designed in accordance with DIN EN ISO 13857 Table 4
(from the age of 14 up). In the event of deviations, further
structural protective measures must be taken for safe opera-
tion.
ZIEHL-ABEGG centrifugal fans are supplied with IEC
standard motors attached directly to the housings. The fan
impeller is fastened with the hub directly to the motor shaft
Designs (type designation see rating plate):
•RF..P: Drum-type rotors with forward curved blading
•RG..T/RG..C: Radial impellers with rear-curved blading
Safety instructions
•These assembly instructions are part of the product and,
as such, are to be kept accessible at all times.
•The impellers are intended only for the transportation of air
or mixtures that are similar to air. Usage in potentially
explosive areas for the transportation of gas, mist, vapours
or their mixtures is not permissible. The transportation of
solid materials or similar materials in a transport media is
not permissible.
•Operate the fan only in accordance with its intended use
and only up to the maximum permissible operating
speed according to the specifications on the identification
plate. Due to the high kinetic energy exceeding the max.
permissible operating speed leads to a hazardous situa-
tion. The impeller can burst – danger of death! The
max. allowed operating specifications on the identification
plate apply to an atmospheric density of r 1.2 kg/m
3
.
•In order to approve its centrifugal fans with standard
motors, ZIEHL-ABEGG carries out extensive qualification
tests. Depending on the installation conditions and the
other system components in use (e.g. frequency inverter
incl. parameter configuration), in individual cases there
may be unusual noises and vibrations (resonance) caused
by the electrics.
•If the operating voltage differs, the current may change
disproportionately. This must be taken into account when a
selecting possible frequency inverter and the mains side
fuse protection.
•The EMC guideline is to be observed in connection with
our control units. If the fans are completed with compo-
nents of other manufacturers, the manufacturer or operator
of the entire plant is responsible for keeping to the EMC
guideline 2014/30/EU .
•In case of speed control through a frequency converter, it
must be ensured that the max. permissible speed cannot
be exceeded due to any frequency converter malfunction.
•In a fan system consisting of a motor, frequency inverter
and impeller, impermissibly high vibrations can occur in
narrowly limited speed ranges. Continuous duty is not
permissible under these conditions. The impeller could
burst - danger of death!
•Mounting, electrical connection and commissioning may
only be carried out by trained specialized personnel who
observe the relevant regulations!
•Observe the notes in the motor manufacturer’s operating
instructions, which form part of the supply.
•A thermal motor protection device is essential, see Elec-
trical connection chapter.
•If the fan is installed for free-running intake or exhaust,
please check to see whether the safety standards of DIN
EN ISO 13857 are observed. Objects sucked in can be
thrown out by centrifugal force and lead to damage or
severe injury.
•Pay special attention that there is sufficiently dimensioned
safety clearance on the inlet side, as clothes, limbs, or, in
the case of large fans, even people can be sucked in due
to the fan’s suction power.
•Blocking or braking the fan by, say, pushing objects into it
is forbidden. This leads to heated surfaces and damage to
the impeller.
•It is not possible to exclude a residual risk due to incorrect
use, malfunction or force majeure. The designer or
constructor of the installation must take suitable safety
measures in accordance with DIN EN 12100, e.g. protec-
施乐百径流风机连同直接安装在机箱上的IEC标准马达一
供货。风机叶轮直接固定在马达轴上。
系列 ((型名称参见铭牌) ) :
•RF..P: 带前弯式桨叶的鼓形转子
•RG..T/RG..C: 带回弯桨叶的径流叶轮
安全提示
•装配说明书是产品的组成部分,放到触手可及的地方妥善
保存。
•风机只能用于输送空气或类似空气的和气体,不能用于
危险区域或易燃,易爆气体,雾气及其合物的通风,
也不能用于有固体成分的介质的流通。
•按规定用途操作风机,勿超过风机型铭牌上规定的
最大允许运行转速 。超过最大允许运行转速将导致由
于高动能引的危险情况。叶轮可能会断裂——生命危险
!型铭牌上的最大允许运行数据对空气密度 ρ 1.2 kg/
m
3
有效。
•ZIEHL-ABEGG 使用标准电动机进行广泛的资格测试,用
于释放其离心风机。取决于安装情况和使用的其它系统
组件(例如,包括参数设置的变频器),在个别情况下
可能导致声学和振动技术的异常(共振),这是电气造
成的。
•在工作电压不同时,电流可能发生比例过大的变化。在选
择变频器及电源侧熔断装置时,须考虑到这一点。
•带有本公司控制器的风机遵循EMC标准。风机与其他部
件整合后也应遵循EMC标准2014/30/EU。
•当采用变频器控制速度时,必须注意确保即使在变频器发
生故障时也不超过最大允许转速。
•对于由电机、变频器和叶轮构成的风机系统,在较窄的转
速范围内可能发生未获允许的震动。这将导致不能连续
运行的后果。叶轮可能发生断裂,进而导致人员面临生命
危险!
•装配,电连接和调试只能由经过培训专业人员完成,此外
,这些人员还必须遵守 相关规范!
•注意供货范围内马达生产商使用说明书中的注意事项。
•务必使用电机过热保护装置,见电气连接章节。
•若风机安装在自由运行的抽风或排风口,需遵守DIN EN
ISO 13857安全标准,物体吸入被离心力甩出可能会
造成破坏或损伤。
•确保衣物,手臂等离吸风口有足够的安全距离,如果是较
大尺寸的风机,整个人都有可能被吸入的危险。
•禁止向风扇插入异物,阻止其旋转。 这会导致叶轮表面发
热或受损。
•由于不正确使用,功能故障或不可预知力造成的风险是无
法避免的。设备的规划人员或搭建人员必须根据DIN EN 1
2100采取合适的措施(例如安装防护装置)确保防止
危险情况的发生。
2中文english
00280371-GB-VRCL-BAL-007-VRC-2022/07-Index 017