Do not use the massage gun on the head, face, elbows, knees and other
joints, spine or other bony areas with minimal muscle coverage.
Do not use the massage gun on the sides, front or back (cervical vertebrae)
of the neck to avoid damages to the carotid sinus. Otherwise, it could
lead to fainting and cardiac arrest.
Do not use the massage gun on the underarms, the inside of upper arm,
the inner side of clavicle, the inside of elbow, the back of knee, the abdomen,
the kidney area, the genitals or other fragile areas with dense nerves
and blood vessels.
Do not use the massage gun below the abdomen of persons with urinary
diseases, such as kidney stones, ureteral stones, bladder stones, urethral
stones, urinary tract infections, etc.
Do not use the massage gun on the body areas with bruises or pain, surface
wounds, local fever, red swelling or discomfort, inflammation, muscle
spasms, muscle lacerations, acute sprains, contusions, and strains.
Do not use the massage gun if symptoms such as fever, nausea, vomiting,
Do not use the massage gun on persons with the following diseases:
cardiovascular and cerebrovascular diseases, blood diseases, coagulation
disorders, thrombocytopenic purpura, neck plaque, varicose veins,
venous thrombosis, cancer, tumors, and mental illness.
Do not use the massage gun on persons with fractures or metal implants.
Do not use the massage gun while driving or conducting precise operations.
Do not use the massage gun continuously for a prolonged period of
time, so as to prevent muscle damage caused by excessive massaging.

Do not place fingers, hair or other parts of the body near the joint between
the massage head and the muzzle of the massage gun during operation to
avoid being pinched.
Do not block or insert foreign objects into the massage head groove or
charging port. Otherwise, this may cause burns or electric shocks, or cause
a fire due to a short circuit.
Do not immerse the massage gun in water or other fluids.
Do not use the massage gun in humid environments.
Charge and use it under an ambient temperature of 0°C to 35°C.
Keep the massage gun away from sources of water and fire, as well as
yourself.
Do not use the massage gun while charging.
Please use the original power adapter and original charging cable to
charge according to the specifications in the user manual.
Charge the massage gun before use if it has not been used for a long
period of time.
The massage head is partly made of silicone. For people allergic to
silicone, please do not use the round head and the U-shaped head,
and the flat head is recommended.

This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
obtaining permission.
Women who are pregnant or who have just given birth.
People who are 60 years old and above.
People with rhabdomyolysis.
People with missing limbs or paraplegics.
People with heart pacemakers or stents.
People who have undergone surgery within the past 12 months.
People with impaired limb perception or mobility due to disease or age.
People with abnormal spine, joints or bones, or who suer from orthopedic
diseases such as osteoporosis, cervical spondylosis and lumbar disc
herniation.
People with any disease-related complications (such as neuropathy or
retinal damage).
People with urinary diseases such as kidney stones, ureteral stones,
bladder stones, urethral stones or urinary tract infections.

damage the components or cause abnormal operation. If the above occurs,
Continuous use of the massage gun over a long period of time may cause
a rise in its surface temperature, which may cause damage to it. Do not
use it too long at a time.
In the event the massage gun heats up, emits smoke or buzzes excessively,
service team.
WARNINGS
The following steps should only be completed upon the permanent disposal of
the massage gun. Do not dismantle the massage gun on your own for routine
maintenance.
1. Disconnect the massage gun from the power supply and remove the shell.
environmental protection laws, regulations and guides when doing so.
CAUTIONS
Disconnect the massage gun from the power supply before removing the
The massage gun must only be dismantled by a professional.

Relieve muscle soreness or stiness in the back and shoulders caused
Help muscles relax through daily massage.

Round head: Suitable for massaging larger muscle groups such as
shoulders, waist, arms, hips, thighs, and calves.
U-shaped head: Suitable for massaging the back, the sides of the spine
and calves.
Flat head: Suitable for relaxing all muscles.
Illustrations of product, accessories, and user interface in the user manual
are for reference purposes only. Actual product and functions may vary due
to product enhancements.

When disassembling the massage head, hold the massage head and rotate
it counterclockwise while pulling upward from the muzzle.
The red line in the figure is the schematic line for installation, while it is a
glossy surface on the actual product.
Please install and disassemble the massage head when the massage gun
is turned o, and ensure that the massage head is installed firmly before
turning on the massage gun. Do not adjust, install or remove the massage
head during use to avoid being pinched.
Install an appropriate massage head for the desired type of massage.
When installing the massage head, push the massage head base into
the muzzle of the massage gun with force, ensuring that the line on
the head is flush with the muzzle.

Turning on:
indication mark will be exposed now), the three speed indicators will light
o at the same time, and the speed 1 indicator will remain on. The massage
turn o if there is no operation for 10 minutes. Manually push the on/o
Turning o:
indicator for the current speed will go out, and the massage gun will turn o.
Adjusting speed:
correspond to three dierent speeds: Speed 1, Speed 2 and Speed 3.
Pausing:
use. The massage gun will automatically turn o if it is not used for 10 minutes
the massage gun.
If the pressure is too high, the massage gun will
massage gun with speed 1 by default.
Turn o the massage gun, plug the charging cable into the charging port,
and then connect to a power supply. The massage gun cannot be turned
on while charging.
If the charging cable is connected to a power supply and plugged into the
charging port of the massage gun while it is on, the massage gun will
automatically turn o and start charging.

If the light ring is not on, it means the massage intensity is low and mild
massaging eect is applied. Intensity can be adjusted according to user
needs.
If the light ring is white, the massage intensity is moderate and normal
massaging eect is applied. Intensity can be adjusted according to user
needs.
If the light ring is orange, the massage intensity is high. Intensity can
be adjusted to user needs, so as to avoid harming the muscle due to
excessive pressure.
Speed Indicators
The speed indicators correspond to Speed 1, Speed 2 and Speed 3
from
corresponding indicators will be lit up in white.
Pressure Sensor Indicator

Install an appropriate massage head, turn on the massage gun and select
a suitable speed according to personal experience. It is recommended to
start at a low speed.
Gently press the massage head against the muscles that need relaxation
and move slowly back and forth. If there is a particularly sore area, apply
an appropriate pressure at the point that feels tender and keep it there
for 15–30 seconds.
The massage gun has a pushing force, and thus it is not advisable to use
excessive force when applying pressure, so as not to harm muscles or
bones.
It is recommended to use on areas with adequate muscle coverage, and
to not stay in the same area for more than 60 seconds.
The recommended usage duration is 10 minutes. If soreness is still felt,
the massage time can be extended appropriately.
The recommended duration of a single use should not exceed 15 minutes,
and the duration of continuous use should not exceed 30 minutes.
Breathing in white: Charging.
disconnect from the power source. If charging the massage gun
20 seconds.
Charging Indicator

Wipe the massage gun and massage heads regularly with a clean, slightly
Do not rinse in water or expose the massage heads to direct sunlight.
When cleaning, make sure the massage gun is turned o and unplugged.
Do not use corrosive liquids to clean the massage gun, as this may
damage or crack the massage gun or change its color.
Store the massage gun in a cool, dry place.
Do not store the massage gun in an environment above 40°C or below
-10°C. Keep it away from moisture, sources of water or fire, or corrosive
The massage gun can be put in the supplied storage case for storage or
travel.
Do not hit, squeeze, drop, throw, or scratch the massage gun.
The massage gun can be transported in cars, trains, ships, and planes. It
should be secured in place facing upwards to prevent damage from
squeezing, vibrations, collisions, rolling, or falling during transport.
Charge the massage gun before use if it has not been used for a long
period of time.
If the massage gun becomes overheated or deformed, swells, or the

The indicator
does not light
up while
charging.
The power adapter is not
properly connected to the
massage gun.
Make sure the power adapter is
plugged in correctly.
The massage gun can be used
normally.
temperature returns to normal,
then resume use.
Charge the massage gun before
use.
Restart the massage gun.
service team to arrange
maintenance.
service team to arrange
maintenance.
Wait for the temperature of the
massage gun to return to normal
before resuming use. The
recommended duration of a single
use should not exceed 15 minutes,
and the duration of continuous
use should not exceed 30 minutes.
The charging indicator goes
massage gun is fully charged.
A foreign object has entered
the motor.
There is a motor error.
Usage time is too long.
too high or too low.
The massage gun is out of
The massage gun
experiences block & stop
due to excessive pressure.
charges slowly.
The massage
gun does not
work.
The motor
makes
abnormal
noises.
The massage
gun's
temperature
is too high.

We, Zhuhai Yunmai Technology Co., Ltd., hereby declare that
this equipment is in compliance with the applicable Directives
and European Norms, and amendments. The full text of the EU
declaration of conformity is available at the following internet
-
tion.html
All products bearing this symbol are waste electrical and
electronic equipment (WEEE as in directive 2012/19/EU) which
should not be mixed with unsorted household waste. Instead,
you should protect human health and the environment by
handing over your waste equipment to a designated collection
point for the recycling of waste electrical and electronic
equipment, appointed by the government or local authorities.
Correct disposal and recycling will help prevent potential
negative consequences to the environment and human health.
Please contact the installer or local authorities for more
information about the location as well as terms and conditions
of such collection points.

Manufactured for: Xiaomi Communications Co., Ltd.
Manufactured by: Zhuhai Yunmai Technology Co., Ltd.
(a Mi Ecosystem company)
Address: Unit 1201-1203, Youte Headquarters Building, No. 88 Xingye
Road, Xiangzhou District, Zhuhai, Guangdong, China
For further information, please go to www.mi.com
User Manual Version: V1.0
Importer:
Beryko s.r.o.
Pod Vinicemi 931/2, 301 00 Plzeň
www.beryko.cz
This manual suits for next models
1
Other Xiaomi Massager manuals
Popular Massager manuals by other brands

Osaki
Osaki OS-PRO Maestro installation manual

Sharper Image
Sharper Image 206045 owner's manual

Comfier
Comfier CF-4803 user manual

truMedic
truMedic InstaShiatsu+ FC-1500 instruction manual

Vitalmaxx
Vitalmaxx NVSC-4/0716 instruction manual

HoMedics
HoMedics iCush-100 Instruction manual and warranty information

Brookstone
Brookstone OSIM uAstro user manual

HYPERICE
HYPERICE Hypervolt Go 2 operating instructions

Seating Matters
Seating Matters DENVER Operation manual & product specification

Comfier
Comfier CF-1228 user manual

HoMedics
HoMedics Compact Pro Spa FB-350 instruction manual

Bio-Medical Research
Bio-Medical Research Tummy Lift instruction manual