SPECIFICATIONS
Gas Supply
Installation must conform with local codes or, in the absence 
of local codes, with the National Fuel Gas Code.
Locate the gas supply within the shaded area shown in the 
illustration on the following page.
The range is equipped for use with natural or liquid propane 
(LP) gas. It is design certied by the Canadian Standards 
Association (CSA) for natural or LP gases. The product 
rating plate has information on the type of gas that should 
be used. For rating plate location, refer to the illustration 
below. If this information does not agree with the type of gas 
available, check with the local gas supplier. The gas pres-
sure regulator is built into the unit.
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
The range must be connected to a regulated gas supply. 
The supply line must be equipped with an approved external 
gas shut-off valve located near the range in an accessible 
location. Do not block access to the shut-off valve. Refer to 
the illustration below.
A gas supply line of 3/4"(19) rigid pipe must be provided to 
the range. If local codes permit, a certied, 3' (.9 m) long, 
1/2"(13) or 3/4"(19) ID exible metal appliance connector is 
recommended to connect the units 1/2" NPT female inlet to 
the gas supply line. Pipe joint compounds, suitable for use 
with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected 
from the gas supply piping system during any pressure 
testing of the system at test pressures in excess of .5 psi 
(3.5 kPa). The appliance must be isolated from the gas 
supply piping system by closing its individual manual shut-
off valve during any pressure testing of the system at test 
pressures equal to or less than .5 psi (3.5 kPa).
Wolf natural gas ranges will function up to 8,600' (2621 m) in 
altitude without adjustment. If the installation exceeds this 
elevation, contact an authorized Wolf dealer for a high alti-
tude conversion kit. LP models do not require conversion.
SHUT-OFF VALVE
OPEN POSITION
GAS SUPPLYTO APPLIANCE
 
Gas shut-off valve.
 
 
Rating plate location.
 
RATING PLATE