Errorcode PossibleReasons troubleshooting
Err1Loadshortcircuit
Aconductivemetalisembeddedinthe
titaniumplates
Cutoffthepowersupply,removethechlorine
generatorandrinsethetitaniumplate
Thereisashortcircuitofwaterinletatthe
connectionoftitaniumplates
Checkwhetherthewiringpositionoftitanium
plateisfloodedorburntout.Ifnotdrainoutof
water,re-installandstarttheequipment
Err2Loadbreak
Verylowsalinity,nocurrentorverylittle
current
Addasmallamountofsaltwatertothecellsand
restartthechlorinegenerator
Thewireconnectingthetitaniumplatefall
off
Cutoffthepowersupply,removethechlorine
generator,andcheckwhetherthetitaniumplate
wiringisoff
Thetitaniumplateisveryold Changeelectrolyticcell
Err3 Salinityishigherthanthemaximumlimit
specified Changepartofthepoolwatertoreducesalinity
Err4 Salinityislowerthanthemaximumlim it
specified
Err5,WaterTemperature
lighton
Thewatertemperaturedetectedis
exceeded11℃˜45℃(51˜113F),willre-work
againwhenthewatertemperatureis
between13℃˜43℃(55˜109F)
-Ensurethewatertemperatureisrecoveredand
restartthechlorinegenerator
-Checkwhethertheflowswitchcircuitisbroken
NOFLOW
Insufficientwaterflow,thecavityisfilled
withair,andtheflowswitchisnotturned
on
-Ensurethefilterpumpisoperatingandthatthere
arenoobstructionsorrestrictionsinthepiping
-Increasetheflowoffilterpump
-Expelairfromthecells,ensuringthatthewater
surfaceexceeds2/3ofthecells
Thefilterisinbackwashstatus Adjustfilteroperationstatus
Disconnectionoftheflowswitchcircuitor
otherfault Replacetheflowswitch
LEDdisplayscreendoes
notdisplay
Displayscreendamaged
-Checkthatthepowercordofthecontrolboxis
pluggedintoaprotectedsocket-makesurethat
thechlorinegeneratorisworkingproperly
-Replacethechlorinegeneratorcontrollerbox
- Add salt to the pool
-Expelairfromthecells,ensuringthatthewater
surfaceexceeds2/3ofthecells
9