xpr EX5 User manual

EX5 EX5P
: Standalone Keypad
: 99 User Codes
: Input Voltage
12/24V AC/DC
:Switching Regulator
: Current consumption :
Standby 30mA,
maximum 130mA.
: Standalone Keypad with Integrated Proximity
: Reads EM Cards, with Read range 3-12 Cms
: 99 User Codes/Tag
:
: Double Security with Code + Tag or Tag + Tag
:
:
Single Security with Code or Tag
Input Voltage 12V AC/DC
Linear Power supply.
: Current consumption : Standby 20mA,
maximum 180mA.
Common
: Backlit keys (metal / plastic)
: User Code length:1- 8 digits
: 2 relays (R1: 10A/24V DC /120V AC; R2: 2A/24V DC/120AC)
: 2 Push buttons to operate relays
: Entry codes can be programmed to activate either one of the relays
or both relays together
: 2 Free tension LEDs Red & Green
: Yellow LED (and buzzer sound) indicates Key Press function
: 30 sec lockout after 8 invalid codes
: Additional slave readers can be connected via bi directional CODIX bus
: EEPROM prevents data loss during power failure
EX5 EX5P
:
:
: Fonctionne sur
12/24V CC/CA
:
Clavier autonome
99 codes d'utilisateur
Consommation au
repos: 30mA,
Maximum: 130mA
Régulateur de
commutation
:
: Clavier autonome avec lecteur de
proximité intégré
: Lecture badges EM (3-12 Cm)
: 99 badges/code utilisateurs
: Simple sécurité : code ou badge
: Double sécurité : code + badge ou
badge + badge
: Fonctionne sur 12V CC/CA
:Alimentation linéaire
:Consommation au repos:20mA, Maximum:180mA
Commun
: Touches retro-éclair'ees (metal / plastique)
: Longueur du code utilisateur : 1 à 8 digits
: 2relais, (1x10A, 1x2A) en mode marche /arret(00) ou impulsionnel
(01 'a 99sec)
: 2 boutons de sortie
: Possibilité d'assigner le relais 1 et/ou relais 2 à un code utilisateur/badge
: 2Led libres de tension (rouge et verte)
: Led jaune d'indication avec sonorisation
: 30 sec de verrouillage après 8 codes incorrects
: Possibilité de raccorder des lecteurs ( à code / proximité ) via le bus CODIX
: Memoire EEPROM sauvegarde Les donnees
Mounting Montage
UK FR
1. 2. 4.
Cable
Cable
Ø6.0
30mm
Cable
Cable
Ø6.0
30mm
43B 3.
7.
3 (8 x 30 CSK)
5. 6. 8.
2 (M3 x 6mm)
security screw
1. 2. 3. 4.
5
5
EX5: 52B / 52G /72C EX5P: 53B /53G /73C
6.
3 (8 x 30mm CSK)
5. 7.
2(M3x6mm)
ENTRIX 1EX5P
EX5/EX5P

1. 2. 3. 4.
EX5:102A/ B / G EX5-P:103A/ B/ G
30m m
Ø6.0
Cable
Cable
5. 6. 7.
3 (8 x 30mm CSK)
4 (M3 x 6mm)
ENTRIX 2
Mounting Montage
UK FR
UK FR
PCB Overview Pr sentation de l’ lectroniqueéé
UK FR
Connecting Strike or EM Lock to relays Connexion d'une gâche aux relais
DC
Power
Supply
_
+
NO
NC
CRelay Terminal
Borniers relais
Electro Magnetic Lock
Ventose
IN4001
External DC Power Supply for EM Lock
Alimentation CC eterne Pour VENTOUSE
AC
Power
Supply
~
NO
NC
C
Strike
Gache
External AC Power Supply for strike
Alimentation CA eterne Pour GACHE
~1k / 1/2W + 470nF
Note: Strike can be connected to DC.
Une gâche peut être connectée à une alimentation DC.
Max. 50m
12/24V AC/DC
Do not apply any
voltage to the
CODIX BUS.
N'appliquer aucune
tension au bus CODIX.
Jumper opened
Cavalier ouvert
Jumper closed
Cavalier fermé
EX5P
Relay Terminal
Borniers relais
EX5P
12V AC/DC
LED G
DG/PS/0009 IS-01
LED R
DG/PS/0009 IS-01
EX5P
Max. 50m

Connecting voltage free LEDs Connexion des Leds libres de tension
12V
+
-
LED +
12V
12V DC (CC) 12V AC (CA)
LED 12V ~
Diode IN4001
+
-
LED
24V DC (CC)
1k / 1/2W
+
-
LED
24V AC (CA) 1k / 1/2W
+
-
24V
UK
-
+
-
+
24V
-24V ~
+
-
ENTRIX 3
FR
Connecting LEDs for relay status Connexion des Leds pour indiquer l’état du relais
UK FR
DC
Power
Supply
_
+
NO
NC
C
IN4001
AC
Power
Supply
~
NO
NC
C
~1k / 1/2W + 470nF
_
+LEDG/LEDR _
+LEDG/LEDR
IN4001
Tamp
(NC)
Tamper switch Switch d'autoprotection
UK FR
Exit button Bouton de sortie
UK FR
PB1
PB2
GND
Exit button (Relay 1)
Bouton sortie 1 actionne le relais 1
Exit Button (Relay 2)
Bouton sortie 2 actionne le relais 2
EX5
External DC Power Supply for EM Lock
Alimentation CC eterne Pour VENTOUSE
External AC Power Supply for strike
Alimentation CA eterne Pour GACHE
Relay Terminal
Borniers relais
Relay Terminal
Borniers relais
Electro Magnetic Lock
Ventose
Strike
Gache
PB2
PB1
GND
Exit button (Relay 2)
Bouton sortie 1 actionne le relais 2
Exit Button (Relay 1)
Bouton sortie 2 actionne le relais 1
EX5P
EX5P

Connecting CODIX peripherals CODIXConnexion des périphériques
UK
ENTRIX 4
FR
EX5
+9V
DATA
CODIX
BUS
GND
+9V
DATA
GND
+9V
DATA
GND
INOX
MINI
VKP
a.
Max. 200m
MINI
EX5/EX5P
Max. 100m
b.
Cable Distance with readers Distance du câble avec les lecteurs
UK FR
EX5P
+9V
DATA
CODIX
BUS
GND
+9V
DATA
GND
INOX
MINI
VKP
+9V
DATA
GND
+9V
DATA
GND
+9V
DATA
GND
Redefining Master code Redéfinition du code Maître
1.
2.
4. 000
3.
5. A
+6. B
Ex: 000 + 2578 + A + B
Ex (nouveau code maître 2578) : 000 + 2578 + A + B
Disconnect power
Débranchez l'alimentation
Reconnect power
Rebranchez l'alimentation
Beep Beep ... + Yellow LED blinks
Bip Bip ... + Led jaune clignote
Yellow LED ON + Long beep
LED jaune ALLUMEE + Long bip
New Master code
Nouveau Code Maitre
Beep Beep
Bip Bip
Yellow LED OFF
LED jaune ETEINTE
UK FR
It is possible to redefine and restore the default setting, if the Master code is forgotten.
Pour changer le code Maître ou en cas de perte de ce dernier, il est possible de le redéfinir suivant les étapes ci-dessous
EX5P
EX5/EX5P
MINI
INOX
LRD G
DG/PS/0009 IS-01
LRD R
DG/PS/0009 IS-01
EX5P

PROGRAMMING FLOW CHART
UK
ENTRIX 5
Master Code
Press 000
Validate By
Press B
1 Small Beep + Yellow Led ON
Programming Mode Yellow LED ON
Change
Master Code
Assign
User Code
Assign
Relay Timing
Assign outputs
To User Code
Delete
All Codes
Delete
Single Code
Normal Mode Yellow LED OFF
Press 0 Press 0 Press
1
Press
2Press 8Press 3 Press 9
Press
00
Memory
location
from (01-99)
Relay
1
Memory
location
from (01-99)
Press 99
Relay
2
Memory
location
from (01-99)
New
Master Code
(1 to 8 digit)
Enter Code
Or
Present card
Or
Present Tag
01-99 Pulse
Mode
'00' ON/OFF
Relay
2
Relay
1
Relay
1&2
Press
2
Press
1
Press
1&2
Validate
A
Multiple small beeps
+
Yellow LED blinks rapidly
Invalid Entry
Multiple small beeps
+
Yellow LED blinks
Two Beeps
Quit Programming Mode
Press B
Next
Programming
Invalid Entry Validation Ok
Memory Position
(01 - 99)
User codes are stored at Memory location (01 to 99).
Master Code is stored at Memory location (00) which is reserved.
User Code Memory locations are assigned to activate Relay 1 & Relay 2.
Redefine Master code
Or
Change Master code
Or
Master code lost
Switch “OFF” Power Supply.
Put Jumper in closed position.
Switch ON Power Supply.
Beep Beep… + Yellow LED “ON”.
Put the Jumper in Open position.
Yellow LED “ON” + Long Beep.
For Default Master Code Press 000 + 000 + A + B
For another Master Code Press 000 + 12345 + A + B
New Master code set to 12345
EX5P

SCHEMA DE PROGRAMMATION
FR
ENTRIX 6
Code maître
Composez 000
Validez par
Composez B
1 bip court + Led jaune allumée
Mode programmation Led jaune allumée
Changer le
code maître
Assigner un
code utilisateur
Configurez la
temporisation
Assigner les relais
au code utilisateur
Effacer un
code utilisateur
Effacer tous les
utilisateurs
Mode normal Led jaune étteinte
Composez 0 Composez 0 Composez
1Composez 8Composez 3 Composez 9
Composez 00
Position de la
mémoire
(de 01 à 99)
Relais
1
Position de la
mémoire
(de 01 à 99)
Composez 99
Relais
2
Position de la
mémoire
(de 01 à 99)
Nouveau
code maître
(1 à 8 digits)
Composez le
code
Ou
Présentez le carte
Ou
Présentez le
badge
Mode impulsionnel
(de 01 à 99)
Mode marche/arrêt
( 00 )
Relais
2
Relais
1
Relais
1&2
Compo-
sez
2
Compo-
sez
1
Compo-
sez
1&2
Validez par
A
Multiples bips courts
+
Led jaune clignote
Fausse manipulation
Multiples bips courts
+
Led jaune clignote
Deux bips
Quitter le mode programmation
Composez B
Prochaine
programmation
Confirmation
réussite
Position mémoire
(01 to 99)
Un code utilisateur est enregistré dans une position mémoire (01 à 99).
Le code mâitre se trouve en position memoire 00.
On peut assigner une position mémoire pour activer relais 1 et/ou relais 2
Redefinition /
Modification
/ ou perte du code maître
Couper l'allimentation
Positionnez le cavalier en position fermé
Connectez l'alimentation
Deux bips + led jaune allumée
Positionnez le cavalier en position ouverte
Led jaune allumée+long bip
Composez le code maître par defaut 000 +000 + a+b
Composez un autre code maître 000 + 12345 + a + b
Nouveau code programmé est 12345
Composez
2
Programming the Keypad Programmation du clavier
UK FR
1.1 Important Note 1.1 Remarque
UK FR
- User Code (1 to 8 digits) are stored in memory locations from 01- 99
- Any user code memory location can activate Relay 1 and / or Relay 2.
- Examples below use the default Master Code '000'
- For security reasons it is recommended to change the default Master
Code as in the following example;
000 + B + 000 + 5894 + A + B.
- In case Master Code is lost or forgotten, refer Redefine the
Master Code section.
- If User wants to replace his code (say, 123) with a Tag, it can be
programmed as shown in the example below:
EX5 : By presenting a tag in front of the proximity reader
wired to the Codix terminal block of the EX5.
EX5P:By presenting a tag in front of the EX5P keypad or
of a proximity reader wired to the Codix terminal block
of the EX5P
- Une position mémoire ( de 01 à 99 ) est l'endroit de la mémoire ou l'on va
mémoriser le code utilisateur ( de 1 à 8 digits )
- Une position mémoire peut actionner le relais 1 et/ou le relais 2
- Les exemples ci-dessous utilisent le code maître par défaut '000
- Pour des raisons de sécurité il est conseillé de changer ce code (ex : 5894)
000 + B + 000 + 5894 + A + B
- En cas de perte du code maître : voir Redéfinition du code maître
- Les exemples ci-dessous utilisent le code utilisateur 123 mais on pourrait
maginer de remplacer ce dernier par un badge.
EX5 : En présentant un badge en face du lecteur de proximité raccordé
aux bornes CODIX de l'EX5.
EX5P: En présentant le badge devant les touches du clavier ou en
raccordant un lecteur de proximité au bus CODIX de l'EX5P.
EX5P
Fausse
manipulation

ENTRIX 7
1.2 Programming 1.2 Aide programmation
UK FR
1.3 Using the code or tag 1.3 Utilisation du code
UK FR
1.2.1 To assign a User code to a Memory position.
Ex: Code 123 to a Memory Position 05
000 + B + 0 + 05 + 123 + A + B
1.2.2 Assigning a memory position to a relay
Ex: Memory location 05 to activate relay 1
000 + B + 3 + 05 + 1 + A + B
Ex: Memory Location 05 to activate relay 2
000 + B + 3 + 05 + 2 + A
Ex: Memory Location 05 to activate both relay 1 and relay 2
000 + B + 3 + 05 + 1 + 2 + A + B
Note: Examples 1.2.1 and 1.2.2 can be combined without leaving
programming mode, e.g. to assign a user code 123 at memory
location 05 and to activate relay 1, the combination can be
programmed as below.
000+B+0+05+123+A+3+05+1+A (for relay 1)+B
1.2.3 Programming for the Relay Status
Relay 1: ON/OFF (Latch) Mode (00)
000 + B + 1+ 00 + A + B
Relay 2: Pulse Mode 05 Seconds
000 + B + 2 + 05 + A + B
1) Users can either
- Press the user code and validate by pressing A (EX : 123 +A )
- Present a Card Or Tag in front of a keyad(EX5P) or a Proximity
reader connected by the CODIX bus.
EX5-P can be programmed as follows
- Code + (Tag Or Card)
- Code Or Tag) + (Code Or Tag)
1.2.1 Assigner un code utilisateur à une position mémoire.
Ex:Code 123 , position mémoire 05
000 + b + 0 + 05 + 123 + A + B
1.2.2 Assigner une position mémoire à un relais.
Ex:Position mémoire 05, relais 1
000 + B + 3 + 05 + 1 + A + B
Ex: Position mémoire 05, relais 2
000 + B + 3 + 05 + 2 + A + B
Ex: Position mémoire 05, relais 1 et relais 2
000 + B + 3 + 05 + 1 + 2 + A + B
Remarque: Le point 1 et 2 peuvent être combinés sans devoir sortir de
programmation (ex : assigner le code 123 à la position
mémoire 05, cette dernière actionne le relais 1)
000 + B + 0 + 05 + 123 + A + 3 + 05 + 1 + A + B
1.2.3 Programmer la temporisation du relais
Relais 1: Mode marche/arrêt ( 00 )
000 + B + 1 + 00 + A + B
Relais 2: Temporisation de 5 secondes ( 03 )
000 + B + 2 + 03 + A + B
1) Les utilisateurs devront soit :
- Introduire le code et valider par A ( ex : 123 A )
- Présenter le badge devant les touches du clavier (EX5P) ou le lecteur de
proximité raccordé au bus CODIX
L'EX5P permet d'assigner à une position mémoire
- Un code + Badge
- Un Badge + Badge
2.0 Double Security (EX5-P only) 2.0 Double sécurité (EX5P)
UK FR
2.1.1 To assign Tag 1 + a User code in a memory location
Ex: Tag + Code 123 in memory location 05
000+B+0+05 + Present Tag 1+ 123 +A+B
2.1.2 To assign Tag 1 + Tag 2 in memory location 05
000+B+0+05 + Present Tag 1+ Present Tag 2 +A+B
2.1.1 Assigner un Badge(1) + code utilisateur à une
position mémoire.
Ex: Code 123 , position mémoire 05
000 + B + 0 + 05 + 123 + présenter le Badge(1) + A + B
2.1.2 Assigner un Badge(1) + Badge(2) à une position mémoire.
(position mémoire 05)
000 + B + 0 + 05 + présenter le Badge(1) + présenter
le Badge(2) + A + B
2.2 Using code and / or tags .2 Utilisation du code2
UK FR
Code + Tag:
- Code + Tag (Press a Code + Validate with A + Present a Tag)
123 + A + Present Tag
- Present a Tag + Press a Code + Validate with A
Present the Tag + 123 +A
Tag +Tag:
- Tag1+Tag 2 (Present Tag 1 and then present Tag 2)
- Tag2 + Tag1 (Present Tag 2 and then present Tag 1)
Tag2 + Tag 1
Les utilisateurs devront soit:
- Code + Badge ( introduire le code + Valider par A + Présenter le Badge )
123 + A + Presenter Badge(1) ou Présenter Badge(1) + 123 + A
- Code + Badge ( introduire le code + Valider par A + Présenter le Badge )
Presenter Badge(1) + Presenter Badge(2) ou
Présenter Badge(2) + Presenter Badge(1)
EX5P
2.1 Programming 2.1 Aide programmation
UK FR

ENTRIX 8
PB1
GND
PB2
NC
C
NO
12/24V
AC/DC
RELAY 1
+
_LG
+
_
+9V
DATA
GND
TAMP
NC
C
NO
LR
RELAY 2
Strike
Gâche
Alarm CKT
Red/Rouge
White/ Blanc
Black/ Noir
Green/ Vert
Blue/ Bleu
Grey/ Gris (NC)
Orange/ Orange (NC)
Reader
MINI
GND
Signal
Quit/
Quitter
Single Door connection diagram/ Schéma de câblage pour une porte
PS2 POWER SUPPLY
IN4001
Yellow/ Jaune (NC)
+
_
GND
DATA
+9V
12V
AC/DC
+
_
LEDR
+
_
TAMP
NC
C
NO
RELAY 1
NC
C
NO
PB2
GND
PB1
LEDG
RELAY 2
Reader
MINI
+
_
Alarm CKT
PS2
POWER SUPPLY
3.0 Application Diagram For EX5 3.0 Diagramme d'application EX5
UK FR
NC: Not Used
Pas Utilise
4.0 Application Diagram For EX5P 4.0 Diagramme d'application EX5P
UK FR
NC: Not Used
Pas Utilise
Single Door connection diagram/ Schéma de câblage pour une porte
XPR/DG/IM/0070 IS-01
Quit/ Quitter
Warranty : XPR warrants its products to be free from defects in material and workmanship for 24 months from the date of shipment. The product is to be installed in
accordance with XPR's instructions and the unit should not be modified or tampered with. XPR does not assume any responsibility for damages arising from misuse of
the product. XPR's sole responsibility is limited to the repair or replacement when the product is sent to XPR's facility.
Garantie : XPR garantit ses produits au regard des défauts matériels et ce pendant 24 mois à compter de la date d'expédition. Le produit doit être installé
conformément aux instructions de XPR et l'unité ne doit pas être modifiée ou manipulée. XPR n'endosse aucune responsabilité pour les dommages résultant d'une
mauvaise utilisation du produit. La responsabilité de XPR se limite à la réparation ou à son remplacement, le produit ayant été retourné à XPR.
EX5P
Red/Rouge
White/ Blanc
Black/ Noir
Strike
Gâche
Green/ Vert
Blue/ Bleu
Grey/ Gris (NC)
Orange/ Orange (NC)
Yellow/ Jaune (NC)
PS2
POWER SUPPLY
PS2
POWER SUPPLY
IN4001
Signal
GND
GND
www.xprsec.com
An ISO 9001:2000
Certified Company
This manual suits for next models
1
Table of contents
Other xpr Lock manuals
Popular Lock manuals by other brands

Kesseböhmer
Kesseböhmer eTouch technical information

Superior Electronics
Superior Electronics Roll and copy instruction manual

Ergotron
Ergotron StyleView 97-702 Assembly instructions

Metro DataVac
Metro DataVac STARSYS WIRELESS Programming guide

Mottura
Mottura X MODE M2.0 manual

Windsor
Windsor 1390 Fitting instructions