Zksoftware MultiBio 700 User manual

(1) Post the mounting template on the
wall.Drill the holes according to
the marks on the template (holes
Version: V1.0 Date: October 2010
(2) Remove the screw on the bottom (3) Take away the back plate.
(5) Fix the device to the back plate.
according to the mounting paper.
(4) Fix the back plate on the wall
RS485 TCP/IP
Lock
Sensor
①
③
Alarm
RS232/RS485 Converter
②
NC LOCK
-
+
DC12V
+
NC LOCK
+
-
NO LOCK
-
-
FR 107
+
-
FR 107
+12V +12V
+12V
+12V
GND GND
GND
GND
NC NC
NC
NC
NC
NO NO
NO
NO
NO
GND GND
GND
GND
GND
COM COM
COM
COM
COM
AL- AL-
AL-
AL-
AL-
AL+ AL+
AL+
AL+
AL+
SEN SEN
SEN
SEN
SEN
BUT BUT
BUT
BUT
BUT
BELL+ BELL+
BELL+
BELL+
BELL+
BELL- BELL-
BELL-
BELL-
BELL-
NO LOCK
-
+
DC12V
+
-
+
-
FR 107
-
+
DC12V
+
-
-
+
DC power
-
+
DC12V
-
+
DC power
+
-
FR 107
+
DC12V
-
+
GND
+12V
Exit Button ⑤
External Reader
④
Door Bell
Door Bell
%
%
BUTTO N
EXIT
EXIT
BUTTO N
⑦
⑥
-
+Alarm
Alarm Power
Exit Button
Door Sensor
Mul tiBio 7 00
(on ly for yo ur refe rence )
Mou nting P aper
10
11
12
Wiri ng Hole
Instru ction fo r the Mo unting P aper
Before t he devic e is fas tened, p leas e
stick th e paper to t he pla ce where y ou
want to in stall it , then m ake hole s and
lay cabl es accor ding t o the moun ting
paper.
for screw and wiring).
of device.
Access Control System Function
(1) If a registered user verified, the device will export the signal
to unlock the door.
(3) If only the d llegal removed, the device will evice being i ly
(4) is External card reader supported.
(5) is it is External exit button supported, convenient to open the
export alarm signal.
door inside.
(7) Supports , modes with RS485 TCP/IP to connect PC. One PC can
manage multiple devices.
(6) External door bell is supported.
①: ‘‘I’: device output current, ‘ ’: lock voltage, ’: lock currentULOCK ILOCK
(1) The system supports NO LOCK and NC LOCK. For example the NO LOCK (normally open at power on) is connected
with ’NO’ terminal, and the NC LOCK is connected with ‘NC’ terminal.
(equipped in the package) to prevent the self-inductance EMF affect the system, do not re verse the polarities.
3.Lock Connection
!
Warning: No operating with power on
(1) Share power with the lock:
A. ULOCK=12V, I-ILOCK>1A…… ①
B. The lock is near to the device.
Device share power with the lock:
Device does not share power with the lock:
A. =12V I- ≤1A;ULOCK ILOCK
B ≠12V; . ULOCK
C. The lock is far apart from the device.
Voltage output ≤ DC 12V for Alarm
4. Other Parts Connection:
5. Power Connection:
Input DC 12V, 500mA (50mA standby)
Positive is connected with ‘+12V’, negative is connected
with ’GND’ (do not reverse the polarities).
(2) Does not share power with the lock:
2. Structure and Function
(2) Door sensor will detect the on-off state. If the door is un-
expected opened or improperly closed, the alarm signal
(digital value) will be triggered.
MultiBio 700 Installation Guide
1. Equipment Installation
(2) When the Electrical Lock is connected to the Access Control System, you need to parallel one FR107 diode

DATA1
DATA0
GND
+12V
GLED
RLED
BEEP
485+
485-
TXD
RXD
GND
GND
WD 0
WD 1
DATA0
GND
DATA1
Access Control
IWD1
12Vout
BEEP
GLED
RLED
IWD0
GND
IP Address:192.168.1.100
Subnet Mask:255.255.255.0
IP Address:192.168.1.124
Subnet Mask:255.255.255.0
Switch
PC
…
Side View Back View
Tamper Switch
Reset Button
(1) RS232 Mode:
Terminals:
RXD Pin3-Txd
TXD Pin2-Rxd
GND Pin5-Gnd
485+ RS485+
485- RS485-
485+
485-
485+ 485-
RS485 Bus
485+ 485- 485+ 485-
RS485
10. Cautions:
6. Wiegand Output
The device supports standard Wiegand 26 output,
so you can connect it with most of the access control
7. Wiegand Input
connect with card reader. Theyan independent are installed each
The device has the function of Wiegand input upports to signal . It s
Wiegand signal extender in long distance or interference environment).
(2) To keep the stability of Wiegand signal, connect the device and the Access Control or Card Reader in same ‘GND’
(1) Please keep the distance between the device and Access Control or Card Reader less than 90 meters(Please use
There are three modes that the PC software communicate
and TCP/IP, and the last two modes support remote control.
9. Communication
8.Other Functions
(1) Manual Reset:
(2) Restore Factory Settings:
(A) Crossover cable: The device and PC connected
(B) Straight cable: The device and PC connected to
(3) TCP/IP Mode:
(2) RS485 Mode:
etc. More information please refer to the user manual.
Operation: Press the tamper switch three times after the alarm being
You can use the tamper switch to restore factory settings, such
Note: The user data won’t be cleared.
other restart it.abnormality, you can use ‘Reset’ function to
hole with than 2mm).a sharp tool (the tip diameter less
Operation: Remove the black rubber cap, then stick the Reset button
If the device does not work properly because of misoperation or
as device number, system password, IP address, RS485 address,
triggered 30 seconds but no more than 60 seconds.
Terminals PC Serial Ports
(2)We recommend the 3A/12V DC Power supply. Please contact our technical staff for details.
(5)Please connect the ‘GND’ before all the other wiring especially under the environment with much electrostatic.
( )3Please read carefully the terminal description and wiring by rule strictly. Any damage caused by improper
(4)Keep the exposed part of wire less than 5mm, to avoid unexpected connection.
(6)Do not change the cable type because of long distance between the power and the device.
(1)Power cable is connected after all the other wiring. If the device is working abnormally, please shut down the power
first, then make the necessary check . Kindly reminds you that any hot-plugging may damage the device, and
operations will be out of the range of our guarantee.
it is not included in the warranty.
Terminals PC Serial Ports
Converter
!
Warning: No operating with power on
in any case.
side of the door, to control the lock and access together.
Please use specified RS485 wire, RS485 active converter and
bus-type wiring.
and exchange information with the device: RS232, RS485
Terminals:
LAN/WAN through switch/Lanswitch.
directly.
(7) Please use specified RS485 wire, RS485 active converter and bus-type wiring.
devices by now.