ABB 630 series User manual

Relion® Protection and Control
630 series
DNP3 Point List Manual


Document ID: 1MRS756791
Issued: 15.09.2009
Revision: A
Product version: 1.0
© Copyright 2009 ABB. All rights reserved

Copyright
This document and parts thereof must not be reproduced or copied without written
permission from ABB, and the contents thereof must not be imparted to a third
party, nor used for any unauthorized purpose.
The software or hardware described in this document is furnished under a license
and may be used, copied, or disclosed only in accordance with the terms of such
license.
Trademarks
ABB and Relion are registered trademarks of ABB Group. All other brand or
product names mentioned in this document may be trademarks or registered
trademarks of their respective holders.
Warranty
Please inquire about the terms of warranty from your nearest ABB representative.
ABB Oy
Distribution Automation
P.O. Box 699
FI-65101 Vaasa, Finland
Telephone: +358 10 2211
Facsimile: +358 10 22 41094
http://www.abb.com/substationautomation

Disclaimer
The data, examples and diagrams in this manual are included solely for the concept
or product description and are not to be deemed as a statement of guaranteed
properties. All persons responsible for applying the equipment addressed in this
manual must satisfy themselves that each intended application is suitable and
acceptable, including that any applicable safety or other operational requirements
are complied with. In particular, any risks in applications where a system failure and/
or product failure would create a risk for harm to property or persons (including but
not limited to personal injuries or death) shall be the sole responsibility of the
person or entity applying the equipment, and those so responsible are hereby
requested to ensure that all measures are taken to exclude or mitigate such risks.
This document has been carefully checked by ABB but deviations cannot be
completely ruled out. In case any errors are detected, the reader is kindly requested
to notify the manufacturer. Other than under explicit contractual commitments, in
no event shall ABB be responsible or liable for any loss or damage resulting from
the use of this manual or the application of the equipment.

Conformity
This product complies with the directive of the Council of the European
Communities on the approximation of the laws of the Member States relating to
electromagnetic compatibility (EMC Directive 2004/108/EC) and concerning
electrical equipment for use within specified voltage limits (Low-voltage directive
2006/95/EC). This conformity is the result of tests conducted by ABB in
accordance with the product standards EN 50263 and EN 60255-26 for the EMC
directive, and with the product standards EN 60255-6 and EN 60255-27 for the low
voltage directive. The IED is designed in accordance with the international
standards of the IEC 60255 series.

Table of contents
Section 1 Introduction.......................................................................3
This manual........................................................................................3
Intended audience..............................................................................3
Product documentation.......................................................................4
Product documentation set............................................................4
Document revision history.............................................................5
Related documentation..................................................................5
Symbols and conventions...................................................................6
Safety indication symbols..............................................................6
Manual conventions.......................................................................6
Functions, codes and symbols......................................................7
Section 2 DNP3 data mappings.....................................................11
Overview...........................................................................................11
Point list for 630 series IEDs ...........................................................11
Section 3 DNP3 protocol implementation.......................................41
DNP3 device profile..........................................................................41
DNP3 implementation table..............................................................44
Section 4 Glossary.........................................................................49
Table of contents
630 series 1
Point List Manual

2

Section 1 Introduction
1.1 This manual
The point list manual describes the outlook and properties of the data points
specific to the IED. The manual should be used in conjunction with the
corresponding communication protocol manual.
1.2 Intended audience
This manual addresses the communication system engineer or system integrator
responsible for pre-engineering and engineering for communication setup in a
substation from an IED perspective.
The system engineer or system integrator must have a basic knowledge of
communication in protection and control systems and thorough knowledge of the
specific communication protocol.
1MRS756791 A Section 1
Introduction
630 series 3
Point List Manual

1.3 Product documentation
1.3.1 Product documentation set
Planning & purchase
Engineering
Installing
Commissioning
Operation
Maintenance
Decommissioning
deinstalling & disposal
Application manual
Operation manual
Installation manual
Service manual
Engineering manual
Commissioning manual
Communication protocol
manual
Technical manual
Planning & purchase
Engineering
Installing
Commissioning
Operation
Maintenance
Decommissioning
deinstalling & disposal
Planning & purchase
Engineering
Installing
Commissioning
Operation
Maintenance
Decommissioning
deinstalling & disposal
Application manualApplication manual
Operation manualOperation manual
Installation manualInstallation manual
Service manualService manual
Engineering manualEngineering manual
Commissioning manualCommissioning manual
Communication protocol
manual
Communication protocol
manual
Technical manualTechnical manual
en07000220.vsd
IEC07000220 V1 EN
Figure 1: The intended use of manuals in different lifecycles
The engineering manual contains instructions on how to engineer the IEDs using
the different tools in PCM600. The manual provides instructions on how to set up a
PCM600 project and insert IEDs to the project structure. The manual also
recommends a sequence for engineering of protection and control functions, LHMI
functions as well as communication engineering for IEC 61850 and DNP3.
The installation manual contains instructions on how to install the IED. The
manual provides procedures for mechanical and electrical installation. The chapters
are organized in chronological order in which the IED should be installed.
The commissioning manual contains instructions on how to commission the IED.
The manual can also be used by system engineers and maintenance personnel for
assistance during the testing phase. The manual provides procedures for checking
of external circuitry and energizing the IED, parameter setting and configuration as
well as verifying settings by secondary injection. The manual describes the process
Section 1 1MRS756791 A
Introduction
4630 series
Point List Manual

of testing an IED in a substation which is not in service. The chapters are organized
in chronological order in which the IED should be commissioned.
The operation manual contains instructions on how to operate the IED once it has
been commissioned. The manual provides instructions for monitoring, controlling
and setting the IED. The manual also describes how to identify disturbances and
how to view calculated and measured power grid data to determine the cause of a
fault.
The service manual contains instructions on how to service and maintain the IED.
The manual also provides procedures for de-energizing, de-commissioning and
disposal of the IED.
The application manual contains descriptions of preconfigurations. The manual can
be used as a reference for configuring control, protection, measurement, recording
and LED functions. The manual can also be used when creating configurations
according to specific application requirements.
The technical manual contains application and functionality descriptions and lists
function blocks, logic diagrams, input and output signals, setting parameters and
technical data sorted per function. The manual can be used as a technical reference
during the engineering phase, installation and commissioning phase, and during
normal service.
The communication protocol manual describes a communication protocol
supported by the IED. The manual concentrates on vendor-specific implementations.
The point list manual describes the outlook and properties of the data points
specific to the IED. The manual should be used in conjunction with the
corresponding communication protocol manual.
The service manual is not available yet.
1.3.2 Document revision history
Document revision/date Product version History
A/2009.09.15 1.0 First release
Download the latest documents from the ABB web site http://
www.abb.com/substationautomation.
1.3.3 Related documentation
Name of the document Document ID
DNP3 Communication Protocol Manual 1MRS756789
1MRS756791 A Section 1
Introduction
630 series 5
Point List Manual

1.4 Symbols and conventions
1.4.1 Safety indication symbols
The caution icon indicates important information or warning related
to the concept discussed in the text. It might indicate the presence
of a hazard which could result in corruption of software or damage
to equipment or property.
The information icon alerts the reader to important facts and
conditions.
The tip icon indicates advice on, for example, how to design your
project or how to use a certain function.
Although warning hazards are related to personal injury, it should be understood
that operation of damaged equipment could, under certain operational conditions,
result in degraded process performance leading to personal injury or death.
Therefore, comply fully with all warning and caution notices.
1.4.2 Manual conventions
Conventions used in IED manuals. A particular convention may not be used in this
manual.
• Abbreviations and acronyms in this manual are spelled out in Glossary.
Glossary also contains definitions of important terms.
• Push button navigation in the LHMI menu structure is presented by using the
push button icons, for example:
To navigate between the options, use and .
• HMI menu paths are presented in bold, for example:
Select Main menu/Settings.
• LHMI messages are shown in Courier font, for example:
To save the changes in non-volatile memory, select Yes and press .
• Parameter names are shown in italics, for example:
The function can be enabled and disabled with the Operation setting.
• The ^ character in front of an input or output signal name in the function block
symbol given for a function, indicates that the user can set an own signal name
in PCM600.
• The * character after an input or output signal name in the function block
symbol given for a function, indicates that the signal must be connected to
another function block in the application configuration to achieve a valid
application configuration.
Section 1 1MRS756791 A
Introduction
6630 series
Point List Manual

1.4.3 Functions, codes and symbols
Table 1: Functions included in 630 series IEDs
Functionality IEC 61850 IEC 60617 ANSI
Protection
Three-phase non-directional overcurrent,
low stage
PHLPTOC 3I> 51P-1
Three-phase non-directional overcurrent,
high stage
PHHPTOC 3I>> 51P-2
Three-phase non-directional overcurrent,
instantaneous stage
PHIPTOC 3I>>> 50P/51P
Three-phase directional overcurrent, low
stage
DPHLPDOC 3I> → 67-1
Three-phase directional overcurrent, high
stage
DPHHPDOC 3I>> → 67-2
Non-directional earth-fault, low stage EFLPTOC I0> 51N-1
Non-directional earth-fault, high stage EFHPTOC I0>> 51N-2
Non-directional earth-fault, instantaneous
stage
EFIPTOC I0>>> 50N/51N
Directional earth-fault, low stage DEFLPDEF I0> → 67N-1
Directional earth-fault, high stage DEFHPDEF I0>> → 67N-2
Transient/intermittent earth-fault INTRPTEF I0> → IEF 67NIEF
Stabilised restricted earth-fault LREFPNDF dI0Lo> 87NL
High-impedance–based restricted earth-
fault
HREFPDIF dI0Hi> 87NH
Negative-sequence overcurrent NSPTOC I2> 46
Phase reversal PREVPTOC I2>> 46R
Three-phase thermal overload for feeder T1PTTR 3Ith>F 49F
Three-phase thermal overload for
transformers
T2PTTR 3Ith>T 49T
Three-phase thermal overload for motors MPTTR 3Ith>M 49M
Loss-of-load supervision LOFLPTUC 3I< 37
Motor stall protection JAMPTOC Ist> 51LR
Emergency start ESMGAPC ESTART ESTART
Motor start-up supervision STTPMSU Is2t n< 49,66,48,51LR
Negative phase-sequence time
overcurrent protection
MNSPTOC I2>M 46M
Three-phase overvoltage PHPTOV 3U> 59
Three-phase undervoltage PHPTUV 3U< 27
Positive-sequence overvoltage PSPTOV U1> 47O+
Positive-sequence undervoltage PSPTUV U1< 47U+
Negative-sequence overvoltage NSPTOV U2> 47O-
Residual overvoltage ROVPTOV U0> 59G
Table continues on next page
1MRS756791 A Section 1
Introduction
630 series 7
Point List Manual

Functionality IEC 61850 IEC 60617 ANSI
Frequency gradient DAPFRC df/dt> 81R
Overfrequency DAPTOF f> 81O
Underfrequency DAPTUF f< 81U
Load shedding LSHDPFRQ UFLS/R 81LSH
Transformer differential protection for 2-
winding transformers
TR2PTDF 3dI>T 87T
Fault locator SCEFRFLO FLOC 21FL
Distance protection DSTPDIS Z< 21, 21P, 21N
Automatic switch-onto-fault logic CVRSOF SOTF SOTF
Phase discontinuity PDNSPTOC I2/I1> 46PD
Three-phase current inrush detection INRPHAR 3I2f> 68
Circuit-breaker failure CCBRBRF 3I>/I0>BF 51BF/51NBF
Autoreclosing DARREC O → I 79
Tripping logic TRPPTRC I → O 94
Protection-related functions
Local acceleration logic DSTPLAL LAL LAL
Communication logic for residual
overcurrent
RESCPSCH CLN 85N
Scheme communication logic DSOCPSCH CL 85
Current reversal and WEI logic CRWPSCH CLCRW 85CRW
Current reversal and WEI logic for
residual overcurrent
RCRWPSCH CLCRWN 85NCRW
Control
Bay control QCCBAY CBAY CBAY
Interlocking interface SCILO 3 3
Circuit-breaker/disconnector control GNRLCSWI I ↔ O CB/DC I ↔ O CB/DC
Circuit breaker DAXCBR I ↔ O CB I ↔ O CB
Disconnector DAXSWI I ↔ O DC I ↔ O DC
Local/remote switch interface LOCREM R/L R/L
Synchrocheck SYNCRSYN SYNC 25
Supervision and monitoring
Circuit-breaker condition monitoring SSCBR CBCM CBCM
Fuse failure supervision SEQRFUF FUSEF 60
Current-circuit supervision CCRDIF MCS 3I MCS 3I
Trip-circuit supervision TCSSCBR TCS TCM
Generic measured values MVGGIO
Measured value limit supervision MVEXP
Station battery supervision SPVNZBAT U<> U<>
Tap position indication TPOSSLTC TPOSM 84M
Energy monitoring EPDMMTR E E
Table continues on next page
Section 1 1MRS756791 A
Introduction
8630 series
Point List Manual

Functionality IEC 61850 IEC 60617 ANSI
Measurement
Three-phase current CMMXU 3I 3I
Three-phase voltage, phase-to-earth
voltages (RMS)
VPHMMXU 3Upe 3Upe
Three-phase voltage, phase-to-phase
voltages (RMS)
VPPMMXU 3Upp 3Upp
Residual current RESCMMXU I0I0
Residual voltage RESVMMXU U0Vn
Sequence current CSMSQI I1,I2I1,I2
Sequence voltage VSMSQI U1,U2V1,V2
Power monitoring with P, Q, S, power
factor, frequency
PWRMMXU PQf PQf
Metering
Pulse counter for energy metering PCGGIO
Disturbance recorder function
Disturbance recorder DRRDRE DREC DREC
Analog channels 1-10 (samples) A1RADR ACH1 ACH1
Analog channel 11-20 (samples) A2RADR ACH2 ACH2
Analog channel 21-30 (samples) A3RADR ACH3 ACH3
Analog channel 31-40 (calc. val.) A4RADR ACH4 ACH4
Binary channel 1-16 B1RBDR BCH1 BCH1
Binary channel 17-32 B2RBDR BCH2 BCH2
Binary channel 33-48 B3RBDR BCH3 BCH3
Binary channel 49-64 B4RBDR BCH4 BCH4
1MRS756791 A Section 1
Introduction
630 series 9
Point List Manual

10

Section 2 DNP3 data mappings
2.1 Overview
This document describes the DNP3 data points and structures available in
REF630 / REM630 / RET630 Ver. 1.0. The data points are unmapped as a default.
The point lists describe a superset of all data available including the optional
functionalities.
The point tables show all the available DNP3 data points in these IEDs. The DNP3
points can be freely added, removed, reorganized and reconfigured using PCM600.
As a default, the class assignments are Class 0 and Class 3 for binary inputs and
outputs and for double bit indications. The class assignment for analog inputs and
for counters are Class 0 and Class 2. Analog values are provided with default
scalings. The scalings can be freely modified by the user.
This list represents the superset of DNP3 points. The actual set of available points
depends on the product, optional functionalities and configuration.
See the engineering manual and DNP3 communication protocol
manual for more information.
2.2 Point list for 630 series IEDs
Table 2: Signal point list
Function name Signal type Signal name Description
Active Group (ACTVGRP) Binary inputs ACTVGRP.1.GRP1 Setting group 1 is active
ACTVGRP.1.GRP2 Setting group 2 is active
ACTVGRP.1.GRP3 Setting group 3 is active
ACTVGRP.1.GRP4 Setting group 4 is active
Automation bits (AUTOBITS) Binary outputs AUTOBITS.1.CMDBIT1 Command out bit 1
AUTOBITS.1.CMDBIT2 Command out bit 2
AUTOBITS.1.CMDBIT3 Command out bit 3
AUTOBITS.1.CMDBIT4 Command out bit 4
AUTOBITS.1.CMDBIT5 Command out bit 5
AUTOBITS.1.CMDBIT6 Command out bit 6
AUTOBITS.1.CMDBIT7 Command out bit 7
Table continues on next page
1MRS756791 A Section 2
DNP3 data mappings
630 series 11
Point List Manual

Function name Signal type Signal name Description
AUTOBITS.1.CMDBIT8 Command out bit 8
AUTOBITS.1.CMDBIT9 Command out bit 9
AUTOBITS.1.CMDBIT10 Command out bit 10
AUTOBITS.1.CMDBIT11 Command out bit 11
AUTOBITS.1.CMDBIT12 Command out bit 12
AUTOBITS.1.CMDBIT13 Command out bit 13
AUTOBITS.1.CMDBIT14 Command out bit 14
AUTOBITS.1.CMDBIT15 Command out bit 15
AUTOBITS.1.CMDBIT16 Command out bit 16
AUTOBITS.1.CMDBIT17 Command out bit 17
AUTOBITS.1.CMDBIT18 Command out bit 18
AUTOBITS.1.CMDBIT19 Command out bit 19
AUTOBITS.1.CMDBIT20 Command out bit 20
AUTOBITS.1.CMDBIT21 Command out bit 21
AUTOBITS.1.CMDBIT22 Command out bit 22
AUTOBITS.1.CMDBIT23 Command out bit 23
AUTOBITS.1.CMDBIT24 Command out bit 24
AUTOBITS.1.CMDBIT25 Command out bit 25
AUTOBITS.1.CMDBIT26 Command out bit 26
AUTOBITS.1.CMDBIT27 Command out bit 27
AUTOBITS.1.CMDBIT28 Command out bit 28
AUTOBITS.1.CMDBIT29 Command out bit 29
AUTOBITS.1.CMDBIT30 Command out bit 30
AUTOBITS.1.CMDBIT31 Command out bit 31
AUTOBITS.1.CMDBIT32 Command out bit 32
Bool to Int (B16I) Analog inputs B16I.1.OUT Output value
Breaker failure (CCBRBRF) Binary inputs CCBRBRF.1.CB_FAULT_AL Delayed CB failure alarm
CCBRBRF.1.TRBU Back-up trip by breaker failure
protection function
CCBRBRF.1.TRRET Retrip by breaker failure
protection function
Current circuit supervision
(CCRDIF)
Binary inputs CCRDIF.1.FAIL Detection of current circuit
failure
Three-phase current
measurements (CMMXU)
Analog inputs CMMXU.1.I_DB_A Phase A amplitude, magnitude
of reported value
CMMXU.1.I_DB_B Phase B amplitude, magnitude
of reported value
CMMXU.1.I_DB_C Phase C amplitude, magnitude
of reported value
CMMXU.1.I_ANGL_A Phase A angle, instantaneous
value
CMMXU.1.I_ANGL_B Phase B angle, instantaneous
value
Table continues on next page
Section 2 1MRS756791 A
DNP3 data mappings
12 630 series
Point List Manual

Function name Signal type Signal name Description
CMMXU.1.I_ANGL_C Phase C angle, instantaneous
value
Sequence current
measurements (CSMSQI)
Analog inputs CSMSQI.1.I1_DB Positive sequence current
amplitude, reported value
CSMSQI.1.I1_ANGL_INST Positive sequence current
angle, instantaneous value
CSMSQI.1.I2_DB Negative sequence current
amplitude, reported value
CSMSQI.1.I2_ANGL_INST Negative sequence current
angle, instantaneous value
Event counters (CNTGGIO) Counters CNTGGIO.1.VALUE1 Output of counter 1
CNTGGIO.1.VALUE2 Output of counter 2
CNTGGIO.1.VALUE3 Output of counter 3
CNTGGIO.1.VALUE4 Output of counter 4
CNTGGIO.1.VALUE5 Output of counter 5
CNTGGIO.1.VALUE6 Output of counter 6
Power monitoring function with
P, Q, S, power factor
(PWRMMXU)
Analog inputs PWRMMXU.1.P_DB Active Power magnitude of
deadband value
PWRMMXU.1.Q_DB Reactive Power magnitude of
deadband value
PWRMMXU.1.S_DB Apparent Power magnitude of
deadband value
PWRMMXU.1.F_DB System frequency magnitude of
deadband value
PWRMMXU.1.PF_DB Power Factor magnitude of
deadband value
Binary inputs PWRMMXU.1.ILAG Current is lagging voltage
PWRMMXU.1.ILEAD Current is leading voltage
Disturbance report (DRRDRE) Binary inputs DRRDRE.1.RECMADE Disturbance recording made
DRRDRE.1.CLEARED All disturbances in the
disturbance report cleared
DRRDRE.1.DRPOFF Disturbance report function
turned off
DRRDRE.1.Fault number Disturbance fault number
DRRDRE.1.MEMUSED More than 80% of memory used
DRRDRE.RECSTART Disturbance recording started
DNP small disturbance report
(DNPFREC)
Analog inputs DNPFREC.1.Active setting
group
Active setting group
DNPFREC.1.Fault Freq Fault Freq
DNPFREC.1.Fault Location Fault Location
DNPFREC.1.Fault Number Fault Number
DNPFREC.1.Fault Type Fault Type
DNPFREC.1.No of faults in IED No of faults in IED
DNPFREC.1.Trig Signal Id Trig Signal Id
Table continues on next page
1MRS756791 A Section 2
DNP3 data mappings
630 series 13
Point List Manual

Function name Signal type Signal name Description
DNPFREC.1.Trigger Day Trigger Day
DNPFREC.1.Trigger Hour Trigger Hour
DNPFREC.1.Trigger Millisecond Trigger Millisecond
DNPFREC.1.Trigger Minute Trigger Minute
DNPFREC.1.Trigger Month Trigger Month
DNPFREC.1.Trigger Second Trigger Second
DNPFREC.1.Trigger Year Trigger Year
DNPFREC.1.Sig1 Fault Angle Fault Angle
DNPFREC.1.Sig1 Fault
Magnitude
Fault Magnitude
DNPFREC.1.Sig1 Prefault
Angle
Prefault Angle
DNPFREC.1.Sig1 Prefault
Magnitude
Prefault Magnitude
DNPFREC.1.Sig2 Fault Angle Fault Angle
DNPFREC.1.Sig2 Fault
Magnitude
Fault Magnitude
DNPFREC.1.Sig2 Prefault
Angle
Prefault Angle
DNPFREC.1.Sig2 Prefault
Magnitude
Prefault Magnitude
DNPFREC.1.Sig3 Fault Angle Fault Angle
DNPFREC.1.Sig3 Fault
Magnitude
Fault Magnitude
DNPFREC.1.Sig3 Prefault
Angle
Prefault Angle
DNPFREC.1.Sig3 Prefault
Magnitude
Prefault Magnitude
DNPFREC.1.Sig4 Fault Angle Fault Angle
DNPFREC.1.Sig4 Fault
Magnitude
Fault Magnitude
DNPFREC.1.Sig4 Prefault
Angle
Prefault Angle
DNPFREC.1.Sig4 Prefault
Magnitude
Prefault Magnitude
DNPFREC.1.Sig5 Fault Angle Fault Angle
DNPFREC.1.Sig5 Fault
Magnitude
Fault Magnitude
DNPFREC.1.Sig5 Prefault
Angle
Prefault Angle
DNPFREC.1.Sig5 Prefault
Magnitude
Prefault Magnitude
DNPFREC.1.Sig6 Fault Angle Fault Angle
DNPFREC.1.Sig6 Fault
Magnitude
Fault Magnitude
Table continues on next page
Section 2 1MRS756791 A
DNP3 data mappings
14 630 series
Point List Manual
Other manuals for 630 series
2
Table of contents
Other ABB Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

ProMinent
ProMinent OZONFILT OZMa 1 A operating instructions

Harman
Harman JBL LS60 Technical manual

MUSASHI ENGINEERING
MUSASHI ENGINEERING SHOTMASTER QX Series SHOTMASTER SX Series instruction manual

Gebhardt Anlagentechnik
Gebhardt Anlagentechnik BBF6 Translation of the original operating manual

Trident
Trident AirPrime Series Installation and operation guide

Teledyne
Teledyne 2151P Installation and operation guide