Article-No.: 50109378000 Ed. 1.0 – 032023
2. Safety instructions
Installation, commissioning, maintenance and repair must be carried out exclusively by a qualied
electrician.
• Avoid dropping or jolting. This may damage the LED module.
• Consider national and local installation requirements and classication rules.
• Observe the symbols for connecting the cables in accordance with national direc-tives:
• N = Neutral, L = Phase, = Earth, LS = Live switched.
Electrical voltage
DANGER
Danger to life from electric currents.
Work on electrical components only by a qualied electrician.
Working on open circuits can result in short circuits and body shorts.
• Make sure that the system is disconnected from the electrical connection.
• Secure the power supply against being switched on again.
• Cover open external plant components.
• If necessary, short-circuit the system components.
• Test whether the system is voltage-free.
Mounting instructions
Bolt terminal 120 mm² fo Varitain PushIn SP-VARI/WTB 120 mm²
The bolt terminal replaces defective bolt terminals (120 mm²). It is a complete assembly unit that must
be mounted and connected in the refrigerated container socket.
3. Assembly
The screws and the nuts for mounting and electrical connection are included.
4. Technical data
6. Disposal and decommissioning
Comply with the local and national laws, guidelines and regulations regarding the disposal of materials
and products.
Waste Electrical and Electronic Equipment (applicable in the European Union and other European
countries with separate collection systems.)
The electrical appliances by WISKA Hoppmann GmbH are professional electrical appliances, which are
also called business-to-business appliances (B2B). We take back old electrical appliances in accordan-
ce with the national WEEE law (i.e. in Germany § 19 ElektroG), and dispose of them properly. Please
contact
us
before
shipping
your
old
Wiska
electrical
appliances
at
[email protected].
Components,
such as cable glands, do not fall under this law.
Do not mix or dispose of old electrical equipment from WISKA Hoppmann GmbH with other commercial
waste.
WISKA Hoppmann GmbH | Kisdorfer Weg 28 | 24568 Kaltenkirchen | Germany
Phone
+49
(0)
4191
508-0
|
Fax
+49
(0)
4191
508-129
|
[email protected] |
www
.wiska.com
1
4
2
3
Specication
Voltage 440 V AC, 50/60 Hz
Rated current 32 A
Connectors Up to 10x3-p terminals (L1, L2, L3) 6 mm² each for up to 10 socket
module connectors
Installation Mounting in Varitain PushIn
Dimensions 182 x 133,5 x 88 mm (7.2 x 5.3 x 3.5 inch)
Weight 800 g (1.75 lb)
Terminal body x 1 with
Screws (M6,mounting terminal body) x 4
Cap nuts (M6) x 4
Spring washers (M6) x 4
Clamp markers x 3
Terminal locking bar x 1 with
Screws (M3,5 for terminal locking bar) x 4
Busbar x 3 with
Screw nuts (M10) x 3 (incl. washers, rotatable)
Screws (M5) x 9
Washers (M5) x 18
Screw nuts (M5) x 12
Serrated lock washers (M5) x 9
5. Scope of delivery
1 Terminal locking bar
2 Clamp body
3 Outer mounting hole
3a Inner mounting hole
4 Terminal marker
5 Busbar
3a
5