Wysiwash SANITIZER-V User manual

OWNER’S MANUAL
& WYSIWASH SANITIZER PRO
TABLE OF CONTENTS
...................................................03
INSTRUCTIONS: SANITIZER PRO...........................................06
MAINTENANCE INFORMATION...............................................12
FAQS...............................................................................................................13
WYSIWASH WARRANTY & RETURN POLICIES............15
SAFETY...........................................................................................................15

2
Thank you for purchasing the Wysiwash Sanitizing System! We hope you enjoy our people,
pet, & plant-safe sanitizing system.
Wysiwash is a handheld sanitizing system that attaches to a standard garden hose. Its pet
safe, eco-friendly formula is safe to use on many different surfaces to sanitize, deodorize,
place you need to clean.
Without customers like you, we would not be where we are today. If you have any questions
purchased from us directly or from a distributor, we are committed to delivering excellent
service and products.
Best regards,
The Wysiwash Team
Disinfection in 3 Simple Steps

3
A. ADJUSTABLE NOZZLE
Changes the stream emitted from a gentle mist to a
targeted stream
NOTE: The Adjustable Nozzle attaches to the long
end of the Hydro Body.
B. HYDRO SEAL
Prevents leaking by securing the Caplet
Container to the Hydro Body
C. CAPLET CONTAINER
Holds the Wysiwash Jacketed Caplets
D. HYDRO BODY
Mixing chamber that creates and measures the
Wysiwash solution
E. FLOW CONTROL VALVE
NOTE:
end of the Hydro Body.
F. FEMALE QUICK-CONNECTOR
Threads onto a standard garden hose, then attaches
WYSIWASH JACKETED CAPLETS:
The Wysiwash jacketed caplets are condensed
calcium hypochlorite—a proven disinfectant/
sanitizer
NOTE: Do NOT remove the plastic jacket from the
caplet. If the plastic jacket has been removed or
damaged, dispose of the caplet.
SANITIZER-V PARTS

4
SANITIZER-V INSTRUCTIONS
HOW TO ATTACH THE WYSIWASH SANITIZER-V TO YOUR HOSE
STEP 1:
Place caplet inside the Caplet Container. Do not remove the plastic jacket.
STEP 2:
until snug, but do not over-tighten.
STEP 3:
Thread the Female Quick Connector onto your garden hose.
STEP 4:
There is a “neck” on the front end of the Female Quick Connector that will slide back
the Female Quick Connector. Then release the neck. After, press the two parts gently
together to make sure the two parts are securely connected.
STEP 5:
Check to see if the connection is secure by pulling gently on the hose.
STEP 6:
SANITIZING WITH WYSIWASH
Turn on water to the hose.
STEP 1:
STEP 2:
PRIME: Spray into a drain or bucket to prime the system. This ensures that the solution
STEP 3:
NOTE: We recommend you wear gloves when handling the Jacketed Caplets. While the
Wysiwash solution does not irritate skin, in its solid or concentrated form (such as while
priming and draining) it can irritate eyes and skin.
NEW CAPLET: Prime for 1 - 2 minutes.
PREVIOUSLY USED CAPLET: Prime 30 - 40 seconds.

5
Draining is key to keeping your Wysiwash unit in good condition. Drain Wysiwash every time you
use it.
Either squeegee, or allow the area to completely air dry.
STEP 6:
DRAINING THE WYSIWASH SANITIZER-V
becoming airborne. To adjust the spray, twist the sleeve on the stem of the Adjustable
Nozzle.After the whole area has been sprayed with a gentle mist, use the jet spray on
heavily soiled areas to remove any remaining organic waste.
STEP 4:
Allow Wysiwash to set for 2 minutes.
OPTIONAL RINSING: For uncoated metal or high gloss surfaces, we recommend rinsing.
STEP 5:
STEP 1:
the female toward the hose side again to release.
STEP 2:
upside down and point the valve downward.
STEP 3:
solution to drain. The bottom of the Caplet
Container, should be pointed upwards at a
slight angle. This allows water to drain from
the bottom of the Caplet Container.
STEP 4:
STEP 5:
NOTE: Take caution to avoid contact with skin and clothing while draining. The drained solution is more
concentrated and may stain/irritate skin. Rinse the area where Wysiwash has been drained to avoid
calcium spots.
SEE THE VIDEO ON WYSIWASH.COM

6
A. ADJUSTABLE NOZZLE
Changes the stream emitted from a gentle
mist to a targeted stream
NOTE: The Adjustable Nozzle attaches to
the long end of the Hydro Body.
B. HYDRO SEAL
Prevents leaking by securing the Caplet
Container to the Hydro Body
C. CAPLET CONTAINER
Holds the Wysiwash Jacketed Caplets
D. HYDRO BODY
Regulates and mixes the water that goes
into the caplet container
G. NOZZLE-END FEMALE QUICK CONNECTOR
Attaches the Wysiwash Hydro Body to the
Sanitizer Pro Handle
H. PRESSURE LEVER
Adjusts the water pressure
I. HYDRO BODY CONNECTOR
Attaches to the Hydro Body and connects
with the Nozzle-End Female Quick Connector
NOTE: The Hydro Body Connector attaches
to the short end of the Hydro Body.
J. TRIGGER RELEASE BUTTON
Press to unlock the trigger and stop the
K. HANDLE TRIGGER
automatically locks for easy sanitizing
L. HOSE-END FEMALE QUICK CONNECTOR
Connects the Sanitizer Pro to a standard
garden hose
M. MALE NIPPLE
Connects the Sanitizer Pro Handle to the
Hose-End Female Quick Connector
N. DETACHABLE PRO NOZZLE
Attaches to the Sanitizer Pro Handle to pro-
vide pressurized fresh water
SANITIZER-PRO PARTS
JACKETED CAPLETS:
The jacketed caplets are concentrated calcium hypochlorite—a proven disinfectant/sanitizer.
NOTE: DO NOT remove the plastic jacket from the caplet. If the plastic jacket has been removed or
damaged, dispose of the caplet.

7
SANITIZER-PRO INSTRUCTIONS
CONVERTING A SANITIZER-V TO A SANITIZER PRO
If there is calcium build up on your Hydro Body or Caplet Container, we recommend
you remove it before attaching Sanitizer Pro parts. See page 12 for instructions on
removing build up.
OPTIONAL:
Remove the original Adjustable Nozzle (Part A).
STEP 1:
Attach the new Electroless Nickel Adjustable Nozzle (Part A) to the long end of the
Hydro Body (Part D).
STEP 2:
STEP 3:
Attach the Hydro Body Connector (Part I) to the short end of Hydro Body (Part D).
STEP 4:
ATTACHING THE SANITIZER PRO TO A STANDARD GARDEN HOSE
Pull down on the neck of Hose-End Female Quick Connector (Part L).
STEP 1:
With the neck down, pull the Handle away from the Hose-End Female Quick Connec-
tor (Part L).
STEP 2:
Thread the Hose-End Female Quick Connector (Part L) onto a standard garden hose.
STEP 3:
Pull back the neck of the Hose-End Female Quick Connector (Part L).
STEP 4:
With the neck back, press the Male Nipple (Part M) into the Hose-End Female Quick
Connector (Part L).
STEP 5:
SEE THE VIDEO ON WYSIWASH.COM

8
ATTACHING THE PRO HANDLE TO THE WYSIWASH HYDRO BODY
Take the Pro Handle and pull back the Nozzle-End Female Quick Connector (Part G).
STEP 1:
With Part G pulled back, press the Hydro Body Connector (Part I).
STEP 2:
Release the Nozzle-End Female Quick Connector (Part G). The Pro Handle and Sanitizer
Pro should lock together.
STEP 3:
Ensure the connection is secure by gently pulling the Hydro Body and the Pro Handle
away from one another.
STEP 4:
SANITIZING AND SPRAYING
Turn your hose on (water will not be released until you squeeze the trigger of the
Sanitizer Pro).
STEP 1:
Select the desired pressure by turning the Pressure Lever (Part H). You can also adjust
the pressure while spraying.
STEP 2:
OFF: TURNED DOWN
MEDIUM PRESSURE:
FULL PRESSURE: POINTING UPWARDS
Press the trigger (Part K) to start sanitizing. The trigger will lock automatically.
To adjust the spray from fan to jet, use the adjustable nozzle (Part H).
STEP 3:
To release the trigger, push the Trigger Release Button (Part J).
STEP 4:
SWITCHING TO FRESHWATER MODE (OPTION A)
Turn off the Wysiwash Sanitizer by pressing the Trigger Release Button (Part J). Do
not switch from Sanitizing to Freshwater Mode while the Wysiwash solution is being
emitted.
STEP 1:
BEST FOR:
When you want increased pressure over your regular hose and to use fresh water only.

9
Place the Wysiwash Sanitizer over a safe draining area. Tilt the adjustable nozzle (Part A)
upwards so that the liquid can drain through Hydro Body Connector (Part I).
STEP 3:
Attach the Detachable Pro Nozzle (Part N) to use fresh water.
STEP 4:
Detach the Wysiwash Sanitizer from the Pro Handle with the Adjustable Nozzle (Part
A) pointing down.
STEP 2:
CAUTION: The solution inside the Wysiwash Sanitizer is concentrated and can stain. Take care to avoid
contact with skin and clothing. spots.
SWITCHING TO FRESHWATER MODE (OPTION B)
If you do not need additional pressure or you are not ready to drain the Wysiwash Sanitizer Pro yet,
you can remove the Wysiwash Sanitizer Pro from the hose.
Turn hose off.
STEP 1:
Pull back on the Hose-End Female Quick Connector (Part L) to detach the Pro Handle
from the hose.
STEP 2:
STEP 3:
DRAINING
Disconnect the Hydro Body from the Pro Handle by pulling the Nozzle-End Female
Quick Connector (Part G).
STEP 1:
Point the Adjustable Nozzle (Part A) downward. This prevents the concentrated solution
that remains in the system from spilling.
STEP 2:
With the nozzle downward, pull back the Nozzle-End Female Quick Connector (Part G)
to disconnect the Pro Handle.
STEP 3:
BEST FOR:
When you do not need additional pressure. (For example, watering plants.)
When you are not ready to drain yet, and want to switch back to sanitizing quickly. (For example:
rinsing off a piece of metal equipment before continuing to sanitize.)
SEE THE VIDEO ON WYSIWASH.COM

10
uses. With the jacket left on the caplet and the Wysiwash Sanitizer properly drained, the caplet
will remain solid.
The best way to store your Wysiwash Sanitizer is to place it upside down, with the Male End
pointing down at an angle. This allows it to continue draining and maximizes the life of the
caplet. Put a plastic or glass tray or bowl under it to catch any additional drips.
Remove the Pro Handle before storing the Sanitizer Pro.
STORING WYSIWASH EQUIPMENT
Over a bucket, drain into sink, tilt the Adjustable Nozzle
(Part A) upwards, so that the Sanitizer drains.
STEP 4:
NOTE: The drainage is highly concentrated and can
stain clothes. If skin comes in contact with the drain
solution, rinse skin immediately.
NOTE: Make sure to drain before storing your Wysiwash Sanitizer (see pages 5 & 9).

11
IMPORTANT INFORMATION
DO NOT USE WITH AMMONIA BASED PRODUCTS
Ammonia and chlorine-based cleaning products should never be combined. In the event that an
accidental mixture occurs, immediately evacuate all people and animals from the area and call
local emergency services.
WATER PRESSURE & PRESSURE SURGES
Water pressure over 70 psi can damage Wysiwash equipment. This includes water pressure surges
(water hammer) that exceed 70 psi.
HARD WATER
monthly. (See “Build Up” for instructions.)

12
TROUBLESHOOTING & MAINTENANCE
BUILD UP
Over time, spots of calcium (hardened white patches) may build up on your Wysiwash Santizing
System. (Sometimes people call this corrosion, but it is actually built up calcium.) These calcium
build ups can clog your sanitizer and cause it to malfunction.
To remove build up or clogs, simply follow these steps:
Open the Caplet Container and remove the caplet from unit. You can store the caplet
in a safe, plastic container.
STEP 1:
STEP 2:
Leave the Caplet Container disconnected from the rest of the Wysiwash Sanitizer, then
soak the unit in white vinegar overnight (8 - 14 hours).
STEP 3:
To maximize the life of your unit, soak the unit monthly.
STAINING OR “BLEACHING” OF FABRICS
At its sanitizing concentration, Wysiwash does not stain. After speaking with many customers,
with proper protocols.
The most common cause of staining is skipping draining. Draining should be done every time
to avoid the solution that drains out.
and prime Wysiwash for 60 seconds before continuing with normal sanitizing procedures.
LOOSE CONNECTION: SANITIZER PRO HANDLE
If water is spraying out from where the hose connects to the Sanitizer Pro Handle, you may need
to tighten the Male Nipple (Part M). To tighten, hold the top of Part M steady, while using a padded
wrench/pliers to turn the bottom of Part M clockwise. Tighten snugly but do not overtighten!

13
FREQUENTLY ASKED QUESTIONS
DO I NEED TO REMOVE THE JACKET FROM THE TABLET BEFORE USING THE WYSIWASH SANITIZER?
No! Do not remove the jacket from the Wysiwash Sanitizer Jacketed Caplet before using it. The
jacket does several things and is integral to the operation of the Sanitizer.
HOW LONG WILL A CAPLET LAST?
When drained properly when not in use, a Wysiwash Jacketed Caplet will last for approximately 3.5
hours.
HOW DO I KNOW WHEN TO CHANGE CAPLET?
-
taching it to your hose. If you hear or feel caplet clunk inside the Caplet Container, you are ready to
disinfect. Inspect visually as needed. If you don’t hear it, open the Caplet Container, put on gloves,
discard plastic jacket, and insert new caplet.
DOES THE WYSIWASH SANITIZING SYSTEM GENERATE FUMES?
The Wysiwash Sanitizing Solution generates some fumes, albeit many fewer than most sanitizers
and disinfectants. Like most cleaning products, the Wysiwash Sanitizing System should be used
in areas with adequate ventilation. A good rule of thumb is that if you wouldn’t use bleach due to
lack of ventilation, then you should increase ventilation before using Wysiwash.
Most users report that Wysiwash is more pleasant than other disinfectants, especially liquid
bleach.
IS IT SAFE TO HAVE SKIN CONTACT WITH SURFACES THAT HAVE JUST BEEN SPRAYED WITH
WYSIWASH?
Yes, the Wysiwash Sanitizing Solution is mild but highly effective.
CAN I USE WYSIWASH SOLUTION TO RINSE DOWN DEGREASERS OR OTHER CLEANERS?
It is completely safe to rinse down degreasers and soaps that are labeled as safe for use with chlorine
products or oxidizers.
Do not use with ammonia products and products that are not compatible for use with chlorine.
For more FAQs, visit https://www.wysiwash.com/faqs.

14
CAN I USE WYSIWASH WITH AMMONIA-BASED PRODUCTS?
No. It is extremely dangerous to use Wysiwash (or any chlorine product) with ammonia. If you
have used ammonia products in the past, be sure to rinse them thoroughly and let the area dry
completely. Wait for all surfaces to dry. If any ammonia fumes are present, rinse again and allow to
dry before using Wysiwash.
WILL WYSIWASH DAMAGE METAL SURFACES?
Avoid spraying copper, brass or metals prone to oxidation.
For other metals, Wysiwash will affect metal like regular water, if the Wysiwash unit is drained and
used according to directions.
CAN I STORE A BUCKET OF WYSIWASH JACKETED CAPLETS OUTSIDE OR IN MY GARAGE?
We do not recommend storing Jacketed Caplets outside, in garages, or any other area that is likely
cool and temperature controlled environment with good ventilation. Do not expose to high
Learn more about proper storage on page 10.
IF I DON’T USE MY CAPLETS FOR AN EXTENDED TIME, ARE THEY STILL EFFECTIVE?
Absolutely! The Wysiwash Sanitizer Jacketed Caplets have an extended shelf life, losing only 3%

15
Please note that SDS & WYSIWASH Jacketed Caplet package warnings refer to the concentrated Wysiwash
Jacketed Caplets, NOT THE WYSIWASH SOLUTION THAT THE WYSIWASH SANITIZER PRODUCES AND
SPRAYS. The Wysiwash Solution is safe to use around humans, animals, & plants.
The Wysiwash Solution is mild, and non-irritating, and safe to use around people, pets, and plants. However, we
do not recommend extended contact with the solution. Avoid contact with skin and clothing while priming
and draining.
ANIMAL SAFETY
To ensure animal safety and prevent undue stress, always take animals to a separate area before you begin
spraying.
WYSIWASH WARRANTY
Wysiwash warrants this product against defects in materials or workmanship for a period of one year from
the date of purchase, if used according to directions and is not damaged from neglect, misuse, or accident.
If product is found to be defective, return product with proof of purchase to Wysiwash. Wysiwash will repair,
replace, or refund the purchase price. WYSIWASH assumes no responsibility for misuse, accidents or damage
caused by the operator of a WYSIWASH Sanitizer.
WEAR ITEMS (PARTS)
Wear Items are parts that will wear out through use and over time. If the user exercises care when using the
like frequency of use and user care.
RETURNS
(less all shipping charges) for all merchandise returned to us within 30 days of purchase that does not meet
your satisfaction.
Simply contact us by phone (866) 627-6284 or email: contact@wysiwash.com and let us know the problem
you experienced with the merchandise. We will then issue you a Return Merchandise Authorization Number
(RMA) and special instructions for returning the product(s) to us. Your account will be credited upon return of
the goods.
Wysiwash Jacketed Caplets and any chemical purchases are non-refundable
SAFETY NOTES

Got questions? Call us at (866) 627-6284
or email contact@wysiwash.com.
Wysiwash Jacketed
Caplets 9-Pack
WYS-117
Caplet Container
WYS-111
Hydro Body
WYS-108
Zinc-Coated Adjustable
Spray Nozzle
WYS-118
Female Quick
Connector
WYS-104
Male Quick Connector
WYS-105
Sanitizer Pro Conversion
Kit
WYS-228
Male Female Quick
Connector Set
WYS-116
WYS-109
Hydro Seal
WYS-115
Sanitizer Pro Hose-End
Female Quick Connector
WYS-204
Sanitizer Pro Hydro
Body Connector
WYS-207
Sanitizer Pro Adjustable
Nozzle
WYS-218
Visit Wysiwash.com or Call (866) 627-6284 to Order Parts.
This manual suits for next models
1
Table of contents