Preparation Procedure
The network remote control system requires a compatible transceiver (FTDX101MP/FTDX101D as of April
2020), a Windows 8.1 or later PC that has a LAN port and audio function, Internet and a LAN network.
System Requirements
zSupported Transceiver
• FTDX101MP/FTDX101D (as of April 2020)
zPC
• OS : Microsoft®Windows®8.1/10 (32bit / 64bit)
• LAN Port (100BASE-TX/1000BASE-T)
• Audio interfaces (Speaker or Headphone, and Microphone)
zLocal Area Network
zInternet connection (Download speed: at least 2 Mbps , Upload speed: at least 1.2 M bps are recom-
mended at the PC Side)
zEthernet cable
Commercially available straight Ethernet cable (category 5e or higher)
zPC Software
Download the “SCU-LAN10 Remote Software”and “SCU-LAN10 Setting Tool”from our website.
Initial settings for SCU-LAN10 and remote control software are required.
These initial settings are required only once at the rst time.
Check the LAN for installing the transceiver (P.8)
Install the software on a computer (P.10)
Preparation for initial setting (P.13)
Setting the SCU-LAN10 (P.18)
Restore the network settings of the computer (P.25)
Initial setting of FTDX101MP/D (P.28)
Open UDP port of router (P.30)
Remote connection (P.31)

3
Contents
Preparation Procedure............................................................................................2
Introduction..............................................................................................................4
Important ....................................................................................................................... 4
Important Notes ............................................................................................................ 4
Precautions for use ...................................................................................................... 4
Trademarks ................................................................................................................... 4
System Requirements (Operating Environment) ...................................................... 5
Other notes and restrictions ....................................................................................... 6
Packing List .................................................................................................................. 6
SCU-LAN10 ..............................................................................................................7
Front panel ................................................................................................................. 7
Rear panel.................................................................................................................. 7
Check the LAN for installing the transceiver ..................................................8
Install the software on a computer.................................................................10
Install Microsoft .NET Framework 4.X ...................................................................... 10
Install the Network Remote Control Software ......................................................... 11
Preparation for initial setting ..........................................................................13
Connect device ........................................................................................................... 13
Temporarily change the PC network settings.......................................................... 14
Setting the SCU-LAN10....................................................................................18
Other functions of SCU-LAN10 Setting Tool ............................................................ 23
Restore the network settings of the computer..............................................25
Initial setting of FTDX101MP/D .......................................................................28
Settings for transmit audio........................................................................................ 28
CAT Rate setting ...................................................................................................... 28
CAT TIME OUT TIMER setting................................................................................. 28
CAT RTS setting....................................................................................................... 28
VOX SELECT setting ............................................................................................... 28
TOT (Time Out Timer) setting................................................................................... 28
Open UDP port of router..................................................................................30
Open the router setting screen................................................................................. 30
Set the UDP port to open ......................................................................................... 30
Remote connection..........................................................................................31
Install the SCU-LAN10 and FTDX101MP/D............................................................... 31
Initial settings for remote control software.............................................................. 33
About setting items................................................................................................... 34
Initial audio level settings.......................................................................................... 35
Windows volume control .......................................................................................... 35
Volume control of SCU-LAN10 Network Remote Control Software ......................... 39
Start remote control ................................................................................................... 40

4
Introduction
The SCU-LAN10 and the Network Remote Control Software are products for remotely operating compatible
transceivers using the Internet or LAN.
Important
Before downloading this software, please read the “Important Notes” carefully.
Downloading or installing this software will be taken as indicating your agreement with the contents of the
“Important Notes”.
Important Notes
• To remotely control a transceiver using the SCU-LAN10, be sure that you comply with your local regulations.
• All responsibility for the use of this software lies with the customer. Yaesu cannot be held responsible in any
way for any damages or losses which may be incurred by the customer as a result of using this software.
• Copyrights and all other intellectual property rights for the software, as well as the software manual, are the
property of YAESU MUSEN CO., LTD.
• The revision, modication, reverse engineering, and decompiling of this software is prohibited. Redistribu-
tion, transfer, and resale of downloaded les are also prohibited.
• Downloaded les may only be used for personal use.
Precautions for use
• Settings for remote operation require knowledge of PCs and networks as well as transceiver settings. We do
not provide support for the PC settings or network settings.
• For the operation of a PC and peripheral devices, follow the instructions provided in the manuals that come
with the PC and peripheral devices.
• To use SCU-LAN10, you need to open the port of the router and change the settings of the rewall and se-
curity software. Customers are responsible for network security when using this product.
• In communication using a network, changes in audio, operation delay, and changes in voice quality occur,
this cannot be improved in principle.
• Depending on the environment or status of a network, PC, OS, security software, etc., the procedures de-
scribed in this manual may not work as expected.
• As a result of using SCU-LAN10 and software, we will not be liable for incidental damages such as damages
caused by missed communication and call opportunities due to customer's incorrect settings, or malfunc-
tions. Use of this software is at your own risk. Yaesu shall not be liable for any damages caused to you by
using this software.
Trademarks
Microsoft®, Windows®, Windows®8.1, Windows®10 are registered treadmarks in the United States and other coun-
tries.

5
System Requirements (Operating Environment)
zSupported Transceivers
FTDX101MP, FTDX101D (As of April 2020)
zThe latest Transceiver Firmware
Update to the latest software and rmware on the YAESU website (https://www.yaesu.com).
• FTDX101MP/D MAIN: V01-14 or later
DISPLAY: V01-06 or later
IF DSP: V01-05 or later
SDR: V02-03 or later
zPC
• OS
Microsoft®Windows®10(32 bit/64 bit)
Microsoft®Windows®8.1(32 bit/64 bit)
S mode is not supported, application runs in 32bit mode
• CPU
Intel®i5-3470, i7-3770 or higher, or equivalent or higher performance
(CPU clock 3.2GHz, quad core or above)
• RAM (System memory)
4GB or more
• HDD (Hard Disk)
10GB or more free space recommended
• LAN port 100BASE-TX/1000BASE-T
• Audio interfaces
• Speaker or Headphone
• Microphone
• Microsoft .NET Framework 4 or higher is installed (enabled)
When using a USB Audio type microphone or speaker, the performance of the PC including the OS will be aected. There-
fore, the sound may be interrupted, or the remote control may be delayed.
zLAN
zInternet connection (Download speed: at least 2 Mbps, Upload speed: at least 1.2 M bps are recommend-
ed at the PC Side)
Communication is possible with the following 4 ports among UDP (user datagram protocol) ports.
50000 - 50003 (Factory setting)
Address conversion function (NAPT, IP masquerade) is required when using a router.
zIf your router or computer has a rewall function, you need to allow communication to the above ports.
zIf the Internet line is also used for other purposes, audio may be interrupted, or remote control may become unstable.
zFixed global IP address or xed domain name (for remote control using Internet line)
When using the Internet, a xed global IP address or xed domain name is required for the network where
the remote controlled radio is installed.
zEthernet cable
Commercially available straight ethernet cable (category 5e or higher)

6
Other notes and restrictions
In principle, when performing remote operation via a network, delays and data loss are inevitable, and smooth
operation may not be possible as in direct transceiver operation. Specically, the following phenomena may
occur.
• Sound may be interrupted
• Since the transmit / standby timing may be delayed, it is not suitable for communications that require quick
response such as contests and pileups.
• The voice quality of the transmit and receive audio is altered.
• It does not support image communication such as SSTV and digital mode communication such as RTTY
(AFSK), JT65, FT8
• CW mode reception is supported, but remote station operation in CW mode is not possible.
• Transceiver power ON / OFF is not available.
Packing List
• SCU-LAN10 unit
• Connection Cable (13pin DIN plug)
• USB A-B Cable
• Ferrite core 2 pcs
• Cable Tie 2 pcs (For xing ferrite cores)

7
SCU-LAN10
Front panel
POWER indicator
Flashes or lights green when the power is on.
STATUS indicator
In addition to the POWER indicator, various statuses of this unit are displayed.
When main power is supplied to the transceiver, the SCU-LAN10 will start up and enter the standby state.
The STATUS indicator (red) starts blinking ∙∙∙∙∙∙ SCU-LAN10 start up
POWER indicator (green) blinks (after about 12 seconds) ∙∙∙∙∙∙ SCU-LAN10 standby
POWER indicator (green) lights up ∙∙∙∙∙∙ Remote control connected
RESET switch
When the power is ON, press and hold until the STAUS indicator (red) blinks with a thin object (about 5
seconds), and all the settings of this unit will return to the factory default.
Do not push the RESET switch too hard.
Rear panel
AUDIO IN/OUT (3.5Φ stero) jack (Not normally used)*.
This jack is for the output of receive audio and input of (100 mVrms @600Ω).
ACC connector
Connect to the transceiver with the included connection cable (13pin DIN connector).
RS-232C connector*
LAN connector
Use a commercially available straight LAN cable (category 5e or higher) to connect to the LAN.
USB connector
Connect to the transceiver with the included USB cable.
DC-IN*
External power connector. (DC 10.5 V max 800mA)
* For future expansion. It is not used with the FTDX101D/FTDX101MP.

8
Check the LAN for installing the transceiver
As it will be necessary for installation, check the "network environment" of the LAN where the remote control
radio is actually installed by following the steps below:
It is not necessary to connect SCU-LAN10 to the network for this conrmation procedure.
Three connection examples are explained below, refer to the explanation that applies to your installation.
(1)For remote control via Internet
When connecting via the Internet, refer to the diagram and check the four designated items.
WAN
Modem
LAN
Router
SCU-LAN10
PC
Other network device
Internet
Global fixed IP address or
fixed domain name
IP address of the router
IP Address
Subnet mask
Check the following settings by referring to the instruction manual of your router or other network device.
Generally, for setting routers and network devices, use a web browser such as Internet Explorer to access
the IP address of the router or network device and display the setting screen.
Global xed IP address or xed domain name on the WAN side of the router
When performing remote control via the Internet, apply in advance to an Internet service provider to ob-
tain a global xed IP address, or use various DDNS (Dynamic Domain Name System) services to obtain
a xed domain name. When using DDNS, it may be necessary to set the DDNS settings automatically
when the dynamic IP address is changed.
IP address of the router
Example:192.168.0.1, etc
Subnet mask
Example: 255.255.255.0, 255.255.0.0, etc.
IP addresses of other devices (other computers, network cameras, etc.) connected to the same router*
If there is a device with the same IP address as SCU-LAN10 in the same network, it will not operate
normally.
Example: 192.168.0.2, 192.168.0.3, etc
*Sharing the network with other devices may cause remote control or audio delay, so it is recommended
that you do not connect other devices as much as possible.

9
(2)When connecting directly with an Ethernet cable for remote control
If you connect the FTDX101MP/D and the SCU-LAN10 directly with an Ethernet cable without using a
router in the same building, you do not need to check the network environment.
Proceed to “Install the software on a computer” (next page).
SCU-LAN10Remote control PC
LAN
LAN
(3)Remote control within the same LAN using a router
When connecting in the same LAN environment using a router such as in a house, check the following
three items with reference to the gure.
Router
SCU-LAN10
Other network device
IP address
Remote control PC
IP address of the router
Subnet mask
IP address of LAN side of the router
Example:192.168.0.1, etc
Subnet mask
Example: 255.255.255.0, 255.255.0.0, etc
IP addresses of other devices (other computers, network cameras, etc.) connected to the same router*
Example: 192.168.0.2, 192.168.0.3, etc
*Sharing the network with other devices may cause remote control or audio delay, so it is recommended
that you do not connect other devices as much as possible.

10
Install the software on a computer
Install the software on the computer that will be used for initial setup and remote control.
This step is not necessary if you have already installed the software.
Install Microsoft .NET Framework 4.X
Operations on a Windows 10 computer are shown in the procedure below for the purpose of explanation.
Microsoft .NET Framework 4.X is installed in Windows 10 and Windows 8.1 by default. Follow the steps below
to conrm that Microsoft .NET Framework 4.X is enabled.
1. Click [Start].
2. Scroll the Start menu and click the Windows System group.
3. Click [Control Panel].
The “Control Panel” screen appears.
4. Click [Programs], and then click [Programs and Features].
The “Programs and Features” screen appears.
5. Click [Turn Windows features on or o].
“Windows feature” screen appears.
6. Make sure that the check box for “Microsoft .NET Framework 4.X” is a black box or check mark, and then
click the [Cancel] button.
If the check box is blank, click the check box to add a black box or check mark, and then click [OK].
Installation of Microsoft .NET Framework 4.X is completed.
Then proceed to “Install the Network Remote Control Software” (Page 11).

11
Install the Network Remote Control Software
Execute the installer and install the “SCU-LAN10 Network Remote Control Software” and “SCU-LAN10 Setting
Tool” on the PC.
Unzip the zip le (SCU-LAN10_Software_V****.zip) downloaded from YAESU website.
The destination folder will be opened automatically.
1. Double-click [SETUP.exe] in the folder.
The les are automatically extracted and the “YAESU SCU-LAN10 Installer”screen is displayed.
If the “User Account Control”screen is displayed, click the [Yes] button.
2. Click [Next].
If the “Windows Security”screen appears, click the [Install] button.
3. Click [Next].
To change the installation folder, click the [Browse] button and select it.
A conrmation screen for the installation folder appears.

12
4. After conrming, click the [Next] button.
5. If the folder does not exist yet, a conrmation screen will be displayed. To create a new folder, click the
[Yes] button.
“SCU-LAN10 Network remote control software” and “SCU-LAN10 setting software” are installed.
When the installation is complete, “Congratulations!” Will be displayed.
6. Click [Finish].
Installation of “SCU-LAN10 Network Remote Control Software” and “SCU-LAN10 Setting Software” is
completed.
If the computer used for the initial settings of SUC-LAN10 and the computer used for remote control are dierent, install the
required software on both computers using the same procedure.

13
Preparation for initial setting
Connect device
For initial setting, refer to the gure and connect the PC and the SCU-LAN10 directly with a commercially
available straight Ethernet cable.
zIt is recommended to connect the PC and SCU-LAN10 directly with an Ethernet cable as shown in the gure without using
a router for the initial setting.
zInitial settings cannot be made via the Internet, so make initial settings before installing the transceiver and SCU-LAN10.
1. Turn the transceiver OFF.
2. Refer to the gure and connect the SCU-LAN10 directly to your computer with a commercially available
straight Ethernet cable.
3. Connect the SCU-LAN10 and FTDX101MP / D with the included ACC cable and USB cable.
ANT 1 ANT 2
EXT SPKR KEY
ACC TUNER
PTT
METER
GND
LINEAR +13.8V
REM EXT ALC RS-232C
A B
Commercially available straight Ethernet cable
LAN
LAN
ACC
ACC
SCU-LAN10 (Factory default settings)
IP address: 192.168.49.1
User: defaultuser
Password: defaultuser
Network settings of PC used for initial setting (example)
IP address: 192.168.49.10
Subnet mask: 255.255.255.0
Use the cable ties (accessories) to secure the
two ferrite cores (accessories) to the bases of
the plugs on both ends of the ACC cable.

14
Temporarily change the PC network settings
It is necessary to temporarily change the network settings of the PC that is connected to SCU-LAN10 and used
for the initial settings.
When you change the network settings, you may not be able to connect to the Internet or network devices from your com-
puter, so restore the settings at the end of this procedure.
Operations on a Windows 10 computer are shown in the procedure below for the purpose of explanation.
1. Right-click [Start] and click [Network Connections].
2. Click [Change adapter options].

15
3. Double-click the network adapter (LAN card) connected to SCU-LAN10.
The “Ethernet status” screen is displayed.
4. Click [Properties].

16
5. Click [Internet Protocol Version 4 (TCP/IPv4)], and then click [Properties].
“Internet Protocol Version 4 (TCP/IPv4) Properties” screen appears.
Please note that “Internet Protocol Version 6 (TCP/IPv6)” cannot be used.
6. Make a note of all the settings below before making any changes to restore the network settings after
completing the settings.

17
7. Change the settings as follows.
(1) Click [Use the following IP address] to add a black circle.
(2) Set the IP address to “192.168.49.10”.
(3) Set the Subnet mask to “255.255.255.0”.
zLeave the Default gateway eld blank.
zIt is automatically changed to “Use the following DNS server addresses”. No DNS server settings are required.
Leave the blank
Enter “192.168.49.10”
Enter “255.255.255.0”
8. Click [OK].
9. Close unnecessary Windows screens.
The network settings of the PC for initial setting of SCU-LAN10 is completed.

18
Setting the SCU-LAN10
Start the setting software “SCU-LAN10 Setting Tool” and perform the initial setting of SCU-LAN10 from a
personal computer.
The following procedure uses Windows 10 operations as an example.
1. Turn the transceiver ON.
Make sure that only the POWER indicator (green) on the SCU-LAN10 is blinking. (It takes about 12 sec-
onds.)
2. Click the Windows Start button and click the [YAESU SCU-LAN10 Setting Tool] icon in the “Yaesu Mu-
sen” group to start the setting software.
The initial login screen is displayed.
You can also double-click the [YAESU SCU-LAN10 Setting Tool] icon on the desktop to start the setting software.
3. When setting the SCU-LAN10 for the rst time, enter the following and click the [Login] button.
IP Address: 192.168.49.1 (Automatically entered)
User: defaultuser (Automatically entered)
Password: defaultuser (Enter the same “defaultuser” as User)
When logging in for the rst time or later, enter the previously set value.
Enter “defaultuser”
Automatically entered
Automatically entered
• If you log in successfully, the “New Account” screen will be displayed automatically only for the rst
time.
• If “login error!” Is displayed, the password may not have been entered correctly, or the computer's
network settings may be incorrect. Also, check the connection between the PC and the LAN cable of
SCU-LAN10.
• If the settings saved in SCU-LAN10 are lost after the second time, reset SCU-LAN10 and start over from
step 3. If "login error!" Is still displayed, check the communication status by referring to “Conrmation
procedure of network communication with SCU-LAN10 by ping (pin) command” (Page 19).
To reset the SCU-LAN10. Press and hold the [RESET] button on the front panel of the SCU-LAN10 with the thin-tipped
bar for about 5 seconds until only the STATUS indicator (red) blinks. Please note that resetting will restore the SCU-
LAN10 settings to the factory default settings.

19
●Conrmation procedure of network communication with SCU-LAN10 by ping (pin) command
(1) Click Start at the bottom left of the Windows screen.
(2) Scroll the Start menu and click the “Windows System”group.
(3) Click [Command Prompt].
The “Command Prompt” screen is displayed.
(4) Enter “ping 192.168.49.1” (for SCU-LAN10 set at the factory) and press the Enter key.
“Replay from 192.168.49.1:” is displayed, network communication is normal.
If “Replay from 192.168.49.1:” is not displayed, refer to “Preparation for initial setting” (Page
13)and recheck the device connection and network settings of the PC.
4. On the “New Account” screen, set “User” and “Password” for future remote control.
User (Alphabet or number from 4 to 32 alphanumeric characters and some symbols*)
Password (Alphabet or number from 10 to 32 alphanumeric characters and some symbols*)
*:Uppercase and lowercase letters are distinguished.
Be sure to make a note of the set User and Password.
5. Click the [OK] button.
6. When the setting is completed, “Success.” Is displayed. Click the [OK] button.
Then the login screen is displayed.
7. The set User and Password are automatically entered, so click [Login].
A screen for conguring SCU-LAN10 opens.

20
8. Set it according to the network environment of the place where SCU-LAN10 and the transceiver are ac-
tually installed, which was conrmed in “Check the LAN for installing the transceiver” (Page 8)
The following three connection examples are explained, so please refer to the diagram that applies to your
installation.
(1) For remote control via the Internet
WAN
Modem
LAN
Router
SCU-LAN10
PC
Other network device
Internet
Global fixed IP address or
fixed domain name
IP address of the router
IP Address
Subnet mask
Set according to the following network environment conrmed in “Check the LAN for installing the trans-
ceiver” (Page 8). Check the LAN for installing the transceiver.
WAN side global xed IP address or xed domain name
IP address of LAN side of router
Sub-net mask LAN
IP address of another device (PC, network camera, etc.) connected to the same router
Other manuals for SCU-LAN10
1
Table of contents
Other Yaesu Control System manuals
Popular Control System manuals by other brands

CSP Pacific
CSP Pacific SENTRY BARRIER MASH TL-4 Product and installation manual

Pentair
Pentair INTELLICENTER user guide

Siemens
Siemens SIMATIC PC BI45 Technical description

PACH & COMPANY
PACH & COMPANY AeGIS 8000 Series Quick installation guide

Knight
Knight UMP Hospitality instruction manual

Siemens
Siemens SINUMERIK 840D sl Commissioning manual