Zenith HydroTap G5 Instruction Manual

Quick Start Installation Guide
807120NZ v1.00 01.21 G5 C CS Quick Start Guide
1
Quick Start Installation Guide
Command Centre
Chilled, Chilled/Sparkling models
AFFIX PRODUCT LABEL HERE
Zenith
HydroTap G5
Visit our website to
download the manuals

2Quick Start Installation Guide
807120NZ v1.00 01.21 G5 C CS Quick Start Guide
Table of contents
SECTION 1: Using the instructions......................................................................3
SECTION 2: IMPORTANT SAFETY INSTRUCTIONS............................................. 4
SECTION 3: WARNINGS AND REGULATORY INFORMATION ............................ 6
SECTION 4: Technical data ............................................................................... 8
SECTION 5: Supplied parts checklist ................................................................. 9
SECTION 6: Set up the ventilation....................................................................10
SECTION 7: Fit the carbonation valve............................................................... 13
SECTION 8: Connect the water supply ............................................................ 14
SECTION 9: Install the CO cylinder and regulator........................................... 14
SECTION 10: Connect the Command Centre.................................................. 20
SECTION 11: Commissioning.............................................................................25
Contact details .................................................................................................28
Read the
instructions

Quick Start Installation Guide
807120NZ v1.00 01.21 G5 C CS Quick Start Guide
3
SECTION 1: Using these instructions
This document is a Quick Start Installation Guide.
For further details on installing and operating your HydroTap
download & read the Command Centre installation and user
instructions , which can be found online at:
zenithwater.co.nz
!
Read and use the instructions supplied with individual kit
components for a safe installation.
Before you start
!
!
Explanation of symbols
Read the
instructions
WARNING
!
!
Danger
electric
shock
!UV
!
Highly
Flammable
COGas
WARNING

4Quick Start Installation Guide
807120NZ v1.00 01.21 G5 C CS Quick Start Guide
SECTION 2: IMPORTANT SAFETY INSTRUCTIONS
Safety
This appliance is not intended for use by children under 8 years or persons
(including children under 8 years) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning the use of the appliance by
a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
Refrigerant
The Zenith HydroTap Command Centre range uses either
HIGHLY FLAMMABLE R290, R600a or R134A refrigerant under
pressure.
Check the rating plate or contact Zenith before starting work.
Maintenance of the refrigeration unit must be carried out by an accredited
service provider or qualified refrigeration technician.
Keep ventilation openings, in the appliance enclosure or in the built-in
structure, clear of obstruction.
Do not use mechanical devices or other means to accelerate the defrosting
process, other than those recommended by the manufacturer.
Do not store explosive substances such as aerosol cans with a
flammable propellant in this appliance.
CO2
• Keep out of reach of children.
• Use according to MSDS (Material Safety Data Sheet).
• Pressurised container. Contains gas under pressure,may explode if
heated.
• Protect from sunlight.
!
!
Compliance
In NZ/Australia electrical installation must comply with AS/
NZS3000.
In NZ/Australia plumbing installation must comply with AS/NZS3500.
In NZ/Australia For residential chilled models, all refrigeration must comply
with AS/NZS 60335.2.24.
In the UK the system must be installed in accordance with water supply
byelaws, current IEE regulations and local authority byelaws.
!UV
!

Quick Start Installation Guide
807120NZ v1.00 01.21 G5 C CS Quick Start Guide
5
SECTION 2: IMPORTANT SAFETY INSTRUCTIONS
• Do not expose to temperatures exceeding 50˚C.
• Do not expose to naked flame or any incandescent material.
• Do not pierce or burn, even after use. Avoid shock.
• High concentration of gas may cause asphyxiation.
• Use only in an upright position.
• The cylinder must be used with the supplied pressure regulator.
• The gas cylinder must be installed in an open plan area, or in an
enclosed room with a volume no less than 20m³ per 1200g cylinder, or
50m³ per 2640g cylinder.
• If more than 1 gas cylinder containing COis present within the same
location, the recommended ventilated area should be in proportion to
the number of gas cylinders stored in that location. A ventilated area is a
non-enclosed area which could include the kitchen, living room etc.
• Refer to the gas cylinder and MSDS sheet for a complete list of warnings
downloadable from: zenithwater.co.nz.
Qualifications
To avoid hazards, all installation procedures must be carried out by a
suitably qualified tradesperson. The power cable and power outlet must be
in a safe visible position for connection.
Lifting
Take care when lifting. The Command Centre may exceed safe lifting
limits. If you feel this is beyond your personal capabilities, please seek
assistance with the lift. The weight of the Command Centre is marked on
the packaging. Do not lift the Command Centre by the front cover or any of
its connections.
Airflow
The Zenith HydroTap G5 operates within the ambient temperature range
5ºC - 35ºC. Proper air circulation must be provided. The system will operate
satisfactorily only if the recommended air gaps are provided. The vent kit
supplied must be fitted.
Frost protection
If the HydroTap G5 is located where the ambient air temperature could
fall below 5ºC when the system is not in use, do not turn off the Command
Centre electrically.

6Quick Start Installation Guide
807120NZ v1.00 01.21 G5 C CS Quick Start Guide
!
trained and suitably qualified tradespeople. Faulty operation due
to unqualified persons working on this product, may void warranty
coverage.
• As the installer, it is your responsibility to supply (if necessary) and
install all valves as required by local regulations and relevant standards.
• The HydroTap is rated for 220-240V 50Hz AC operation.
• Do not remove the cover of the appliance under any circumstances
without first isolating the appliance from the power supply.
• Connect only to a potable (wholesome cat1) mains water supply.
• Never locate the system near, or clean with water jets.
• Do not expose the Zenith HydroTap to the elements of nature.
• Use of tools can be hazardous. Assess the risks before you start.
• A pressure limiting valve must be fitted for mains water pressures above
the maximum limits stated.
• A clearance envelope around all Command Centres must be provided to
allow adequate ventilation for the safe and effective use of the HydroTap
system.
• The vent tray, if provided, must be fitted. It provides a safe exhaust for
refrigerant gas in the unlikely event of a leak.
• Valves and fittings must be sealed appropriately with PTFE tape.
• Always flush new filter before use.
!
SECTION 3: WARNINGS & REGULATORY INFORMATION
• The Zenith HydroTap must be earthed, earthing
is provided via the supplied power cord. The resistance of
the earth connection to each exposed metal part must be
less than 1.
Use the power cable supplied. It is the responsibility of the
installer to ensure the power point is earthed.
• All installation and service work must be completed by

Quick Start Installation Guide
807120NZ v1.00 01.21 G5 C CS Quick Start Guide
7
SECTION 3: WARNINGS & REGULATORY INFORMATION
• Do not over tighten plumbing and hose connections.
• Braided hoses supplied cannot be lengthened.
• Be aware of the risks of hazards which could cause harm when handling
compressed CO. Assess the risks before starting the installation.
• Do not proceed with a COcylinder change if the seals are damaged.
Take care not to cross thread the regulator, a cross threaded regulator
poses a potential hazard.
• Care must be taken when working with high pressure carbon dioxide,
and in no case should the normal operating pressure of 3.0 bar be
exceeded.
• The power cord and general power outlet must be in a safe and
accessible position after installation. When positioning the appliance,
ensure the power supply cord is not trapped or damaged. If the power
supply cord is damaged it must be replaced by a Zenith service provider
or a qualified electrician.
• Do not locate multiple portable socket-outlets or portable power
supplies at the rear of the appliance.
• For safe operation, the HydroTap is designed to be installed,
commissioned and used within 48 hours. Should the HydroTap not be
required for an extended period of time (72 hours or more), do not fill
and commission the HydroTap until ready for first use.
• For water taste and quality reasons, following any non-use period of
more than 72 hours, Zenith recommends to perform a system flush.
Failure to flush the system may affect water quality.

8Quick Start Installation Guide
807120NZ v1.00 01.21 G5 C CS Quick Start Guide
SECTION 4: Technical data
Water supply pressure requirements
Technical data
Model Power rating
kW
Dimensions
W x D x H (mm)
Weight
(kg)
CS100 0.37 330 (500)#x 477 x 333 36.5
C100 0.34 330 (500)#x 470 x 333 24.2
C40 0.16 330 x 470 x 333 24.2
CS Home 0.18 280 x 406 x 333 30
C Home 0.17 280 x 406 x 333 21
A pressure limiting valve must be fitted for mains water pressures
above the maximum limits stated above in accordance with local
plumbing regulations. Note: All models (excluding UK) have an
internal pressure limiting device to reduce the maximum mains regulated
pressure (700kPa in NZ/Australia), protecting the system against pressure
surges above 500kPa.
!
# including vent tray
Water supply connection
1/2” BSP (G1/2).
Component Min - Max pressure, kPA (bar)
NZ/Australia
HydroTap 170 (1.7) - 700 (7.0)
Sparkling HydroTap 250 (2.5 ) - 700 (7.0)
Electricity supply requirements
220-240V 50Hz AC (for power requirement see table above).
Required
1x 220 - 240V AC 10A socket

Quick Start Installation Guide
807120NZ v1.00 01.21 G5 C CS Quick Start Guide
9
SECTION 5: Parts supplied
* supplied with 1.2kg cylinder / adjustable regulator combination.
Parts supplied with the HydroTap Chilled Chilled &
Sparkling
Tap
HydroTap tap
HydroTap pipes, tubes hoses and fittings
Separate Mains mixer Tap Optional Optional
Separate Mains mixer Tap fittings Optional Optional
Separate Mains mixer Tap instructions Optional Optional
Command Centre
Command Centre
Mains electrical supply cable
Water supply inlet hose
Water supply inlet adaptor and strainer
Ventilation kit (inc. vent tray for C100, CS100)
Vent kit instructions
Water block kit (UK only) (UK only)
CO
CO cylinder
CO regulator
CO regulator adaptor*
CO hose & instructions
Filters
Water filter & instructions
Font
Font kit Optional Optional
Note: Mains water isolation valve is not supplied with the kit.
Contact Zenith for the full range of consumables and accessories.

10 Quick Start Installation Guide
807120NZ v1.00 01.21 G5 C CS Quick Start Guide
SECTION 6: Set up the ventilation
Command Centre width
!
A clearance envelope around all Command Centres must be
provided to allow ventilation for the safe and effective use of the
HydroTap system.
200mm
50mm 50mm
Use instructions supplied with individual kit parts.
Use of tools can be hazardous. Assess the risks before you start.
!
Other manuals for HydroTap G5
6
Table of contents
Other Zenith Controllers manuals
Popular Controllers manuals by other brands

Digiplex
Digiplex DGP-848 Programming guide

YASKAWA
YASKAWA SGM series user manual

Sinope
Sinope Calypso RM3500ZB installation guide

Isimet
Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

LSIS
LSIS sv-ip5a user manual

Rockwell Automation
Rockwell Automation 1769-L31 installation instructions