Yolink YS5002-UC Operation manual

Smart Motorized
Valve
SET
Installation & User Guide
YS5002-UC
Revision Dec. 16, 2022

. Welcome!
. Before You Begin
. In the Box
. Required Items
. Get to Know Your Smart Motorized Valve
. Install the App
. Add Your Valve to the App
. Installation
. About Control-D2D
. Using the App & 3rd-Party Services
. Battery Replacement
. Factory Reset
. Firmware Update
. Troubleshooting
. Warnings
. Warranty
. FCC Statement
. Contact Us
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
01
01
03
03
04
05
06
08
10
12
13
14
15
16
17
18
19
21
Contents

01
Or by scanning the QR code:
Welcome!
Before You Begin
Visit our Smart Motorized Valve support page on
our website, for the latest installation guides,
additional resources, information and videos by
visiting:
www.shop.yosmart.com/pages/smart-
motorized-valve-product-support
Thank you for purchasing YoLink products! We
appreciate you trusting YoLink for your smart
home & automation needs. Your 100% satisfac-
tion is our goal. If you experience any problems
with your installation, with our products or if you
have any questions that this manual does not
answer, please contact us right away. See the
Contact Us section for more info.
Thank you!
Eric Vanzo
Customer Experience Manager
A
B

02
Download the most current version of the user
guide by scanning the QR code:
NOTE:
These instructions are not intended to be inclu-
sive of all possible pipe and fitting types, nor are
they intended to be comprehensive instructions
for inexperienced installers. If you are not com-
fortable with an installation like this, please
consult or hire a qualified plumber. Instructions
in this guide are based on a new installation, on
copper pipe, with push-fit threaded adapters.
The Smart Motorized Valve can be installed on
CPVC or PEX pipe using the appropriate male
NPT thread to compression or push-fit copper,
CPVC or PEX adapters. YoLink recommends
SharkBite brand fittings. Visit sharkbite.com or
find additional information on our Smart Motor-
ized Valve Support page.
Local plumbing/building codes may require a
standard non-electric or non-motorized valve for
the main water shut-off - do not replace a
non-electric shut-off valve with this motorized
valve without first consulting with the applicable
code authorities. If installing this valve to shut
off the main water line, we suggest installing this
adjacent to the (non-electric) shut-off valve.
Please use care when working with cutting and
other tools than can cause bodily harm if not
used properly!

03
Model:YS5002-UC
Battery: AA x 2
FCC ID: 2ATM75002
Made in China
Motorized Valve
O
S
PULL UP BEFORE
MANUALLY OPEN/SHUT
SET
Smart Motorized Valve Batteries (Installed)
In the Box
C
Locking Pliers
Pipe Wrench Copper Pipe
Cutting Tool
SandpaperThread Seal Tape
Pipe Fittings
/Adapters
These tools or items may be required:
Required Items
D

04
LED Behaviors
SET
The YoLink Smart Motorized Valve is a motor-
ized valve with an integrated YoLink valve con-
troller. To get to know your new Smart Motorized
Valve, refer to the illustrations below.
Manual Control Knob
Lift, then turn either clockwise to
shut the valve or counterclock-
wise to open the valve
SET Button
Multifunction button
LED Indicator
See “LED Behaviors” below
Valve Position Indicator
Window indicates the current
position of the valve. “O”
indicates open, “S” indicates
shut.
Blinking Red Once,
Then Green Once
Device start-up
Blinking Red And Green
Alternately
Restoring to factory
defaults
Blinking Red Once
Valve closing
Quick Blinking Red
Twice
Valve is closed
Blinking Green Once
Valve opening
Quick Blinking Green
Twice
Valve is open
Slow Blinking Green
Twice
Connecting to hub
Quick Blinking Green
Pairing
Quick Blinking Red
Unpairing
Slow Blinking Green
Updating
Fast Blinking Red Every
30 Seconds
Low battery, replace
batteries soon
Get to Know Your Smart
Motorized Valve
E

05
Open the app and tap Sign up for an account.
You will be required to provide a username and a
password. Follow the instructions, to set up a
new account. Allow notifications, when prompt-
ed.
You will immediately receive a welcome email
information. Please mark the yosmart.com
domain as safe, to ensure you receive important
messages in the future.
Log in to the app using your new username and
password.
The app opens to the Favorite screen. This is
where your favorite devices and scenes will be
shown. You can organize your devices by room,
in the Rooms screen, later.
If you are new to YoLink, please install the app
on your phone or tablet, if you have not already.
Otherwise, please proceed to the next section.
Scan the appropriate QR code below or find the
“YoLink app” on the appropriate app store.
Apple phone/tablet
iOS 9.0 or higher
Android phone/tablet
4.4 or higher
Install the App
F

06
1. Tap Add Device (if shown) or tap the scanner
icon:
Scanner icon
2. Approve access to your phone’s camera, if
requested. A viewfinder will be shown on the
app.
3. Hold the phone over the QR code so that the
code appears in the viewfinder. If successful, the
Add Device screen will be displayed.
Model:YS5002-UC
Battery: AA x 2
FCC ID: 2ATM75002
Made in China
Motorized Valve
O
S
PULL UP BEFORE
MANUALLY OPEN/SHUT
SET
Add Your Valve to the App
G

07
You can change the device name and assign it to
a room later. Tap Bind device.
If successful, the screen will appear as shown.
Tap Done.
4. If the Smart Motorized Valve is not already
on, press the SET button for a moment, until the
LED illuminates briefly.

08
1. Shut-off the water serving the pipe where the
valve is to be installed. Drain the water from the
pipe, by turning on a faucet, or by other method
as required.
2. Depending on the adapter fitting used, mea-
sure the length of pipe that must be cut, and
mark the cut lines on the pipe, as shown below.
3. Cut the water pipe through the mark using a
pipe cutting tool, then remove the cut section of
pipe, as shown below.
SET
4. Sand both ends of cut pipe, removing any
burrs or rough edges. Use care handling the cut
edges, which may be sharp! Wipe off the cut
section of pipe with a clean cloth.
Installation
H

09
6. Wrap each adapter’s threaded end with thread
seal tape, per the tape manufacturer’s instruc-
tions, as shown below.
7. Install the Smart Motorized Valve on the
adapter fittings, ensuring a secure connection at
each fitting, as shown below.
8. At the water valve or point of disconnection,
turn the water on again.
9. Verify there are no leaks and no visible water
at the pipe fittings or on the Smart Motorized
Valve.
SET
5. Install your adapter fittings in the pipe ends,
per the manufacturer instructions.

10
YoLink Control-D2D is our unique device to
device control technology. Using YoLink
Control-D2D, YoLink devices can be controlled
without the Hub or an internet connection. (Use
of YoLink Control-D2D is optional; you can use
the Automation feature in the app OR use YoLink
Control, but YoLink Control-D2D offers the
benefit of operation without the Hub or internet
connection.) One device controls another,
directly. A device that sends out commands is
called the controller. A device that receives the
commands is called the responder. Examples of
a controller are a Water Leak Sensor, while
examples of a responder are a Siren or the Smart
Motorized Valve.
10. Test the Smart Motorized Valve several
times by pressing the SET button and listening
for the smooth closing/opening of the valve, and
by checking the water flow at a faucet. The
water should be completely turned off while the
valve is in the shut position.
11. Test the operation of the valve by controlling
it from the app. From the Rooms or Favorite
screen, locate your Smart Motorized Valve, tap
the image, then tap Close to turn off the water,
and tap Open to turn it on.
About Control-D2D
I

11
Pairing instructions:
1. To configure your Water Leak Sensor* as a
controller, press and hold the SET button for
5-10 seconds, until the LED quickly blinks green,
then release the button.
2. To configure your Smart Motorized Valve as
the responder, ensure the valve is closed (manu-
ally, or by pressing the SET button), then press
and hold the SET button for 5-10 seconds until
the LED quickly blinks green, then release the
button. Upon pairing, the LED will stop blinking.
3. Test your paired devices. Upon the detection
of water at the leak sensor, the valve should
automatically close. Please note: the valve will
not open when water is removed from the leak
sensor. The valve should be closed from the app
or by pressing the SET button on the valve.
4. Repeat for other devices, as needed.
Unpairing instructions:
1. At the leak sensor, press and hold the SET
button for 10-15 seconds, until the LED quickly
blinks green then red, then release the button.
2. At the Smart Motorized Valve, press and hold
the SET button for 10-15 seconds, until the LED
quickly blinks green then red, then release the
button.
3. Upon unpairing, the LED on the leak sensor
and the motorized valve will stop blinking and
turn off.

12
4. Test your devices. The Smart Motorized Valve
should no longer respond to a water leak detec-
tion at the leak sensor.
5. Repeat for other devices, as needed.
* Refer to the sensor’s user guide, as needed.
Instructions for Control-D2D pairing can be
found in each Control-D2D-enabled product’s
user guide.
Please visit our website’s Product Support page
for the YoLink app guide and for product specific
app settings and instructions:
www.yosmart.com/support-and-service
Using the App & 3rd-Party
Services
J

13
2. Replace both batteries, observing the polarity
and orientation of each battery.
3. Replace the battery compartment cover and
tighten the screws.
4. In the app, verify the Smart Motorized Valve is
online and batteries are indicated as good.
IMPORTANT!
The Smart Motorized Valve can be powered by
alkaline or lithium batteries. Do not use
rechargeable batteries.
1. Loosen the two battery cover screws and
remove the battery compartment cover
Battery Replacement
K
Model:YS5002-UC
Battery: AA x 2
FCC ID: 2ATM75002
Made in China
Motorized Valve
O
S
PULL UP BEFORE
MANUALLY OPEN/SHUT
SET
TOP

14
Factory reset will erase device settings and
restore it to factory default settings. Doing a
factory reset will not remove the device from
your account and it will not harm the device, or
lose any data or require you to redo your auto-
mations, etc.
Instructions:
Hold the SET button down for 20-30 seconds,
until the LED blinks red and green alternately.
Then, release the button. (Holding the button
down longer than 30 seconds will abort the
factory reset operation)
Factory reset will be complete when the LED
stops blinking.
PLEASE NOTE: Only deleting a device from the
app will remove it from your account. Factory
reset will not delete the device from the app.
Factory Reset
L

15
Your YoLink products are constantly being im-
proved, with new features added. It is periodical-
ly necessary to make changes to your device's
firmware. For optimal performance of your
system, and to give you access to all available
features for your devices, these firmware up-
dates should be installed when they become
available.
In the Detail screen of each device, at the
bottom, you will see the Firmware section, as
shown in the image below. A firmware update is
available for your device if it says “#### ready
now”
Tap in this area to start the update.
The device will update automatically, indicating
progress by percentage-complete. You may use
your device during the update, as the update is
performed "in the background". The LED will
slowly blink green during the update, and the
update may continue for several minutes beyond
the LED turning off.
Firmware Update
M

16
Symptom:
1. Device is offline
- If valve is not connected to the cloud, press
the SET button on Smart Motorized Valve
- If Hub is offline, reconnect the Hub to the
Internet and press the SET button on Smart
Motorized Valve
- If Hub is not on, power on the Hub again and
press the SET button on Smart Motorized
Valve
- If valve is out of range with Hub, relocating
the Hub may be required
- For a device with low-battery indicators or
alerts or if the condition of the batteries is in
question, replace the batteries with two new
"AA" batteries
2. Other issues, contact customer service,
831-292-4831 (M-F 9am - 5pm PST) or email
Troubleshooting
N

17
Please install, operate and maintain the
Smart Motorized Valve only as outlined in
this manual. Improper use may damage the
unit and/or void the warranty
Do not install or use the Smart Motorized
Valve outside of the temperature and hu-
midity range listed in the Environmental
section in Specifications, on the Smart Mo-
torized Valve Support page
While the Smart Motorized Valve is rain-
proof, to ensure optimal operation and life-
time of the Smart Motorized Valve, installing
the Smart Motorized Valve with overhead
protection from weather is suggested. Do
not immerse the Smart Motorized Valve or
allow it to be immersed in water
Do not install or use the Smart Motorized
Valve where it will be subjected to high tem-
peratures and/or open flame
If your Smart Motorized Valve does get dirty,
please clean it by wiping it down with a
clean, dry cloth. Do not use strong chemi-
cals or detergents, which may discolor or
damage the exterior and/or damage the
electronics, voiding the warranty
Do not install or use the Smart Motorized
Valve where it will be subjected to physical
impacts and/or strong vibration.Physical
damage is not covered by the warranty
Warnings
O

18
For warranty information, please visit our Smart
Motorized Valve Support page.
Power the Smart Motorized Valve only with
two AA batteries (see below, regarding bat-
teries)
Use only new, alkaline or lithium non-
rechargeable AA batteries.
Do not use zinc blend batteries
Do not mix new and old batteries
Do not puncture or damage batteries. Leak-
age can cause harm on skin contact, and is
toxic if ingested
Do not dispose of batteries in fire as they
may explode! Please follow local battery
disposal procedures
To avoid damaging the Smart Motorized
Valve, if storing the controller for an extend-
ed period, remove the batteries
Please contact Customer Service before
attempting to repair, disassemble or modify
the device, any of which can void the war-
ranty and permanently damage the device
Warranty
P
Table of contents
Other Yolink Control Unit manuals
Popular Control Unit manuals by other brands

Cisco
Cisco SCE8000 GBE installation guide

Keysight Technologies
Keysight Technologies M937 A Series Startup guide

Nil-Cor
Nil-Cor 300 Series Installation maintenance and operating instructions

Risco
Risco Pro-24 Installation and programming manual

Stober
Stober CAN 5000 Commissioning instructions

Infinite
Infinite L-COM SRAQ-G014 user guide

WNC
WNC DFCN267 user manual

Rockwell Automation
Rockwell Automation Allen-Bradley 1746-HSCE user manual

Spectrum Controls
Spectrum Controls 1794sc-IRT8I user manual

CIRCUIT DESIGN
CIRCUIT DESIGN CDP-TX-02F-R Operation guide

ENFORCER
ENFORCER SD-7202GC-PEQ installation manual

Woodward
Woodward 26283 product manual