Table 2Digital reference selection
Constant setting Switch
S1 Reference in
ut mode Reference setting
*
Monitor (U1−01)
display unit
o1−03 F3−01
selection
range
o1−03=0 o1−03=1
12 bits With SIGN BCD 3 digits, 1%
16 bits With SIGN BCD 4 digits, 1% −
to +
12 bits With SIGN BCD 3 digits, 0.1%
16 bits With SIGN BCD 4 digits, 0.1% −
.
to +
.
12 bits With SIGN BCD 3 digits, 0.01% −15.99 to +15.99%
16 bits With SIGN BCD 4 digits, 0.01% −110.00 to +110.00%
12 bits With SIGN BCD 3 digits, 1 Hz
0or1
16 bits With SIGN BCD 4 digits, 1 Hz −
to +
z0.01 Hz 0.01%
12 bits With SIGN BCD 3 digits, 0.1 Hz −159.9 to +159.9 Hz
16 bits With SIGN BCD 4 digits, 0.1 Hz −400.0 to +400.0 Hz
12 bits With SIGN BCD 3 digits, 0.01 Hz −15.99 to +15.99 Hz
16 bits With SIGN BCD 4 digits, 0.01 Hz −159.99 to +159.99 Hz
616 bits Without SIGN BCD 5 digits, 0.01 Hz 000.00 to +399.98 Hz
12 bits With SIGN 12−bit binary, 100%/4095 −4095 to +4095
16 bits With SIGN 16−bit binary, 100%/30000 −33000 to +33000
12 bits With SIGN BCD 3 digits, 1 r/min −1599 to +1599 r/min 1 r/min
to
—16 bits With SIGN BCD 4 digits, 1 r/min −15999 to +15999 r/min 1 r/min
40 to
12 bits With SIGN BCD 3 digits,
100%/1st to 4th digit of o1−03 setting −1599 to +1599 5th digit of o1−03
settin
x
(x=0 to 3)
—
16 bits With SIGN BCD 4 digits,
100%/1st to 4th digit of o1−03 setting
−10999 to +10999
(when o1−03=9999)
x=0: unit: 1
x=1: unit: 0.1
x0000
(x=1 to 3) —16 bits With SIGN BCD 4 digits, 100%/10000 −11000 to +11000 x=2: unit: 0.01
x=3: unit: 0.001
*SValue when max. output frequency (E1−04) is 400 Hz and frequency reference upper limit (d2−01) is
110%.
SSetting range upper limit ≦max. output frequency (E1−04) or frequency reference upper limit (d2−01)
Setting range lower limit ≧min. output frequency (E1−09) or frequency reference lower limit (d2−02)
SThe first digit can be set between 0 and 15 at BCD input.
†SSet number of motor poles in o1−03 (setting/display unit of frequency reference/monitor).
SOutput frequency (F) = reference set value (r/min) ×(o1−03 setting) /120
‡ Setting example for o1−03:
When o1−03=12000, reference input at 100% is 2000 and monitor display becomes 200.0.
For setting and selecting constants, refer to the constants list in ‘descriptive
manual for constants’ (Manual No. TOEZ-S616-10.11).