USER MANUAL
Z-WAVE WATER SENSOR
Z-Wave Plus Certified Device
FEATURES
- Reliable water and leak detection
- Wireless notifications and event triggers (when included to a Z-Wave gateway controller)
- Built-in audio and visual alarms
- Low battery alerts
- Z-Wave Plus with improved 500 chip for faster and safer wireless communication
- Flexible installation with 2 mounting options
SPECIFICATIONS
Model Number: ZSE30
Z-Wave Signal Frequency: 908.42 MHz
Power: 1 CR2 battery (included)
Power Consumption: 0.13W
Operating Temperature: 32 –104 F
Range: Up to 100 feet line of sight
Installation and Use: Indoor only
Dimensions: 2.5”x 0.9”
Weight: 2 oz
BEFORE YOU RETURN IT
Let us know if you are having any issues installing or operating the device.
Get more helpful tips at getzooz.com
ZSE30

INSTALLATION
WAIT!
Include the Water Sensor to your Z-Wave network and test before mounting it.
Z-WAVE INCLUSION
1. Bring the Water Sensor within direct range of your controller
2. Carefully remove the cover from the sensor
3. Remove the plastic pull-tab from the battery slot. The LED indicator will blink slowly 5 times
4. Put your Z-Wave controller into inclusion mode
5. Press and release the Z-Wave button on the Water Sensor 3 TIMES quickly. The LED indicator
will flash quickly
6. A new water (leak) sensor will appear on your controller's device list
Troubleshooting Tips
If you are unable to include the Z-Wave Water Sensor to your controller, try one of the following:
- Bring the sensor closer to your hub or use a hand-held secondary controller to perform inclusion
- Once in inclusion mode, press and release the Z-Wave button quickly 6-7 TIMES to ensure the command
has gone through
- Put your controller in EXCLUSION mode. Press and release the Z-Wave button quickly 3 TIMES, and then
try adding the sensor to your network again
- You may need to change the device type manually if the sensor is not recognized correctly (email us for
more info: ask@getzooz.com)
Z-WAVE EXCLUSION
1. Make sure the Water Sensor is powered on and located within direct range of your Z-Wave gateway
controller
2. Put your Z-Wave controller in exclusion mode
3. Press and release the Z-Wave button 3 TIMES quickly. The LED indicator will flash quickly
4. The Water Sensor should disappear from your controller's device list
If the first attempt is unsuccessful, please repeat the process following all steps carefully.

FACTORY RESET
When your network’s primary controller is missing or otherwise inoperable, you may need to reset the
device to factory settings manually. To complete the process, make sure the Water Sensor is powered on,
then PRESS AND HOLD the Z-Wave button for AT LEAST 10 SECONDS until the LED indicator flashes ONCE.
Release the button. NOTE: All previously recorded activity and custom settings will be erased from the
device’s memory.
MOUNTING
There are 2 ways to install the Water Sensor:
1. Simply place the sensor on flat surface which you want to monitor for leaks. It can be the floor in your
laundry room or kitchen cabinet under the sink.
You don’t need to use the external probe or mounting bracket for this installation. This is great for spaces
where you expect dripping rather than flooding.
NOTE: Check that all 3 foot probes are touching the surface.
OR
2. Use the mounting bracket to install the sensor on a wall above the ground where you want to monitor
leaks or water level.
- Once you determine the perfect spot, fix the bracket to the wall with the supplied screw
- Place the sensor in the bracket fitting the foot probes into the round metal contacts
- Plug the external probe into the sensor and make sure it lays flat on the floor. Test the device
This installation is great for spaces which may get flooded, such as basements or boiler rooms.
WARNING
- This product should be installed indoors upon completion of any building renovations
- Prior to installation, the device should be stored in a dry, dust-and-mold-proof place
- Do not install the Water Sensor in a place with direct sun exposure, high temperature or humidity
- Keep away from water, chemicals, and dust
- Ensure the device is never close to any heat source or open flame to prevent fire
- No part of the device may be replaced or repaired by the user, except for battery change
Z-WAVE PLUS CERTIFIED
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices
from other manufacturers and/or other applications. All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the network.

ADVANCED SETTINGS
If your controller’s software allows for advanced configuration and parameter adjustment, you will be
able to change and save the settings below and customize the Water Sensor’s performance to serve your
needs.
Total Alarm Duration
Parameter 1: Use this parameter to set the total duration of audio and visual alarm each time water is
detected. If the value is set to 0, the alarm will continue until water is no longer detected. Use parameters
2 –4 to customize the alarm.
Values: 0 –255 (minutes). 120 –default setting.
Size: 1 byte dec.
Audio Alarm: Beep Interval
Parameter 2: Set the beeping frequency for the sensor’s audio alarm. The interval between beeps can be
as low as 1 minute.
Values: 1 –255 (minutes); 1 –default setting.
Size: 1 byte dec.
Audio Alarm: First Beep Duration
Parameter 3: Adjust the duration of the initial sound the alarm will produce after a leak is detected.
Values: 10 –255 (seconds); 60 –default setting.
Size: 1 byte dec.
Audio Alarm: Beep Duration
Parameter 4: Adjust the duration of the beeps the alarm will sound after a leak is detected and the first
“long” beep is produced.
Values: 5 –255 (seconds); 5 –default setting.
Size: 1 byte dec.
Enable / Disable Audio Alarm
Parameter 5: Enable or disable the audio alarm by adjusting these parameter settings. The visual alarm
will NOT be disabled and the LED indicator will always light up each time water is detected.
Values: 0 –alarm disabled; 1 –alarm enabled (default setting).
Size: 1 byte dec.

Enable / Disable Water Detection
Parameter 6: Enable or disable water detection for the sensor by adjusting these parameter settings.
Values: 0 –sensor disabled; 1 –sensor enabled (default setting).
Size: 1 byte dec.
Trigger Action
Parameter 7: You can choose if your Water Sensor turns an associated device on or off when sending the
basic set command. Use value 0 to turn the associated device OFF and value 255 to turn it ON. Adjust
brightness level for a Z-Wave dimmer (Multilevel switch) by putting in any value between 1 and 99.
Values: 0 –OFF; 1 –99 (% of light); 255 –ON (default).
Size: 1 byte dec.
WAKE-UP MODE
If you change settings and parameters for the sensor, you may need to wake it up manually for the
changes to be recorded. Press and release the Z-Wave button THREE TIMES to wake the device up. The
LED indicator will flash ONCE.
The sensor’s wake-up interval is set to 12 hours by default to save battery life. Though not recommended,
you can change the wake-up interval using your controller’s advanced settings if available. Minimum
value: 300s (5 minutes), maximum value: 16,777,200s (around 194 days). Accepted values need to match
minute intervals, so 300, 360, 420, etc.
ASSOCIATION
Depending on your Z-Wave gateway's home automation software capabilities, you may be able to
associate your Water Sensor in groups with other Z-Wave devices to schedule scenes and create events.
This Water Sensor supports the following association groups with up to five devices per group:
Group 1 for lifeline communication of water leak detection to Z-Wave controller. Supported command
classes:
NOTIFICATION_REPORT_V4
BATTERY_REPORT
SENSOR_BINARY_REPORT_V2
DEVICE_RESET_LOCALLY_NOTIFICATION
Group 2 for control command communication to associated Z-Wave devices in the network. Use
parameter 7 to configure this group’s settings. Supported command classes:
BASIC_SET
Group 3 for notifications to Z-Wave devices associated in this group. Supported command classes:
NOTIFICATION_REPORT_V4
Group 4 for notifications to Z-Wave devices associated in this group. Supported command classes:
SENSOR_BINARY_REPORT_V2
Table of contents