ZANO GRID 1-10V
The Zano Grid 1-10V modules have been designed and tested
to work with a range of high frequency 1-10V electronic ballasts
and LED drivers. A maximum of 70 ballasts or 16 LED 1-10 v drivers
can be controlled from a single device. Please use a ballast
manufacturer from the list below. Some digital 1-10 v ballasts
require a DSI Interface.
RECOMMENDED MANUFACTURERS
Aurora......................... Tridonic................... Helvar.................... Huco
Magnetek .................. Osram..................... Philips HFR ............. Atlas
Collingwood .............. Megaman ............. Vossloh Schwabe .........
If you require any assistance with product selection or you have
a particular ballast type to control, please contact our technical
helpline on 0845 519 5858
This product should be disposed of properly and recycled at the
end of its life where facilities exist.
GUIDANCE NOTES
Due to the large inrush current from switch on, care has to be taken
to ensure the installation is carefully designed to accommodate such
load characteristics. For example: Tridonic have listed out in table
form a recommended number of ballasts per circuit. For example,
10A MCB could have a maximum of 10, PCA 1/58 EXCEL. To see
the full list go to www.tridonicatco.com. Other manufacturers also
publish the relevant data to assist in the design of an installation.
The Zano Grid 1-10V has a switched contact between terminals
(AC) and (AC). This contact has a maximum load of 4A resistive.
We would recommend using this contact to control a contactor to
switch the load therefore avoiding contact damage from the inrush
current as shown in diagram.
The DC + & - connections should be made using a screened cable
where the screen is linked and connected to ground at one end.
Due to the variation in manufacture of uorescent tubes, we would
recommend leaving the lamps at full brightness for 100 hours
minimum, for example, 10 hours a day for 10 days. Some makes of
tube may require longer. This will help reduce the icker at low levels
of dimming. This does not apply to 1-10v LED drivers
?
?
1. Remove knob ,unscrew ring
with tool and slide o adaptor.
4. Clip into grid,
replace knob.
3. Use tool to secure
correct adaptor with ring.
2. Choose appropriate
adaptor to t your grid.
a b c d e f g h
DE GE BG WW MK HA MEM CR
ASSEMBLY DIAGRAMS
WE RECOMMEND THAT THE INSTALLATION OF THESE PRODUCTS
SHOULD ONLY BE CARRIED OUT BY A QUALIFIED ELECTRICIAN.
This product should be disposed of properly and recycled at the
end of its life where facilities exist.
a. DETA b. GET c. BG d. Wandsworth
e. MK Logic f. Hamilton g. MEM h. Crabtree
• TURN OFF MAINS at distribution board.
• Wire device using suitably rated cable as in wiring diagrams.
• Terminals should be tightened to a maximum of .33Nm.
• Check polarity is correct throughout.
• Fit appropriate adaptor as in assembly diagrams (If applicable)
• Fit device into wall box ensuring cables are not obstructed.
• Secure front plate.
WIRING INSTRUCTIONS
WE RECOMMEND THAT INSTALLATION OF THESE PRODUCTS SHOULD
ONLY BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
FOR LOW VOLTAGE CONTROL USE A 0.75mm2TWO CORE SCREENED CABLE, EARTH AT ONE END
DC AC AC DC C L1 DC DC L N
GRID
1-10V
ROCKER
SWITCH
HF
1-10V
ELECTRONIC
BALLAST
LAMP
N
L
LAMP
C L1 L2 C L1 L2
GRID
1-10V
ROCKER
SWITCH
ROCKER
SWITCH
HF
1-10V
ELECTRONIC
BALLAST
N
L
DC DC L NDC AC AC DC
L LSW
Zano Controls
Zano Controls produces a range of dimmer switches and lighting
control systems. For our full range of products see our website
www.zanocontrols.co.uk or pick up a copy of our brochure from
one of our stockists.
Contact us at Zano Controls,
Unit 1 Chantry Court,
Wrythe Lane,
Carshalton,
Surrey,
SM5 2DG
Tel: 0845 519 5858
Fax: 0845 519 5757
email: [email protected]
Guarantee
1. The Company guarantees at its entire discretion either to
replace or repair any of the Goods which within the Guarantee
period of the Goods are shown to its satisfaction to be defective
through faulty material or workmanship alone, provided that
no attempt has been made by the Customer or a third party to
rectify, dismantle or alter the Goods in any way.
2. The Guarantee period for any Goods is as specied at the time
in the Company’s catalogue current at the time of acceptance of
the Customer order and commences on the delivery of the Goods.
3. All terms, conditions , warranties, or representations, whether
expressed or implied, as to description, condition, quality or tness
for purpose of any of the Goods are hereby excluded.
4. So far as permitted by statue, the Company shall not be liable
for loss or damage whether direct or consequential and whether
suered by or occasioned to the Customer, it’s employees or
agents or to any third party. Our full terms and conditions can be
found on our website www.zanocontrols.co.uk. IZGRID1-10V/05-12

Popular Control Unit manuals by other brands

QEI 6PTM2 Series user guide

QEI

QEI 6PTM2 Series user guide

KSB ECOLINE GTF Series operating manual

KSB

KSB ECOLINE GTF Series operating manual

DMP Electronics 893A installation guide

DMP Electronics

DMP Electronics 893A installation guide

Raytheon Electronics ST6000 Plus Owner's handbook

Raytheon Electronics

Raytheon Electronics ST6000 Plus Owner's handbook

RTI RCM-4 Quick reference guide

RTI

RTI RCM-4 Quick reference guide

Mitsubishi Electric MELSEC iQ-R Series user manual

Mitsubishi Electric

Mitsubishi Electric MELSEC iQ-R Series user manual

Samsung WEC8500 Operation manual

Samsung

Samsung WEC8500 Operation manual

Anden A76 owner's manual

Anden

Anden A76 owner's manual

LiteOn WCBN3510A user manual

LiteOn

LiteOn WCBN3510A user manual

TCi EZ-TCU manual

TCi

TCi EZ-TCU manual

GE Ziton ZP3-ECU Maintenance manual

GE

GE Ziton ZP3-ECU Maintenance manual

Bailey Infi 90 IMDSO01 Instruction

Bailey

Bailey Infi 90 IMDSO01 Instruction

Epson RX8804CE Applications manual

Epson

Epson RX8804CE Applications manual

axing SKM 1-04 Operation instructions

axing

axing SKM 1-04 Operation instructions

Hydac FCU 1310 Operating and maintenance instructions

Hydac

Hydac FCU 1310 Operating and maintenance instructions

KLINGER INTEC K210-FS Assembly and Repair Instructions

KLINGER

KLINGER INTEC K210-FS Assembly and Repair Instructions

Campbell TEMP 120 product manual

Campbell

Campbell TEMP 120 product manual

HKC LCU-P Installation, operation & maintenance manual

HKC

HKC LCU-P Installation, operation & maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.