INTRODUCTION
Thank you for purchase of the IR 66B Thermometer. This device is a non-contact SPECIFICATION
(infrared) thermometer. Simply aim the thermometer at the target and press the
measurement button to display the surface temperature. The distance to target ratio
is 1:1 therefore the thermometer should be positioned as close to the target as possible.
FEATURES
Rapid detection function
Precise non-contact temperature measurement
Unique flat surface, modern housing design
Automatic Data Hold
Automatic Power Off
℃/℉mode
MAX,MIN ,LOCK modes
Automatic range selection
Resolution 0.1ºC(0.1ºF)
WIDE RANGE APPLICATION
Food preparation, Safety inspectors, Plastic molding, Asphalt, Marine and Screen
printing, measure ink and Dryer temperature, HVAC/R, Diesel and Fleet maintenance.
℃or ℉Mode FRONT PANEL DESCRIPTION
To change the IR66B from ‘ºC’ to ‘ºF’ or from ‘ºF’ to ‘ºC’, firstly turn the instrument on by IR sensor
pressing the measurement button, then press the mode button four times, the ‘ºC’ or ‘ºF’ LCD Display
symbol will flash, press the measurement key to change to scale, then press the Measurement button
measurement button to confirm the mode.
mode button
MINIMUM or MAXIMUM Mode Battery Cover
To utilize the IR66B Min(minimum) or Max(maximum) mode, firstly turn theinstrument on
by pressing the measurement button, then press the mode button once for MAX or twice BATTERY REPLACEMENT
for MIN function. The ‘MIN’or ‘MAX’icon will flash, then press the measurement button As battery power is not sufficient, LCD will display “ ” replacement with CR2032.
to confirm the Min or Max mode. The IR66B will display the Min or Max reading only. The battery is located under the twist cover at the rear of the IR66B. Open battery cover,
then take out the battery from instrument and replace with a new CR2032 battery and
LOCK MODE place the battery cover back.
The lock mode is particularly useful for continuous monitoring of temperatures . Please note:It is important to turn the instrument off before replacing the battery
to utilize the IR66B’s LOCK mode. firstly turn the instrument on by pressing the otherwise the IR66B may malfunction.
Measurement button, then press the mode button three times for the LOCK mode
Range
-35 to +250ºC
Resolution
0.1ºC or ºF
Response Time
Less than 300ms
Infrared Accuracy
-10℃~250℃(14℉~482℉)±2% or ±2℃(3.6
℉)
-35 ~ -10℃(-31℉~ 14℉) ±4℃(7.2℉)
Storage temp
–10 to 60℃(14 to 140℉)
Operating temp
0 to 50℃(32 to 122℉)
Relative humidity
10%~90%RH operating, <80%RH storage>
Field of View
1:1 optics ratio
Battery life
40 hours continuous use (power off after 15
seconds)
Battery
CR2032
“ CE ” Comply with EMC
function. The LOCK icon will flash, then press the measurement button to confirm Note: Avoid keeping the thermometer too close for long periods to objects that
the LOCK measurement mode. The IR66B will continuously display the temperature. continuously generate high (like a hot plate), which can cause overheating of the
Thermometer.
MAINTENANCE & CLEARING
The sensor lens is the most delicate part of the IR66B . The lens should be kept clean at all
times, care should be taken when cleaning the lens using only a soft cloth or cotton swab
with water or medical alcohol, Don’t use abrasives or solvents on this instrument. Allowing
the lens to fully dry before using the IR66B, Don’t submerge any part of the IR66B .The IR66B
should be stored at room temperature.
When serving, use only specified replacement parts.
www.zicotech.com

Other Zico Thermometer manuals

Zico ZI-9678 User manual

Zico

Zico ZI-9678 User manual

Zico ZI-9698 User manual

Zico

Zico ZI-9698 User manual

Zico ZI-7840 User manual

Zico

Zico ZI-7840 User manual

Zico ZI-9615 User manual

Zico

Zico ZI-9615 User manual

Zico ZI-9613 User manual

Zico

Zico ZI-9613 User manual

Zico ZI-9679 User manual

Zico

Zico ZI-9679 User manual

Popular Thermometer manuals by other brands

Thermomedics Caregiver PRO TF-300 Instructions for use

Thermomedics

Thermomedics Caregiver PRO TF-300 Instructions for use

Oregon Scientific RMR132 user manual

Oregon Scientific

Oregon Scientific RMR132 user manual

Amprobe IR-450 user manual

Amprobe

Amprobe IR-450 user manual

Testboy TV 323 operating instructions

Testboy

Testboy TV 323 operating instructions

Extech Instruments IR100 user manual

Extech Instruments

Extech Instruments IR100 user manual

Faithfull FAIDETIRTHER instructions

Faithfull

Faithfull FAIDETIRTHER instructions

Auriol 270302 Operation and safety notes

Auriol

Auriol 270302 Operation and safety notes

RayTek Raynger MX4 manual

RayTek

RayTek Raynger MX4 manual

VOLTCRAFT 2399953 operating instructions

VOLTCRAFT

VOLTCRAFT 2399953 operating instructions

SpinTouch RapidScreen Adult Height user manual

SpinTouch

SpinTouch RapidScreen Adult Height user manual

Salter 517 Instructions and guarantee

Salter

Salter 517 Instructions and guarantee

Radio Shack Wireless Indoor/Outdoor Thermometer owner's manual

Radio Shack

Radio Shack Wireless Indoor/Outdoor Thermometer owner's manual

TFA LOGOneo instruction manual

TFA

TFA LOGOneo instruction manual

multicomp pro MP780003 manual

multicomp pro

multicomp pro MP780003 manual

ADC Adtemp 418N Instructions for use

ADC

ADC Adtemp 418N Instructions for use

YOKOGAWA TX1001 user manual

YOKOGAWA

YOKOGAWA TX1001 user manual

Balluff BTS M30E0-UUI-H0001-S04G user guide

Balluff

Balluff BTS M30E0-UUI-H0001-S04G user guide

GHM Greisinger G 1781 Compact manual

GHM Greisinger

GHM Greisinger G 1781 Compact manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.