7
2. Set the Wiegand Output Mode
Press *#→ Input the administrator password →8→5→0/1/2/3→#
0: Wiegand 26, 1: Wiegand 34(default), 2: reserved, 3: Wiegand 66.
3. Set the Reader Address
Press *#→ Input the administrator password →8→6→1~32→#
Set the reader 485 address. The value ranges from 1 to 32.
4. Set the Keystroke Sound
Press *#→ Input the administrator password →8→7→0~9→#
The number from 0 to 9 corresponds to different sounds.
5. Set the Background Light
Press *#→ Input the administrator password →8→8→0/1/2 →#
0: normally close, 1: normally open, 2: breathing light.
6. Restore the Default Settings
First, remove the screws from the bottom, and then long press the mounting
reset button at the bottom for 4 seconds until the blue indicator lights up four
times, the buzzer rings for four times, and then the buzzer buzzes for one
short time. The device is restored to default settings.
*Images in this guide are for reference only. Refer to the actual product before purchasing.