ZippyYum WTB4010 User manual

USER MANUAL
THERMOMETER
iOS &
Android
Works with
Models WTB4010, WTB4010-M
Updated: May 14, 2021
gt-2021-3.png

2
USER
MANUAL
TABLE OF CONTENTS
About 3
Support 4
Features 5
Laser Safety 6
Installing the App 8
Pairing 9
Mounng 12
LED Indicator 14
Surface & Internal Temp 16
Troubleshoong 17
Accuracy Check 20
Cleaning 22
Reset Procedure 24
Distance to Spot 25
Technical Specs 27
IPRang 30
Warranty 33
Cercaons 34
FCC Compliance 35
IC Warning 36

3
USER
MANUAL
ABOUT
The ZippyYum Thermometer is a
super-awesome, one-of-a-kind,
bluetooth, contactless, infrared
thermometer.
It even supports an external probe.
Theprobejackiscompablewith
standard K-type thermocouple
connector probes.
Aninternalbaerychargedwith
a standard USB-C connector
powers the thermometer.
All ZippyYum thermometers are
compablewithbothiOSand
Android phones and tablets.
APPROVED USES
All models are food-grade, but
only model WTB4010-M is rated
for taking a person’s forehead
temperature scan.

4
USER
MANUAL
SUPPORT
ZippyYumoersfreesupportfor
our hardware and apps.
ONLINE RESOURCES
If you need help with your
thermometer, please visit
www.zippyyum.com for support
resources including a knowledge
base.
IN-APP RESOURCES
You can also access the
knowledge base in the Help &
Support area from the main menu
of any ZippyYum app.
CONTACT US
To reach our support team, please
use the Help & Support area from
the main menu of any ZippyYum
app.
You can also email us at
support@zippyyum.com or live
chat with us on our website.

5
USER
MANUAL
FEATURES
LED indicator
&resetbuon
Laser indicator
Infrared sensor
K-type
thermocouple
probe jack
USB-C
charging port

6
USER
MANUAL
LASER SAFETY
The ZippyYum Thermometer
contains a laser pointer compliant
with FDA 21 CFR 1040.10,
subchapter J. Please refer to
thetechnicalspecicaonsfor
addionaldetails.
WARNING!
Avoid directly exposing eyes to
the thermometer’s laser as this
may result in eye damage.
Never point the laser at another
person. When using model
WTB4010-M to take a person’s
forehead temperature the app will
automacallydisablethelaser.
Always keep thermometer out of
the reach of children.
Avoid indirect eye exposure via
reecvesurfacessuchasglass
and mirrors.
If thermometer is damaged, always
perform an accuracy check prior
tousingthermometerforcrical
temperatures.

7
01.
SETUP

8
USER
MANUAL
INSTALLING THE APP
Your ZippyYum Thermometer must
be paired with the GoTemp app on
an iOS or Android device before
being used.
To install the app, tap below or
visit: www.zippyyum.com/apps
Once the GoTemp app is installed,
log into the app using your login
credenals.
Now you’re ready to pair.
TAP TO INSTALL

9
USER
MANUAL
PAIRING
PRO TIP
Your thermometer’s unique
idener,alsoknownasitsMAC
address, is printed on the back of
the device as shown below. You
may need it during pairing.
MAC address

10
USER
MANUAL
PAIRING
Your ZippyYum Thermometer
arrives powered OFF.
Flip it on over and use a thin
toollikeapapercliptoip
the recessed switch to the ON
posion.
PRO TIP
The power switch is recessed for a
reason! The thermometer is meant
tobeleintheONposionatall
mes.Itwillautomacallygointo
power-saving mode when not in
use.

11
USER
MANUAL
PAIRING
TheGoTempappwillautomacally
connect to your thermometer if
only one thermometer is detected.
Iftherearemulplethermometers,
you’llseealistofopons.
Available thermometers will show
as “THERM_##” with ## being the
last two digits of its MAC address.
The LED indicator will blink once a
thermometer is selected.
The ZippyYum Thermometer will
pairautomacallyorpromptyou
for a pairing code. If prompted,
enter code ‘123456’ in the app.
123456
“THERMOMETER” would like to pair
with your device. Enter the pairing code
in your thermometer’s user guide.
Bluetooth Pairing Request
Cancel Pair

12
USER
MANUAL
The ZippyYum Thermometer
aachestoanyphone,case,or
tabletwithaatbackusinga
univeralmounngplate.
Simply clean the area thoroughly
(we recommend isopropyl
alcohol), peel the adhesive
backing,andscktheplateon
your device.
Make sure the raised bar on the
mounngplateishorizontal.
MOUNTING

13
USER
MANUAL
MOUNTING
Next, align the raised tabs on the
mounngplatewiththenotches
in the back of your ZippyYum
Thermometer.
Place the thermometer down onto
themounngplateandslideitto
thesideunlitclicks.
2
1

14
USER
MANUAL
The ZippyYum Thermometer
has an LED indicator to show
baeryinformaonandpairing
connecvitystatustoitsdevice.
INDICATOR OFF
Powero,sleep
mode,ordeadbaery
RED LED
Baerycricallylow,
should be charged
ORANGE LED
Baerycharging,
connuecharging
GREEN LED
Baerycharged,
ready to use
LED INDICATOR
IF FLASHING
Connected to device
IF SOLID OR LED OFF
Not connected to device

15
02.
TAKING
TEMPS

16
USER
MANUAL
The infrared thermometer
measures surface temperature.
Make sure to mix items prior to
taking an infrared temperature to
get an accurate reading.
When internal temperatures
aremorecricalforitemslike
meat cooking on a grill, use the
thermometer’s probe jack to take
an internal probe temperature.
Cold Holding Example: Use your
free, gloved hand to mix or move
the top layer of veggies in a food
pan to get the internal temperature
using infrared.
Hot Holding Example: Use a spoon
to mix hot items like soups prior
to taking their temperature using
infrared.
Cooking Example: Use an external
probe with the thermometer to
checkburgerpaiesonagrill.
SURFACE &
INTERNAL TEMP

17
USER
MANUAL
If your temperatures seem
o,pleasefollowthese
troubleshoongstepspriorto
contacngoursupportteam.
Start by throroughly cleaning the
thermometer following the steps
outlined in this guide. A dirty
infrared lens is the most common
cause of inaccurate infrared
temperatures.
Ifmulpleitemsaretempingout-
of-range, verify your equipment
is turned on and set to the proper
temperature.
If taking infrared temperatures,
verify proper steps are being taken
to take internal temperatures by
followingtheinstruconsonthe
previous page.
WhencontacngZippyYum
supportbepreparedtoidenfy
why you beleive your thermometer
isnotfunconing(likeusing
another thermometer to verify the
temperature, etc.)
TROUBLESHOOTING

18
USER
MANUAL
Make sure food is not covered,
the ZippyYum thermometer can’t
measurethroughglassorplasc.
Steam, dust, smoke, and vapor can
obstruct Scancase’s sensors.
Avoid high humidity environments
withcondensaonwhenusing
infrared.
Avoidmeasuringreecve
surfaces (like aluminum wrapping)
unlessamaesurfaceisontop
(like a label).
When a sudden change of
temperature occurs (like walking
into a freezer), your thermometer
mayneedtobeprecondioned
for up to 15 minutes for accurate
temperatures.
Avoid angling the thermometer
for infrared temperatures. Keep
it perpendicular to the measured
surface for best results.
TROUBLESHOOTING

19
03.
SERVICE &
CLEANING

20
USER
MANUAL
QUICK ACCURACY CHECK
To quickly check the infrared
thermometer,llacupwithiceand
addenoughcoldwaterjusttollin
the gaps between the ice.
Let the ice water sit for 2 minutes,
thensrthoroughly.
Hold the thermometer about 6” to
8” directly above the ice and take
an infrared temperature.
Make sure the thermometer is
pointed straight down and not
angled, otherwise you may be
taking the cup’s temperature
instead of the ice water.
The thermometer should read
about 32.0°F or 0°C. If the
temperature is more than 4°F or
2°C out-of-range, please contact
ZippyYum support.
ACCURACY CHECK
This manual suits for next models
1
Table of contents