Memo Installation manual

Contents
Yalp sports- & play equipment
T: 0031 547 289 410
E: info@yalp.nl
This manual contains all information you need
to install this product. Make sure you check all
safety chapters and follow the instructions to
prevent dangerous situations.
If you have any remarks or improvements, please
contact us.
Have fun with the product!
1 Preparation 3
2 Memo isometric view 4
3 Memo posts isometric view 5
4 Foundation 6
5 Cable installation 7
6 Installation: Field preparation 8
7 Electronics: Information 9
8 Installation: Electronics 10
9 Changing heads 12
10 Removing master post head 13
11 Removing Basic post head 18
12 Installing new heads 21
13 Adding knee
entrapment prevention 22
14 Dimensions Memo 23
15 Dimensions Memo posts 24
16 Final remark 25
17 Revisions 26

EN_Installation manual_Memo_v2.9 - 3 -
Preparation start
Use a Torx (T25) scewdriver to open the crate.
For installing Memo it is recommended to:
• work with two persons
• assemble in dry environment
Make sure a power cable for the Memo is ready on
location, with an over length of at least 1,5 meters
(1.6yard). The power supply must be assembled on
a separate group with a 30mA ground fault circuit
interrupter (GFCI), fused on 10A or 16A.
YMvKas ground cable, 2 cores, 2,5mm². max.
diameter; 18mm (0.004in² and ±0.7”)
Tool list
• Security Torx-40 bit (with hole cut-out)
• M8 tap and drill
• Hex key 5
• Anchor bolts
• Digging material for the holes
• Fork spanners 17, 13 and 10
• Cordless drill driver
• Socket head toolset 5 and bit holder
• Saw
1 Preparation
Memo
A3
1:50
22-10-2014
n.t.b.
RB
1.1
Nieuwenkampsmaten
12
7672
DE Goor
www.yalp.nl
tel:
0547-289410
fax:
0547-289411
©Yalp
2014
0
cm
1 2 3 4
5
6 7
8
9
Datum
:
Papier
formaat
Teken
schaal
Door
:
Revisie
:
Productnummer
Productomschrijving
Productprijs
Betonprijs
Tot.prijs
Productprijs+Beton
montage
%
Montage
Tot.prijs
+
montagekosten
1
1
0
0
0
%0
0
0
3900
Memo
0
0
0
%0
0
0
3900
Obstakelvrije
ruimte:
9680
Kunstgras:
8000
840840
1500
De
Memo
dient
altijd
geplaatst
te
worden
op
een
vaste
ondergrond
Transport information*
Crate material
Dimensions package posts (L x B x H)
Package weight posts
Dimensions package grass + misc. (L x B x H)
Package weight grass + miscellaneous
Product information*
Netto weight Memo master post
Netto weight Memo basic post
*Weights and sizes are approximate
Pine wood
1,2 x 0,8 x 1,4 m 3’11.2” x 2’7.5” x 4’7.1”
240 kg 530 lbs
1,25 x 1.05 x 2,40 m 4’1.2” x 3’5.3” x 7’7.1”
290 kg 640 lbs
25 kg 55 lbs
20 kg 44 lbs
Additional
• 6x PVC pipes Ø0,32 x 2,90m
(ر0.13”x3.17yards)
• Loctite 243
• Rapid concrete 700-900 kg (110-142 stones)
• Electricity 230 V at middle post a rea
• NEN-EN 1010 certified electrician
• Mini sim card wit ah 3G connection
! Attention !
Make sure at
least 1,5 m
(1.6yard) of
free space
2is available
around the
Memo posts
for safety
reasons.
80000[26”3’]
9680[31”9’]
1500[4”11’]

EN_Installation manual_Memo_v2.9 - 4 -
2 Memo isometric view

EN_Installation manual_Memo_v2.9 - 5 -
3 Memo posts isometric view
1x Memo master post 6x Memo basic post

EN_Installation manual_Memo_v2.9 - 6 -
4 Foundation
Yalp suggests four standard mounting options. Choose the appropriate foundation method for your
situation. For surfaces other than concrete, such as tiles, please contact our foundation installation team
for specific support. Please request your specific installation drawing at Yalp. This information will come
to you in a separate document.
Product nr. When used? Description
YA3930D
Used outdoor. The anchors are deposited
together with the concrete into the
ground. Please note; it is important to
pour the concrete one week before the
Memo is mounted.
-Deep mount-
7x deep mounting ground
anchors.
Included: PVC tubes to conduct
the cables.
YA3930S1
Cables are milled in the floor.
Option for indoor use only, used in
combination with wet pour.
-Surface mount milling-
7x installation plate and anchors
Included: protective tubes to
conduct wires. Ø40mm with
cord. [1.6”]
YA3930S2
Suitable for indoor use only on
combination with wet poor. Option
for places in with milling in the floor is
impossible.
-Surface mount without milling-
7x installation plates and
anchors.
Included: protective tubes to
conduct wires. Ø40mm with
cord. [1.6”] The cables will be in
a dome on the floor. (Plates are
higher leveled than YA3930S1.)
YA3930S3
For definitive outdoor placing (tiles on
top) or for exhibitions, when there can
not be milled any deeper than 150mm
(1.6yards) into the ground. To be placed
in sand or on flat concrete.
-Spider mount-
7x installation plates and steel
tube mounted together as one
solid construction. The spider
frame is positioned 100-150 mm
underground. [3.9-5.9”]Tiles can
be placed over the construction.
YA3930E
Temporary fixation. No milling or
attachment to floor
-Exhibition-
Ask Yalp for possibilities, several
options available

EN_Installation manual_Memo_v2.9 - 7 -
1. Install the ground cable on location
according to the applicable safety
regulations, in the center of where the
circular Memo playground is going
to be. Make sure the ground cable is
powered on a separate power group,
and has a minimum extra length of 1,5
m (±1.6yards) above the ground.
2. Prepare the surface as described in the
costom made fundation document for your
location. Below an example of a curbstone
fininsh.
! Make sure the power connection is located
exactly in the middle of the circle !
5 Cable installation
230v assembled
on a separate
group, with at
least 1,5 m (1.6
yards) above
ground
Outside diameter curb stones: 8000mm (8.7 yards)
4.4yards
1.09yards

EN_Installation manual_Memo_v2.9 - 8 -
There are several alternatives for installation of the Memo floor. The choice depends on the type of
ground it will be placed on. Every alternative requires different placement, so Yalp profides you with a
costumized fundation sheet for your situation.
6 Installation: Field preparation
!Make sure the cables are connected properly before covering and putting on the surface finsih!
Example of surface finish
Basic post Master post
UTP + powercable
230V powercable

EN_Installation manual_Memo_v2.9 - 9 -
7 Electronics: Information
To ensure electric safety, the power cable is double insulated and the Memo electronic parts operate at
a low voltage (max 15V). All electronic parts are incorporated in the Memo construction and stored wa-
terproof (IP65).
- The Memo needs to be powered by 230V AC and runs on 2A.
- The power cable (ground cable, possibly in protective tube) should be lead through the Memo
construction to the mounting panel with the electronic parts.
- The power cable needs to be connected to the power socket on the mounting panel by a certified
electrician.
- Solely use the supplied cable (Ecomate to power net) be used between the power socket and
the safety transformer
- The power cable needs to be connected to the blue power socket norm 2P + earth
contact box of class IP44. This power supply MUST be assembled on separate group with a
30mA ground fault circuit interrupter (GFCI), fused on 10A or 16A. For example with a
protection box of the type: Merlin Gerin, MG 10A-B 19791 DPNA VIGI 30MA
Power (ground) cable. 230V AC on
seperated group with ground fault
circuit interrupter
Connection gound
cable to power socket

EN_Installation manual_Memo_v2.9 - 10 -
Upper side yin computer
Bottom side yin computer
To antenna’s
Power 15V
To touchscreen
unit
Button
SIM
Ethernet
To power supply
Ground cable 230V
(not included)
Data + power to posts
Post 2
Post 7
Post 3
Post 6
Post 4
Post 5
8 Installation: Electronics
1. Install the basic and master posts.
• Place the basic posts and master post in the right position of the field above the anchor.
(see figure on next page)
• Make sure the master post is positioned correctly, with the button pointing
towards post 5. The sticker on the anchor from the master post gives
instruction and indicates on which side the button must be positioned.
• Take sure the hats of the basic posts are pointing to the middle. Stickers are positioned
on the hats of the posts, which gives instruction and are pointing in the right direction.
• Bolt all the posts to the ground with anchor bolts.
2. Connecting the basic posts.
• Lead the power+data cable through the rubber ring up to
the touchscreen unit and connect them
3. Connecting the master post.
• Connect the mains cable to the socket. This must be done by a NEN 1010 certified electrician.
! Do not yet connect the plug !
• Make sure all cables are connected as shown in the picture.
• Connect the 6 data+power cables from the other posts to the yin computer.
Be careful to connect the cables in the right order. See next page.
socker
Power supply
Yin
computer
socket
Transparent front side
Transparent front side

EN_Installation manual_Memo_v2.9 - 11 -
Post 2
Post 4
Post 7
Post 6
Post 5
Post 3
Post 2Post 7
Post 3Post 6
Post 4Post 5
Front side
Yin computer as
seen from above
(section view)
Bottom side yin computer

EN_Installation manual_Memo_v2.9 - 12 -
In this chapter you will find information about how to change the heads of the Memo.
The chapter starts with changing removing the head of the master post and continues with changing
removing the head of the basic post and ends with insalling the new heads.
Tool list:
• 6x PVC pipes. Diameter 32mm, lenght 2,90m (±1.2”,length 3,17yards)
• cordless powered drill driver
• security torx-40 bit (with hole cut-out)
• hex size 5
• loctite 243
9 Changing heads

EN_Installation manual_Memo_v2.9 - 13 -
Bolt M8 x 20 mm secured
PCS
100-210
Master frontplate
PCS
160-212
1
4
1. Remove the main power from the
product by removing the power plug.
2. Remove the frontplate of the master post
by removing the M8x20 (100-210) bolts
(4x). Then move the front cap in the right
direction as showned below.
10Removing master post head
2
3
1

EN_Installation manual_Memo_v2.9 - 14 -
protection plate
PCS
160-252
Bolt M8 x 20 mm secured
PCS
100-210
12
2x M8x20 (100-210)
3. Remove the protection plate from the frame of
the master post. by removing the two bolts.

EN_Installation manual_Memo_v2.9 - 15 -
socker
Power supply
Yin
computer
Data + powercable 1m
PCS
100-127
1
To antenna’s
Button
Ethernet
To touchscreen
unit
upper side yin computer
4. Disconnect the touchscreen unit from the
yin computer by first twisting and then
pulling out the cable as showed below.
socket

EN_Installation manual_Memo_v2.9 - 16 -
Memo hat
PCS
160-242
EPDM ring
PCS
100-406
11
cap hat
PCS
100-512
Bolt M8 x 20 mm secured
PCS
100-210
3
4
5. Remove the hat from the touchscreen
unit by removing the plastic inserts
with a flat screwdriver and then the
tree M8x20 (100-210) bolts.
G
DETAIL G
SCALE 1 : 5

EN_Installation manual_Memo_v2.9 - 17 -
Hexagon M8x12
PCS
100-233
4
Touchscreen
PCS
160-100
1
A
DETAIL A
SCALE 2 : 5
A
DETAIL A
SCALE 2 : 5
Connector on left side!
Remove the bolts.
6. Remove the touchscreen unit from
the steel frame by removing the
four M8x12 (100-233) bolts.

EN_Installation manual_Memo_v2.9 - 18 -
Speaker cap
PCS
160-011
Bolt M8 x 20 mm secured
PCS
100-210
22
2x Bolt M8x20 mm
(100-210)
1. Remove the main power from the product.
2. Remove the speakercaps by removing
the two M8x20 bolts (100-210).
11 Removing Basic post head

EN_Installation manual_Memo_v2.9 - 19 -
Memo hat
PCS
160-242
EPDM ring
PCS
100-406
11
cap hat
PCS
100-512
Bolt M8 x 20 mm secured
PCS
100-210
3
4
3. Remove the hat from the touchscreen unit
by removing the tree M8x20 (100-210) bolts.

EN_Installation manual_Memo_v2.9 - 20 -
Hexagon M8x12
PCS
100-233
Touchscreen
PCS
160-100
1
4
4. Remove the touchschreen unit from
the steel frame by removing the
four M8x10 (100-233) bolts..
5. Disconnect the cable by first twisting and
then pulling the cable as showed below..
Other manuals for Memo
2
Table of contents