个型号代码。
4.8.1 水力部件型号代码:EMU FA 示例:Wilo-EMU FA 15.52-245E
FA 污水泵
15 x10 = 压力连接公称直径
52 内部功率因数
245 叶轮初始直径
(仅限标准型号,经过配置的水泵不适用)
D
叶轮形式:
W = 涡流叶轮
E = 单通道叶轮
Z = 双流道叶轮
D = 三通道叶轮
V = 四通道叶轮
T = 闭式双流道叶轮
G = 半开式单通道叶轮

zh-CHS 产品说明
16 WILO SE 2019-10
4.8.2 水力部件型号代码:Rexa SUPRA 示例:Wilo-Rexa SUPRA-V10-736A
SUPRA 污水泵
V
叶轮形式:
V = 涡流叶轮
C = 单通道叶轮
M = 多通道叶轮
10 x10 = 压力连接公称直径
73 内部功率因数
6特征曲线编号
A
材料规格:
A = 标准规格
B = 防腐 1
D = 防磨 1
X = 特殊规格
4.8.3 水力部件型号代码:Rexa SOLID 示例:Wilo-Rexa SOLID-Q10-768A
SOLID 污水泵配备 SOLID 叶轮
Q
叶轮形式:
T = 闭式叶轮
G = 半开式单通道叶轮
Q = 半开式双流道叶轮
10 x10 = 压力连接公称直径
76 内部功率因数
8特征曲线编号
A
材料规格:
A = 标准规格
B = 防腐 1
D = 防磨 1
X = 特殊规格
4.8.4 电机型号代码:T 电机 示例:T 20.2M-4/32GX-P5
T表面冷却式电动机
20 规格
2版本
M轴型号
4极数
32 包装箱长度,单位 cm
G密封件规格
X具有防爆级
P
电机类型:
- 无 = 标准异步电动机
- E = 高效异步电动机
- P = 永磁电机
5
IE 能效等级(依据 IEC 60034-30):
无 = IE0 至 IE2
3 = IE3
4 = IE4
5 = IE5
4.9 供货范围 标准泵
ƒ水泵带裸露电缆端部
ƒ安装及操作说明
经过配置的水泵
ƒ水泵带裸露电缆端部
ƒ根据客户需求提供相应长度的电缆

运输和存放 zh-CHS
安装及操作说明 Wilo Motor T 17.3, 20.2:, EMU FA, Rexa SUPRA, Rexa SOLID 17
ƒ所安装的附件,例如外部铅芯湿度电极、水泵支脚等
ƒ安装及操作说明
4.10 附件 ƒ悬挂装置
ƒ水泵支脚
ƒ有 Ceram 涂层或使用特殊材料的特殊版本
ƒ外部铅芯湿度电极,用于密封室监控
ƒ液位控制装置
ƒ固定附件和链条
ƒ控制开关、继电器和插头
5 运输和存放
5.1 交货 收到货物之后,必须立刻检查货物有无缺陷(损坏、完整性)。如有缺陷,必须标
注在运单上!此外还必须在到货当天,将损坏情况告知运输公司或者生产商。如果
不在当天通知,就会丧失索赔权利。
5.2 运输
警告
在悬挂物下停留!
所有人严禁在悬挂物下停留!零部件掉落会导致(严重)受伤。悬挂物切勿从
有人员停留的工作位置上方经过!
警告
不佩戴防护装备会导致头部和脚部受伤!
工作时存在(严重)受伤危险。穿戴以下防护装备:
• 安全鞋
• 如果使用提升设备,还必须佩戴安全头盔!
注意
请只使用技术方面毫无瑕疵的提升设备!
请只使用技术方面毫无瑕疵的提升设备提升和降低水泵。确保水泵在升降过程
中不会卡住。切勿超过提升设备允许的最大承载能力!开始使用之前,先检查
提升设备的功能是否正常!
为了避免水泵在运输途中受损,到达使用地之后再拆除包装。发运使用过的水泵
时,必须使用尺寸足够大而且不易撕破的塑料袋进行包装,包装时注意收口。
此外还请注意以下几点:
Fig.2: 吊装孔
ƒ遵守所在国现行的安全法规。
ƒ使用合法且获得认证的升降装置和提升装置。
ƒ根据实际情况(天气、吊挂点、负载等)选择提升装置。
ƒ只将提升装置固定在吊挂点上。必须使用 卸扣进行固定。
ƒ使用具备足够承载能力的提升设备。
ƒ使用期间必须保证提升设备稳定可靠。
ƒ使用提升设备时,如果需要(比如视线受阻),必须安排另外一位工作人员负
责协调。

zh-CHS 安装及电气连接
18 WILO SE 2019-10
5.3 存放
危险
危害健康的流体会导致危险!
如果在危害健康的流体中使用过水泵,则拆卸水泵后必须进行消毒处理,之后
才能用于其他工作!有生命危险!遵守工作规程的相关规定!运营者必须保证
工作人员已经收到并阅读工作规程!
警告
叶轮和进水口的锋利边缘!
叶轮和进水口可能形成锋利的边缘。导致四肢被割伤的危险!必须佩戴防护手
套,防止出现切割受伤的情况。
小心
永磁电机:连接绞线可能通电!
通过旋转转子,在连接绞线上可能存在电压。将连接绞线绝缘但不短接!
小心
渗入湿气导致全损
液体进入接线电缆会损坏电缆和水泵!切勿将接线电缆端部浸入液体中,存放
时须将其牢牢封住。
新水泵到货后,可以存放一年。如果存放时间超过一年,请咨询客户服务部。
存放时注意下列事项:
ƒ将水泵直立(垂直)放置在坚固的基底上。防止水泵倾翻和移动!
ƒ存储温度范围是 -15 至 +60°C(5 至 140°F)。空气湿度最高 90%,非冷凝。
建议存储在无霜冻的环境中。环境温度:5 至 25°C(41 至 77°F),相对空气湿
度:40 至 50%。
ƒ切勿在执行焊接作业的室内存放水泵。因为焊接时形成的气体或辐射可能侵蚀
弹性体零件和涂镀。
ƒ牢牢封闭住吸入接口和压力连接。
ƒ保护接线电缆,防止其弯折和损坏。注意弯曲半径!
ƒ每隔一段时间(隔 3-6 个月),将叶轮转动 180°。从而防止轴承无法转动,并
更换机械密封的润滑膜。警告!叶轮和进水口的锋利边缘可能导致人员受伤!
ƒ弹性体零件和涂镀会自然脆化。如果存放时间超过 6 个月,必须咨询客户服务
部。
结束存放时段之后,必须清洁水泵上的灰尘和油,并检查涂镀和损坏情况。如果涂
镀受损,须在继续使用前将其修复。
6 安装及电气连接
6.1 工作人员资格鉴定 ƒ电气作业:电气作业必须由专业电工执行。
ƒ安装/拆卸工作:必须由专业人员执行,而且要求该人员接受过相关培训,了解
工作中会用到的工具以及当前施工现场需要使用的固定材料。
6.2 安装方式 ƒ垂直固定湿式安装
ƒ垂直移动湿式安装
ƒ垂直固定干式地坑安装
不支持下列安装方式:
ƒ卧式安装
6.3 运营者的责任 ƒ遵守本地现行的同业工伤事故保险联合会的事故防范规定和安全规定。
ƒ遵守有关处理重物或在悬挂物之下工作的所有法律法规。
ƒ提供防护装备并保证工作人员佩戴防护装备。
ƒ运行污水处理技术设备时,注意遵守当地实施的废水处理技术法规。
ƒ避免压力冲击!
高压管道较长且有明显的起伏时,可能出现压力冲击。该压力冲击可能导致水
泵损坏!

安装及电气连接 zh-CHS
安装及操作说明 Wilo Motor T 17.3, 20.2:, EMU FA, Rexa SUPRA, Rexa SOLID 19
ƒ根据运行条件和集水坑规格,保证电机冷却时间。
ƒ建筑/地基必须具有足够的强度,这样才能安全可靠地固定并确保功能正常。准
备建筑/地基并保证其适用性,是运营者的责任!
ƒ检查现有的规划资料(安装图、运行空间结构图、入流情况)是否齐全和正
确。
6.4 安装
危险
永磁电机:感应电压导致生命危险!
如果在没有电能情况下驱动转子(比如在流体回流时),电机会产生感应电
压。这时接线电缆会通电。触电导致生命危险!在连接前将接线电缆接地并导
出感应电压!
危险
独自执行危险作业导致生命危险!
需要在竖井和狭窄空间内完成的工作,以及存在坠落危险的工作,这两个都是
危险工种,不允许单人独自作业!为安全起见,必须有第二个人在场。
警告
不佩戴防护装备会导致手脚受伤!
工作时存在(严重)受伤危险。穿戴以下防护装备:
• 安全手套,用以预防切割伤害
• 安全鞋
• 如果使用提升设备,还必须佩戴安全头盔!
注意
请只使用技术方面毫无瑕疵的提升设备!
请只使用技术方面毫无瑕疵的提升设备提升和降低水泵。确保水泵在升降过程
中不会卡住。切勿超过提升设备允许的最大承载能力!开始使用之前,先检查
提升设备的功能是否正常!
ƒ如下准备运行空间/安装地点:
–干净,无大颗粒固体物
–干燥
–不上冻
–经过消毒处理
ƒ如果出现有毒气体或窒息气体汇集的情况,立刻采取对策!
ƒ将吊具通过一个卸扣固定在吊装孔上。只使用建筑技术允许使用的提升装置。
ƒ提升、降低和运输水泵时,使用吊具。绝对不得拉扯水泵的接线电缆!
ƒ必须能安全地安装提升设备。必须能通过提升设备到达储存位置和运行空间/安
装地点。安装位置的地基必须坚实。
ƒ铺设的接线电缆必须能够安全运行。检查电缆横截面和电缆长度对于选择的铺
设方式来说是否足够。
ƒ使用开关设备时,必须注意相应的防护等级。请将开关设备安装在潜在爆炸环
境以外且注意使其具有防溢流特性!
ƒ在入口使用导流板或偏转板,避免流体内进入空气。如有空气进入,会汇集在
管道系统中,导致形成不允许出现的运行条件。通过排气装置排出流体中的空
气!
ƒ禁止水泵空运行!避免水力部件外壳或管道系统内进入空气。切勿低于最低水
位。建议安装干转保护装置!
6.4.1 双头泵运行注意事项 如果在一个运行空间内使用多台水泵,则必须遵守水泵与水泵之间,以及水泵与墙
壁之间的最小距离。不同类型的设备,距离有所不同:交替运行或并联运行。

zh-CHS 安装及电气连接
20 WILO SE 2019-10
d
A2
A1
Fig.3: 最小距离
d 水力部件外壳直径
A1
最小距离:
- 交替运行:最小 0.3×d
- 并联运行:最小 1×d
A2
高压管道距离
- 交替运行:最小 1.5×d
- 并联运行:最小 2×d
6.4.2 维护工作 如果存放时间超过 6 个月,则在开始安装之前,需要进行以下维护工作:
ƒ转动叶轮。
ƒ检查密封室内的油。
6.4.2.1 转动叶轮
警告
叶轮和进水口的锋利边缘!
叶轮和进水口可能形成锋利的边缘。导致四肢被割伤的危险!必须佩戴防护手
套,防止出现切割受伤的情况。
小型水泵(出水口小于 DN100)
‡水泵未连接电网!
‡防护装备就位!
1. 将水泵水平放置在坚固的底座上。警告!手可能被挤伤。请确保水泵不会翻倒
或滑倒!
2. 小心谨慎地慢慢把手从下方伸进水力部件外壳中,转动叶轮。
大型水泵(出水口大于 DN150)
‡水泵未连接电网!
‡防护装备就位!
1. 将水泵垂直放置在坚固的底座上。警告!手可能被挤伤。请确保水泵不会翻倒
或滑倒!
2. 小心谨慎地慢慢把手从出水口伸进水力部件外壳中,转动叶轮。
6.4.2.2 检查密封室中的油
注意
加注油时,轻轻翻转电机!
为了将密封室加满油,轻轻翻转电机。在填充过程中,防止电机倾翻和移动!
This manual suits for next models
9
Table of contents
Other Wilo Engine manuals
Popular Engine manuals by other brands

Briggs & Stratton
Briggs & Stratton 90000 series Operating & maintenance instructions

Volvo Penta
Volvo Penta V6-200 Operator's manual

Navistar
Navistar N13 Service manual

RAMVAC
RAMVAC STANDARD 550 Service instruction

Nord Drivesystems
Nord Drivesystems B 1050 Series Operating and assembly instructions

IAME
IAME EASY-KART 2003 Assembly instructions and user's manual