1. Check to be sure your power source is capable of handling the
voltage requirements of the motor, as indicated on the pump
name plate.
2. These pumps are not designed or intended to be used to handle
sewage or effluent.
3. This pump has been evaluated for use with WATER only.
4. Maximum continuous operating water temperature for standard
model pumps must not exceed 104°F (40°C).
5. These pumps are not designed or intended to be used as a
primary or backup sump pump.
Note: Pumps with the "CSA" mark are tested to CSA Standard
C22.2 No. 108.
REFER TO WARRANTY ON PAGE 2.
PERFORMANCE
Your pump is designed to effectively pump all clear storm and drain
waters. Although it will usually pass small particles suspended in
water; grass, heavy mud, sand or pea gravel can clog the pump
and reduce pump performance. This can usually be cleaned out by
backflushing with a garden hose through the discharge. The normal
performance that can be expected is as follows:
HP
GALLONS PER HOUR AT
DISCHARGE HEIGHT ABOVE
PUMPING LEVEL
SHUT-OFF
HEAD
5 Ft. 10 Ft. 15 Ft.
1/4 1800 1320 720 20 Ft.
DO NOT USE FOR PUMPING OILS, GASOLINE OR ANY PETROLEUM BY-PRODUCTS.
Notice to Installer: Instructions must remain with installation.
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before
using. DO NOT remove the test plug in the cover.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials
should be retained for future reference.
1. Make sure there is a properly installed ground fault circuit inter-
rupter (GFCI) protected circuit available. All pumps are furnished
with provisions for proper grounding to help protect you against
the possibility of electrical shock.
2. Make certain that the ground fault receptacle is within the reach
of the pump’s power supply cord. DO NOT USE AN EXTENSION
CORD. Extension cords that are too long or too light do not
deliver sufficient voltage to the pump motor. But, more important,
they could present a safety hazard if the insulation were to be-
come damaged or the connection ends were to fall into water.
3. Make sure the pump electrical supply circuit is equipped with
fuses or circuit breakers of proper capacity. A separate branch
circuit is recommended, sized according the National Electrical
Code for the current shown on the pump name plate.
4. TESTING FOR GROUND. As a safety measure, each electrical
outlet should be checked for ground using an Underwriters
Laboratory Listed circuit analyzer which will indicate if the power,
neutral and ground wires are cor
rectly connected to your outlet. If
they are not, call a qualified licensed electrician.
5. Installation and checking of electrical circuits and hardware
should only be performed by a qualified licensed electrician.
6. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING.
7. These pumps are supplied with a 3-prong grounded plug to help
protect you against the possibility of electrical shock. DO NOT
UNDER ANY CIRCUMSTANCES REMOVE THE GROUND
PIN. The 3-prong plug must be inserted in a mating 3-prong
fault interrupter receptacle. If the installation does not have such
a receptacle, it must be changed to the proper type, wired, and
grounded in accordance with the National Electrical Code and all
applicable local codes and ordinances.
8. Risk of electric shock. This pump has not been tested for use in
swimming pool or marine areas.
9. According to the state of California (Prop 65), this product con-
tains chemicals known to the state of California to cause cancer
and birth defects or other reproductive harm.
SEE BELOW FOR LIST OF CAUTIONS
SEE BELOW FOR LIST OF WARNINGS
INSTALLATION INSTRUCTIONS
MODEL: LM44
SECTION: 6.10.014
FM2427
0207
Supersedes
New
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies. MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
visit our web site:
www.zoeller.com
© Copyright 2007 Zoeller Co. All rights reserved. P/N 022508
NOTE: Ratings based on 1-1/4" pipe with friction loss neglected. Us-
ing 3/4" garden hose adapter, performance will be reduced approxi-
mately 15%. This pump does not deliver enough pressure to operate
lawn sprinklers properly.
OPERATION
1. Set pump on hard surface in water before starting.
2. Use the included garden hose adapater for 3/4" discharge line or
disconnect the adapter to use a 1-1/4" discharge.
3. Plug power cord into properly grounded 115 volt AC power outlet.
(See recommended grounding methods on front page). Will oper-
ate continuously whether partly or fully submerged. Submersible
utility pumps are intended to pump water at temperatures up to
104˚F (40˚C).
4. When the pump senses that it is no longer pumping water, the
pump will shut off automatically. The pump will then turn on every
three minutes for 5 seconds and then off if it does not sense any
water.
5. If water is sensed after the pump begins running, the pump will
continue pumping until the pump senses that it is no longer
pumping water.
6. To prevent unnecessary wear, unplug the pump from the power
output when not in use.
7. The pump is supplied with a 3/4" garden hose adapter. For use
with plastic pipe, remove the adapter and install the desired
1-1/4" NPT fitting. DO NOT OVERTIGHTEN THE HOSE OR
PLASTIC ADAPTER FITTING. Finger tight plus 1/2 turn is
sufficient.
Do not set pump directly on sand, dirt or mud.
Sand or mud-choked pumps can be back-
flushed clean.
Do not handle or carry the pump by the power
cord. Use the handle.
Extended usage of the pump in a partially
submerged or non-submerged situation may
cause the pump to overheat due to lack of heat dissipation from the
water. If this occurs, the pump will shut itself off until the motor cools
to its normal temperature. Repeated overheating may cause dam-
age to the pump.
MAINTENANCE
1. The motor housing of the pump is completely sealed and requires
no service. Disassembly of the motor housing or alteration of the
power cord voids all warranty.
2. The motor is a continuous duty type with an automatic thermal
overload protector device.
3. The pump can run against a partially restricted discharge, but
is designed to move large volumes of water with minimal back
pressure.
4. If the pump becomes clogged, remove the screen and clean out
the area.
5. Debris in the intake should be routinely removed from the bottom
of the pump to prevent damage to the pump, which will void the
warranty.
6. If necessary, remove the eight (8) screws holding the volute base
to the motor housing and clean the volute.
Manufacturerwarrants,tothepurchaserandsubsequentownerduringthewarranty
period, every new product to be free from defects in material and workmanship
under normal use and service, when properly used and maintained, for a period
of one year from date of purchase by the end user, or 18 months from date of
original manufacture of the product, whichever comes first. Parts that fail within
the warranty period, one year from date of purchase by the end user, or 18
months from the date of original manufacture of the product, whichever comes
first, that inspections determine to be defective in material or workmanship, will
be repaired, replaced or remanufactured at Manufacturer's option, provided how-
ever, that by so doing we will not be obligated to replace an entire assembly, the
entire mechanism or the complete unit. No allowance will be made for shipping
charges, damages, labor or other charges that may occur due to product failure,
repair or replacement.
This warranty does not apply to and there shall be no warranty for any material
or product that has been disassembled without prior approval of Manufacturer,
subjectedtomisuse, misapplication, neglect, alteration, accident oractof God; that
has not been installed, operated or maintained in accordance with Manufacturer's
installation instructions; that has been exposed to outside substances including
but not limited to the following: sand, gravel, cement, mud, tar, hydrocarbons,
hydrocarbonderivatives(oil,gasoline, solvents, etc.), or other abrasive or corrosive
substances,wash towels or feminine sanitary products, etc. in allpumping applica-
LIMITED WARRANTY
tions. The warranty set out in the paragraph above is in lieu of all other warranties
expressed or implied; and we do not authorize any representative or other person
to assume for us any other liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211,
Attention:CustomerServiceDepartmenttoobtainanyneeded repair or replacement
of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIALOR INCIDENTALDAMAGES OR BREACH OF EXPRESSED
OR IMPLIED WARRANTY; AND ANYIMPLIED WARRANTY OF FITNESS FOR
APARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED
TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty, so
the above limitation may not apply to you. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights
which vary from state to state.
© Copyright 2007 Zoeller Co. All rights reserved.
MAIL TO: P.O. BOX 16347
Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road
Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP
FAX (502) 774-3624
Manufacturers of . .
www.zoeller.com

Other Zoeller Water Pump manuals

Zoeller Qwik Jon Ultima 204 User manual

Zoeller

Zoeller Qwik Jon Ultima 204 User manual

Zoeller Basement Sentry Series User manual

Zoeller

Zoeller Basement Sentry Series User manual

Zoeller AquaNot 508 Spin User manual

Zoeller

Zoeller AquaNot 508 Spin User manual

Zoeller SHARK Series Installation and maintenance instructions

Zoeller

Zoeller SHARK Series Installation and maintenance instructions

Zoeller 370-0002 User manual

Zoeller

Zoeller 370-0002 User manual

Zoeller AQUANOT 508 Fit User manual

Zoeller

Zoeller AQUANOT 508 Fit User manual

Zoeller 62 HD Series User manual

Zoeller

Zoeller 62 HD Series User manual

Zoeller AQUANOT SPIN 508 User manual

Zoeller

Zoeller AQUANOT SPIN 508 User manual

Zoeller Aquanot 508 User manual

Zoeller

Zoeller Aquanot 508 User manual

Zoeller 81 Series User manual

Zoeller

Zoeller 81 Series User manual

Zoeller 64 HD Series Operating instructions

Zoeller

Zoeller 64 HD Series Operating instructions

Zoeller 810 User manual

Zoeller

Zoeller 810 User manual

Zoeller QWIK JON ULTIMA 203 User manual

Zoeller

Zoeller QWIK JON ULTIMA 203 User manual

Zoeller 820 User manual

Zoeller

Zoeller 820 User manual

Zoeller The Shark Series Installation and maintenance instructions

Zoeller

Zoeller The Shark Series Installation and maintenance instructions

Zoeller Basement Sentry Series User manual

Zoeller

Zoeller Basement Sentry Series User manual

Zoeller 840 User manual

Zoeller

Zoeller 840 User manual

Zoeller QLS Series User manual

Zoeller

Zoeller QLS Series User manual

Zoeller N153 User manual

Zoeller

Zoeller N153 User manual

Zoeller SHARK Series User manual

Zoeller

Zoeller SHARK Series User manual

Zoeller 71 Series User manual

Zoeller

Zoeller 71 Series User manual

Zoeller EX6220 User manual

Zoeller

Zoeller EX6220 User manual

Zoeller QWIK JON ULTIMA QJU-3 User manual

Zoeller

Zoeller QWIK JON ULTIMA QJU-3 User manual

Zoeller QWIK JON ULTIMA 202 User manual

Zoeller

Zoeller QWIK JON ULTIMA 202 User manual

Popular Water Pump manuals by other brands

Becker DVT 3.60 operating instructions

Becker

Becker DVT 3.60 operating instructions

Riken Keiki PT9E-0137 operating manual

Riken Keiki

Riken Keiki PT9E-0137 operating manual

Rapid GTK 200/3-E Operation manual

Rapid

Rapid GTK 200/3-E Operation manual

Groz EDR-55 instruction manual

Groz

Groz EDR-55 instruction manual

Tunze Turbelle nanostream 6015 Instructions for use

Tunze

Tunze Turbelle nanostream 6015 Instructions for use

Wilo RAIN1 Series Installation and operating instructions

Wilo

Wilo RAIN1 Series Installation and operating instructions

Graco Xtreme 116MCN Instructions-parts list

Graco

Graco Xtreme 116MCN Instructions-parts list

Agilent Technologies InfinityLab LC Series user manual

Agilent Technologies

Agilent Technologies InfinityLab LC Series user manual

Husqvarna W25P Operator's manual

Husqvarna

Husqvarna W25P Operator's manual

EINHELL ROYAL TMP 255-S operating instructions

EINHELL

EINHELL ROYAL TMP 255-S operating instructions

Grundfos NK Series Installation and operating instructions

Grundfos

Grundfos NK Series Installation and operating instructions

hillvert HT-SP-104 user manual

hillvert

hillvert HT-SP-104 user manual

Wilo Initial JET Installation and operating instructions

Wilo

Wilo Initial JET Installation and operating instructions

Marco 164 002 12-US - UP3-P 12V Instructions for use

Marco

Marco 164 002 12-US - UP3-P 12V Instructions for use

BUSCH Mink MV 1202 A instruction manual

BUSCH

BUSCH Mink MV 1202 A instruction manual

sauermann Si-1830 manual

sauermann

sauermann Si-1830 manual

Macnaught BOP20 owner's manual

Macnaught

Macnaught BOP20 owner's manual

Orion 22802 user manual

Orion

Orion 22802 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.