YachtSafe W030 User manual

N 30 32.89’
E 114 18.04’
Version 2018 l VETEL AB linfo@vetel.se lwww.yachtsafe.se lGothenburg l Sweden
YachtSafe Manual
Magnetic contact
W030 Magnetic contact
& external Input

Mount the battery
Release the screws with a cross-headed screwdriver to be
able to open up the product and mount the battery.The
LED lamp is ashing if the battery is OK.
Installation of the magnetic alarm Teknisk specikation
Measurements:
Battery lifetime:
Type of battery:
Battery capacity:
Distance range
(free sight):
Temperature range:
Sealing:
60 x 35 x 20 mm
up to 6 years
CR2477
1000 mAh
approx 150 m
-30 to 70°C
IP54
Additions or adjustments to this manual can be found at
www.yachtsafe.se under the Manuals tab.
VETEL AB / YachtSafe leaves 2 years warranty on G31 and G32
from registration date.

IMAGE 1 IMAGE 2 IMAGE 3 IMAGE 4
Connect the alarm accessory
to the G32 system via the app
for iOS or Android:
IMAGE 1 Select Alarm accessories & Relay
IMAGE 2 Add & congure accessories
IMAGE 3 iOS:New accessory
Android: Choose alarm accessory
IMAGE 4 Choose the accessory to connect.
Enter a name for the accessory and
then press Connect and follow the
instructions.
iOS: After connection of the
accessory, go to the tab Alarm ac-
cessories & Relay, press Update in
the top right. Choose to activate/
Inactivate the alarm accessory
by the button Edit in the top left.
Choose your setttings and press
Save.
Android: After connection of the
Alarm Accessory, go to the tab
Alarm accessories & Relay, press
Update. Choose to activate/inac-
tivate the alarm accessory by the
symbol in the top right (press
Edit). Choose your settings and
press Save.
iOS instructions
Android instructions

15 mm
Verifying the magnetic alarm connection?
When you have activated, the small LED-light on the accessorie should blink
rappidly when the connection is OK. If connection failed it will only turn the LED-
light on once for aprox 1-2 sec. If you do not get any response in the app, try again.
When activation is successfull you are ready to mount the magnet alarm. Please
wait approx 2 minutes before you connect another alarm accessory to the G32
system.
Mounting
The distance between the sensor and the magnetic part shouldn’t exceed 15 mm
in its mounted position. The magnetic part needs to be placed against the side of
the sensor that is marked as the Magnetic Area. The sensor gives an alarm when
the magnetic part leave it’s position to the sensor. The sensor has holes to be able
to mount this part with screws. However, the magnetic part needs to be opened
up to be able to mount it with screws. See the lower picture. Both parts can also be
mounted with the help of tape, glue or burdock. The signal from the sensor part to
the alarm unit will pass through walls and a big variety of materials. However, check
the signal before mounting. After the accessory has been connected to the alarm
you are able to push the button on the circuit card fast. If the LED light on the cir-
cuit board is ashing this means that the distance range is enough. You will receive
an alarm to your phone when it is time to change battery in the sensor.
Connect an external sensor
If you wish to use an external sensor connect it to the terminal block adjacent to
the battery. First remove the circuit board. Then use the marks on the end wall of
the cover showing where the whole should be made and drill a hole, (max 3 mm in
diameter), in the sensor part. If the sensor is going to be placed outdoor or in other
wet environments it’s recommended to seal the hole for the cable with silicon.
When using many external sensors they should be connected in series. External
sensors that are connected should be of the type Normally Closed, NC, or Normally
Open, NO. Select the right kind you are using with the app in you Smartphone.
Table of contents