XP Aqua Ultimate ATO User manual

Aquarium Experts
Model
UATO-400P
Manual
Ultimate

1
Aquarium Experts
The Ultimate ATO is the world’s first quad-sensor ATO; with
one sensor for top-off detection and two sensors for overfill
detection. It also features a non-filling / run-dry detection
sensor; which is also a first in any aquarium ATO.
For your convenience, we include an AC Switch for
installations that require more-powerful pumps and a
Solenoid Valve for installations that connect directly to
RO/DI systems.
The Ultimate ATO provides the ultimate protection as well as
the ultimate convenience. The system is designed to be
plug-and-play and make installation as easy as possible.
These instructions will guide you through the various
installation options and well as explain the how the system
will operate.
Thank you again for choosing XP Aqua!
Thank you for purchasing the XP Aqua Ultimate ATO.

2
Aquarium Experts
Item Picture Description
UltimateATO
Controller
Module AutoTopOffwith2xDualSensors
UniversalATO
TubingHolder
Forrimmedorrimlessaquariums
upto1/2inch(12.7mm)
UniversalPower
Supply UniversalPowerSupply:110V-240V
List of Parts
Head:8.2feet(250cm)
ATODCPump
SiphonBreak Aconnectortobreakthesiphon
Tubing6.5feet
(200cm) UsedwithATODCPump
ROSolenoidValve ForusewithRO/DISystems
ACSwitch ForconnectingwithACpumps
(10AMax.)

3
Aquarium Experts
Ultimate ATO Controller Module
Controller & Accessories
2
1
1.ControllerBracket
2.UltimateATOController
3.SecondaryOverfillProtectionSensor
4.PrimaryOverfillProtectionSensor
5.ATOLevelDetectionSensor
6.Non-filling/RunDryProtectionSensor
7.SensorHousing
10
8
9
8.DrySideMagnet(Yellow)
9.DrySideMagnet(Blue)
10.MagnetHousing
3
7
5
6
4
Caution:
RiskofInjuryfromStrongMagnets

4
Aquarium Experts
I. Installation with Sensor Housing (Standard Installation)
Installation
1Mountthesensormoduletothesumpwiththemagnet.
Movethesensortothenormalwaterlevelwiththewaterlevelreachingthe
upperbluesensor.
ConnectATOrefilltube(pump↔siphonbreak↔tubingholder).
ConnectbothoftheDCpumpandpoweradapterwiththecontroller.
*Pleaseavoidsettingupthesensorinanareawithmicrobubblesordirectlight.
2
3
4
Reservoir Tank/Sump
ATODCPump
Power
OpticalLevelSensor
1
4
3
2
AirIn Direction
Siphonbreakmustbehigherthanthewater
levelinthereservoir.
AirIn:Siphonbreakallowsairintobreakthe
siphonwhenthepumpturnsoff.
WaterOut:Waterdropsoutoftheholeare
normalwhenthepumpison.
WaterOut

5
Aquarium Experts
II. Installation without Sensor Housing (Optional Installation)
Reservoir Tank/Sump
ATODCPump
Power
OpticalLevelSensor
1
2
3
4
Mountthebluedualsensoratthenormalwaterlevelonthetank/sump.*
Mounttheyellowdualsensoratthedesiredsafetylevelonthetank/sump.
ConnectATOrefilltube(pump↔siphonbreak↔tubingholder).
ConnectbothoftheDCpumpandpoweradapterwiththecontrollerand
thenconnectpower.
*Pleaseavoidsettingupthesensorinanareawithmicrobubblesordirectlight.
1
2
3
4
ForsumpswithEXTREMEwaterlevelfluctuations.
AirIn Direction
Siphonbreakmustbehigherthanthewater
levelinthereservoir.
AirIn:Siphonbreakallowsairintobreakthe
siphonwhenthepumpturnsoff.
WaterOut:Waterdropsoutoftheholeare
normalwhenthepumpison.
WaterOut

6
Aquarium Experts
III. AC Switch Installation (Using AC Pumps)
Thisoptionisperfectforaquariumsthatrequirealarger/strongerATOpump.
SimplyusetheACSwitchinplaceofthesuppliedDCpumpandpluginyour
ownATOpump(10AMax.)intotheACSwitch.
Reservoir Tank/Sump
ACRefillPump
Power
OpticalLevelSensor
ACSwitch

7
Aquarium Experts
IV. Solenoid Valve Installation
CutthetubingbetweenthecarbonblockfilterandtheROmembrane.Install
thesolenoidvalve.
*Arrowonsolenoidvalveindicateswaterflowdirection.
a. RO/DI System without Auto Shut Off (Installation Option 1)
¼”pipefrom
pre-filtration
system
Solenoid
Valve
Note:Filteredwaterisrequiredtopreventsediments
fromcloggingthesolenoidvalve.Donotinstallthe
solenoidvalvebeforeyourfiltrationsystem
RO
Membrane
¼”pipeto
ROinlet
Feedwater
input
SedimentCarbon
Tank/Sump/Reservoir
DIFilter
ROWaste
ConnectthesolenoidvalveattheRO/DIoutput.
ThisoptioncanbeveryhelpfulwhentheRO/DIsystemisremotelylocated.
*Arrowonsolenoidvalveindicateswaterflowdirection.
b. RO/DI System with Auto Shut Off (Installation Option 2)
Tank/Sump/Reservoir
1/4”pipefrom
RO/DIoutlet SolenoidValve

8
Aquarium Experts
Housing
Installation
a. Dismantling the Housing
b. Assembling the Housing
1.Placetheyellowdualsensorintheupperpositionofhousingwhiletheblue
oneinthelowerposition,andputthecoverandthesensorhousingtogether.
2.Placetheyellowandbluemagnetinthemagnethousingwiththelogofacing
thecover.Putthecoverandthemagnethousingtogether.
1.Removethecoveroffthesensorhousing.Takeoutthesensors.
2.Removethecoveroffthemagnethousing.Takeoutthemagnets.

9
Aquarium Experts
LED Indicator
LEDColor Description Action
Status
Solid Poweron N.A.
Circulating Refilling/Pumping N.A.
BlueLED Pulsinglight Detectiondelayof
safetysensors N.A.
Alternating
&Blue
LEDOrange *
Flashingwith
shortbeeps
QSTalarm:
1.Bubble
interference
2.Emptyreservoir
1.Movetheupperblue
sensortoanareaaway
frommicrobubbles.
2.Refillthereservoir.
Flashingslowly
withshortbeeps
Non-fillingalarmof
Non-filling/RunDry
ProtectionSensor
1.Keepthebluesensor
clean.
2.CheckiftheATO
functionproperly.
*Pleasefollowtheinstructionabovetofixissuesandthenreset
(unplugthepowerandplugitbackin).
LEDOrange
1.Checkiftheupper
bluesensorfunction
properly.
2.Checktheset-upof
siphonbreakandtubes.
3.Takeouttheyellow
dualsensortocheckif
theyellowsensors
functionproperly.
Flashingquickly
withlongbeeps
Overfillalarmof
SecondaryOverfill
ProtectionSensor
Flashingquickly
withshortbeeps
Overfillalarmof
PrimaryOverfill
ProtectionSensor
Flashingwith
shortbeeps
Pumpconnection
failure
Checktheconnection
ofthepumpandthe
controller.

Aquarium Experts
10
Allthesafetysensors(thelowerbluesensorsandtheupperyellowsensors)
havedetectiondelaysof3minutesaftertheATOsystemisplugged-in.Ifyou
wouldliketoskipthedelay,pressthecenterbuttononthecontrollertoallow
thesensorstodetectthewaterlevelimmediately.
UltimateATOusesQSTforreal-timeprotectionagainstanyfailuresituation.
Thecontrollerwillgiveanaudibleandvisualalertwhenitsensesanyother
refillingtimeis6timeslongerthanthefirstrefillingtime .Forexample,ifthe*
firstrefillingtimeis10sec,itwillalertwhenanyotherrefillingtimeisover
60sec.
*Nosecuritytimecontrolforthefirstrefilling.
Touchbutton:
1.Skipthe3-minutedetectiondelayofsafetysensors.
2.Switchoffthealarm.
*TouchthebuttonwillnotcleartheQSTmemory.
Pleaseunplugthepowerandplugitbackintoclear
theQSTmemory.
Detection Delay of Safety Sensors
Touch Button
Quick Security Technology (QST)
Specifications
1.PowerInput:100-240VAC50-60Hz
2.DCPump:
•Head:8.2ft(250cm)
•FlowRate:74gph(280lph)
3.MaxMountingThickness:1/2inch(12.7mm)
4.ACSwitch:
•Capacity:100-240VAC50-60Hz
•Max.Load:10A/1200W@120VAC;10A/2400W@240VAC
5.SolenoidValvePowerConsumption:6W@12VDC

Aquarium Experts
11
Limited Warranty Policy
1.LimitedwarrantyisprovidedbyXPAquaonlyifyourXPAquaProduct
("Product")waspurchasedfromanauthorizeddistributororanauthorized
reseller.Thislimitedwarrantyisnottransferable.
2.Allwarrantyrepairsorreplacementareperformedbytheauthorized
distributororauthorizedresellerintheregionwheretheProductwasfirst
shippedbyXPAqua.
3.Thelimitedwarrantyisvalidforaperiodof1yearunderproperinstallation
andnormalusefromthedateoftheoriginalpurchaselistedontheproofof
purchaseorsalesreceipt.
4.Intheeventofalimitedwarrantyclaim,proofofpurchaseorsalesreceipt
(issuedtotheoriginalpurchaser)isrequired.
ExpertAquaCo.,Ltd.
service@xpaqua.com
www.xpaqua.com
(Y/M/D)
Storename/phone/email/address
PlaceofPurchase
PurchaseDate WarrantyPeriod
Oneyearfromthepurchasedate
Service
This manual suits for next models
1
Table of contents
Popular Accessories manuals by other brands

Met One Instruments
Met One Instruments 085 manual

PCB Piezotronics
PCB Piezotronics 393B04 Installation and operating manual

Clifford
Clifford Sense and Tell 4 owner's guide

Henry Engineering
Henry Engineering MULTIPORT manual

Burkert
Burkert 8220 operating instructions

Dräger
Dräger PID 5000 Instructions for use