wink haus blueMatic EAV Assembly instructions

winkhaus.de
blueMatic EAV
Automatic locking system with motorised opening function
(12 V DC)
Installation, Operating and Maintenance Instructions
02/2021

2
3
4
5
6
7
8
9
1
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
10
This security door locking system complies with the requirements and directives
established and stipulated by the Council on the Harmonization of Legal
Regulations of Member States regarding Electromagnetic Compatibility
(2014/30/EU).
The manufacturer shall hereby certify the conformity of this product and docu-
ment such by the CE marking according to the CPR EN 14846 (see chapter 9).
Berkeser Straße 6
D-98617 Meiningen
Germany
T + 49 (0) 3693 950-0
F + 49 (0) 3693 950-134
www.winkhaus.de
The following information and graphic images provided correspond to the
current status of the development and manufacture of this product.
For the purpose of customer satisfaction and operational reliability of the
blueMatic EAV
(Automatic locking system with motorised opening function), we
reserve the right to make changes to this product without notice.
All information and specifications given in this operating manual have been
compiled and reviewed with the utmost care.
Due to the nature of advances in technology, or amendments to legal
regulations and other compulsory changes we do not guarantee the accuracy
and completeness of the contents’ statements.
We always appreciate suggestions or comments.
The blueMatic EAV (Automatic locking system with motorised opening
function) can be easily installed, if these operating instructions and the door
specifications indicated have been adhered to.
© Aug. Winkhaus GmbH & Co. KG, All rights reserved. Last revised: 02/2021
Aug. Winkhaus GmbH & Co. KG

2
3
4
5
6
7
8
9
1
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
10
1 Important information
1.1 General information P. 6
1.2 Intended use P. 6
1.3 Use contrary to the intended purpose P. 8
1.4 Explanation of symbols P. 9
1.5 Important safety information P. 10
1.6 Abbreviations / Explanations P. 11
2 Product description
Automatic locking system autoLock AV3 P. 16
Motor housing P. 25
Keep rail / Extension keep set / Single keeps P. 26
Center keep FRA ... AV ... P. 27
Magnetic trigger for center keep FRA ... AV ... P. 27
Daytime latch "TAFA" P. 28
Cable transition P. 29
Cable transition sash part T-KÜ-T1 FT ... P. 29
Cable transition frame part for T-KÜ-T1 P. 31
Cable transition frame part for external power supply P. 31
Cable transition frame part for frame power supply P. 31
Power supply P. 32
External power supply P. 32
Frame power supply (optional) P. 33
Access control systems P. 34

2
3
4
5
6
7
8
9
1
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
10
3 Installation
3.1 Routing details P. 36
3.2 Cable transition T-KÜ-T1 ... (sash- & frame part) P. 38
3.3 Installations P. 42
3.3.1 General connection diagram P. 43
3.4 Access control system transponder set P. 44
3.5 Access control system wireless remote control P. 47
3.5.1 Wireless remote control set P. 47
3.5.2 Wireless receiver (separate) P. 51
3.6 Non Winkhaus access control system (ACS) P. 53
3.6.1 Non Winkhaus access control system ACS general
(frame- and sash side) P. 53
3.6.2 Non Winkhaus access control system ACS
fingerprint (sash side) P. 53
3.7 Control of additional functions P. 66
4 Operation/Programming
4.1 blueMatic EAV P. 67
4.1.1 Locking and unlocking P. 67
4.2 blueMatic EAV with Transponder P. 68
4.2.1 Operation P. 68
4.2.2 Programming P. 69
4.3 blueMatic EAV with wireless remote control P. 71
4.3.1 Operation P. 71
4.3.2 Programming P. 71
4.4 Wireless receiver for additional applications
(e.g. garage door control units) P. 75

2
3
4
5
6
7
8
9
1
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
10
5 Maintenance and care
6 Errors/Causes/Troubleshooting
7 Technical specifications
7.1 Motor housing EAV3 P. 81
7.2 Power supply (mounting on DIN rail) P. 81
7.3 Frame power supply P. 81
7.4 Antenna / Reader P. 82
7.5 Wireless remote control P. 82
7.6 Cable transition T-KÜ-T1 FT P. 83
8 Accessories
9 Classification/Declaration of performance
9.1 Electromechanical locks according to EN 14846 P. 88
9.2 VdS Acceptance (based on VdS 2344, 2201) P. 88
9.3 Certificat DIN 18251-3 P. 88
10 Disposal

blueMatic EAV 50447446Installation, Operating and
Maintenance Instructions
1
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
1 Important information
Dear Customer!
We would like to thank you for your confidence you have put in us by purchasing
our high-quality product.
Please read this installation, operating and maintenance instruction carefully to
become acquainted with the installation and use of this security door locking
system and to avoid malfunctions and safety hazards.
1.1 General information
The automatic locking system blueMatic EAV (Automatic locking system with
motorised opening function) and the Winkhaus components recommended
are suitable for the following areas of application:
• relative air humidity of max. 95%
• ambient air temperature of between -20°C ... +60°C.
The components/motor housings described here are, in the sense of blueMatic
EAV2 and EAV3, suitable for autoLock AV3/AV3 OR + AP179 AV3 OR locks and
also backwards compatible for autoLock AV2.
The complete door fittings are designed to be used in conjunction with genuine
Winkhaus parts. Other parts which are not recommended by Winkhaus can
adversely aect the default properties of this locking system. It is assumed that
the lock will be used as intended.
1.2 Intended use
Acceptance class A for autoLock AV2,
Acceptance-No.: M105301
Acceptance class B for autoLock AV3,
Acceptance-No.: M113345

blueMatic EAV 50447447Installation, Operating and
Maintenance Instructions
1
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
To ensure the intended use:
• the information and instructions required for this purpose have to be passed
on to the respective persons,
• only trained professionals should install the door furniture, locking units and
accessory parts according to the installation instructions. Applicable DIN, EN
standards and BauPVO are about to follow.
The stipulations for use as intended have been met, once the Winkhaus fittings
are:
• installed according to their defined function and the installation
specifications,
• not used in any other way than described,
• maintained and cared for at regular intervals as instructed, and/or defined
sliding places oil at least 1 x annually (like e.g. chamfer of latch …) if necessary
more frequently,
• not used if signs of wear are detected,
• repaired by trained professionals in the event of malfunctions.
The supplier/manufacturer does not accept any liability for personal injury or
material damage caused by incorrect operation or improper use.
The proper functions of the access control systems and the accessories included
in the scope of delivery of the Winkhaus company have been tested. If you use
components made by other companies and if you have any doubts about the
suitability of these components, you will have to contact the respective manu-
facturer to ensure their fitness for use.

blueMatic EAV 50447448Installation, Operating and
Maintenance Instructions
1
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
The locking systems are not designed to absorb or compensate for any
movement changes or in the closing mechanism of the door caused by
changes in temperature or in the structure of the building.
Doors which are used in damp rooms and in environments with aggressive
corrosion related air conditions require special door furniture.
The locking systems are incorrectly used – that is used contrary to the terms de-
scribed above – in evident in particular, if:
• the instructions on the intended use are not being followed;
• the problem-free operation is hindered due to the installation of external
objects and/or objects that are not purpose-conformant in the opening
zone, the locking system or within the keeps;
• the locking system or the center keep is manipulated in such a way that its
design, mode of operation or function is changed;
• the door is drilled through in the area of the lock housings or of the lock rod
once the lock has been installed;
• the dead bolt projection or other locking components are employed
contrary to their intended purpose, as a means to hold the door opened or
attempts are made with excluded locking element to close the door element;
• the handle’s pin is driven through the spindle with force;
• the locking elements are wrongly installed or are tampered with, e.g. by
overpainting movable parts like the latch bolt;
• loads exceeding those of normal manual force are transmitted via the safety
key onto the lock system;
• perform a manual or mechanical locking or unlocking during the motor is
working;
• the handle is turned counterclockwise or if a force greater than 150 N is
exerted on the handle;
• the clearance between the door frame and sash is increased or decreased,
which would for instance result from readjusting the hinge plates or from
lowering the door;
• if auxiliary lifting tools or other tools are used to open or close the lock;
• the handle and key are used at the same time;
• the lock is locked/unlocked by using improper objects;
• the size of the door opening deviates from the specifications prescribed.
1.3 Use contrary to the intended purpose

DANGER!
Danger to life or danger of serious injuries.
Caution!
Danger of material damage.
Notice:
Useful information and tips.
Eco-Watch:
Notices on complying with regulations on environmental
protection.
blueMatic EAV 50447449Installation, Operating and
Maintenance Instructions
1
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
Flags are used to identify important information in this operating manual. Flags
such as DANGER or CAUTION indicate the degree of hazard.
It is imperative that you do follow the measures listed to avoid safety hazards!
1.4 Explanation of symbols
Disposal!
Environmental damage due to incorrect disposal of batteries
and electronic components!

Caution! The wiring / cable transitions must be installed in the
safe area (e.g. installed concealed in the airgap) and protected
against manipulation.
blueMatic EAV 504474410Installation, Operating and
Maintenance Instructions
1
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
Safety information described in this section is to be diligently adhered to
regarding the installation and use of this security lock blueMatic EAV!
You must heed to the safety information provided without exceptions!
• Read the installation, operating and maintenance instructions it easily
accessible for future reference. After installing the door pass it on to the end
customer.
• The manufacturer shall not be held liable for damage caused by use contrary
to the intended purpose of the product.
• For security reasons, the lock has been designed to be used in conjunction
with genuine Winkhaus parts. Using other parts may adversely affect the
given properties of the security lock.
• It must be ensured that the door can be closed/unlocked without any
problems by the key.
• Installation/repair of electrical equipment requires expertise, thus such work
should only be carried out by a qualified electrician.
• Arbitrary modifications, changes or makeshift repairs are not permitted
due to concerns for safety. You must only use genuine Winkhaus parts for
replacements.
• The manufacturer shall only be held liable for security related properties of
the locking system as stipulated within the bounds of statutory regulations, if
the manufacturer himself or another instructed, authorized agent has carried
out the maintenance and service work or made the changes.
• Winkhaus does not accept liability for any type of damage caused by
inadequate repair, modification or maintenance works made.
1.5 Important safety information

blueMatic EAV 504474411Installation, Operating and
Maintenance Instructions
1
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
The following terms and abbreviations are used in this manual:
T- Product area security door lock
AV2 autoLock AV2 (Automatic locking system)
2. generation
AV3 autoLock AV3 (Automatic locking system)
3. generation
EAV blueMatic EAV (Automatic locking system with
motorised opening function)
Handle Door handle
Grt. Set
SB FRA Center keep - latch/dead bolt/adjustment plate
M2 with 2 hooks
MV means "upper adjustment"
UMV means "lower adjustment"
RS DIN-right-handed
LS DIN-left-handed
GR Surface grey powder coated
EST Surface stainless steel
MC Surface matt chrome-plated
Reader Reader/control unit of the transponder set
ZKS (ACS) Access control system
UP-socket Flush-type box
LED Light emitting diode
ANT/GND Auxiliary antenna/ground
PE Ground wire
N Neutral wire
L Phase
AC Alternating current
DC Direct current
NO Make contact
NC Break contact
NO-NC Changer contact
1.6 Abbreviations/Explanations

blueMatic EAV 504474412Installation, Operating and
Maintenance Instructions
1
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
2 Product description
The blueMatic EAV (Automatic locking system with motorised opening function)
is a state-of-the-art locking unit for securing and locking entry doors in a
contact-free manner. The hooks can be retracted electrically so as to open the
door.
Figure 2-1: blueMatic EAV with accessories and external power supply
In the
external
zone around
the entry
door
230 V AC

blueMatic EAV 504474413Installation, Operating and
Maintenance Instructions
2
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
Figure 2-2: blueMatic EAV with accessories and frame power supply
T-NETZTEIL RAHM. 12 V DC 1,5 A
230 V AC
In the
external
zone around
the entry
door

blueMatic EAV 504474414Installation, Operating and
Maintenance Instructions
2
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
No.
Name MUST!
Manda-
tory *
Available
as an
accessory
or as an
option
Supplied by
customer /
not included
in standard
delivery
autoLock AV (Automatic locking
system STV-AV)
X
Motor housing EAV
Keep rail T-SLExtension keep set
T-Grt SLSingle keeps T-SB
X X
Center keep T-SB FRA AV
X X
Magnetic trigger
X
X
Daytime latch TaFa
X
Cable transition
X
Cable transition sash part T-KÜ-T
FT eg T-KÜ-T FT MMM
Cable at the sash side m m or
m long plug for motor housing
included as well as cable transition
sets for connection of external access
controls
X
Cable transition frame part
(suitable the sash part T-KÜ-T FT )
X
Figure -
T-KÜ-T RT KABEL M
including cable m for connection of
external access controls eg inter-
com potential-free contact
Figure - T-KÜ-T RT KABEL M
RNT with plug connection to the fra-
me power supply V DC (optional)

blueMatic EAV 504474415Installation, Operating and
Maintenance Instructions
2
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
No.
Name MUST!
Manda-
tory *
Available
as an
accessory
or as an
option
Supplied by
customer /
not included
in standard
delivery
Power supply
X
Figure - Power supply
T-HT NETZTEIL V DCA
mounting on DIN rail
Figure - Frame power supply
T-NETZTEILRAHM V DC A
(AS)
(optional)
including cable for connection of ex-
ternal access controls eg intercom
potential-free contact
Access control system
(shown antenna of the transponder
set)
Notice Only install the antenna of
the transponder set in the external
zone around the entry door! **
X
Open button
X
Flush-type box
X
Handle
X
* remaining components recommended for use, or should be used
alternatively
** not extend cable

blueMatic EAV 504474416Installation, Operating and
Maintenance Instructions
2
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
The autoLock AV3 from Winkhaus is an auto-
matic multipoint locking system with indepen-
dently acting hooks for claw action and sealing
elements for a dynamic contact pressure.
This is prepared for installation of the profile
cylinder corresponding to EN 1303 (corrosion
class C) with closed position of ± 45°, in each
case with smooth-running free-to-turn function
or stationary cam position.
Automatic locking system autoLock AV3

blueMatic EAV 504474417Installation, Operating and
Maintenance Instructions
2
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
Automatic locking system autoLock AV3
Part Description Part-no.
DIN RS DIN LS
T-AV-F L A M RSLS MC
T-AV-F L A KABA M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS GR
T-AV-F L A MK RSLS MC
T-AV-F L A KABA M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A KABA M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A KABA M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A KABA M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A KABA M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A KABA M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC

blueMatic EAV 504474418Installation, Operating and
Maintenance Instructions
2
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
Automatic locking system autoLock AV3
Part Description Part-no.
DIN RS DIN LS
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A MK RSLS MC
T-AV-F L A KABA M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC

blueMatic EAV 504474419Installation, Operating and
Maintenance Instructions
2
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
Automatic locking system autoLock AV3
Part Description Part-no.
DIN RS DIN LS
T-AV-F L A M RSLSMC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS GR
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS GR
T-AV-F L A KABA M RSLS MC
T-AV-F L S M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS GR
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS GR
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC

blueMatic EAV 504474420Installation, Operating and
Maintenance Instructions
2
EN
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
Automatic locking system autoLock AV3
Part Description Part-no.
DIN RS DIN LS
T-AV F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS GR
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS GR
T-AV-F L S M RSLS MC
T-AV F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A KABA M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A KABA M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-LB AV-F L A M RSLS MC
T-LB AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS GR
T-AV-F L A M RSLS EST
T-AV-F L A M RSLS MC
T-AV-F L A M RSLS GR
T-AV-F L A M RSLS MC
T-AV-F L A KABA M RSLS MC
Other manuals for blueMatic EAV
2
Table of contents
Other wink haus Door Opening System manuals