Winland Electronics HUMID-ALERT HA-III+ User manual

Electronic Humidity Sensor
D-011-0105 Rev D (04/2011)
ONE YEAR LIMITED WARRANTY
Winland Electronics, Inc. warrants that each product of its manufacture is free from defects in
material and factory workmanship, when properly installed and operated under normal conditions
according to the manufacturer’s instructions. Manufacturer’s obligation under this warranty is
limited to correcting, without charge, at its factory any part of parts thereof which shall be returned
to the factory, by the original retail purchaser, transportation charges prepaid, within one year after
purchase and which upon examination shall disclose to the manufacturer’s satisfaction to have
been originally defective. Correction of such defects by repair to, or supplying of replacements for
defective parts shall constitute fulfillment of all obligations to purchaser. Repair service performed by
the manufacturer after one year from date of purchase will be for a reasonable service charge. This
warranty shall not apply to any of the manufacturer’s products which have been subject to misuse,
negligence or accident of which shall have been repaired or altered outside of the manufacturer’s
factory. Manufacturer shall not be liable for loss, damage, or expense directly or indirectly from the
use of its product or from any other cause. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED. WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR
PURPOSE ARE EXCLUDED, AS ARE ALL OTHER REPRESENTATIONS TO THE USER-PURCHASER, AND ALL
OTHER OBLIGATIONS OR LIABILITIES, INCLUDING LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL
DAMAGES, ON THE PART OF THE MANUFACTURER OR THE SELLER. No person, agent or dealer is
authorized to give any warranties on behalf of the manufacturer nor to assume for the manufacturer
any other liability in connection with any of its products.
SPECIFICATIONS
Power Requirements 12 VDC @10mA
Sensing Element Capacitive / IC
Sensing Range 5% - 95% R.H.
Accuracy ±5% (10% - 90% RH @ 77° F [25° C])
Response Time TC < 12 minutes
Operating Temp +32˚ to +152˚F (0˚ to +50˚C)
Weight 5 oz (0.14 g)
Dimensions 3.25 x 1.5 x 1” (8.2 x 3.7 x 2.5 cm)
Mounting Surface mount
Case Material ABS
Warranty 1 Year Limited
CONTENTS
This package contains:
• 1 HA-III+
• 2 Mounting Screws and 2 anchors
• 1 Installation/Operating Instructions Guide HA-III+
WEEE Product Recovery/Recycling for EU Customers
In an effort to improve waste management in the European Union, the European Union has enacted
directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE Directive). According to the
WEEE Directive, Winland Electronics must take back waste electrical or electronic equipment covered
under the WEEE Directive, at its cost, for all product it puts on the market after July 1, 2006. The Return
Process: Contact Winland via our web site at www.winland.com and go to the WEEE link on the home
page. To request additional information regarding Winland’s RoHS and WEEE compliance initiative and
how it might impact your business, email customerservice@winland.com.
HA-III+ Certification Info
Radio Frequency Interference Requirements: This device complies with Part 15 of
the FCC Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
CE Marking and European Union Compliance: Products intended for sale within
the European Union are marked with the CE Mark, which indicates compliance to
applicable Directives and European Norms (EN). Amendments to these Directives or
ENs are included:
Electromagnetic Compatibility Directive 89/336/EEC; RoHS Directive 2002/95/EC;
WEEE Directive 2002/96/EC
Statement of Compliance
Winland Electronics, Inc. hereby declares that this device is in compliance with all the applicable
Directives, 89/336/EEC, 2002/95/EC, 2002/96/EC.
Symbols on the Product or Manual Labeling
For product disposal, ensure the following:
• Do not dispose of this product as unsorted municipal waste.
• Collect this product separately.
• Use collection and return systems available to you.
WEEE Waste Electrical and Electronic Equipment
RoHS Restriction of Hazardous Substances
1950 Excel Drive • Mankato, MN 56001 USA
(Tech Support 8:00am - 5:00pm CST)
(800) 635-4269 • (507) 625-7231 P • (507) 387-2488 F
www.winland.com
General Information
The Winland HA-III+ is a sensor used for monitoring remote locations for rising or falling
rates of humidity. The HA-III+ is designed and approved to be used with the EnviroAlert®
family of monitoring devices including the EA800, EA400-12 and EA200-12. The HA-III+
may also be used with Winland legacy monitoring devices including the TA-2HLD,
TA-3HLD, UTA-1, DTA-4 and DPM-4.
The setup of high and low limits is done through the interface on the monitoring device
you are connecting to.
Important Note: HA-III+ must not be used with monitoring devices that are powered
with 24V AC/DC. When used with Winland legacy monitoring devices such as UTA-1,
TA-2HLD, TA-3HLD, DTA-4 or DPM-4, the monitoring devices must be set to read
Fahrenheit.
Theory of Operation
The HA-III+ senses the ambient room humidity electronically using a capacitive sensing
element. Humidity should be expected to vary from room to room and from one area of
a room to another. Ventilation and airflow will greatly affect relative humidity.
When programming the HA-III+ sensor on the monitoring device, the initial reading you
receive should be considered a base reading. Allow at least 30 minutes of operation
for sensor to stabilize prior to setting your high and low limits. It is necessary for the
temperature of the sensor to stabilize before the readings are considered accurate. The
outputs of Winland’s electronic monitoring devices react within seconds of a limit being
exceeded. A sudden burst of humid air from a door opening or a ventilation system
starting, could cause a brief change in the humidity reading. To avoid false alarms, a time
delay should be programmed into the EA800, EA400-12, EA200-12, UTA-1 or TA-2HLD. It
is strongly recommended to utilize a time delay unless your application requires
instant notification.
Installation
The HA-III+ sensor should be flush mounted directly to a flat surface like a wall. The
sensor should be located in an area free from drafts, heat sources, and direct sunlight. It is
recommended that the sensor is mounted at a height of 4-5’ (1.2-1.5 m) from the floor.
To begin installation of the HA-III+, you must first remove the cover. Do not use excessive
force while removing the cover, you may crack or break the plastic housing. Grasp the
HA-III+ between your thumb and index fingers along the long slotted surfaces of the
sensor with the Winland logo facing you. Using a flat bladed screwdriver, insert tip of
screwdriver into pry slot and gently pry open top cover until it swings loose from the
base (See Figure 1). Remove screwdriver from pry slot, grasp cover beneath detached
flange and swing to the right until cover fully detaches.
With the cover now fully removed, fasten the base of the sensor to the wall via the screw
holes in the base plate using the two screws provided.
Wire the HA-III+ to your monitoring device using the following wiring scheme
(See Figures 2 and 3).
Connection will either be made to the Sink terminal screw or the Source terminal
screw, never both.
Avoid tucking excess wires under the PC board. To allow for maximum air movement,
make certain that no wires surround the sensor which is located in the lower left hand
corner of the PC board. Replace the cover by aligning the slots in the cover with the tabs
on the base and slide the cover back toward the mounting surface until both side flanges
snap into place.
FIGURE 3
(Shows Typical Use With an EnviroAlert® Device)
Power Input = 12VDC Positive
GND = 12VDC Negative
Sink = Wire to either the white/brown or the white/red sensor input on the DTA-4 or DPM-4
Source = Wire to negative terminal on sensor input of the desired device:
EA800, EA400-12, EA200-12, UTA-1, TA-2HLD, and TA-3HLD (See Figure 3)
FIGURE 2
FIGURE 1
General Information
The Winland HA-III+ is a sensor used for monitoring remote locations for rising or falling
rates of humidity. The HA-III+ is designed and approved to be used with the EnviroAlert®
family of monitoring devices including the EA800, EA400-12 and EA200-12. The HA-III+
may also be used with Winland legacy monitoring devices including the TA-2HLD,
TA-3HLD, UTA-1, DTA-4 and DPM-4.
The setup of high and low limits is done through the interface on the monitoring device
you are connecting to.
Important Note: HA-III+ must not be used with monitoring devices that are powered
with 24V AC/DC. When used with Winland legacy monitoring devices such as UTA-1,
TA-2HLD, TA-3HLD, DTA-4 or DPM-4, the monitoring devices must be set to read
Fahrenheit.
Theory of Operation
The HA-III+ senses the ambient room humidity electronically using a capacitive sensing
element. Humidity should be expected to vary from room to room and from one area of
a room to another. Ventilation and airflow will greatly affect relative humidity.
When programming the HA-III+ sensor on the monitoring device, the initial reading you
receive should be considered a base reading. Allow at least 30 minutes of operation
for sensor to stabilize prior to setting your high and low limits. It is necessary for the
temperature of the sensor to stabilize before the readings are considered accurate. The
outputs of Winland’s electronic monitoring devices react within seconds of a limit being
exceeded. A sudden burst of humid air from a door opening or a ventilation system
starting, could cause a brief change in the humidity reading. To avoid false alarms, a time
delay should be programmed into the EA800, EA400-12, EA200-12, UTA-1 or TA-2HLD. It
is strongly recommended to utilize a time delay unless your application requires
instant notification.
Installation
The HA-III+ sensor should be flush mounted directly to a flat surface like a wall. The
sensor should be located in an area free from drafts, heat sources, and direct sunlight. It is
recommended that the sensor is mounted at a height of 4-5’ (1.2-1.5 m) from the floor.
To begin installation of the HA-III+, you must first remove the cover. Do not use excessive
force while removing the cover, you may crack or break the plastic housing. Grasp the
HA-III+ between your thumb and index fingers along the long slotted surfaces of the
sensor with the Winland logo facing you. Using a flat bladed screwdriver, insert tip of
screwdriver into pry slot and gently pry open top cover until it swings loose from the
base (See Figure 1). Remove screwdriver from pry slot, grasp cover beneath detached
flange and swing to the right until cover fully detaches.
With the cover now fully removed, fasten the base of the sensor to the wall via the screw
holes in the base plate using the two screws provided.
Wire the HA-III+ to your monitoring device using the following wiring scheme
(See Figures 2 and 3).
Connection will either be made to the Sink terminal screw or the Source terminal
screw, never both.
Avoid tucking excess wires under the PC board. To allow for maximum air movement,
make certain that no wires surround the sensor which is located in the lower left hand
corner of the PC board. Replace the cover by aligning the slots in the cover with the tabs
on the base and slide the cover back toward the mounting surface until both side flanges
snap into place.
FIGURE 3
(Shows Typical Use With an EnviroAlert® Device)
Power Input = 12VDC Positive
GND = 12VDC Negative
Sink = Wire to either the white/brown or the white/red sensor input on the DTA-4 or DPM-4
Source = Wire to negative terminal on sensor input of the desired device:
EA800, EA400-12, EA200-12, UTA-1, TA-2HLD, and TA-3HLD (See Figure 3)
FIGURE 2
FIGURE 1
Electronic Humidity Sensor
D-011-0105 Rev D (04/2011)
ONE YEAR LIMITED WARRANTY
Winland Electronics, Inc. warrants that each product of its manufacture is free from defects in
material and factory workmanship, when properly installed and operated under normal conditions
according to the manufacturer’s instructions. Manufacturer’s obligation under this warranty is
limited to correcting, without charge, at its factory any part of parts thereof which shall be returned
to the factory, by the original retail purchaser, transportation charges prepaid, within one year after
purchase and which upon examination shall disclose to the manufacturer’s satisfaction to have
been originally defective. Correction of such defects by repair to, or supplying of replacements for
defective parts shall constitute fulfillment of all obligations to purchaser. Repair service performed by
the manufacturer after one year from date of purchase will be for a reasonable service charge. This
warranty shall not apply to any of the manufacturer’s products which have been subject to misuse,
negligence or accident of which shall have been repaired or altered outside of the manufacturer’s
factory. Manufacturer shall not be liable for loss, damage, or expense directly or indirectly from the
use of its product or from any other cause. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED. WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR
PURPOSE ARE EXCLUDED, AS ARE ALL OTHER REPRESENTATIONS TO THE USER-PURCHASER, AND ALL
OTHER OBLIGATIONS OR LIABILITIES, INCLUDING LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL
DAMAGES, ON THE PART OF THE MANUFACTURER OR THE SELLER. No person, agent or dealer is
authorized to give any warranties on behalf of the manufacturer nor to assume for the manufacturer
any other liability in connection with any of its products.
SPECIFICATIONS
Power Requirements 12 VDC @10mA
Sensing Element Capacitive / IC
Sensing Range 5% - 95% R.H.
Accuracy ±5% (10% - 90% RH @ 77° F [25° C])
Response Time TC < 12 minutes
Operating Temp +32˚ to +152˚F (0˚ to +50˚C)
Weight 5 oz (0.14 g)
Dimensions 3.25 x 1.5 x 1” (8.2 x 3.7 x 2.5 cm)
Mounting Surface mount
Case Material ABS
Warranty 1 Year Limited
CONTENTS
This package contains:
• 1 HA-III+
• 2 Mounting Screws and 2 anchors
• 1 Installation/Operating Instructions Guide HA-III+
WEEE Product Recovery/Recycling for EU Customers
In an effort to improve waste management in the European Union, the European Union has enacted
directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE Directive). According to the
WEEE Directive, Winland Electronics must take back waste electrical or electronic equipment covered
under the WEEE Directive, at its cost, for all product it puts on the market after July 1, 2006. The Return
Process: Contact Winland via our web site at www.winland.com and go to the WEEE link on the home
page. To request additional information regarding Winland’s RoHS and WEEE compliance initiative and
how it might impact your business, email [email protected].
HA-III+ Certification Info
Radio Frequency Interference Requirements: This device complies with Part 15 of
the FCC Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
CE Marking and European Union Compliance: Products intended for sale within
the European Union are marked with the CE Mark, which indicates compliance to
applicable Directives and European Norms (EN). Amendments to these Directives or
ENs are included:
Electromagnetic Compatibility Directive 89/336/EEC; RoHS Directive 2002/95/EC;
WEEE Directive 2002/96/EC
Statement of Compliance
Winland Electronics, Inc. hereby declares that this device is in compliance with all the applicable
Directives, 89/336/EEC, 2002/95/EC, 2002/96/EC.
Symbols on the Product or Manual Labeling
For product disposal, ensure the following:
• Do not dispose of this product as unsorted municipal waste.
• Collect this product separately.
• Use collection and return systems available to you.
WEEE Waste Electrical and Electronic Equipment
RoHS Restriction of Hazardous Substances
1950 Excel Drive • Mankato, MN 56001 USA
(Tech Support 8:00am - 5:00pm CST)
(800) 635-4269 • (507) 625-7231 P • (507) 387-2488 F
www.winland.com

Other Winland Electronics Accessories manuals

Winland Electronics WaterBug WBTX-319 User manual

Winland Electronics

Winland Electronics WaterBug WBTX-319 User manual

Popular Accessories manuals by other brands

Somogyi Elektronic Home TH 1000 Series instruction manual

Somogyi Elektronic

Somogyi Elektronic Home TH 1000 Series instruction manual

Medisana HKS instruction manual

Medisana

Medisana HKS instruction manual

ML Knightsbridge HBLS Installation & maintenance manual

ML

ML Knightsbridge HBLS Installation & maintenance manual

CyberPower RECON Series user manual

CyberPower

CyberPower RECON Series user manual

Elmec EVduty EVCCS user manual

Elmec

Elmec EVduty EVCCS user manual

LevelOne AVIL01W quick start guide

LevelOne

LevelOne AVIL01W quick start guide

SONBEST SM2113B user manual

SONBEST

SONBEST SM2113B user manual

Lindhaus SterilAir 30 85 27 Original instruction manual

Lindhaus

Lindhaus SterilAir 30 85 27 Original instruction manual

Mitel 112 installation guide

Mitel

Mitel 112 installation guide

inventum HN135 instruction manual

inventum

inventum HN135 instruction manual

Oracura OC010 user manual

Oracura

Oracura OC010 user manual

Asus ABTU016 user manual

Asus

Asus ABTU016 user manual

xtpower XT-400Wh user manual

xtpower

xtpower XT-400Wh user manual

OPTEX FA CD33-L Series instruction manual

OPTEX FA

OPTEX FA CD33-L Series instruction manual

ATD Tools ATD-5666 owner's manual

ATD Tools

ATD Tools ATD-5666 owner's manual

Yolink YS7704-UC user guide

Yolink

Yolink YS7704-UC user guide

EYELA LTI- 400E instruction manual

EYELA

EYELA LTI- 400E instruction manual

KITA KF02 Series instruction manual

KITA

KITA KF02 Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.