manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Xylem
  6. •
  7. Water Pump
  8. •
  9. Xylem FLOJET 3526 Series User manual

Xylem FLOJET 3526 Series User manual

FEATURES
• Self–Priming
• Dry Running
• Soft Noise Absorbing Mounts
• Snap–in Port Fittings
• Built-in Bypass : Less Pulsation
• Reduces need for accumulator tank
• Corrosion Resistant Materials
SPECIFICATIONS
Motor: Permanent Magnet, Ball Bearing
Totally Enclosed. CE Models are
fully suppressed.
Pump: Three chamber diaphragm design
Self-priming up to 9 feet suction lift;
Pump able to run dry without damage Dimensions English (SI)
*CE fully suppressed models are identified by a prefix “R” and a CE mark on the label.(i.e. R3626144).
Self Declaration Of Conformance (SDOC) is available upon request.
OPERATION
With pump switch off and battery fully charged, fill water tank, open all faucets, then turn pump switch on. Water will
begin to flow. When the water is free of air, turn faucets off. Remember, you are filling the water heater and the toilet
and shower lines. When all valves are shut-off, pump will stop. Should pump fail to stop, turn switch off and see the
trouble shooting guide. CAUTION - Pump surface will get hot to the touch if operated for extended periods of time
under pressurized conditions.
2.25"
3.12"
4.24"
4.75"
3.18"
9.04"
(80 mm) (65 mm)
(229 mm)
(80 mm)
(108 mm)
(121 mm)
DIMENSIONAL DRAWING
Model 3426 / 3526 / 3626 Series
Pump Height Length Width Weight
Series inches (mm) inches (mm) inches (mm) Lb (Kg)
3X26XXX 4.75 (121) 9.00 (229) 6.00 (152) 3.50 (1.59)
MODEL* VOLTS AMP DRAW
@10 psi (0.7 bar)
FLOW
GPM (LPM)
PRESSURE SWITCH
Max psi (bar)
BYPASS
03526144 12V dc 4.4 2.9 (11) 50 (3.4) Yes
R3626344 24V dc 2.2 2.9 (11) 40 (2.8) Yes
R3426144 12V dc 4.4 2.9 (11) 25 (1.7) Yes
R3426344 24V dc 2.2 2.9 (11) 25 (1.7) Yes
R3426148 12V dc 3.5 2.0 (8) 25 (1.7) Yes
R3426348 24V dc 1.7 2.0 (8) 25 (1.7) Yes
“TRIPLEX DIAPHRAGM”
3426 / 3526 / 3626 SERIES
AUTOMATIC WATER SYSTEM PUMP
C
A
B
Red (+)
Fuse
(+)
Switch
Battery
Black ( )
-
)
-
)
INSTALLATION WIRING
STE 1
Remove shipping plugs from pump ports. Some water
from factory testing may spill out.
STE 2
Connect fittings supplied with the pump to the RV’s
plumbing. Use 1/2’ I.D. Flexible hose (preferably braided
or reinforced) to reduce vibration through the plumbing
system as shown on Fig. 1. Use hose clamps on the
slip-on barb hose connectors.
STE 3
Slide rubber mounts fully into 4 mounting tracks.
STE 4
Mount pump vertically, with pump head down or
horizontally in an accessible location. If mounting
vertically, motor up, attach motor mounts first then pump
head mounts, while supporting weight of pump.
STE 5
Install inlet A and discharge B port connectors. Firmly
push slide clips C forward to lock port connectors in
place.
STE 6
Install a Flojet strainer in an accessible location (for
inspection and cleaning) between the tank and pump inlet.
This strainer or equivalent is required for pump warranty
to be valid.
STE 1
Use 14 gauge stranded wire to 20’, 12 gauge to 50’,
from power source.
STE 2
Use a 10-15 amp rated on-off switch on the (+) positive
(red) motor lead.
STE 3
Install a 10 amp fuse protection on the positive lead.
FIG. 1
Note: To help reduce noise and vibration of the pump
through the system use flexible lines on the inlet and
outlet of the pump as shown above. Be sure to use
lines rated to not collapse under pump vacuum.
City Water
Inlet
Check
Valve
Flojet Inlet
Strainer
Water
Heater
Water
Tan k
ACCESSORIES
QUICK CONNECT PORT SYSTEM
1
3
4
2
WARNING: BEFORE SERVICING UM , TURN OFF UM AND DRAIN WATER FROM SYSTEM!!
AUTOMATIC WATER SYSTEM PUMP SERVICE PARTS
TROUBLESHOOTING
Failure to rime - Motor operates, but no pump discharge
• Restricted intake or discharge line
• Air leak in intake line
• Debris in pump
• Punctured pump diaphragm (pump leaks)
• Crack in pump housing
Motor falls to turn on
• Loose wiring connection
• Pump circuit has no power
• Blown fuse
• Pressure switch failure
• Defective motor
ulsating Flow
• Restricted pump delivery. Check discharge lines, fittings
and valves for clogging or undersizing
ump Fails to Turn Off After All Fixtures Are Closed
• Empty water tank
• Insufficient voltage to pump (low battery)
• Punctured pump diaphragm (pump leaks)
• Discharge line leak
• Defective pressure switch
Low Flow and ressure
• Air leak at pump intake
• Accumulation of debris inside pump and plumbing
• Worn pump bearing (excessive noise)
• Punctured pump diaphragm (pump leaks)
• Defective motor
E PLODED VIEW
• The above part numbers are packaged with 2 fittings per bag.
STRAINERS ump Series Strainer Number Inlet Outlet Screen
3X26XXX 1740012 1/2 Barb Quad Port 40 Mesh
1740002 1/2 Barb 1/2 Barb 40 Mesh
1740004 1/2 M Qest 1/2 M Qest 40 Mesh
1740014 1/2 M Qest Quad Port 40 Mesh
KEY# DESCRIPTION 3426 3526 3626
1 Pressure Switch 2091025 2091050 2091040
2 Pumphead Assembly 20406047A (2.9 gpm) 20406045A 20406046A
20406048A (2.0 gpm)
3 Check Valve Assembly 20407034 20407034 20407034
4 Slide Clips (Pair) 21000407A 21000407A 21000407A
20381-000
QUAD PORT x
1/2" MALE QEST.
STRAIGHT
20381-002
QUAD PORT x
1/2" HOSE BARB
STRAIGHT
20381-006
QUAD PORT x
3/4" HOSE BARB
STRAIGHT
20381-007
QUAD PORT x
GARDEN HOSE
STRAIGHT
20381-008
QUAD PORT x
1/2" MALE QEST.
90°ELBOW
20381-009
QUAD PORT x
1/2" HOSE BARB
90°ELBOW
20381-010
QUAD PORT x
3/4" HOSE BARB
90°ELBOW
Winterizing Sanitizing
SYSTEM CARE AND MAINTENANCE
Allowing water to freeze in the system may result in
damage to the pump and plumbing system.
Non-Toxic antifreeze for potable water may be used with
Flojet pumps. Follow manufacturers recommendations.
Refer to coach or equipment manufacturers instructions
for their specific winterizing and drainage procedures.
Do not use automotive antifreeze to winterize potable
water systems. These solutions are highly toxic and may
cause serious injury or death if ingested.
1. Drain the water tank. Open tank drain valve and
plumbing drain valves if applicable. You may use the
pump to drain the tank by opening all the faucets in the
system. Allow the pump to operate until the tank is
empty. Do not operate the pump more than 15 minutes
continuously.
2. Open all faucets and flush the toilet to purge all the
water from the pump and the plumbing system. Run
the pump until no water is coming through the faucets.
Turn power to the pump off. Be sure that all the water
from the drain lines are drained.
3. Remove quick connect inlet and outlet fittings from the
pump and turn the pump on to pump out remaining
water from the pump head. Be sure to have a catch pan
or a rag under the pump to prevent water from spilling
on to the RV. Turn the pump off once the plumbing is
empty. Leave the fittings disconnected from the pump
until the system is ready to be used again. Make a note
on your tank filler that the plumbing is not connected.
4. Be sure that all faucets are left open to protect against
damage to the plumbing.
Portable water systems require periodic maintenance to
deliver a consistent flow of fresh water. Depending on
use and the environment the system is subject to,
sanitizing is recommended prior to storing and before
using the water system after a period of storage.
Systems with new components, or ones that have been
subjected to contamination, should also be disinfected
as follows:
NOTE: The sanitizing procedure is in conformance with
the approved procedures of RVIA ANSI A119.2 and the
US Public Health Service.
1. Use of the following methods to determine the amount
of common household bleach needed to sanitize the
tank.
1. A) Multiply “gallons of tank capacity” by 0.13; the
result is the ounces of bleach needed to sanitize
the tank.
1. B) Multiply “Liters of tank capacity” by 1.0; the result
is the milliliters of bleach needed to sanitize the
tank.
2. Mix into solution the proper amount of bleach within a
container of water
3. Pour the solution (water/bleach) into the tank and fill
the tank with potable water.
4. Open ALL faucets (hot and cold) allowing the water to
run until the distinct odor of chlorine is detected.
5. The standard solution must have four (4) hours of
contact time to disinfect completely. Doubling the
solution concentration allows for contact time of one
(1) hour.
6. When the contact time is completed, drain the tank.
Refill with potable water and purge the plumbing of all
sanitizing solution.
WARRANTY
FLOJET warrants this product to be free of defects in material
and/or workmanship for a period of two years after purchase by
the customer from FLOJET. During this two warranty period,
FLOJET will at its option, at no charge to the customer, repair or
replace this product if found defective in material or
workmanship, with a new or reconditioned product, but not to
include costs of removal or installation.
This is only an overview of our Limited Warranty. If you would
like a copy of our warranty, please call or write FLOJET.
RETURN PROCEDURE
Prior to returning any product to FLOJET, call customer service
for an authorization number. This number must be written on the
outside of the shipping package. Place a note inside the
package with an explanation regarding the reason for return as
well as the authorization number. Include your name, address
and phone number.
Jabsco is a trademark of Xylem Inc. or one of its subsidiaries.
© 2014 Xylem, Inc. 81000-384 Rev. G 05/2014
www.flojet.com
U.S.A.
Flojet
17942 Cowan Avenue
Irvine, CA 92614
Phone: 949.608.3900
Fax: 949.608.3887
UNITED KINGDOM
Flojet
Bingley Road, Hoddesdon
Hertfordshire EN11 OBU
Tel: +44 (0) 1992 450145
Fax: +44 (0) 1992 467132
JAPAN
NHK Jabsco Company Ltd.
3-21-10, Shin-Yokohama
Kohoku-Ku, Yokohama, 222
Tel: 045.475.8906
Fax: 045.475.8908
GERMANY
Jabsco GmbH
Oststrasse 28
22840 Norderstedt
Tel: +49-40-53 53 73 -0
Fax: +49-40-53 53 73 -11
ITALY
Jabsco Marine Italia
Via Tommaseo, 6
20059 Vimercate, Milano
Tel: +39 039 685 2323
Fax: +39 039 666 307

This manual suits for next models

3

Other Xylem Water Pump manuals

Xylem JABSCO 42755 Series User manual

Xylem

Xylem JABSCO 42755 Series User manual

Xylem wtw F 800 DIN User manual

Xylem

Xylem wtw F 800 DIN User manual

Xylem GOULDS MCS Manual

Xylem

Xylem GOULDS MCS Manual

Xylem LOWARA ResiBoost MMW Instruction manual

Xylem

Xylem LOWARA ResiBoost MMW Instruction manual

Xylem LOWARA ESH Series User manual

Xylem

Xylem LOWARA ESH Series User manual

Xylem Goulds MPE Series Setup guide

Xylem

Xylem Goulds MPE Series Setup guide

Xylem GOULDS LB User manual

Xylem

Xylem GOULDS LB User manual

Xylem Goulds LB Series User manual

Xylem

Xylem Goulds LB Series User manual

Xylem Jabsco Ballast King 22610-9007 User manual

Xylem

Xylem Jabsco Ballast King 22610-9007 User manual

Xylem Lowara ecocirc S Manual

Xylem

Xylem Lowara ecocirc S Manual

Xylem Flygt Top 50 User manual

Xylem

Xylem Flygt Top 50 User manual

Xylem Goulds NPE Manual

Xylem

Xylem Goulds NPE Manual

Xylem JABSCO 6400 Series User manual

Xylem

Xylem JABSCO 6400 Series User manual

Xylem e-IXP Manual

Xylem

Xylem e-IXP Manual

Xylem GOULDS NPO User manual

Xylem

Xylem GOULDS NPO User manual

Xylem FLOJET BevJet Compact User manual

Xylem

Xylem FLOJET BevJet Compact User manual

Xylem Lowara Scuba Series Original instructions

Xylem

Xylem Lowara Scuba Series Original instructions

Xylem Flojet G55 Series User manual

Xylem

Xylem Flojet G55 Series User manual

Xylem Rule LoPro LP900D User manual

Xylem

Xylem Rule LoPro LP900D User manual

Xylem Lowara Scuba Series User manual

Xylem

Xylem Lowara Scuba Series User manual

Xylem Aquavar IPC User manual

Xylem

Xylem Aquavar IPC User manual

Xylem FLOJET G257 Series User manual

Xylem

Xylem FLOJET G257 Series User manual

Xylem FLOJET M50 User manual

Xylem

Xylem FLOJET M50 User manual

Xylem LOWARA F 1-2 Manual

Xylem

Xylem LOWARA F 1-2 Manual

Popular Water Pump manuals by other brands

Coleman 120V QuickPump How to use and enjoy

Coleman

Coleman 120V QuickPump How to use and enjoy

GORMAN-RUPP PUMPS 60 Series Installation, operation, and maintenance manual with parts list

GORMAN-RUPP PUMPS

GORMAN-RUPP PUMPS 60 Series Installation, operation, and maintenance manual with parts list

Dual Pumps BP 125 operating instructions

Dual Pumps

Dual Pumps BP 125 operating instructions

BUSCH COBRA NC 0630 C Installation and maintenance instructions

BUSCH

BUSCH COBRA NC 0630 C Installation and maintenance instructions

Wilden A2 Original Plastic Series manual

Wilden

Wilden A2 Original Plastic Series manual

Bosch 2 609 390 308 Original instructions

Bosch

Bosch 2 609 390 308 Original instructions

TECNOTER LQMI Series manual

TECNOTER

TECNOTER LQMI Series manual

Grant Aerona 3 HPID6R32 instructions

Grant

Grant Aerona 3 HPID6R32 instructions

SAMES KREMLIN REXSON 4B750 user manual

SAMES KREMLIN

SAMES KREMLIN REXSON 4B750 user manual

SHARKS SH 300W Instruction for operation and maintenance

SHARKS

SHARKS SH 300W Instruction for operation and maintenance

SPERONI ECM/D instruction manual

SPERONI

SPERONI ECM/D instruction manual

Giant P220-3000 Operating instructions/ repair and service manual

Giant

Giant P220-3000 Operating instructions/ repair and service manual

ORDISI AP-92 Series Maintenance and Functioning manual

ORDISI

ORDISI AP-92 Series Maintenance and Functioning manual

Kärcher BP 3 Home manual

Kärcher

Kärcher BP 3 Home manual

Etatron eOne MF Series Operating	instructions and maintenance

Etatron

Etatron eOne MF Series Operating instructions and maintenance

SprayTECH EPX2255 owner's manual

SprayTECH

SprayTECH EPX2255 owner's manual

Barnes 4SCC Series Installation and operation manual

Barnes

Barnes 4SCC Series Installation and operation manual

Subaru PTD 206 Instructions for use

Subaru

Subaru PTD 206 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.