ZooZ ZSE40 User manual

USER MANUAL
Z-WAVE 4-IN-1 SENSOR
MOTION / LIGHT / TEMPERATURE / HUMIDITY
Z-Wave Plus Certified Device
FEATURES
- 4 smart sensors in 1 compact device
- 7 levels of motion sensitivity
- 4 modes for motion / temperature LED
indicator notifications
- Built-in tamper protection
- Low battery alerts
- Z-Wave Plus with improved 500 chip for
faster and safer wireless communication
- AES signal encryption (security-enabled
controller required for best performance)
SPECIFICATIONS
Model Number: ZSE40
Z-Wave Signal Frequency: 908.42 MHz
Power: 2 AAA batteries
Range: Up to 100 feet line of sight
Operating Temperature: 5° - 104° F
Installation and Use: Indoor only
In the box: 4-in-1 sensor, 2 AAA batteries,
mounting hardware
BEFORE YOU RETURN IT
Let us know if you are having any issues
installing or operating the device.
Our fast and friendly tech support is here to
help, every day of the year:
ask@getzooz.com
Get more helpful tips at getzooz.com
INSTALLATION
WAIT!
Include the 4-in-1 sensor to your Z-Wave
network before mounting it.
Use a paperclip for inclusion, exclusion,
factory reset, and manual wake-up.
Z-WAVE INCLUSION
1. Install batteries and bring the 4-in-1
sensor within direct range of your Z-Wave
gateway controller
2. Put your Z-Wave controller in inclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. A new 4-in-1 sensor should appear on your
controller's device list
Troubleshooting Tips
If you are unable to include the Z-Wave
sensor to your controller, please try one of
the following:
- Bring the 4-in-1 sensor closer to your Z-
Wave controller
- Press and release the Z-Wave button
quickly several times once you put the
controller in the inclusion mode to ensure
the command has gone through
- Put your controller in EXCLUSION mode
and press and release the Z-Wave button
TWICE quickly, then try adding it to your
network again
- Make sure you are clicking the Z-Wave
button located in the small opening on the
bottom of the sensor and NOT the tamper
switch located above the battery slot
Z-WAVE EXCLUSION
1. Bring the 4-in-1 sensor within direct range
of your Z-Wave gateway controller
2. Put your Z-Wave controller in exclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. The device should disappear from your
controller's device list.
The LED indicator will flash 3 times when you
take the batteries out and put them back in
to indicate the device has been successfully
excluded.
Please repeat the process following all steps
carefully if the LED indicator blinks only once
when you re-insert the batteries.
WAKE-UP MODE
If you change settings and parameters for
the sensor, you may need to wake it up
manually for the changes to be recorded.
Press and release the Z-Wave button ONCE
to wake the device up. The LED indicator will
flash ONCE.
The sensor’s wake-up interval is set to 12
hours by default to save battery life. Though
not recommended, you can change the
wake-up interval using your controller’s
advanced settings if available.
FACTORY RESET
If your primary controller is missing or
inoperable, you may need to reset the device
to factory settings. To complete the reset
process manually, remove the back cover to
trigger tamper switch. Press and release the
Z-Wave button 10 TIMES quickly (within 10
seconds) using a paperclip.
NOTE: All previously recorded activity and
custom settings will be erased from the
device’s memory.
MOUNTING
WAIT! This sensor may only be used and
installed indoors. Outdoor installation will
void its warranty.
For best results, mount the sensor within 30
feet from the door and around 7 feet from
the ground. The 4-in-1 Sensor will detect
motion up to 40 feet depending on
mounting location and sensitivity settings.
There are 2 ways to mount the 4-in-1 Sensor
on the wall, ceiling, or in the corner of a room:
1. Use the 2 screws included in the box to fix
the mounting bracket to flat surface of your
choice - at least 7 feet above the ground for
best results.
Once the bracket is securely installed,
carefully slide the 4-in-1 sensor onto the
bracket and position it by tilting it to either
side, upwards, or downwards - just like in the
images below.
OR
2. Use the supplied adhesive tape to fix the
sensor to a CLEAN flat surface of your choice.
Make sure you apply the tape according to
below instructions.
ASSOCIATION
Certified Z-Wave products from different
manufacturers and product categories can
be a part of the same Z-Wave network. Non-
battery powered nodes can act as signal
repeaters to other devices in the network
regardless of manufacturer or brand.
ZSE40
tamper switch
AAA batteries
corner installation
ceiling installation
wall installation
40 feet
7 feet
20 feet
16 feet
7 feet
40 feet
Z-Wave button
light sensor
23 4 5 6 789

USER MANUAL
Z-WAVE 4-IN-1 SENSOR
MOTION / LIGHT / TEMPERATURE / HUMIDITY
Z-Wave Plus Certified Device
FEATURES
- 4 smart sensors in 1 compact device
- 7 levels of motion sensitivity
- 4 modes for motion / temperature LED
indicator notifications
- Built-in tamper protection
- Low battery alerts
- Z-Wave Plus with improved 500 chip for
faster and safer wireless communication
- AES signal encryption (security-enabled
controller required for best performance)
SPECIFICATIONS
Model Number: ZSE40
Z-Wave Signal Frequency: 908.42 MHz
Power: 2 AAA batteries
Range: Up to 100 feet line of sight
Operating Temperature: 5° - 104° F
Installation and Use: Indoor only
In the box: 4-in-1 sensor, 2 AAA batteries,
mounting hardware
BEFORE YOU RETURN IT
Let us know if you are having any issues
installing or operating the device.
Our fast and friendly tech support is here to
help, every day of the year:
ask@getzooz.com
Get more helpful tips at getzooz.com
INSTALLATION
WAIT!
Include the 4-in-1 sensor to your Z-Wave
network before mounting it.
Use a paperclip for inclusion, exclusion,
factory reset, and manual wake-up.
Z-WAVE INCLUSION
1. Install batteries and bring the 4-in-1
sensor within direct range of your Z-Wave
gateway controller
2. Put your Z-Wave controller in inclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. A new 4-in-1 sensor should appear on your
controller's device list
Troubleshooting Tips
If you are unable to include the Z-Wave
sensor to your controller, please try one of
the following:
- Bring the 4-in-1 sensor closer to your Z-
Wave controller
- Press and release the Z-Wave button
quickly several times once you put the
controller in the inclusion mode to ensure
the command has gone through
- Put your controller in EXCLUSION mode
and press and release the Z-Wave button
TWICE quickly, then try adding it to your
network again
- Make sure you are clicking the Z-Wave
button located in the small opening on the
bottom of the sensor and NOT the tamper
switch located above the battery slot
Z-WAVE EXCLUSION
1. Bring the 4-in-1 sensor within direct range
of your Z-Wave gateway controller
2. Put your Z-Wave controller in exclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. The device should disappear from your
controller's device list.
The LED indicator will flash 3 times when you
take the batteries out and put them back in
to indicate the device has been successfully
excluded.
Please repeat the process following all steps
carefully if the LED indicator blinks only once
when you re-insert the batteries.
WAKE-UP MODE
If you change settings and parameters for
the sensor, you may need to wake it up
manually for the changes to be recorded.
Press and release the Z-Wave button ONCE
to wake the device up. The LED indicator will
flash ONCE.
The sensor’s wake-up interval is set to 12
hours by default to save battery life. Though
not recommended, you can change the
wake-up interval using your controller’s
advanced settings if available.
FACTORY RESET
If your primary controller is missing or
inoperable, you may need to reset the device
to factory settings. To complete the reset
process manually, remove the back cover to
trigger tamper switch. Press and release the
Z-Wave button 10 TIMES quickly (within 10
seconds) using a paperclip.
NOTE: All previously recorded activity and
custom settings will be erased from the
device’s memory.
MOUNTING
WAIT! This sensor may only be used and
installed indoors. Outdoor installation will
void its warranty.
For best results, mount the sensor within 30
feet from the door and around 7 feet from
the ground. The 4-in-1 Sensor will detect
motion up to 40 feet depending on
mounting location and sensitivity settings.
There are 2 ways to mount the 4-in-1 Sensor
on the wall, ceiling, or in the corner of a room:
1. Use the 2 screws included in the box to fix
the mounting bracket to flat surface of your
choice - at least 7 feet above the ground for
best results.
Once the bracket is securely installed,
carefully slide the 4-in-1 sensor onto the
bracket and position it by tilting it to either
side, upwards, or downwards - just like in the
images below.
OR
2. Use the supplied adhesive tape to fix the
sensor to a CLEAN flat surface of your choice.
Make sure you apply the tape according to
below instructions.
ASSOCIATION
Certified Z-Wave products from different
manufacturers and product categories can
be a part of the same Z-Wave network. Non-
battery powered nodes can act as signal
repeaters to other devices in the network
regardless of manufacturer or brand.
ZSE40
tamper switch
AAA batteries
corner installation
ceiling installation
wall installation
40 feet
7 feet
20 feet
16 feet
7 feet
40 feet
Z-Wave button
light sensor
23 4 5 6 789

USER MANUAL
Z-WAVE 4-IN-1 SENSOR
MOTION / LIGHT / TEMPERATURE / HUMIDITY
Z-Wave Plus Certified Device
FEATURES
- 4 smart sensors in 1 compact device
- 7 levels of motion sensitivity
- 4 modes for motion / temperature LED
indicator notifications
- Built-in tamper protection
- Low battery alerts
- Z-Wave Plus with improved 500 chip for
faster and safer wireless communication
- AES signal encryption (security-enabled
controller required for best performance)
SPECIFICATIONS
Model Number: ZSE40
Z-Wave Signal Frequency: 908.42 MHz
Power: 2 AAA batteries
Range: Up to 100 feet line of sight
Operating Temperature: 5° - 104° F
Installation and Use: Indoor only
In the box: 4-in-1 sensor, 2 AAA batteries,
mounting hardware
BEFORE YOU RETURN IT
Let us know if you are having any issues
installing or operating the device.
Our fast and friendly tech support is here to
help, every day of the year:
ask@getzooz.com
Get more helpful tips at getzooz.com
INSTALLATION
WAIT!
Include the 4-in-1 sensor to your Z-Wave
network before mounting it.
Use a paperclip for inclusion, exclusion,
factory reset, and manual wake-up.
Z-WAVE INCLUSION
1. Install batteries and bring the 4-in-1
sensor within direct range of your Z-Wave
gateway controller
2. Put your Z-Wave controller in inclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. A new 4-in-1 sensor should appear on your
controller's device list
Troubleshooting Tips
If you are unable to include the Z-Wave
sensor to your controller, please try one of
the following:
- Bring the 4-in-1 sensor closer to your Z-
Wave controller
- Press and release the Z-Wave button
quickly several times once you put the
controller in the inclusion mode to ensure
the command has gone through
- Put your controller in EXCLUSION mode
and press and release the Z-Wave button
TWICE quickly, then try adding it to your
network again
- Make sure you are clicking the Z-Wave
button located in the small opening on the
bottom of the sensor and NOT the tamper
switch located above the battery slot
Z-WAVE EXCLUSION
1. Bring the 4-in-1 sensor within direct range
of your Z-Wave gateway controller
2. Put your Z-Wave controller in exclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. The device should disappear from your
controller's device list.
The LED indicator will flash 3 times when you
take the batteries out and put them back in
to indicate the device has been successfully
excluded.
Please repeat the process following all steps
carefully if the LED indicator blinks only once
when you re-insert the batteries.
WAKE-UP MODE
If you change settings and parameters for
the sensor, you may need to wake it up
manually for the changes to be recorded.
Press and release the Z-Wave button ONCE
to wake the device up. The LED indicator will
flash ONCE.
The sensor’s wake-up interval is set to 12
hours by default to save battery life. Though
not recommended, you can change the
wake-up interval using your controller’s
advanced settings if available.
FACTORY RESET
If your primary controller is missing or
inoperable, you may need to reset the device
to factory settings. To complete the reset
process manually, remove the back cover to
trigger tamper switch. Press and release the
Z-Wave button 10 TIMES quickly (within 10
seconds) using a paperclip.
NOTE: All previously recorded activity and
custom settings will be erased from the
device’s memory.
MOUNTING
WAIT! This sensor may only be used and
installed indoors. Outdoor installation will
void its warranty.
For best results, mount the sensor within 30
feet from the door and around 7 feet from
the ground. The 4-in-1 Sensor will detect
motion up to 40 feet depending on
mounting location and sensitivity settings.
There are 2 ways to mount the 4-in-1 Sensor
on the wall, ceiling, or in the corner of a room:
1. Use the 2 screws included in the box to fix
the mounting bracket to flat surface of your
choice - at least 7 feet above the ground for
best results.
Once the bracket is securely installed,
carefully slide the 4-in-1 sensor onto the
bracket and position it by tilting it to either
side, upwards, or downwards - just like in the
images below.
OR
2. Use the supplied adhesive tape to fix the
sensor to a CLEAN flat surface of your choice.
Make sure you apply the tape according to
below instructions.
ASSOCIATION
Certified Z-Wave products from different
manufacturers and product categories can
be a part of the same Z-Wave network. Non-
battery powered nodes can act as signal
repeaters to other devices in the network
regardless of manufacturer or brand.
ZSE40
tamper switch
AAA batteries
corner installation
ceiling installation
wall installation
40 feet
7 feet
20 feet
16 feet
7 feet
40 feet
Z-Wave button
light sensor
23 4 5 6 789

USER MANUAL
Z-WAVE 4-IN-1 SENSOR
MOTION / LIGHT / TEMPERATURE / HUMIDITY
Z-Wave Plus Certified Device
FEATURES
- 4 smart sensors in 1 compact device
- 7 levels of motion sensitivity
- 4 modes for motion / temperature LED
indicator notifications
- Built-in tamper protection
- Low battery alerts
- Z-Wave Plus with improved 500 chip for
faster and safer wireless communication
- AES signal encryption (security-enabled
controller required for best performance)
SPECIFICATIONS
Model Number: ZSE40
Z-Wave Signal Frequency: 908.42 MHz
Power: 2 AAA batteries
Range: Up to 100 feet line of sight
Operating Temperature: 5° - 104° F
Installation and Use: Indoor only
In the box: 4-in-1 sensor, 2 AAA batteries,
mounting hardware
BEFORE YOU RETURN IT
Let us know if you are having any issues
installing or operating the device.
Our fast and friendly tech support is here to
help, every day of the year:
ask@getzooz.com
Get more helpful tips at getzooz.com
INSTALLATION
WAIT!
Include the 4-in-1 sensor to your Z-Wave
network before mounting it.
Use a paperclip for inclusion, exclusion,
factory reset, and manual wake-up.
Z-WAVE INCLUSION
1. Install batteries and bring the 4-in-1
sensor within direct range of your Z-Wave
gateway controller
2. Put your Z-Wave controller in inclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. A new 4-in-1 sensor should appear on your
controller's device list
Troubleshooting Tips
If you are unable to include the Z-Wave
sensor to your controller, please try one of
the following:
- Bring the 4-in-1 sensor closer to your Z-
Wave controller
- Press and release the Z-Wave button
quickly several times once you put the
controller in the inclusion mode to ensure
the command has gone through
- Put your controller in EXCLUSION mode
and press and release the Z-Wave button
TWICE quickly, then try adding it to your
network again
- Make sure you are clicking the Z-Wave
button located in the small opening on the
bottom of the sensor and NOT the tamper
switch located above the battery slot
Z-WAVE EXCLUSION
1. Bring the 4-in-1 sensor within direct range
of your Z-Wave gateway controller
2. Put your Z-Wave controller in exclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. The device should disappear from your
controller's device list.
The LED indicator will flash 3 times when you
take the batteries out and put them back in
to indicate the device has been successfully
excluded.
Please repeat the process following all steps
carefully if the LED indicator blinks only once
when you re-insert the batteries.
WAKE-UP MODE
If you change settings and parameters for
the sensor, you may need to wake it up
manually for the changes to be recorded.
Press and release the Z-Wave button ONCE
to wake the device up. The LED indicator will
flash ONCE.
The sensor’s wake-up interval is set to 12
hours by default to save battery life. Though
not recommended, you can change the
wake-up interval using your controller’s
advanced settings if available.
FACTORY RESET
If your primary controller is missing or
inoperable, you may need to reset the device
to factory settings. To complete the reset
process manually, remove the back cover to
trigger tamper switch. Press and release the
Z-Wave button 10 TIMES quickly (within 10
seconds) using a paperclip.
NOTE: All previously recorded activity and
custom settings will be erased from the
device’s memory.
MOUNTING
WAIT! This sensor may only be used and
installed indoors. Outdoor installation will
void its warranty.
For best results, mount the sensor within 30
feet from the door and around 7 feet from
the ground. The 4-in-1 Sensor will detect
motion up to 40 feet depending on
mounting location and sensitivity settings.
There are 2 ways to mount the 4-in-1 Sensor
on the wall, ceiling, or in the corner of a room:
1. Use the 2 screws included in the box to fix
the mounting bracket to flat surface of your
choice - at least 7 feet above the ground for
best results.
Once the bracket is securely installed,
carefully slide the 4-in-1 sensor onto the
bracket and position it by tilting it to either
side, upwards, or downwards - just like in the
images below.
OR
2. Use the supplied adhesive tape to fix the
sensor to a CLEAN flat surface of your choice.
Make sure you apply the tape according to
below instructions.
ASSOCIATION
Certified Z-Wave products from different
manufacturers and product categories can
be a part of the same Z-Wave network. Non-
battery powered nodes can act as signal
repeaters to other devices in the network
regardless of manufacturer or brand.
ZSE40
tamper switch
AAA batteries
corner installation
ceiling installation
wall installation
40 feet
7 feet
20 feet
16 feet
7 feet
40 feet
Z-Wave button
light sensor
23 4 5 6 789

USER MANUAL
Z-WAVE 4-IN-1 SENSOR
MOTION / LIGHT / TEMPERATURE / HUMIDITY
Z-Wave Plus Certified Device
FEATURES
- 4 smart sensors in 1 compact device
- 7 levels of motion sensitivity
- 4 modes for motion / temperature LED
indicator notifications
- Built-in tamper protection
- Low battery alerts
- Z-Wave Plus with improved 500 chip for
faster and safer wireless communication
- AES signal encryption (security-enabled
controller required for best performance)
SPECIFICATIONS
Model Number: ZSE40
Z-Wave Signal Frequency: 908.42 MHz
Power: 2 AAA batteries
Range: Up to 100 feet line of sight
Operating Temperature: 5° - 104° F
Installation and Use: Indoor only
In the box: 4-in-1 sensor, 2 AAA batteries,
mounting hardware
BEFORE YOU RETURN IT
Let us know if you are having any issues
installing or operating the device.
Our fast and friendly tech support is here to
help, every day of the year:
ask@getzooz.com
Get more helpful tips at getzooz.com
INSTALLATION
WAIT!
Include the 4-in-1 sensor to your Z-Wave
network before mounting it.
Use a paperclip for inclusion, exclusion,
factory reset, and manual wake-up.
Z-WAVE INCLUSION
1. Install batteries and bring the 4-in-1
sensor within direct range of your Z-Wave
gateway controller
2. Put your Z-Wave controller in inclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. A new 4-in-1 sensor should appear on your
controller's device list
Troubleshooting Tips
If you are unable to include the Z-Wave
sensor to your controller, please try one of
the following:
- Bring the 4-in-1 sensor closer to your Z-
Wave controller
- Press and release the Z-Wave button
quickly several times once you put the
controller in the inclusion mode to ensure
the command has gone through
- Put your controller in EXCLUSION mode
and press and release the Z-Wave button
TWICE quickly, then try adding it to your
network again
- Make sure you are clicking the Z-Wave
button located in the small opening on the
bottom of the sensor and NOT the tamper
switch located above the battery slot
Z-WAVE EXCLUSION
1. Bring the 4-in-1 sensor within direct range
of your Z-Wave gateway controller
2. Put your Z-Wave controller in exclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. The device should disappear from your
controller's device list.
The LED indicator will flash 3 times when you
take the batteries out and put them back in
to indicate the device has been successfully
excluded.
Please repeat the process following all steps
carefully if the LED indicator blinks only once
when you re-insert the batteries.
WAKE-UP MODE
If you change settings and parameters for
the sensor, you may need to wake it up
manually for the changes to be recorded.
Press and release the Z-Wave button ONCE
to wake the device up. The LED indicator will
flash ONCE.
The sensor’s wake-up interval is set to 12
hours by default to save battery life. Though
not recommended, you can change the
wake-up interval using your controller’s
advanced settings if available.
FACTORY RESET
If your primary controller is missing or
inoperable, you may need to reset the device
to factory settings. To complete the reset
process manually, remove the back cover to
trigger tamper switch. Press and release the
Z-Wave button 10 TIMES quickly (within 10
seconds) using a paperclip.
NOTE: All previously recorded activity and
custom settings will be erased from the
device’s memory.
MOUNTING
WAIT! This sensor may only be used and
installed indoors. Outdoor installation will
void its warranty.
For best results, mount the sensor within 30
feet from the door and around 7 feet from
the ground. The 4-in-1 Sensor will detect
motion up to 40 feet depending on
mounting location and sensitivity settings.
There are 2 ways to mount the 4-in-1 Sensor
on the wall, ceiling, or in the corner of a room:
1. Use the 2 screws included in the box to fix
the mounting bracket to flat surface of your
choice - at least 7 feet above the ground for
best results.
Once the bracket is securely installed,
carefully slide the 4-in-1 sensor onto the
bracket and position it by tilting it to either
side, upwards, or downwards - just like in the
images below.
OR
2. Use the supplied adhesive tape to fix the
sensor to a CLEAN flat surface of your choice.
Make sure you apply the tape according to
below instructions.
ASSOCIATION
Certified Z-Wave products from different
manufacturers and product categories can
be a part of the same Z-Wave network. Non-
battery powered nodes can act as signal
repeaters to other devices in the network
regardless of manufacturer or brand.
ZSE40
tamper switch
AAA batteries
corner installation
ceiling installation
wall installation
40 feet
7 feet
20 feet
16 feet
7 feet
40 feet
Z-Wave button
light sensor
23 4 5 6 789

USER MANUAL
Z-WAVE 4-IN-1 SENSOR
MOTION / LIGHT / TEMPERATURE / HUMIDITY
Z-Wave Plus Certified Device
FEATURES
- 4 smart sensors in 1 compact device
- 7 levels of motion sensitivity
- 4 modes for motion / temperature LED
indicator notifications
- Built-in tamper protection
- Low battery alerts
- Z-Wave Plus with improved 500 chip for
faster and safer wireless communication
- AES signal encryption (security-enabled
controller required for best performance)
SPECIFICATIONS
Model Number: ZSE40
Z-Wave Signal Frequency: 908.42 MHz
Power: 2 AAA batteries
Range: Up to 100 feet line of sight
Operating Temperature: 5° - 104° F
Installation and Use: Indoor only
In the box: 4-in-1 sensor, 2 AAA batteries,
mounting hardware
BEFORE YOU RETURN IT
Let us know if you are having any issues
installing or operating the device.
Our fast and friendly tech support is here to
help, every day of the year:
ask@getzooz.com
Get more helpful tips at getzooz.com
INSTALLATION
WAIT!
Include the 4-in-1 sensor to your Z-Wave
network before mounting it.
Use a paperclip for inclusion, exclusion,
factory reset, and manual wake-up.
Z-WAVE INCLUSION
1. Install batteries and bring the 4-in-1
sensor within direct range of your Z-Wave
gateway controller
2. Put your Z-Wave controller in inclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. A new 4-in-1 sensor should appear on your
controller's device list
Troubleshooting Tips
If you are unable to include the Z-Wave
sensor to your controller, please try one of
the following:
- Bring the 4-in-1 sensor closer to your Z-
Wave controller
- Press and release the Z-Wave button
quickly several times once you put the
controller in the inclusion mode to ensure
the command has gone through
- Put your controller in EXCLUSION mode
and press and release the Z-Wave button
TWICE quickly, then try adding it to your
network again
- Make sure you are clicking the Z-Wave
button located in the small opening on the
bottom of the sensor and NOT the tamper
switch located above the battery slot
Z-WAVE EXCLUSION
1. Bring the 4-in-1 sensor within direct range
of your Z-Wave gateway controller
2. Put your Z-Wave controller in exclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. The device should disappear from your
controller's device list.
The LED indicator will flash 3 times when you
take the batteries out and put them back in
to indicate the device has been successfully
excluded.
Please repeat the process following all steps
carefully if the LED indicator blinks only once
when you re-insert the batteries.
WAKE-UP MODE
If you change settings and parameters for
the sensor, you may need to wake it up
manually for the changes to be recorded.
Press and release the Z-Wave button ONCE
to wake the device up. The LED indicator will
flash ONCE.
The sensor’s wake-up interval is set to 12
hours by default to save battery life. Though
not recommended, you can change the
wake-up interval using your controller’s
advanced settings if available.
FACTORY RESET
If your primary controller is missing or
inoperable, you may need to reset the device
to factory settings. To complete the reset
process manually, remove the back cover to
trigger tamper switch. Press and release the
Z-Wave button 10 TIMES quickly (within 10
seconds) using a paperclip.
NOTE: All previously recorded activity and
custom settings will be erased from the
device’s memory.
MOUNTING
WAIT! This sensor may only be used and
installed indoors. Outdoor installation will
void its warranty.
For best results, mount the sensor within 30
feet from the door and around 7 feet from
the ground. The 4-in-1 Sensor will detect
motion up to 40 feet depending on
mounting location and sensitivity settings.
There are 2 ways to mount the 4-in-1 Sensor
on the wall, ceiling, or in the corner of a room:
1. Use the 2 screws included in the box to fix
the mounting bracket to flat surface of your
choice - at least 7 feet above the ground for
best results.
Once the bracket is securely installed,
carefully slide the 4-in-1 sensor onto the
bracket and position it by tilting it to either
side, upwards, or downwards - just like in the
images below.
OR
2. Use the supplied adhesive tape to fix the
sensor to a CLEAN flat surface of your choice.
Make sure you apply the tape according to
below instructions.
ASSOCIATION
Certified Z-Wave products from different
manufacturers and product categories can
be a part of the same Z-Wave network. Non-
battery powered nodes can act as signal
repeaters to other devices in the network
regardless of manufacturer or brand.
ZSE40
tamper switch
AAA batteries
corner installation
ceiling installation
wall installation
40 feet
7 feet
20 feet
16 feet
7 feet
40 feet
Z-Wave button
light sensor
23 4 5 6 789

USER MANUAL
Z-WAVE 4-IN-1 SENSOR
MOTION / LIGHT / TEMPERATURE / HUMIDITY
Z-Wave Plus Certified Device
FEATURES
- 4 smart sensors in 1 compact device
- 7 levels of motion sensitivity
- 4 modes for motion / temperature LED
indicator notifications
- Built-in tamper protection
- Low battery alerts
- Z-Wave Plus with improved 500 chip for
faster and safer wireless communication
- AES signal encryption (security-enabled
controller required for best performance)
SPECIFICATIONS
Model Number: ZSE40
Z-Wave Signal Frequency: 908.42 MHz
Power: 2 AAA batteries
Range: Up to 100 feet line of sight
Operating Temperature: 5° - 104° F
Installation and Use: Indoor only
In the box: 4-in-1 sensor, 2 AAA batteries,
mounting hardware
BEFORE YOU RETURN IT
Let us know if you are having any issues
installing or operating the device.
Our fast and friendly tech support is here to
help, every day of the year:
ask@getzooz.com
Get more helpful tips at getzooz.com
INSTALLATION
WAIT!
Include the 4-in-1 sensor to your Z-Wave
network before mounting it.
Use a paperclip for inclusion, exclusion,
factory reset, and manual wake-up.
Z-WAVE INCLUSION
1. Install batteries and bring the 4-in-1
sensor within direct range of your Z-Wave
gateway controller
2. Put your Z-Wave controller in inclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. A new 4-in-1 sensor should appear on your
controller's device list
Troubleshooting Tips
If you are unable to include the Z-Wave
sensor to your controller, please try one of
the following:
- Bring the 4-in-1 sensor closer to your Z-
Wave controller
- Press and release the Z-Wave button
quickly several times once you put the
controller in the inclusion mode to ensure
the command has gone through
- Put your controller in EXCLUSION mode
and press and release the Z-Wave button
TWICE quickly, then try adding it to your
network again
- Make sure you are clicking the Z-Wave
button located in the small opening on the
bottom of the sensor and NOT the tamper
switch located above the battery slot
Z-WAVE EXCLUSION
1. Bring the 4-in-1 sensor within direct range
of your Z-Wave gateway controller
2. Put your Z-Wave controller in exclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. The device should disappear from your
controller's device list.
The LED indicator will flash 3 times when you
take the batteries out and put them back in
to indicate the device has been successfully
excluded.
Please repeat the process following all steps
carefully if the LED indicator blinks only once
when you re-insert the batteries.
WAKE-UP MODE
If you change settings and parameters for
the sensor, you may need to wake it up
manually for the changes to be recorded.
Press and release the Z-Wave button ONCE
to wake the device up. The LED indicator will
flash ONCE.
The sensor’s wake-up interval is set to 12
hours by default to save battery life. Though
not recommended, you can change the
wake-up interval using your controller’s
advanced settings if available.
FACTORY RESET
If your primary controller is missing or
inoperable, you may need to reset the device
to factory settings. To complete the reset
process manually, remove the back cover to
trigger tamper switch. Press and release the
Z-Wave button 10 TIMES quickly (within 10
seconds) using a paperclip.
NOTE: All previously recorded activity and
custom settings will be erased from the
device’s memory.
MOUNTING
WAIT! This sensor may only be used and
installed indoors. Outdoor installation will
void its warranty.
For best results, mount the sensor within 30
feet from the door and around 7 feet from
the ground. The 4-in-1 Sensor will detect
motion up to 40 feet depending on
mounting location and sensitivity settings.
There are 2 ways to mount the 4-in-1 Sensor
on the wall, ceiling, or in the corner of a room:
1. Use the 2 screws included in the box to fix
the mounting bracket to flat surface of your
choice - at least 7 feet above the ground for
best results.
Once the bracket is securely installed,
carefully slide the 4-in-1 sensor onto the
bracket and position it by tilting it to either
side, upwards, or downwards - just like in the
images below.
OR
2. Use the supplied adhesive tape to fix the
sensor to a CLEAN flat surface of your choice.
Make sure you apply the tape according to
below instructions.
ASSOCIATION
Certified Z-Wave products from different
manufacturers and product categories can
be a part of the same Z-Wave network. Non-
battery powered nodes can act as signal
repeaters to other devices in the network
regardless of manufacturer or brand.
ZSE40
tamper switch
AAA batteries
corner installation
ceiling installation
wall installation
40 feet
7 feet
20 feet
16 feet
7 feet
40 feet
Z-Wave button
light sensor
23 4 5 6 789

USER MANUAL
Z-WAVE 4-IN-1 SENSOR
MOTION / LIGHT / TEMPERATURE / HUMIDITY
Z-Wave Plus Certified Device
FEATURES
- 4 smart sensors in 1 compact device
- 7 levels of motion sensitivity
- 4 modes for motion / temperature LED
indicator notifications
- Built-in tamper protection
- Low battery alerts
- Z-Wave Plus with improved 500 chip for
faster and safer wireless communication
- AES signal encryption (security-enabled
controller required for best performance)
SPECIFICATIONS
Model Number: ZSE40
Z-Wave Signal Frequency: 908.42 MHz
Power: 2 AAA batteries
Range: Up to 100 feet line of sight
Operating Temperature: 5° - 104° F
Installation and Use: Indoor only
In the box: 4-in-1 sensor, 2 AAA batteries,
mounting hardware
BEFORE YOU RETURN IT
Let us know if you are having any issues
installing or operating the device.
Our fast and friendly tech support is here to
help, every day of the year:
ask@getzooz.com
Get more helpful tips at getzooz.com
INSTALLATION
WAIT!
Include the 4-in-1 sensor to your Z-Wave
network before mounting it.
Use a paperclip for inclusion, exclusion,
factory reset, and manual wake-up.
Z-WAVE INCLUSION
1. Install batteries and bring the 4-in-1
sensor within direct range of your Z-Wave
gateway controller
2. Put your Z-Wave controller in inclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. A new 4-in-1 sensor should appear on your
controller's device list
Troubleshooting Tips
If you are unable to include the Z-Wave
sensor to your controller, please try one of
the following:
- Bring the 4-in-1 sensor closer to your Z-
Wave controller
- Press and release the Z-Wave button
quickly several times once you put the
controller in the inclusion mode to ensure
the command has gone through
- Put your controller in EXCLUSION mode
and press and release the Z-Wave button
TWICE quickly, then try adding it to your
network again
- Make sure you are clicking the Z-Wave
button located in the small opening on the
bottom of the sensor and NOT the tamper
switch located above the battery slot
Z-WAVE EXCLUSION
1. Bring the 4-in-1 sensor within direct range
of your Z-Wave gateway controller
2. Put your Z-Wave controller in exclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. The device should disappear from your
controller's device list.
The LED indicator will flash 3 times when you
take the batteries out and put them back in
to indicate the device has been successfully
excluded.
Please repeat the process following all steps
carefully if the LED indicator blinks only once
when you re-insert the batteries.
WAKE-UP MODE
If you change settings and parameters for
the sensor, you may need to wake it up
manually for the changes to be recorded.
Press and release the Z-Wave button ONCE
to wake the device up. The LED indicator will
flash ONCE.
The sensor’s wake-up interval is set to 12
hours by default to save battery life. Though
not recommended, you can change the
wake-up interval using your controller’s
advanced settings if available.
FACTORY RESET
If your primary controller is missing or
inoperable, you may need to reset the device
to factory settings. To complete the reset
process manually, remove the back cover to
trigger tamper switch. Press and release the
Z-Wave button 10 TIMES quickly (within 10
seconds) using a paperclip.
NOTE: All previously recorded activity and
custom settings will be erased from the
device’s memory.
MOUNTING
WAIT! This sensor may only be used and
installed indoors. Outdoor installation will
void its warranty.
For best results, mount the sensor within 30
feet from the door and around 7 feet from
the ground. The 4-in-1 Sensor will detect
motion up to 40 feet depending on
mounting location and sensitivity settings.
There are 2 ways to mount the 4-in-1 Sensor
on the wall, ceiling, or in the corner of a room:
1. Use the 2 screws included in the box to fix
the mounting bracket to flat surface of your
choice - at least 7 feet above the ground for
best results.
Once the bracket is securely installed,
carefully slide the 4-in-1 sensor onto the
bracket and position it by tilting it to either
side, upwards, or downwards - just like in the
images below.
OR
2. Use the supplied adhesive tape to fix the
sensor to a CLEAN flat surface of your choice.
Make sure you apply the tape according to
below instructions.
ASSOCIATION
Certified Z-Wave products from different
manufacturers and product categories can
be a part of the same Z-Wave network. Non-
battery powered nodes can act as signal
repeaters to other devices in the network
regardless of manufacturer or brand.
ZSE40
tamper switch
AAA batteries
corner installation
ceiling installation
wall installation
40 feet
7 feet
20 feet
16 feet
7 feet
40 feet
Z-Wave button
light sensor
23 4 5 6 789

USER MANUAL
Z-WAVE 4-IN-1 SENSOR
MOTION / LIGHT / TEMPERATURE / HUMIDITY
Z-Wave Plus Certified Device
FEATURES
- 4 smart sensors in 1 compact device
- 7 levels of motion sensitivity
- 4 modes for motion / temperature LED
indicator notifications
- Built-in tamper protection
- Low battery alerts
- Z-Wave Plus with improved 500 chip for
faster and safer wireless communication
- AES signal encryption (security-enabled
controller required for best performance)
SPECIFICATIONS
Model Number: ZSE40
Z-Wave Signal Frequency: 908.42 MHz
Power: 2 AAA batteries
Range: Up to 100 feet line of sight
Operating Temperature: 5° - 104° F
Installation and Use: Indoor only
In the box: 4-in-1 sensor, 2 AAA batteries,
mounting hardware
BEFORE YOU RETURN IT
Let us know if you are having any issues
installing or operating the device.
Our fast and friendly tech support is here to
help, every day of the year:
ask@getzooz.com
Get more helpful tips at getzooz.com
INSTALLATION
WAIT!
Include the 4-in-1 sensor to your Z-Wave
network before mounting it.
Use a paperclip for inclusion, exclusion,
factory reset, and manual wake-up.
Z-WAVE INCLUSION
1. Install batteries and bring the 4-in-1
sensor within direct range of your Z-Wave
gateway controller
2. Put your Z-Wave controller in inclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. A new 4-in-1 sensor should appear on your
controller's device list
Troubleshooting Tips
If you are unable to include the Z-Wave
sensor to your controller, please try one of
the following:
- Bring the 4-in-1 sensor closer to your Z-
Wave controller
- Press and release the Z-Wave button
quickly several times once you put the
controller in the inclusion mode to ensure
the command has gone through
- Put your controller in EXCLUSION mode
and press and release the Z-Wave button
TWICE quickly, then try adding it to your
network again
- Make sure you are clicking the Z-Wave
button located in the small opening on the
bottom of the sensor and NOT the tamper
switch located above the battery slot
Z-WAVE EXCLUSION
1. Bring the 4-in-1 sensor within direct range
of your Z-Wave gateway controller
2. Put your Z-Wave controller in exclusion
mode
3. Press and release the Z-Wave button
TWICE quickly
4. The device should disappear from your
controller's device list.
The LED indicator will flash 3 times when you
take the batteries out and put them back in
to indicate the device has been successfully
excluded.
Please repeat the process following all steps
carefully if the LED indicator blinks only once
when you re-insert the batteries.
WAKE-UP MODE
If you change settings and parameters for
the sensor, you may need to wake it up
manually for the changes to be recorded.
Press and release the Z-Wave button ONCE
to wake the device up. The LED indicator will
flash ONCE.
The sensor’s wake-up interval is set to 12
hours by default to save battery life. Though
not recommended, you can change the
wake-up interval using your controller’s
advanced settings if available.
FACTORY RESET
If your primary controller is missing or
inoperable, you may need to reset the device
to factory settings. To complete the reset
process manually, remove the back cover to
trigger tamper switch. Press and release the
Z-Wave button 10 TIMES quickly (within 10
seconds) using a paperclip.
NOTE: All previously recorded activity and
custom settings will be erased from the
device’s memory.
MOUNTING
WAIT! This sensor may only be used and
installed indoors. Outdoor installation will
void its warranty.
For best results, mount the sensor within 30
feet from the door and around 7 feet from
the ground. The 4-in-1 Sensor will detect
motion up to 40 feet depending on
mounting location and sensitivity settings.
There are 2 ways to mount the 4-in-1 Sensor
on the wall, ceiling, or in the corner of a room:
1. Use the 2 screws included in the box to fix
the mounting bracket to flat surface of your
choice - at least 7 feet above the ground for
best results.
Once the bracket is securely installed,
carefully slide the 4-in-1 sensor onto the
bracket and position it by tilting it to either
side, upwards, or downwards - just like in the
images below.
OR
2. Use the supplied adhesive tape to fix the
sensor to a CLEAN flat surface of your choice.
Make sure you apply the tape according to
below instructions.
ASSOCIATION
Certified Z-Wave products from different
manufacturers and product categories can
be a part of the same Z-Wave network. Non-
battery powered nodes can act as signal
repeaters to other devices in the network
regardless of manufacturer or brand.
ZSE40
tamper switch
AAA batteries
corner installation
ceiling installation
wall installation
40 feet
7 feet
20 feet
16 feet
7 feet
40 feet
Z-Wave button
light sensor
23 4 5 6 789

Depending on your Z-Wave gateway's home
automation software capabilities, you may
be able to associate your Z-Wave 4-in-1
sensor in groups with other Z-Wave devices
to schedule scenes and create events.
Zooz 4-in-1 sensor supports Group 1 with up
to five devices for lifeline communication. To
associate the sensor with other devices,
simply put your Z-Wave controller in
Association mode by sending the
appropriate command and put the 4-in-1
sensor in wake-up mode by pressing and
releasing its Z-Wave button.
ADVANCED SETTINGS
Once the 4-in-1 sensor is added to your Z-
Wave network, you are able to monitor the
values reported by the device on your
computer or mobile device.
Please refer to your controller's user guide
for advanced programming instructions as
they are a little different for every software.
Temperature Sensor
Parameter 1: Use this parameter to switch
from Fahrenheit to Celsius scale.
Values: 0 – Celsius. 1 – Fahrenheit (default).
Size: 1 byte dec.
Parameter 2: Use it to set temperature
change to be reported by the sensor.
Values: 1 - 50 (where 1 stands for 0.1 degree
and 50 stands for 5 degrees). Default set to 1
degree (value 10). The sensor will report
new temperature value to the controller
whenever temperature goes 1 degree up or
down.
Size: 1 byte dec.
Humidity Sensor
Reports relative humidity.
Parameter 3: Use it to set humidity
percentage change to be reported by the
sensor.
Values: 1 - 50 where 1 stands for 1% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Light Sensor
Reports light level in percentage (1-100).
Parameter 4: Use it to choose light
percentage change to be reported by the
sensor.
Values: 5 - 50 where 5 stands for 5% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Motion Sensor
Parameter 5: Use it to set trigger interval -
the time when motion is reported again
after initial trigger.
Values: 1 - 255 where 1 stands for 1 minute
and 255 stands for 255 minutes. Default set
to 3 minutes.
Size: 1 byte dec.
NOTE: Small interval will increase activity
and decrease battery life.
Parameter 6: Use it to adjust PIR sensor
sensitivity.
Values: 1 - 7, where 1 = very high sensitivity
and 7 = very low sensitivity. Default set to 4.
Size: 1 byte dec.
LED notifications
LED indicator will flash every 3 minutes or
whenever you press the Z-Wave button to
indicate temperature level.
How to read LED indicator colors?
Green = under 60°F
Blue = 60°-75°F
Yellow = 75°-83°F
Purple = 83°-97°F
Red = over 97°F / motion detected / tamper
switch triggered
Parameter 7: Use it to choose between LED
indicator modes.
Mode 1 = LED indicator is turned off (no
visual notifications).
Mode 2 = temperature indicated with
pulsing light. Motion indicated with flashing
light.
Mode 3 = temperature and motion
indicated with flashing light.
Mode 4 = no indication for temperature,
motion indicated with flashing light.
Values: 1 - 4. Default set to 3.
Size: 1 byte dec.
NOTE: Mode 2 will increase activity and
decrease battery life.
Tamper Switch
Tamper switch is activated whenever
sensor’s cover is removed while the device
is powered up. It will send an alarm
notification as scheduled.
Z-WAVE COMMAND CLASSES
This device requires the following
command classes to be supported and
recognized by your Z-Wave controller:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
WARRANTY
This Limited Warranty applies to physical goods,
and only for physical goods, purchased from
Zooz (the "Physical Goods").
What does this limited warranty cover?
This Limited Warranty covers any defects in
material or workmanship under normal use
according to instructions from the User Manual
during the Warranty Period. Warranty coverage
applies to purchases made from authorized
dealers only. See full list of Zooz distributors
here: getzooz.com/buy
During the Warranty Period, Zooz will repair or
replace, at no charge, products or parts of a
product that prove defective because of
improper material or workmanship, under
normal use and recommended maintenance.
Zooz does not assume the cost of return
shipping for warranty service.
How long does the coverage last?
The Warranty Period for Physical Goods
purchased from Zooz is 12 months from the
date you purchased this product.
What does this limited warranty not cover?
This Limited Warranty does not cover any
problem that is caused by:
- conditions, malfunctions or damage not
resulting from defects in material or
workmanship
- improper handling or installation of the
product
The warranty does not cover purchases from
unauthorized dealers or second-hand sources.
The warranty does not cover return shipping
cost for warranty service.
What do you have to do?
To obtain warranty service, please contact us to
determine the problem and offer a quick
solution for you: warranty@getzooz.com
You may also get in touch with the reseller of the
product directly to return or replace the product
within 30 days of purchase or within applicable
reseller’s returns period.
IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES
AND AFFILIATES BE LIABLE FOR ANY INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL, OR
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR
LOSS OF PROFITS, REVENUE, OR USE
INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHETHER IN AN ACTION IN CONTRACT, OR
OTHERWISE EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. ZOOZ'S
LIABILITY AND CUSTOMER'S EXCLUSIVE
REMEDY FOR ANY CAUSE OF ACTION ARISING IN
CONNECTION WITH THIS AGREEMENT OR THE
SALE OR USE OF THE PRODUCTS, WHETHER
BASED ON NEGLIGENCE, STRICT LIABILITY,
BREACH OF WARRANTY, BREACH OF
AGREEMENT, OR EQUITABLE PRINCIPLES, IS
EXPRESSLY LIMITED TO, AT ZOOZ'S OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE
PURCHASE PRICE FOR THAT PORTION OF
PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY
KIND ARISING IN CONNECTION WITH THIS
AGREEMENT OR THE SALE OR USE OF
PRODUCTS SHALL BE DEEMED WAIVED UNLESS
MADE IN WRITING WITHIN THIRTY (30) DAYS
FROM ZOOZ'S DELIVERY, OR THE DATE FIXED
FOR DELIVERY IN THE EVENT OF NONDELIVERY.
FCC NOTE
THE MANUFACTURER IS NOT RESPONSIBLE
FOR ANY RADIO OR TV INTERFERENCE CAUSED
BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT. SUCH MODIFICATIONS COULD
VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT. STORE INDOORS WHEN NOT IN
USE. SUITABLE FOR DRY LOCATIONS ONLY. DO
NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC
Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful
interference,
2. This device must accept any interference
received, including interference that may cause
undesired operation.
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used according to instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that
interference will not occur in any given
installation.
If this equipment causes harmful interference to
radio or television reception, the user may try to
correct the interference by taking one or more
of the following measures:
- Reorient or relocate receiving antenna
- Increase the separation between equipment
and receiver
- Connect equipment into a separate outlet or
circuit from receiver
- Consult the dealer or an experienced radio/TV
technician for additional assistance
All brand names displayed are trademarks of
their respective holders.
[c] Zooz 2016
ask@getzooz.com
www.getzooz.com
6B1Z-31UCD_V2
10 11 12 13 14 15 16 17 18

Depending on your Z-Wave gateway's home
automation software capabilities, you may
be able to associate your Z-Wave 4-in-1
sensor in groups with other Z-Wave devices
to schedule scenes and create events.
Zooz 4-in-1 sensor supports Group 1 with up
to five devices for lifeline communication. To
associate the sensor with other devices,
simply put your Z-Wave controller in
Association mode by sending the
appropriate command and put the 4-in-1
sensor in wake-up mode by pressing and
releasing its Z-Wave button.
ADVANCED SETTINGS
Once the 4-in-1 sensor is added to your Z-
Wave network, you are able to monitor the
values reported by the device on your
computer or mobile device.
Please refer to your controller's user guide
for advanced programming instructions as
they are a little different for every software.
Temperature Sensor
Parameter 1: Use this parameter to switch
from Fahrenheit to Celsius scale.
Values: 0 – Celsius. 1 – Fahrenheit (default).
Size: 1 byte dec.
Parameter 2: Use it to set temperature
change to be reported by the sensor.
Values: 1 - 50 (where 1 stands for 0.1 degree
and 50 stands for 5 degrees). Default set to 1
degree (value 10). The sensor will report
new temperature value to the controller
whenever temperature goes 1 degree up or
down.
Size: 1 byte dec.
Humidity Sensor
Reports relative humidity.
Parameter 3: Use it to set humidity
percentage change to be reported by the
sensor.
Values: 1 - 50 where 1 stands for 1% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Light Sensor
Reports light level in percentage (1-100).
Parameter 4: Use it to choose light
percentage change to be reported by the
sensor.
Values: 5 - 50 where 5 stands for 5% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Motion Sensor
Parameter 5: Use it to set trigger interval -
the time when motion is reported again
after initial trigger.
Values: 1 - 255 where 1 stands for 1 minute
and 255 stands for 255 minutes. Default set
to 3 minutes.
Size: 1 byte dec.
NOTE: Small interval will increase activity
and decrease battery life.
Parameter 6: Use it to adjust PIR sensor
sensitivity.
Values: 1 - 7, where 1 = very high sensitivity
and 7 = very low sensitivity. Default set to 4.
Size: 1 byte dec.
LED notifications
LED indicator will flash every 3 minutes or
whenever you press the Z-Wave button to
indicate temperature level.
How to read LED indicator colors?
Green = under 60°F
Blue = 60°-75°F
Yellow = 75°-83°F
Purple = 83°-97°F
Red = over 97°F / motion detected / tamper
switch triggered
Parameter 7: Use it to choose between LED
indicator modes.
Mode 1 = LED indicator is turned off (no
visual notifications).
Mode 2 = temperature indicated with
pulsing light. Motion indicated with flashing
light.
Mode 3 = temperature and motion
indicated with flashing light.
Mode 4 = no indication for temperature,
motion indicated with flashing light.
Values: 1 - 4. Default set to 3.
Size: 1 byte dec.
NOTE: Mode 2 will increase activity and
decrease battery life.
Tamper Switch
Tamper switch is activated whenever
sensor’s cover is removed while the device
is powered up. It will send an alarm
notification as scheduled.
Z-WAVE COMMAND CLASSES
This device requires the following
command classes to be supported and
recognized by your Z-Wave controller:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
WARRANTY
This Limited Warranty applies to physical goods,
and only for physical goods, purchased from
Zooz (the "Physical Goods").
What does this limited warranty cover?
This Limited Warranty covers any defects in
material or workmanship under normal use
according to instructions from the User Manual
during the Warranty Period. Warranty coverage
applies to purchases made from authorized
dealers only. See full list of Zooz distributors
here: getzooz.com/buy
During the Warranty Period, Zooz will repair or
replace, at no charge, products or parts of a
product that prove defective because of
improper material or workmanship, under
normal use and recommended maintenance.
Zooz does not assume the cost of return
shipping for warranty service.
How long does the coverage last?
The Warranty Period for Physical Goods
purchased from Zooz is 12 months from the
date you purchased this product.
What does this limited warranty not cover?
This Limited Warranty does not cover any
problem that is caused by:
- conditions, malfunctions or damage not
resulting from defects in material or
workmanship
- improper handling or installation of the
product
The warranty does not cover purchases from
unauthorized dealers or second-hand sources.
The warranty does not cover return shipping
cost for warranty service.
What do you have to do?
To obtain warranty service, please contact us to
determine the problem and offer a quick
solution for you: warranty@getzooz.com
You may also get in touch with the reseller of the
product directly to return or replace the product
within 30 days of purchase or within applicable
reseller’s returns period.
IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES
AND AFFILIATES BE LIABLE FOR ANY INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL, OR
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR
LOSS OF PROFITS, REVENUE, OR USE
INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHETHER IN AN ACTION IN CONTRACT, OR
OTHERWISE EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. ZOOZ'S
LIABILITY AND CUSTOMER'S EXCLUSIVE
REMEDY FOR ANY CAUSE OF ACTION ARISING IN
CONNECTION WITH THIS AGREEMENT OR THE
SALE OR USE OF THE PRODUCTS, WHETHER
BASED ON NEGLIGENCE, STRICT LIABILITY,
BREACH OF WARRANTY, BREACH OF
AGREEMENT, OR EQUITABLE PRINCIPLES, IS
EXPRESSLY LIMITED TO, AT ZOOZ'S OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE
PURCHASE PRICE FOR THAT PORTION OF
PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY
KIND ARISING IN CONNECTION WITH THIS
AGREEMENT OR THE SALE OR USE OF
PRODUCTS SHALL BE DEEMED WAIVED UNLESS
MADE IN WRITING WITHIN THIRTY (30) DAYS
FROM ZOOZ'S DELIVERY, OR THE DATE FIXED
FOR DELIVERY IN THE EVENT OF NONDELIVERY.
FCC NOTE
THE MANUFACTURER IS NOT RESPONSIBLE
FOR ANY RADIO OR TV INTERFERENCE CAUSED
BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT. SUCH MODIFICATIONS COULD
VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT. STORE INDOORS WHEN NOT IN
USE. SUITABLE FOR DRY LOCATIONS ONLY. DO
NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC
Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful
interference,
2. This device must accept any interference
received, including interference that may cause
undesired operation.
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used according to instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that
interference will not occur in any given
installation.
If this equipment causes harmful interference to
radio or television reception, the user may try to
correct the interference by taking one or more
of the following measures:
- Reorient or relocate receiving antenna
- Increase the separation between equipment
and receiver
- Connect equipment into a separate outlet or
circuit from receiver
- Consult the dealer or an experienced radio/TV
technician for additional assistance
All brand names displayed are trademarks of
their respective holders.
[c] Zooz 2016
ask@getzooz.com
www.getzooz.com
6B1Z-31UCD_V2
10 11 12 13 14 15 16 17 18

Depending on your Z-Wave gateway's home
automation software capabilities, you may
be able to associate your Z-Wave 4-in-1
sensor in groups with other Z-Wave devices
to schedule scenes and create events.
Zooz 4-in-1 sensor supports Group 1 with up
to five devices for lifeline communication. To
associate the sensor with other devices,
simply put your Z-Wave controller in
Association mode by sending the
appropriate command and put the 4-in-1
sensor in wake-up mode by pressing and
releasing its Z-Wave button.
ADVANCED SETTINGS
Once the 4-in-1 sensor is added to your Z-
Wave network, you are able to monitor the
values reported by the device on your
computer or mobile device.
Please refer to your controller's user guide
for advanced programming instructions as
they are a little different for every software.
Temperature Sensor
Parameter 1: Use this parameter to switch
from Fahrenheit to Celsius scale.
Values: 0 – Celsius. 1 – Fahrenheit (default).
Size: 1 byte dec.
Parameter 2: Use it to set temperature
change to be reported by the sensor.
Values: 1 - 50 (where 1 stands for 0.1 degree
and 50 stands for 5 degrees). Default set to 1
degree (value 10). The sensor will report
new temperature value to the controller
whenever temperature goes 1 degree up or
down.
Size: 1 byte dec.
Humidity Sensor
Reports relative humidity.
Parameter 3: Use it to set humidity
percentage change to be reported by the
sensor.
Values: 1 - 50 where 1 stands for 1% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Light Sensor
Reports light level in percentage (1-100).
Parameter 4: Use it to choose light
percentage change to be reported by the
sensor.
Values: 5 - 50 where 5 stands for 5% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Motion Sensor
Parameter 5: Use it to set trigger interval -
the time when motion is reported again
after initial trigger.
Values: 1 - 255 where 1 stands for 1 minute
and 255 stands for 255 minutes. Default set
to 3 minutes.
Size: 1 byte dec.
NOTE: Small interval will increase activity
and decrease battery life.
Parameter 6: Use it to adjust PIR sensor
sensitivity.
Values: 1 - 7, where 1 = very high sensitivity
and 7 = very low sensitivity. Default set to 4.
Size: 1 byte dec.
LED notifications
LED indicator will flash every 3 minutes or
whenever you press the Z-Wave button to
indicate temperature level.
How to read LED indicator colors?
Green = under 60°F
Blue = 60°-75°F
Yellow = 75°-83°F
Purple = 83°-97°F
Red = over 97°F / motion detected / tamper
switch triggered
Parameter 7: Use it to choose between LED
indicator modes.
Mode 1 = LED indicator is turned off (no
visual notifications).
Mode 2 = temperature indicated with
pulsing light. Motion indicated with flashing
light.
Mode 3 = temperature and motion
indicated with flashing light.
Mode 4 = no indication for temperature,
motion indicated with flashing light.
Values: 1 - 4. Default set to 3.
Size: 1 byte dec.
NOTE: Mode 2 will increase activity and
decrease battery life.
Tamper Switch
Tamper switch is activated whenever
sensor’s cover is removed while the device
is powered up. It will send an alarm
notification as scheduled.
Z-WAVE COMMAND CLASSES
This device requires the following
command classes to be supported and
recognized by your Z-Wave controller:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
WARRANTY
This Limited Warranty applies to physical goods,
and only for physical goods, purchased from
Zooz (the "Physical Goods").
What does this limited warranty cover?
This Limited Warranty covers any defects in
material or workmanship under normal use
according to instructions from the User Manual
during the Warranty Period. Warranty coverage
applies to purchases made from authorized
dealers only. See full list of Zooz distributors
here: getzooz.com/buy
During the Warranty Period, Zooz will repair or
replace, at no charge, products or parts of a
product that prove defective because of
improper material or workmanship, under
normal use and recommended maintenance.
Zooz does not assume the cost of return
shipping for warranty service.
How long does the coverage last?
The Warranty Period for Physical Goods
purchased from Zooz is 12 months from the
date you purchased this product.
What does this limited warranty not cover?
This Limited Warranty does not cover any
problem that is caused by:
- conditions, malfunctions or damage not
resulting from defects in material or
workmanship
- improper handling or installation of the
product
The warranty does not cover purchases from
unauthorized dealers or second-hand sources.
The warranty does not cover return shipping
cost for warranty service.
What do you have to do?
To obtain warranty service, please contact us to
determine the problem and offer a quick
solution for you: warranty@getzooz.com
You may also get in touch with the reseller of the
product directly to return or replace the product
within 30 days of purchase or within applicable
reseller’s returns period.
IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES
AND AFFILIATES BE LIABLE FOR ANY INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL, OR
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR
LOSS OF PROFITS, REVENUE, OR USE
INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHETHER IN AN ACTION IN CONTRACT, OR
OTHERWISE EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. ZOOZ'S
LIABILITY AND CUSTOMER'S EXCLUSIVE
REMEDY FOR ANY CAUSE OF ACTION ARISING IN
CONNECTION WITH THIS AGREEMENT OR THE
SALE OR USE OF THE PRODUCTS, WHETHER
BASED ON NEGLIGENCE, STRICT LIABILITY,
BREACH OF WARRANTY, BREACH OF
AGREEMENT, OR EQUITABLE PRINCIPLES, IS
EXPRESSLY LIMITED TO, AT ZOOZ'S OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE
PURCHASE PRICE FOR THAT PORTION OF
PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY
KIND ARISING IN CONNECTION WITH THIS
AGREEMENT OR THE SALE OR USE OF
PRODUCTS SHALL BE DEEMED WAIVED UNLESS
MADE IN WRITING WITHIN THIRTY (30) DAYS
FROM ZOOZ'S DELIVERY, OR THE DATE FIXED
FOR DELIVERY IN THE EVENT OF NONDELIVERY.
FCC NOTE
THE MANUFACTURER IS NOT RESPONSIBLE
FOR ANY RADIO OR TV INTERFERENCE CAUSED
BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT. SUCH MODIFICATIONS COULD
VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT. STORE INDOORS WHEN NOT IN
USE. SUITABLE FOR DRY LOCATIONS ONLY. DO
NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC
Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful
interference,
2. This device must accept any interference
received, including interference that may cause
undesired operation.
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used according to instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that
interference will not occur in any given
installation.
If this equipment causes harmful interference to
radio or television reception, the user may try to
correct the interference by taking one or more
of the following measures:
- Reorient or relocate receiving antenna
- Increase the separation between equipment
and receiver
- Connect equipment into a separate outlet or
circuit from receiver
- Consult the dealer or an experienced radio/TV
technician for additional assistance
All brand names displayed are trademarks of
their respective holders.
[c] Zooz 2016
ask@getzooz.com
www.getzooz.com
6B1Z-31UCD_V2
10 11 12 13 14 15 16 17 18

Depending on your Z-Wave gateway's home
automation software capabilities, you may
be able to associate your Z-Wave 4-in-1
sensor in groups with other Z-Wave devices
to schedule scenes and create events.
Zooz 4-in-1 sensor supports Group 1 with up
to five devices for lifeline communication. To
associate the sensor with other devices,
simply put your Z-Wave controller in
Association mode by sending the
appropriate command and put the 4-in-1
sensor in wake-up mode by pressing and
releasing its Z-Wave button.
ADVANCED SETTINGS
Once the 4-in-1 sensor is added to your Z-
Wave network, you are able to monitor the
values reported by the device on your
computer or mobile device.
Please refer to your controller's user guide
for advanced programming instructions as
they are a little different for every software.
Temperature Sensor
Parameter 1: Use this parameter to switch
from Fahrenheit to Celsius scale.
Values: 0 – Celsius. 1 – Fahrenheit (default).
Size: 1 byte dec.
Parameter 2: Use it to set temperature
change to be reported by the sensor.
Values: 1 - 50 (where 1 stands for 0.1 degree
and 50 stands for 5 degrees). Default set to 1
degree (value 10). The sensor will report
new temperature value to the controller
whenever temperature goes 1 degree up or
down.
Size: 1 byte dec.
Humidity Sensor
Reports relative humidity.
Parameter 3: Use it to set humidity
percentage change to be reported by the
sensor.
Values: 1 - 50 where 1 stands for 1% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Light Sensor
Reports light level in percentage (1-100).
Parameter 4: Use it to choose light
percentage change to be reported by the
sensor.
Values: 5 - 50 where 5 stands for 5% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Motion Sensor
Parameter 5: Use it to set trigger interval -
the time when motion is reported again
after initial trigger.
Values: 1 - 255 where 1 stands for 1 minute
and 255 stands for 255 minutes. Default set
to 3 minutes.
Size: 1 byte dec.
NOTE: Small interval will increase activity
and decrease battery life.
Parameter 6: Use it to adjust PIR sensor
sensitivity.
Values: 1 - 7, where 1 = very high sensitivity
and 7 = very low sensitivity. Default set to 4.
Size: 1 byte dec.
LED notifications
LED indicator will flash every 3 minutes or
whenever you press the Z-Wave button to
indicate temperature level.
How to read LED indicator colors?
Green = under 60°F
Blue = 60°-75°F
Yellow = 75°-83°F
Purple = 83°-97°F
Red = over 97°F / motion detected / tamper
switch triggered
Parameter 7: Use it to choose between LED
indicator modes.
Mode 1 = LED indicator is turned off (no
visual notifications).
Mode 2 = temperature indicated with
pulsing light. Motion indicated with flashing
light.
Mode 3 = temperature and motion
indicated with flashing light.
Mode 4 = no indication for temperature,
motion indicated with flashing light.
Values: 1 - 4. Default set to 3.
Size: 1 byte dec.
NOTE: Mode 2 will increase activity and
decrease battery life.
Tamper Switch
Tamper switch is activated whenever
sensor’s cover is removed while the device
is powered up. It will send an alarm
notification as scheduled.
Z-WAVE COMMAND CLASSES
This device requires the following
command classes to be supported and
recognized by your Z-Wave controller:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
WARRANTY
This Limited Warranty applies to physical goods,
and only for physical goods, purchased from
Zooz (the "Physical Goods").
What does this limited warranty cover?
This Limited Warranty covers any defects in
material or workmanship under normal use
according to instructions from the User Manual
during the Warranty Period. Warranty coverage
applies to purchases made from authorized
dealers only. See full list of Zooz distributors
here: getzooz.com/buy
During the Warranty Period, Zooz will repair or
replace, at no charge, products or parts of a
product that prove defective because of
improper material or workmanship, under
normal use and recommended maintenance.
Zooz does not assume the cost of return
shipping for warranty service.
How long does the coverage last?
The Warranty Period for Physical Goods
purchased from Zooz is 12 months from the
date you purchased this product.
What does this limited warranty not cover?
This Limited Warranty does not cover any
problem that is caused by:
- conditions, malfunctions or damage not
resulting from defects in material or
workmanship
- improper handling or installation of the
product
The warranty does not cover purchases from
unauthorized dealers or second-hand sources.
The warranty does not cover return shipping
cost for warranty service.
What do you have to do?
To obtain warranty service, please contact us to
determine the problem and offer a quick
solution for you: warranty@getzooz.com
You may also get in touch with the reseller of the
product directly to return or replace the product
within 30 days of purchase or within applicable
reseller’s returns period.
IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES
AND AFFILIATES BE LIABLE FOR ANY INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL, OR
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR
LOSS OF PROFITS, REVENUE, OR USE
INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHETHER IN AN ACTION IN CONTRACT, OR
OTHERWISE EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. ZOOZ'S
LIABILITY AND CUSTOMER'S EXCLUSIVE
REMEDY FOR ANY CAUSE OF ACTION ARISING IN
CONNECTION WITH THIS AGREEMENT OR THE
SALE OR USE OF THE PRODUCTS, WHETHER
BASED ON NEGLIGENCE, STRICT LIABILITY,
BREACH OF WARRANTY, BREACH OF
AGREEMENT, OR EQUITABLE PRINCIPLES, IS
EXPRESSLY LIMITED TO, AT ZOOZ'S OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE
PURCHASE PRICE FOR THAT PORTION OF
PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY
KIND ARISING IN CONNECTION WITH THIS
AGREEMENT OR THE SALE OR USE OF
PRODUCTS SHALL BE DEEMED WAIVED UNLESS
MADE IN WRITING WITHIN THIRTY (30) DAYS
FROM ZOOZ'S DELIVERY, OR THE DATE FIXED
FOR DELIVERY IN THE EVENT OF NONDELIVERY.
FCC NOTE
THE MANUFACTURER IS NOT RESPONSIBLE
FOR ANY RADIO OR TV INTERFERENCE CAUSED
BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT. SUCH MODIFICATIONS COULD
VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT. STORE INDOORS WHEN NOT IN
USE. SUITABLE FOR DRY LOCATIONS ONLY. DO
NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC
Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful
interference,
2. This device must accept any interference
received, including interference that may cause
undesired operation.
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used according to instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that
interference will not occur in any given
installation.
If this equipment causes harmful interference to
radio or television reception, the user may try to
correct the interference by taking one or more
of the following measures:
- Reorient or relocate receiving antenna
- Increase the separation between equipment
and receiver
- Connect equipment into a separate outlet or
circuit from receiver
- Consult the dealer or an experienced radio/TV
technician for additional assistance
All brand names displayed are trademarks of
their respective holders.
[c] Zooz 2016
ask@getzooz.com
www.getzooz.com
6B1Z-31UCD_V2
10 11 12 13 14 15 16 17 18

Depending on your Z-Wave gateway's home
automation software capabilities, you may
be able to associate your Z-Wave 4-in-1
sensor in groups with other Z-Wave devices
to schedule scenes and create events.
Zooz 4-in-1 sensor supports Group 1 with up
to five devices for lifeline communication. To
associate the sensor with other devices,
simply put your Z-Wave controller in
Association mode by sending the
appropriate command and put the 4-in-1
sensor in wake-up mode by pressing and
releasing its Z-Wave button.
ADVANCED SETTINGS
Once the 4-in-1 sensor is added to your Z-
Wave network, you are able to monitor the
values reported by the device on your
computer or mobile device.
Please refer to your controller's user guide
for advanced programming instructions as
they are a little different for every software.
Temperature Sensor
Parameter 1: Use this parameter to switch
from Fahrenheit to Celsius scale.
Values: 0 – Celsius. 1 – Fahrenheit (default).
Size: 1 byte dec.
Parameter 2: Use it to set temperature
change to be reported by the sensor.
Values: 1 - 50 (where 1 stands for 0.1 degree
and 50 stands for 5 degrees). Default set to 1
degree (value 10). The sensor will report
new temperature value to the controller
whenever temperature goes 1 degree up or
down.
Size: 1 byte dec.
Humidity Sensor
Reports relative humidity.
Parameter 3: Use it to set humidity
percentage change to be reported by the
sensor.
Values: 1 - 50 where 1 stands for 1% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Light Sensor
Reports light level in percentage (1-100).
Parameter 4: Use it to choose light
percentage change to be reported by the
sensor.
Values: 5 - 50 where 5 stands for 5% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Motion Sensor
Parameter 5: Use it to set trigger interval -
the time when motion is reported again
after initial trigger.
Values: 1 - 255 where 1 stands for 1 minute
and 255 stands for 255 minutes. Default set
to 3 minutes.
Size: 1 byte dec.
NOTE: Small interval will increase activity
and decrease battery life.
Parameter 6: Use it to adjust PIR sensor
sensitivity.
Values: 1 - 7, where 1 = very high sensitivity
and 7 = very low sensitivity. Default set to 4.
Size: 1 byte dec.
LED notifications
LED indicator will flash every 3 minutes or
whenever you press the Z-Wave button to
indicate temperature level.
How to read LED indicator colors?
Green = under 60°F
Blue = 60°-75°F
Yellow = 75°-83°F
Purple = 83°-97°F
Red = over 97°F / motion detected / tamper
switch triggered
Parameter 7: Use it to choose between LED
indicator modes.
Mode 1 = LED indicator is turned off (no
visual notifications).
Mode 2 = temperature indicated with
pulsing light. Motion indicated with flashing
light.
Mode 3 = temperature and motion
indicated with flashing light.
Mode 4 = no indication for temperature,
motion indicated with flashing light.
Values: 1 - 4. Default set to 3.
Size: 1 byte dec.
NOTE: Mode 2 will increase activity and
decrease battery life.
Tamper Switch
Tamper switch is activated whenever
sensor’s cover is removed while the device
is powered up. It will send an alarm
notification as scheduled.
Z-WAVE COMMAND CLASSES
This device requires the following
command classes to be supported and
recognized by your Z-Wave controller:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
WARRANTY
This Limited Warranty applies to physical goods,
and only for physical goods, purchased from
Zooz (the "Physical Goods").
What does this limited warranty cover?
This Limited Warranty covers any defects in
material or workmanship under normal use
according to instructions from the User Manual
during the Warranty Period. Warranty coverage
applies to purchases made from authorized
dealers only. See full list of Zooz distributors
here: getzooz.com/buy
During the Warranty Period, Zooz will repair or
replace, at no charge, products or parts of a
product that prove defective because of
improper material or workmanship, under
normal use and recommended maintenance.
Zooz does not assume the cost of return
shipping for warranty service.
How long does the coverage last?
The Warranty Period for Physical Goods
purchased from Zooz is 12 months from the
date you purchased this product.
What does this limited warranty not cover?
This Limited Warranty does not cover any
problem that is caused by:
- conditions, malfunctions or damage not
resulting from defects in material or
workmanship
- improper handling or installation of the
product
The warranty does not cover purchases from
unauthorized dealers or second-hand sources.
The warranty does not cover return shipping
cost for warranty service.
What do you have to do?
To obtain warranty service, please contact us to
determine the problem and offer a quick
solution for you: warranty@getzooz.com
You may also get in touch with the reseller of the
product directly to return or replace the product
within 30 days of purchase or within applicable
reseller’s returns period.
IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES
AND AFFILIATES BE LIABLE FOR ANY INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL, OR
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR
LOSS OF PROFITS, REVENUE, OR USE
INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHETHER IN AN ACTION IN CONTRACT, OR
OTHERWISE EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. ZOOZ'S
LIABILITY AND CUSTOMER'S EXCLUSIVE
REMEDY FOR ANY CAUSE OF ACTION ARISING IN
CONNECTION WITH THIS AGREEMENT OR THE
SALE OR USE OF THE PRODUCTS, WHETHER
BASED ON NEGLIGENCE, STRICT LIABILITY,
BREACH OF WARRANTY, BREACH OF
AGREEMENT, OR EQUITABLE PRINCIPLES, IS
EXPRESSLY LIMITED TO, AT ZOOZ'S OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE
PURCHASE PRICE FOR THAT PORTION OF
PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY
KIND ARISING IN CONNECTION WITH THIS
AGREEMENT OR THE SALE OR USE OF
PRODUCTS SHALL BE DEEMED WAIVED UNLESS
MADE IN WRITING WITHIN THIRTY (30) DAYS
FROM ZOOZ'S DELIVERY, OR THE DATE FIXED
FOR DELIVERY IN THE EVENT OF NONDELIVERY.
FCC NOTE
THE MANUFACTURER IS NOT RESPONSIBLE
FOR ANY RADIO OR TV INTERFERENCE CAUSED
BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT. SUCH MODIFICATIONS COULD
VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT. STORE INDOORS WHEN NOT IN
USE. SUITABLE FOR DRY LOCATIONS ONLY. DO
NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC
Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful
interference,
2. This device must accept any interference
received, including interference that may cause
undesired operation.
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used according to instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that
interference will not occur in any given
installation.
If this equipment causes harmful interference to
radio or television reception, the user may try to
correct the interference by taking one or more
of the following measures:
- Reorient or relocate receiving antenna
- Increase the separation between equipment
and receiver
- Connect equipment into a separate outlet or
circuit from receiver
- Consult the dealer or an experienced radio/TV
technician for additional assistance
All brand names displayed are trademarks of
their respective holders.
[c] Zooz 2016
ask@getzooz.com
www.getzooz.com
6B1Z-31UCD_V2
10 11 12 13 14 15 16 17 18

Depending on your Z-Wave gateway's home
automation software capabilities, you may
be able to associate your Z-Wave 4-in-1
sensor in groups with other Z-Wave devices
to schedule scenes and create events.
Zooz 4-in-1 sensor supports Group 1 with up
to five devices for lifeline communication. To
associate the sensor with other devices,
simply put your Z-Wave controller in
Association mode by sending the
appropriate command and put the 4-in-1
sensor in wake-up mode by pressing and
releasing its Z-Wave button.
ADVANCED SETTINGS
Once the 4-in-1 sensor is added to your Z-
Wave network, you are able to monitor the
values reported by the device on your
computer or mobile device.
Please refer to your controller's user guide
for advanced programming instructions as
they are a little different for every software.
Temperature Sensor
Parameter 1: Use this parameter to switch
from Fahrenheit to Celsius scale.
Values: 0 – Celsius. 1 – Fahrenheit (default).
Size: 1 byte dec.
Parameter 2: Use it to set temperature
change to be reported by the sensor.
Values: 1 - 50 (where 1 stands for 0.1 degree
and 50 stands for 5 degrees). Default set to 1
degree (value 10). The sensor will report
new temperature value to the controller
whenever temperature goes 1 degree up or
down.
Size: 1 byte dec.
Humidity Sensor
Reports relative humidity.
Parameter 3: Use it to set humidity
percentage change to be reported by the
sensor.
Values: 1 - 50 where 1 stands for 1% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Light Sensor
Reports light level in percentage (1-100).
Parameter 4: Use it to choose light
percentage change to be reported by the
sensor.
Values: 5 - 50 where 5 stands for 5% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Motion Sensor
Parameter 5: Use it to set trigger interval -
the time when motion is reported again
after initial trigger.
Values: 1 - 255 where 1 stands for 1 minute
and 255 stands for 255 minutes. Default set
to 3 minutes.
Size: 1 byte dec.
NOTE: Small interval will increase activity
and decrease battery life.
Parameter 6: Use it to adjust PIR sensor
sensitivity.
Values: 1 - 7, where 1 = very high sensitivity
and 7 = very low sensitivity. Default set to 4.
Size: 1 byte dec.
LED notifications
LED indicator will flash every 3 minutes or
whenever you press the Z-Wave button to
indicate temperature level.
How to read LED indicator colors?
Green = under 60°F
Blue = 60°-75°F
Yellow = 75°-83°F
Purple = 83°-97°F
Red = over 97°F / motion detected / tamper
switch triggered
Parameter 7: Use it to choose between LED
indicator modes.
Mode 1 = LED indicator is turned off (no
visual notifications).
Mode 2 = temperature indicated with
pulsing light. Motion indicated with flashing
light.
Mode 3 = temperature and motion
indicated with flashing light.
Mode 4 = no indication for temperature,
motion indicated with flashing light.
Values: 1 - 4. Default set to 3.
Size: 1 byte dec.
NOTE: Mode 2 will increase activity and
decrease battery life.
Tamper Switch
Tamper switch is activated whenever
sensor’s cover is removed while the device
is powered up. It will send an alarm
notification as scheduled.
Z-WAVE COMMAND CLASSES
This device requires the following
command classes to be supported and
recognized by your Z-Wave controller:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
WARRANTY
This Limited Warranty applies to physical goods,
and only for physical goods, purchased from
Zooz (the "Physical Goods").
What does this limited warranty cover?
This Limited Warranty covers any defects in
material or workmanship under normal use
according to instructions from the User Manual
during the Warranty Period. Warranty coverage
applies to purchases made from authorized
dealers only. See full list of Zooz distributors
here: getzooz.com/buy
During the Warranty Period, Zooz will repair or
replace, at no charge, products or parts of a
product that prove defective because of
improper material or workmanship, under
normal use and recommended maintenance.
Zooz does not assume the cost of return
shipping for warranty service.
How long does the coverage last?
The Warranty Period for Physical Goods
purchased from Zooz is 12 months from the
date you purchased this product.
What does this limited warranty not cover?
This Limited Warranty does not cover any
problem that is caused by:
- conditions, malfunctions or damage not
resulting from defects in material or
workmanship
- improper handling or installation of the
product
The warranty does not cover purchases from
unauthorized dealers or second-hand sources.
The warranty does not cover return shipping
cost for warranty service.
What do you have to do?
To obtain warranty service, please contact us to
determine the problem and offer a quick
solution for you: [email protected]
You may also get in touch with the reseller of the
product directly to return or replace the product
within 30 days of purchase or within applicable
reseller’s returns period.
IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES
AND AFFILIATES BE LIABLE FOR ANY INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL, OR
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR
LOSS OF PROFITS, REVENUE, OR USE
INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHETHER IN AN ACTION IN CONTRACT, OR
OTHERWISE EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. ZOOZ'S
LIABILITY AND CUSTOMER'S EXCLUSIVE
REMEDY FOR ANY CAUSE OF ACTION ARISING IN
CONNECTION WITH THIS AGREEMENT OR THE
SALE OR USE OF THE PRODUCTS, WHETHER
BASED ON NEGLIGENCE, STRICT LIABILITY,
BREACH OF WARRANTY, BREACH OF
AGREEMENT, OR EQUITABLE PRINCIPLES, IS
EXPRESSLY LIMITED TO, AT ZOOZ'S OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE
PURCHASE PRICE FOR THAT PORTION OF
PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY
KIND ARISING IN CONNECTION WITH THIS
AGREEMENT OR THE SALE OR USE OF
PRODUCTS SHALL BE DEEMED WAIVED UNLESS
MADE IN WRITING WITHIN THIRTY (30) DAYS
FROM ZOOZ'S DELIVERY, OR THE DATE FIXED
FOR DELIVERY IN THE EVENT OF NONDELIVERY.
FCC NOTE
THE MANUFACTURER IS NOT RESPONSIBLE
FOR ANY RADIO OR TV INTERFERENCE CAUSED
BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT. SUCH MODIFICATIONS COULD
VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT. STORE INDOORS WHEN NOT IN
USE. SUITABLE FOR DRY LOCATIONS ONLY. DO
NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC
Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful
interference,
2. This device must accept any interference
received, including interference that may cause
undesired operation.
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used according to instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that
interference will not occur in any given
installation.
If this equipment causes harmful interference to
radio or television reception, the user may try to
correct the interference by taking one or more
of the following measures:
- Reorient or relocate receiving antenna
- Increase the separation between equipment
and receiver
- Connect equipment into a separate outlet or
circuit from receiver
- Consult the dealer or an experienced radio/TV
technician for additional assistance
All brand names displayed are trademarks of
their respective holders.
[c] Zooz 2016
ask@getzooz.com
www.getzooz.com
6B1Z-31UCD_V2
10 11 12 13 14 15 16 17 18

Depending on your Z-Wave gateway's home
automation software capabilities, you may
be able to associate your Z-Wave 4-in-1
sensor in groups with other Z-Wave devices
to schedule scenes and create events.
Zooz 4-in-1 sensor supports Group 1 with up
to five devices for lifeline communication. To
associate the sensor with other devices,
simply put your Z-Wave controller in
Association mode by sending the
appropriate command and put the 4-in-1
sensor in wake-up mode by pressing and
releasing its Z-Wave button.
ADVANCED SETTINGS
Once the 4-in-1 sensor is added to your Z-
Wave network, you are able to monitor the
values reported by the device on your
computer or mobile device.
Please refer to your controller's user guide
for advanced programming instructions as
they are a little different for every software.
Temperature Sensor
Parameter 1: Use this parameter to switch
from Fahrenheit to Celsius scale.
Values: 0 – Celsius. 1 – Fahrenheit (default).
Size: 1 byte dec.
Parameter 2: Use it to set temperature
change to be reported by the sensor.
Values: 1 - 50 (where 1 stands for 0.1 degree
and 50 stands for 5 degrees). Default set to 1
degree (value 10). The sensor will report
new temperature value to the controller
whenever temperature goes 1 degree up or
down.
Size: 1 byte dec.
Humidity Sensor
Reports relative humidity.
Parameter 3: Use it to set humidity
percentage change to be reported by the
sensor.
Values: 1 - 50 where 1 stands for 1% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Light Sensor
Reports light level in percentage (1-100).
Parameter 4: Use it to choose light
percentage change to be reported by the
sensor.
Values: 5 - 50 where 5 stands for 5% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Motion Sensor
Parameter 5: Use it to set trigger interval -
the time when motion is reported again
after initial trigger.
Values: 1 - 255 where 1 stands for 1 minute
and 255 stands for 255 minutes. Default set
to 3 minutes.
Size: 1 byte dec.
NOTE: Small interval will increase activity
and decrease battery life.
Parameter 6: Use it to adjust PIR sensor
sensitivity.
Values: 1 - 7, where 1 = very high sensitivity
and 7 = very low sensitivity. Default set to 4.
Size: 1 byte dec.
LED notifications
LED indicator will flash every 3 minutes or
whenever you press the Z-Wave button to
indicate temperature level.
How to read LED indicator colors?
Green = under 60°F
Blue = 60°-75°F
Yellow = 75°-83°F
Purple = 83°-97°F
Red = over 97°F / motion detected / tamper
switch triggered
Parameter 7: Use it to choose between LED
indicator modes.
Mode 1 = LED indicator is turned off (no
visual notifications).
Mode 2 = temperature indicated with
pulsing light. Motion indicated with flashing
light.
Mode 3 = temperature and motion
indicated with flashing light.
Mode 4 = no indication for temperature,
motion indicated with flashing light.
Values: 1 - 4. Default set to 3.
Size: 1 byte dec.
NOTE: Mode 2 will increase activity and
decrease battery life.
Tamper Switch
Tamper switch is activated whenever
sensor’s cover is removed while the device
is powered up. It will send an alarm
notification as scheduled.
Z-WAVE COMMAND CLASSES
This device requires the following
command classes to be supported and
recognized by your Z-Wave controller:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
WARRANTY
This Limited Warranty applies to physical goods,
and only for physical goods, purchased from
Zooz (the "Physical Goods").
What does this limited warranty cover?
This Limited Warranty covers any defects in
material or workmanship under normal use
according to instructions from the User Manual
during the Warranty Period. Warranty coverage
applies to purchases made from authorized
dealers only. See full list of Zooz distributors
here: getzooz.com/buy
During the Warranty Period, Zooz will repair or
replace, at no charge, products or parts of a
product that prove defective because of
improper material or workmanship, under
normal use and recommended maintenance.
Zooz does not assume the cost of return
shipping for warranty service.
How long does the coverage last?
The Warranty Period for Physical Goods
purchased from Zooz is 12 months from the
date you purchased this product.
What does this limited warranty not cover?
This Limited Warranty does not cover any
problem that is caused by:
- conditions, malfunctions or damage not
resulting from defects in material or
workmanship
- improper handling or installation of the
product
The warranty does not cover purchases from
unauthorized dealers or second-hand sources.
The warranty does not cover return shipping
cost for warranty service.
What do you have to do?
To obtain warranty service, please contact us to
determine the problem and offer a quick
solution for you: [email protected]
You may also get in touch with the reseller of the
product directly to return or replace the product
within 30 days of purchase or within applicable
reseller’s returns period.
IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES
AND AFFILIATES BE LIABLE FOR ANY INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL, OR
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR
LOSS OF PROFITS, REVENUE, OR USE
INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHETHER IN AN ACTION IN CONTRACT, OR
OTHERWISE EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. ZOOZ'S
LIABILITY AND CUSTOMER'S EXCLUSIVE
REMEDY FOR ANY CAUSE OF ACTION ARISING IN
CONNECTION WITH THIS AGREEMENT OR THE
SALE OR USE OF THE PRODUCTS, WHETHER
BASED ON NEGLIGENCE, STRICT LIABILITY,
BREACH OF WARRANTY, BREACH OF
AGREEMENT, OR EQUITABLE PRINCIPLES, IS
EXPRESSLY LIMITED TO, AT ZOOZ'S OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE
PURCHASE PRICE FOR THAT PORTION OF
PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY
KIND ARISING IN CONNECTION WITH THIS
AGREEMENT OR THE SALE OR USE OF
PRODUCTS SHALL BE DEEMED WAIVED UNLESS
MADE IN WRITING WITHIN THIRTY (30) DAYS
FROM ZOOZ'S DELIVERY, OR THE DATE FIXED
FOR DELIVERY IN THE EVENT OF NONDELIVERY.
FCC NOTE
THE MANUFACTURER IS NOT RESPONSIBLE
FOR ANY RADIO OR TV INTERFERENCE CAUSED
BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT. SUCH MODIFICATIONS COULD
VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT. STORE INDOORS WHEN NOT IN
USE. SUITABLE FOR DRY LOCATIONS ONLY. DO
NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC
Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful
interference,
2. This device must accept any interference
received, including interference that may cause
undesired operation.
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used according to instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that
interference will not occur in any given
installation.
If this equipment causes harmful interference to
radio or television reception, the user may try to
correct the interference by taking one or more
of the following measures:
- Reorient or relocate receiving antenna
- Increase the separation between equipment
and receiver
- Connect equipment into a separate outlet or
circuit from receiver
- Consult the dealer or an experienced radio/TV
technician for additional assistance
All brand names displayed are trademarks of
their respective holders.
[c] Zooz 2016
ask@getzooz.com
www.getzooz.com
6B1Z-31UCD_V2
10 11 12 13 14 15 16 17 18

Depending on your Z-Wave gateway's home
automation software capabilities, you may
be able to associate your Z-Wave 4-in-1
sensor in groups with other Z-Wave devices
to schedule scenes and create events.
Zooz 4-in-1 sensor supports Group 1 with up
to five devices for lifeline communication. To
associate the sensor with other devices,
simply put your Z-Wave controller in
Association mode by sending the
appropriate command and put the 4-in-1
sensor in wake-up mode by pressing and
releasing its Z-Wave button.
ADVANCED SETTINGS
Once the 4-in-1 sensor is added to your Z-
Wave network, you are able to monitor the
values reported by the device on your
computer or mobile device.
Please refer to your controller's user guide
for advanced programming instructions as
they are a little different for every software.
Temperature Sensor
Parameter 1: Use this parameter to switch
from Fahrenheit to Celsius scale.
Values: 0 – Celsius. 1 – Fahrenheit (default).
Size: 1 byte dec.
Parameter 2: Use it to set temperature
change to be reported by the sensor.
Values: 1 - 50 (where 1 stands for 0.1 degree
and 50 stands for 5 degrees). Default set to 1
degree (value 10). The sensor will report
new temperature value to the controller
whenever temperature goes 1 degree up or
down.
Size: 1 byte dec.
Humidity Sensor
Reports relative humidity.
Parameter 3: Use it to set humidity
percentage change to be reported by the
sensor.
Values: 1 - 50 where 1 stands for 1% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Light Sensor
Reports light level in percentage (1-100).
Parameter 4: Use it to choose light
percentage change to be reported by the
sensor.
Values: 5 - 50 where 5 stands for 5% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Motion Sensor
Parameter 5: Use it to set trigger interval -
the time when motion is reported again
after initial trigger.
Values: 1 - 255 where 1 stands for 1 minute
and 255 stands for 255 minutes. Default set
to 3 minutes.
Size: 1 byte dec.
NOTE: Small interval will increase activity
and decrease battery life.
Parameter 6: Use it to adjust PIR sensor
sensitivity.
Values: 1 - 7, where 1 = very high sensitivity
and 7 = very low sensitivity. Default set to 4.
Size: 1 byte dec.
LED notifications
LED indicator will flash every 3 minutes or
whenever you press the Z-Wave button to
indicate temperature level.
How to read LED indicator colors?
Green = under 60°F
Blue = 60°-75°F
Yellow = 75°-83°F
Purple = 83°-97°F
Red = over 97°F / motion detected / tamper
switch triggered
Parameter 7: Use it to choose between LED
indicator modes.
Mode 1 = LED indicator is turned off (no
visual notifications).
Mode 2 = temperature indicated with
pulsing light. Motion indicated with flashing
light.
Mode 3 = temperature and motion
indicated with flashing light.
Mode 4 = no indication for temperature,
motion indicated with flashing light.
Values: 1 - 4. Default set to 3.
Size: 1 byte dec.
NOTE: Mode 2 will increase activity and
decrease battery life.
Tamper Switch
Tamper switch is activated whenever
sensor’s cover is removed while the device
is powered up. It will send an alarm
notification as scheduled.
Z-WAVE COMMAND CLASSES
This device requires the following
command classes to be supported and
recognized by your Z-Wave controller:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
WARRANTY
This Limited Warranty applies to physical goods,
and only for physical goods, purchased from
Zooz (the "Physical Goods").
What does this limited warranty cover?
This Limited Warranty covers any defects in
material or workmanship under normal use
according to instructions from the User Manual
during the Warranty Period. Warranty coverage
applies to purchases made from authorized
dealers only. See full list of Zooz distributors
here: getzooz.com/buy
During the Warranty Period, Zooz will repair or
replace, at no charge, products or parts of a
product that prove defective because of
improper material or workmanship, under
normal use and recommended maintenance.
Zooz does not assume the cost of return
shipping for warranty service.
How long does the coverage last?
The Warranty Period for Physical Goods
purchased from Zooz is 12 months from the
date you purchased this product.
What does this limited warranty not cover?
This Limited Warranty does not cover any
problem that is caused by:
- conditions, malfunctions or damage not
resulting from defects in material or
workmanship
- improper handling or installation of the
product
The warranty does not cover purchases from
unauthorized dealers or second-hand sources.
The warranty does not cover return shipping
cost for warranty service.
What do you have to do?
To obtain warranty service, please contact us to
determine the problem and offer a quick
solution for you: [email protected]
You may also get in touch with the reseller of the
product directly to return or replace the product
within 30 days of purchase or within applicable
reseller’s returns period.
IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES
AND AFFILIATES BE LIABLE FOR ANY INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL, OR
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR
LOSS OF PROFITS, REVENUE, OR USE
INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHETHER IN AN ACTION IN CONTRACT, OR
OTHERWISE EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. ZOOZ'S
LIABILITY AND CUSTOMER'S EXCLUSIVE
REMEDY FOR ANY CAUSE OF ACTION ARISING IN
CONNECTION WITH THIS AGREEMENT OR THE
SALE OR USE OF THE PRODUCTS, WHETHER
BASED ON NEGLIGENCE, STRICT LIABILITY,
BREACH OF WARRANTY, BREACH OF
AGREEMENT, OR EQUITABLE PRINCIPLES, IS
EXPRESSLY LIMITED TO, AT ZOOZ'S OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE
PURCHASE PRICE FOR THAT PORTION OF
PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY
KIND ARISING IN CONNECTION WITH THIS
AGREEMENT OR THE SALE OR USE OF
PRODUCTS SHALL BE DEEMED WAIVED UNLESS
MADE IN WRITING WITHIN THIRTY (30) DAYS
FROM ZOOZ'S DELIVERY, OR THE DATE FIXED
FOR DELIVERY IN THE EVENT OF NONDELIVERY.
FCC NOTE
THE MANUFACTURER IS NOT RESPONSIBLE
FOR ANY RADIO OR TV INTERFERENCE CAUSED
BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT. SUCH MODIFICATIONS COULD
VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT. STORE INDOORS WHEN NOT IN
USE. SUITABLE FOR DRY LOCATIONS ONLY. DO
NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC
Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful
interference,
2. This device must accept any interference
received, including interference that may cause
undesired operation.
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used according to instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that
interference will not occur in any given
installation.
If this equipment causes harmful interference to
radio or television reception, the user may try to
correct the interference by taking one or more
of the following measures:
- Reorient or relocate receiving antenna
- Increase the separation between equipment
and receiver
- Connect equipment into a separate outlet or
circuit from receiver
- Consult the dealer or an experienced radio/TV
technician for additional assistance
All brand names displayed are trademarks of
their respective holders.
[c] Zooz 2016
ask@getzooz.com
www.getzooz.com
6B1Z-31UCD_V2
10 11 12 13 14 15 16 17 18

Depending on your Z-Wave gateway's home
automation software capabilities, you may
be able to associate your Z-Wave 4-in-1
sensor in groups with other Z-Wave devices
to schedule scenes and create events.
Zooz 4-in-1 sensor supports Group 1 with up
to five devices for lifeline communication. To
associate the sensor with other devices,
simply put your Z-Wave controller in
Association mode by sending the
appropriate command and put the 4-in-1
sensor in wake-up mode by pressing and
releasing its Z-Wave button.
ADVANCED SETTINGS
Once the 4-in-1 sensor is added to your Z-
Wave network, you are able to monitor the
values reported by the device on your
computer or mobile device.
Please refer to your controller's user guide
for advanced programming instructions as
they are a little different for every software.
Temperature Sensor
Parameter 1: Use this parameter to switch
from Fahrenheit to Celsius scale.
Values: 0 – Celsius. 1 – Fahrenheit (default).
Size: 1 byte dec.
Parameter 2: Use it to set temperature
change to be reported by the sensor.
Values: 1 - 50 (where 1 stands for 0.1 degree
and 50 stands for 5 degrees). Default set to 1
degree (value 10). The sensor will report
new temperature value to the controller
whenever temperature goes 1 degree up or
down.
Size: 1 byte dec.
Humidity Sensor
Reports relative humidity.
Parameter 3: Use it to set humidity
percentage change to be reported by the
sensor.
Values: 1 - 50 where 1 stands for 1% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Light Sensor
Reports light level in percentage (1-100).
Parameter 4: Use it to choose light
percentage change to be reported by the
sensor.
Values: 5 - 50 where 5 stands for 5% and 50
stands for 50%. Default set to 10%.
Size: 1 byte dec.
Motion Sensor
Parameter 5: Use it to set trigger interval -
the time when motion is reported again
after initial trigger.
Values: 1 - 255 where 1 stands for 1 minute
and 255 stands for 255 minutes. Default set
to 3 minutes.
Size: 1 byte dec.
NOTE: Small interval will increase activity
and decrease battery life.
Parameter 6: Use it to adjust PIR sensor
sensitivity.
Values: 1 - 7, where 1 = very high sensitivity
and 7 = very low sensitivity. Default set to 4.
Size: 1 byte dec.
LED notifications
LED indicator will flash every 3 minutes or
whenever you press the Z-Wave button to
indicate temperature level.
How to read LED indicator colors?
Green = under 60°F
Blue = 60°-75°F
Yellow = 75°-83°F
Purple = 83°-97°F
Red = over 97°F / motion detected / tamper
switch triggered
Parameter 7: Use it to choose between LED
indicator modes.
Mode 1 = LED indicator is turned off (no
visual notifications).
Mode 2 = temperature indicated with
pulsing light. Motion indicated with flashing
light.
Mode 3 = temperature and motion
indicated with flashing light.
Mode 4 = no indication for temperature,
motion indicated with flashing light.
Values: 1 - 4. Default set to 3.
Size: 1 byte dec.
NOTE: Mode 2 will increase activity and
decrease battery life.
Tamper Switch
Tamper switch is activated whenever
sensor’s cover is removed while the device
is powered up. It will send an alarm
notification as scheduled.
Z-WAVE COMMAND CLASSES
This device requires the following
command classes to be supported and
recognized by your Z-Wave controller:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
WARRANTY
This Limited Warranty applies to physical goods,
and only for physical goods, purchased from
Zooz (the "Physical Goods").
What does this limited warranty cover?
This Limited Warranty covers any defects in
material or workmanship under normal use
according to instructions from the User Manual
during the Warranty Period. Warranty coverage
applies to purchases made from authorized
dealers only. See full list of Zooz distributors
here: getzooz.com/buy
During the Warranty Period, Zooz will repair or
replace, at no charge, products or parts of a
product that prove defective because of
improper material or workmanship, under
normal use and recommended maintenance.
Zooz does not assume the cost of return
shipping for warranty service.
How long does the coverage last?
The Warranty Period for Physical Goods
purchased from Zooz is 12 months from the
date you purchased this product.
What does this limited warranty not cover?
This Limited Warranty does not cover any
problem that is caused by:
- conditions, malfunctions or damage not
resulting from defects in material or
workmanship
- improper handling or installation of the
product
The warranty does not cover purchases from
unauthorized dealers or second-hand sources.
The warranty does not cover return shipping
cost for warranty service.
What do you have to do?
To obtain warranty service, please contact us to
determine the problem and offer a quick
solution for you: [email protected]
You may also get in touch with the reseller of the
product directly to return or replace the product
within 30 days of purchase or within applicable
reseller’s returns period.
IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES
AND AFFILIATES BE LIABLE FOR ANY INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL, OR
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR
LOSS OF PROFITS, REVENUE, OR USE
INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHETHER IN AN ACTION IN CONTRACT, OR
OTHERWISE EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. ZOOZ'S
LIABILITY AND CUSTOMER'S EXCLUSIVE
REMEDY FOR ANY CAUSE OF ACTION ARISING IN
CONNECTION WITH THIS AGREEMENT OR THE
SALE OR USE OF THE PRODUCTS, WHETHER
BASED ON NEGLIGENCE, STRICT LIABILITY,
BREACH OF WARRANTY, BREACH OF
AGREEMENT, OR EQUITABLE PRINCIPLES, IS
EXPRESSLY LIMITED TO, AT ZOOZ'S OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE
PURCHASE PRICE FOR THAT PORTION OF
PRODUCTS WITH RESPECT TO WHICH
DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY
KIND ARISING IN CONNECTION WITH THIS
AGREEMENT OR THE SALE OR USE OF
PRODUCTS SHALL BE DEEMED WAIVED UNLESS
MADE IN WRITING WITHIN THIRTY (30) DAYS
FROM ZOOZ'S DELIVERY, OR THE DATE FIXED
FOR DELIVERY IN THE EVENT OF NONDELIVERY.
FCC NOTE
THE MANUFACTURER IS NOT RESPONSIBLE
FOR ANY RADIO OR TV INTERFERENCE CAUSED
BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT. SUCH MODIFICATIONS COULD
VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT. STORE INDOORS WHEN NOT IN
USE. SUITABLE FOR DRY LOCATIONS ONLY. DO
NOT IMMERSE IN WATER. NOT FOR USE WHERE
DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC
Rules.
Operation is subject to the following conditions:
1. This device may not cause harmful
interference,
2. This device must accept any interference
received, including interference that may cause
undesired operation.
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used according to instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that
interference will not occur in any given
installation.
If this equipment causes harmful interference to
radio or television reception, the user may try to
correct the interference by taking one or more
of the following measures:
- Reorient or relocate receiving antenna
- Increase the separation between equipment
and receiver
- Connect equipment into a separate outlet or
circuit from receiver
- Consult the dealer or an experienced radio/TV
technician for additional assistance
All brand names displayed are trademarks of
their respective holders.
[c] Zooz 2016
www.getzooz.com
6B1Z-31UCD_V2
10 11 12 13 14 15 16 17 18
Other manuals for ZSE40