zogics NSpire PRO Premium H13 HEPA User manual

User Manual

Thank you for purchasing Zogics NSpire H13 HEPA Air Filtration System.
Please read this user manual carefully before you use the appliance.
After reading this manual, keep it in a convenient location for further reference.
Contents
Performance Indicators 1
Packing List 2
Filter Features 2
Product Overview 4
Circuit Diagram 4
Install Filter 5
Control Overview 6
Function Descriptions 8
Installation Notice 9
Safety Precautions 10
Mandatory Items 12
Cleaning and Maintenance 13
Replacing the Filters 15
Troubleshooting 16

1
• For product maintenance and lter replacement cleaning information, please refer to the
instruction manual
• Purication performance parameters are tested under specic third-party laboratory
conditions with specic dust particles and formaldehyde gas as target pollutants
• The recommended area is calculated according to (0.07~0.12) xCADR particles, which
is the theoretical value. With different use environment and building structures, the applicable
area will also change due to various factors such as the degree of indoor pollution.
Performance Indicators
SKU
Product Name
Rated Voltage
Rated Frequency
Power
Noise (Low)
Ionizer
CADR (PM2.5)
CCM (PM2.5)
CADR (Formaldehyde)
CCM (Formaldehyde)
Application Area
Filter Replace Time
Net Weight
Product Size
Packing Size
Purication
NSP-HEPA
Zogics NSpire H13 HEPA Air Filtration System
110V–120V~
50Hz/60Hz
80W
≤29.4dB
706 ft3
11,300 ft3/h
P4
2,825 ft3/h
F4
236~409 ft2
Filter #1: 2 years
Filter #2 & 3: 6 months
18.75 lbs
14.5″ x 7.7″ x 26.2″
16.5″ x 10″ x 28.3″
Pre-lter, Cold-catalyst, Activated carbon removal lter,
Antibacterial lter, HEPA lter, UV Sterilization,
Anion release

2
NSpire H13 HEPA Air Filtration System x 1
Remote Control x 1
Filters x 3
User Manual x 1
Aluminum Pre-Filter
Removes large granule dust, dander, pollen, oating compounds and other pollutants.
Washable and reusable.
Cold Catalyst Filter
The cold catalyst will play a catalyst effect in a normal living environment without any external
assistance like UV light, sunlight, high temperature or pressure.
The cold catalyst deals with formaldehyde, ammonia, benzene, TVOC, hydrogen sulde
and other harmful gases released by plywood, furniture, wallpapers, carpets, curtains
and bedspreads.
Honeycomb Activated Carbon Filter
The honeycomb activated carbon carries ecient additives. It features good absorption and
dust collection characteristics.
Antibacterial Filter
The 5 microns lter with antimicrobial agents can eciently kill bacteria in the air.
High Eciency H13 HEPA Filter
The precision of the HEPA lter is 0.01 micron, and it is able to eliminate particles which are
larger than 0.01 micron with a ltration rate of 99% or more. Dust, bacteria, fungi, viruses,
allergens and other small and tiny particles are not able to get through the HEPA lter.
Packing List
Filter Features

3
Filter Features (cont.)
UV Sterilizing Light
A variety of bacteria can be killed by the 365nm UV light. The UV germicidal lamp is used to
purify the air and eliminates odor caused by smoke and mold.
Anion Release
The ionizer releases a large amount of anions and makes the oxygen negatively-charged,
thus gathering positively-charged particles like oating dust, bacteria, viruses and smoke.
The particles become denser and sink to the ground. The smaller the particle size, the
higher the capture rate.

4
Product Overview
Circuit Diagram

5
Install Filter
1. Take out lter from machine 2. Install lter and front panel
• Open the cover • Install lter 3 (Antibacterial + HEPA Compound Filters)
Note: Please ensure the tab side is facing you.
• Install lter 2 (Cold catalyst + Activated carbon removal
compound lters) Note: Please ensure the tab side is
facing you.
• Install lter 1 (Pre-Filter) Note: Please ensure the handle
side is facing you.
• Install front plate
• Take out the lters
• Remove all packaging material;
Filters are wrapped in plastic, this
MUST be removed before use

6
Control Overview
Touch the power button at standby mode. Machine will start at the last time running
mode (not including timer and sleep mode). Machine will go into standby mode
after pressing the power button when it is on running mode. It will record the current
operation mode at the same time. Note: The machine includes panel switch and
anti-fall switch. Machine will not turn on when the panel is removed or the machine
falls down.
All buttons will disable when the child lock is pressed. The child lock icon will light up
and the unit will keep running. Press this button for 3 seconds to exit this mode.
Ionizer will turn on/off when you press this button. The icon will light up and off
accordingly. Motor will turn on and stay at low speed mode if you press this button
while on standby mode.
Press this button to set the working time. Every press increases the time by 30
minutes. It will recycle after 12 hours. You can press 3 seconds to exit this mode. The
machine will go into standby mode and exit timer mode if you press this button but
the machine is not on purifying mode.
1. Switch the unit on
2. Select the operating mode

7
This function can be engaged when you press the UV sterilize button when the
machine is running. Icon will light up or off at the same time. Motor will turn on and
stay at low speed mode if you press this button on standby mode.
This button puts the machine into auto mode, and the “Auto” indicator lights up on
the panel. Under this mode, according to the degree of air pollution, the machine will
automatically start working and adjust to the correct air volume: PM2.5<60 (Low
speed), 60≤PM2.5<150 (Medium speed), PM2.5≥150 (High speed)
The display panel and light will turn off when sleep mode starts. Motor will only work
at low speed. Timer is available in this mode. Machine will be in standby mode after
the time setting nishes. Press any button to exit sleep mode.
Press this button to adjust the motor speed to Low (500RPM), Medium (700RPM),
High (900 RPM) and let the machine exit auto mode. The motor speed won’t be
controlled by the sensor if it’s modied without permission.
Press child lock for 5 seconds when at normal working mode (child lock mode will
not start), it will show accumulated working time of the lter. It will disappear after
3 seconds.
When the machine is running, it will turn into standby mode when pressing
this button.
3. Power off

8
Function Descriptions
1. Remote Control
The product is equipped with a remote control, which uses a button cell battery (if you don’t
use the remote control for a long time, please take out the battery). Note: The buttons on the
remote control correspond to the buttons on the operation panel. Operation methods are
exactly the same.
2. Product Use
Intelligent operation: Connect the machine to a power supply, press the power button and the auto button,
and the machine will run using the sensor. The operation of the motor gear will follow the sensor’s adjusted
value. This operation can be used for the vast majority of applications.
Personalized operation: Connect the machine to a power supply, press the power button, choose your fan
speed selection, and select on or off negative ions and the UV germicidal lamp.
When running the above two kinds of operating modes at night, as long as the sleep button is set, this will
reduce the fan speed to low, and lessen the noise from the unit.
Regular operation: Simply press the timer icon to set the machine’s running time, and it will stop running
automatically after the time is up. (If you need to cancel, press the timer icon on the panel 3 seconds to
cancel this function.)
Child Lock mode: When in child lock mode, the control panel and buttons on the remote control can not
work. To cancel, press the child lock button 3 seconds or press the unlock button on the remote control).
3. To Set the Time
Press the smart key for 5 seconds to bring up the time display: when the Hour digits are ashing, press the
speed key to add 1, press the sleep button to subtract 1, set ”Hour” by clicking the smart key again.
When ”Minutes” digits are ashing, press the speed button to add 1, press the sleep button to subtract 1.
(Press the smart key back and forth for hours and wind speed. Press the wind speed and the sleep button
to add or subtract).
Note: The clock function of this machine is completely independent, time display function accuracy does
not affect the purication.
The battery is powered by the circuit board of the machine, and it will run out if the machine is not plugged
in. The battery is designed for 10 days standby and will run out if the machine is unplugged for more than
10 days. The clock function automatically resets when this happens. You will need to set the clock again.

9
Installation Notice
1. Do not place it on the following:
• Direct sunlight or facing the outlet of an air conditioner, or direct heat. May
cause deformation, deterioration, discoloration and malfunction.
• Close to televisions and radios and other nearby equipment. Please place the
unit more than 3 feet away.
3. In order to make effective air circulation in the room:
There should be a gap of at least 8″ at both sides and back of the product, and
12” from the top surface.
4. Do not place anything on the product, otherwise it may cause the
unit to malfunction.
5. Do not block the air inlet and outlet. For example, do not place
anything on the outlet or front air inlet.
2. This product should be placed on the ground.
Pollen, dust and other easily fall near the oor, it is recommended that the
product be placed on a at oor in the room.

10
Safety Precautions
1. Do not lift or move the machine when it is working.
Never pull the cord when moving or storing, this may cause a short circuit or
damage to the power cord, starting a re or an electric shock.
2. Do not damage the power cord or plug, do not cut, excessively
twist, pull or use a reverse power line.
If the power cord is damaged, to avoid danger, the cord must be replaced by the
manufacturer, maintenance department or professional staff.
3. Do not use beyond the rated power, universal socket or
connected devices, this may cause the cord to overheat and cause
a re/accident.
4. Do not touch the power plug with wet hands, it may cause
electric shock.
5. Do not place ngers or metal objects into the air outlet gap,
this may cause electric shock.
6. Do not let water, ammable detergent or other liquid into the unit,
this may cause electric shock or re.

11
7. This product is not supposed to be used as a daily ventilator, dust
cleaner or cooker hood.
8. Do not use this product near gas appliances, heating devices
or stoves.
9. Do not use this product in a humid or high-temperature
environment (bathroom, kitchen).
10. Do not allow children to have access to the remote control.
11. Do not place in unstable places
(Products may drop, be overturned, resulting in injury, causing leakage, electric shock or re).
12. Do not use air lter in an aromatherapy scented or disinfecting/insecticide environment
(chemical residues may accumulate in the machine, then be released from the outlet causing harm to
your health).
13. After using a disinfectant or insecticide, you should thoroughly ventilate the room before
using the air lter.

12
Mandatory Items
1. When the following occurs, please immediately turn off the power to the machine
(May cause electric shock, sparks, or smoke)
• Abnormal sound or vibration during operation
• Product odor, burnt smell
2. Please regularly clean the power plug
(May cause electric shock, sparks, or smoke)
• Pull out the power plug, wipe with a dry cloth
• If you won’t be using the unit for long time, please unplug
3. Before maintenance, make sure to disconnect the power
• Products may suddenly start, causing electric shock and injury
4. Please safely insert the plug into the socket
• Do not use damaged plug or loose power socket
5. Please hold the plug insulation parts to pull out power plug
• Using the power cord to pull off the plug from the power cord may cause
power cord damage, electric shock, short circuit, and/or re
6. When any of the following occurs, please immediately turn
off the machine
• A switch does not work
• The power cord or plug abnormally heats up
• Abnormal sound or vibration
• Any anomalies or malfunctions
7. Non-professional people are not allowed to install or uninstall the machine
For IEC:
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance. If the power cord is damaged, it must be
replaced by the manufacturer, its service agent or similarly qualied persons in order to avoid a hazard.

13
Cleaning and Maintenance
For EN:
This appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
1. Pre-Filter (Every 15 days)
• Please use a vacuum cleaner to clean the dust on the surface of the screen, or wash
with water, dry thoroughly.
2. Cellular-Activated Carbon Filter (Every 2 months)
• Use a vacuum cleaner to clear the dust on the surface of the screen.
• Place the lter into a ventilated place. Don’t expose the lter to strong sunshine.
• Do not forcibly hold the lter.
• Do not use water to clean the lter.
3. Antibacterial / HEPA Filter (Every 2 months)
• Place the lter into a ventilated place. Don’t expose the lter to strong sunshine.
• Do not use water to clean the lter.

14
Cleaning and Maintenance (cont.)
4. Negative Ion Generator
5. Particle Sensor (every 2 months)
If the machine creaks, use the brush pen as
a cleaning tool, and regularly clean the dust
around the negative ion.
• With a dry cotton swab, regularly clean the lens to remove the moisture and smoke.
• Remove the outer cover of the particle sensor (g 1), use the dry cotton swab to clean the lens (g 2).
• Please disconnect the power before cleaning.
Cleaning and Maintenance Tips
• Disconnect the power before cleaning and maintenance
• Do not open the machine when removing the lter
• Please unplug if the machine is not in use for a long time
• According to locations and air quality (e.g. a family with many smokers or a place with serious pollution),
the lter life will be shortened. Please replace the lter accordingly.

15
A. Press the middle of the front panel to pop the upper button out of its position
B. Pull out the front panel
C. Take out the lters one by one
D. Fill in new lters one by one in a correct sequence
1. Pre-Filter
2. Cellular-Activated Carbon / Cold Catalyst Filter
3. Antibacterial / HEPA Filter
• We suggest maintaining No.1 lter every 15 days
• We suggest maintaining No.2 and No.3 lters every 60 days
• We suggest replacing No.1 lter in every 2 years
• We suggest replacing No.2 & No.3 lters every 6 months
Filter change reminder
The machine has a lter change reminding function. It’s set at 1500 hours. Please replace No.2 and
No. 3 lters when the “change” icon lights up. Also please press the child lock button for 5 seconds to
reset this function.
Replacing the Filters

16
Troubleshooting
Can not turn on or unit has
no response
The air is dirty, but the
indicator still shows a green
color, even after continuous
operation, the indicator is
always displayed in red.
Sound during operation
The unit is outputting a
strange smell
Unit does not go into sleep
mode automatically at night.
The lter has been running
for a long time, but the air
quality has not improved.
Display shows “F1” or “F2”
1. Is the power cord plugged in?
• Plug in the power.
2. Is the machine front plate covered?
• Cover the front plate
3. Is the machine in the Child-lock mode?
• When the display shows “child-lock” press the child-lock
button 5 seconds until the light is off.
4. The machine is in a at place?
• Put the machine on a at surface.
1. Is the machine located in a place that does not easily
absorb the dirty air?
• Change the location.
2. Particle sensor is dirty?
• Clean the sensor.
The negative ion generator is dusty?
• Clean the negative ion generator.
1. Is the lter dirty?
• Clean the lter.
2. Has the lter not been changed for a long time?
• Replace with a new lter.
Is the unit in manual mode?
• Press “Auto” button on the control panel
1. Have you removed the lter bag ?
• Please remove the lter bag before using the rst time.
2. Is the installation order of the lters wrong?
• Follow the proper lter Installation sequence.
Please turn off the power immediately and contact the
manufacturer for maintenance.
Problem Solution


888.623.0088 • [email protected] • zogics.com
Other manuals for NSpire PRO Premium H13 HEPA
1
This manual suits for next models
1
Table of contents
Other zogics Air Cleaner manuals