WINDY NATION PIN-1500-12P User manual

windynation
VertaMax
Pure Sine Wave Power Inverter
PIN-1500-12P
PIN-3000-12P
User’s Manual

windynation
Page 2 of 16
VertaMax User Manual
Revision 1
Table of Contents
1Introduction .................................................................................................................3
1.1 Features ..........................................................................................................3
1.2 Safety Information............................................................................................3
1.3 Specifications...................................................................................................4
1.3.1 Electrical Specifications........................................................................................4
1.3.2 Physical Specifications.........................................................................................4
2Installation ...................................................................................................................4
2.1 Electrostatic (ESD) Precautions .......................................................................4
2.2 Mounting..........................................................................................................5
2.3 Grounding........................................................................................................5
2.4 Connections.....................................................................................................5
2.4.1 Permanent AC Connection* .................................................................................7
3Operation ....................................................................................................................8
3.1 Power ..............................................................................................................8
3.1.1 Power ON ............................................................................................................8
3.1.2 Power OFF .......................................................................................................... 8
3.1.3 Remote ON/OFF (optional) ..................................................................................8
3.2 Meter Readings ...............................................................................................9
3.3 Protection – Alarms..........................................................................................9
3.3.1 Over Input Voltage ...............................................................................................9
3.3.2Low Input Voltage ................................................................................................ 9
3.3.3 Power Overload ...................................................................................................9
3.3.4 Over Heating...................................................................................................... 10
3.3.5 Short Circuit ....................................................................................................... 10
3.3.6 Functional Matrix................................................................................................ 10
4Application.................................................................................................................10
4.1 Power Consumption.......................................................................................10
4.2 Typical Power Consumption ..........................................................................11
4.3 Wire Gauge Reference ..................................................................................11
4.3.1 Ampacity Table .................................................................................................. 11
4.3.2 Wire Thickness .................................................................................................. 11
4.4 Batteries ........................................................................................................12
4.4.1 Battery Life......................................................................................................... 12
4.4.2 Battery State of Charge (SOC)........................................................................... 12
4.4.3 Actual Battery Current Draw............................................................................... 12
4.4.4 Battery Capacity................................................................................................. 12
5Troubleshooting And Support ....................................................................................13
5.1 Maintenance & Care ......................................................................................13
5.2 Troubleshooting .............................................................................................13
5.3 Support ..........................................................................................................14
5.4 Warranty........................................................................................................14
5.4.1 Restrictions ........................................................................................................ 14
5.4.2 Warranty Claims & Return Procedures............................................................... 15
5.4.3 Disclaimer .......................................................................................................... 15
5.4.4 Limitation of Liability........................................................................................... 16

windynation
Revision 1
VertaMax User Manual
Page 3 of 16
1 INTRODUCTION
The VertaMax Power Inverter is a highly reliable product that uses advanced technologies for
high performance and stability. The VertaMax efficiently converts DC power from your vehicle,
boat, or directly from a dedicated 12V DC battery, into 115V AC power that is commonly used in
a wide variety of household AC items, such as computers, mobile phone chargers, radio, TV etc.
The VertaMax has many features that you would expect in very high end inverters as well as all
the safety features that would be desired to protect your equipment.
The Inverter may be used for many different applications including Solar (PV) battery systems,
Wind Turbine battery systems, Recreational Vehicles, Boats, etc.
Please read this manual carefully before installing or using the inverter and keep it for future
reference.
1.1 FEATURES
Microprocessor Based PWM (Pulse Width Modulation) Output Regulation
Pure Sine Wave
Three AC Receptacles with Circuit Breakers
Soft Start
Digital Display Voltage and Power Meter
Power On/OFF Switch and LED indicator
Remote On/Off Capability
Automatic Overload Protection
Low Voltage Shutdown Battery Protection
Short Circuit Protection
High Temperature Protection
Fault Indication
Load and Thermally Activated Cooling Fans
1
DC Positive (+) Input
8
Remote Switch Port3
2
Cooling Fan1
9
Power LED
3
DC Negative (-) Input
10
Digital Display Meter
4
Grounding Terminal
11
Fault LED
5
Permanent AC Connection2
12
ON/OFF Switch
6
Circuit Breaker Protector [x3]
13
Digital Display Select Switch
7
AC Outlets [x3]
1Number of fans depends on model
2Not available on all models
3Optional Remote Cable required [PN: PIN-RMPS-01]
1.2 SAFETY INFORMATION
Please read the installation and operating instructions carefully prior to use. Pay special attention
to the IMPORTANT and WARNING statements in the manual.
WARNING:
The VertaMax produces the same potentially lethal AC power as normal household outlets. It is
suggested that you treat it with the same precautions as a normal 115 VAC outlet.

windynation
Page 4 of 16
VertaMax User Manual
Revision 1
Do not operate the VertaMax near flammable fumes or gases, such as in the cabin of a gasoline
powerboat, or near propane tanks.
Never work or service the AC wiring without disconnecting the DC Input connections.
Do not connect or disconnect batteries while the Inverter is operating from the battery supply.
Dangerous arcing may result.
1.3 SPECIFICATIONS
1.3.1 Electrical Specifications
Parameter
PIN-1500-12P
PIN-3000-12P
Continuous Rated Power
1500 Watts
3000 Watts
Peak Surge Power
3000 Watts
6000 Watts
Input Voltage (Nominal)
12 – 13 VDC
Input Voltage (Min – Max)
11 – 15VDC
Output Voltage (Nominal)
115VAC
Output Frequency (Nominal)
60 Hz
Output Waveform
Pure Sine Wave - THD <3%
Standby Current
<1.0A
Low Battery Voltage Alarm
10.5 VDC (+/-0.5VDC)
Low Battery Voltage Shutdown
10.0 VDC (+/-0.5VDC)
High Battery Voltage Shutdown
16 VDC (+/-0.5VDC)
Efficiency
85-90%
1.3.2 Physical Specifications
Parameter
PIN-1500-12P
PIN-3000-12P
Dimension (L x W x H)
13.0” x 8.7” x 3.0”
(330mm x 221mm x 76mm)
16.7” x 10.3” x 3.7”
(425mm x 262mm x 94mm)
Unit Weight
8.2 lb. (3.7kg)
15.4 lb. (7.0kg)
Cooling
Auto Powered Fan
Operating Temperature
0oC to 60oC
Storage Temperature
-25oC to 70oC
Operating Humidity
20 to 80% relative humidity (non-condensing)
Thermal Protection
>65oC
2 INSTALLATION
Insure all terminating connections are clean and tight to prevent arcing and overheating.
The VertaMax must be installed in an area that satisfies all of the following conditions:
1. Dry: Avoid any location where water can contact the inverter
2. Cool: Ambient air temperature between 30°F and 105°F (0°C and 40°C)
3. Ventilated: Allow at least 6 in (150 mm) of clearance above and below and at least
1 in (25 mm) on each side for proper air flow.
4. Safe: Do not operate in a shared compartment with batteries or any flammable
substances, (e.g.: gasoline)
IMPORTANT:To avoid fire, do not cover or obstruct ventilation openings.
2.1 ELECTROSTATIC (ESD) PRECAUTIONS
All electronic circuits may be damaged by static electricity. To minimize the likelihood of
electrostatic damage, discharge yourself by touching an electrical ground (e.g.: copper pipe) prior
to handling the unit and avoid touching components on the circuit boards. The risk of electrostatic
damage is highest when relative humidity is below 40%.

windynation
Revision 1
VertaMax User Manual
Page 5 of 16
2.2 MOUNTING
Mounting is optional for the VertaMax; however, the environment must be dry and protected from
water.
1. The VertaMax can be mounted on a vertical or horizontal surface. If mounted
vertically, the unit should be oriented such that neither end is at the top so foreign
material cannot settle into the unit.
2. Install four user-supplied fasteners through the four inverter mounting slots and
into the mounting surface.
3. Tighten all the fasteners to ensure the inverter cannot slide in any direction.
WARNING: Do not mount on flammable surface material.
2.3 GROUNDING
The VertaMax is designed to work with grounded electrical systems. In the inverter, ground is not
connected to the input terminals.
Use a copper wire to connect the grounding terminal on the VertaMax enclosure to earth ground
or chassis ground. The grounding terminal is located on the DC Input end of the inverter.
•Vehicle installations: Connect to the chassis of the vehicle.
•Boats installations: Connect to the boat’s grounding system
•Fixed land based installations: Connect to earth ground
Do not connect the system negative conductor to this terminal. NEC requires the use of an
external ground fault protection device (GFPD). The system electrical negative should be bonded
through a GFPD to earth ground at one (and only one) location. The grounding point may be
located in the solar/wind circuit or the battery circuit.
2.4 CONNECTIONS
WARNING: Electrical installations must meet local and national wiring codes, and should be
performed by a qualified electrician.
WARNING: Do not connect the inverter and another AC source (such as a generator or utility
power) to the AC wiring at the same time.
WARNING: Do not connect the inverter to an AC branch circuit that has high-power consumption
loads. It will not operate electrical appliances that consume more than the units rated watts.
WARNING: Loose connectors result in excessive voltage drop and may cause over heated wires
and melted insulation, which can lead to electrical fires.
WARNING: Reverse polarity connections (positive to negative) will blow internal fuses in the
inverter and may permanently damage the Inverter.
IMPORTANT: The NEC requires that the wires carrying the system current never exceed 80% of
the conductor’s current rating (sizing recommendations are located in Section 4).
IMPORTANT: In addition to the protection provided by the Inverter’s internal fuses, NEC requires
a UL-listed fuse in the battery’s positive DC cable as close to the battery as possible (sizing
recommendations are located in Section 4).
1) The VertaMax has two DC terminals (one positive and one negative). The cables used for
these terminals should be of equal length.
This manual suits for next models
1
Table of contents
Other WINDY NATION Inverter manuals
Popular Inverter manuals by other brands

BARRON
BARRON EXITRONIX Tucson Micro Series installation instructions

Baumer
Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

electroil
electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

Silicon Solar
Silicon Solar TPS555-1230 instruction manual

Mission Critical
Mission Critical Xantrex Freedom SW-RVC owner's guide

HP
HP 3312A Operating and service manual