(1) Post the mounting template on the
wall.Drill the holes according to
the marks on the template (holes
Version: V1.0 Date: October 2010
(2) Remove the screw on the bottom (3) Take away the back plate.
(5) Fix the device to the back plate.
according to the mounting paper.
(4) Fix the back plate on the wall
RS485 TCP/IP
Lock
Sensor
①
③
Alarm
RS232/RS485 Converter
②
NC LOCK
-
+
DC12V
+
NC LOCK
+
-
NO LOCK
-
-
FR 107
+
-
FR 107
+12V +12V
+12V
+12V
GND GND
GND
GND
NC NC
NC
NC
NC
NO NO
NO
NO
NO
GND GND
GND
GND
GND
COM COM
COM
COM
COM
AL- AL-
AL-
AL-
AL-
AL+ AL+
AL+
AL+
AL+
SEN SEN
SEN
SEN
SEN
BUT BUT
BUT
BUT
BUT
BELL+ BELL+
BELL+
BELL+
BELL+
BELL- BELL-
BELL-
BELL-
BELL-
NO LOCK
-
+
DC12V
+
-
+
-
FR 107
-
+
DC12V
+
-
-
+
DC power
-
+
DC12V
-
+
DC power
+
-
FR 107
+
DC12V
-
+
GND
+12V
Exit Button ⑤
External Reader
④
Door Bell
Door Bell
%
%
BUTTO N
EXIT
EXIT
BUTTO N
⑦
⑥
-
+Alarm
Alarm Power
Exit Button
Door Sensor
Mul tiBio 7 00
(on ly for yo ur refe rence )
Mou nting P aper
10
11
12
Wiri ng Hole
Instru ction fo r the Mo unting P aper
Before t he devic e is fas tened, p leas e
stick th e paper to t he pla ce where y ou
want to in stall it , then m ake hole s and
lay cabl es accor ding t o the moun ting
paper.
for screw and wiring).
of device.
Access Control System Function
(1) If a registered user verified, the device will export the signal
to unlock the door.
(3) If only the d llegal removed, the device will evice being i ly
(4) is External card reader supported.
(5) is it is External exit button supported, convenient to open the
export alarm signal.
door inside.
(7) Supports , modes with RS485 TCP/IP to connect PC. One PC can
manage multiple devices.
(6) External door bell is supported.
①: ‘‘I’: device output current, ‘ ’: lock voltage, ’: lock currentULOCK ILOCK
(1) The system supports NO LOCK and NC LOCK. For example the NO LOCK (normally open at power on) is connected
with ’NO’ terminal, and the NC LOCK is connected with ‘NC’ terminal.
(equipped in the package) to prevent the self-inductance EMF affect the system, do not re verse the polarities.
3.Lock Connection
!
Warning: No operating with power on
(1) Share power with the lock:
A. ULOCK=12V, I-ILOCK>1A…… ①
B. The lock is near to the device.
Device share power with the lock:
Device does not share power with the lock:
A. =12V I- ≤1A;ULOCK ILOCK
B ≠12V; . ULOCK
C. The lock is far apart from the device.
Voltage output ≤ DC 12V for Alarm
4. Other Parts Connection:
5. Power Connection:
Input DC 12V, 500mA (50mA standby)
Positive is connected with ‘+12V’, negative is connected
with ’GND’ (do not reverse the polarities).
(2) Does not share power with the lock:
2. Structure and Function
(2) Door sensor will detect the on-off state. If the door is un-
expected opened or improperly closed, the alarm signal
(digital value) will be triggered.
MultiBio 700 Installation Guide
1. Equipment Installation
(2) When the Electrical Lock is connected to the Access Control System, you need to parallel one FR107 diode