Accuride SENSEON PLUS User manual

SENSEON PLUS
INSTALLATION GUIDE
senseonsecure.com

2SENSEON PLUS INSTALLATION GUIDE
INSTALLATION GUIDE
TABLE OF CONTENTS
Contents........................................................................ 2
Components Overview................................................ 3
Reader ........................................................................... 4
Controller...................................................................... 6
Hub................................................................................ 7
Electronic Locks ........................................................... 8
Cables & Connections.................................................
Power Supply...............................................................

SENSEON PLUS INSTALLATION GUIDE 3
Components Overview
Handheld Programmer
Running on proprietary
software, our Handheld
Programmer allows you
to program enhanced
security configuration
and download audit
trail data from the
Senseon Plus System.
9
Proximity Reader
Senseon Readers
require just a tap of a
wristband, tag, fob, or
key card to send the
unlock signal through
the system.
1
7Power Supply Adapter
The Adapter channels
power from the Power
Supply to Hubs across the
Senseon Plus System.
6Power Supply
(Not Shown)
The Power Supply
provides power for the
Senseon Plus System.
Controller
The brain of the
Senseon Plus system,
the Controller stores
system settings and all
system activity.
2 3
The Hub facilitates
two-way communication
between the Controller
and the locks while
providing power from
the power supply.
Hub
4Electronic Locks
The E-Locks lock and
unlock openings
connected to the
Senseon Plus System.
8Link Extender
The Link Extender
provides additional
length between Hub
cables should one be
too short.
5Magnetic Connector
The Magnetic
Connector connects the
Handheld Programmer
to the rest of a Senseon
Plus System. There are
two connectors:
(A) Programming Side
(B) Cabinet Side.
12
3
4
5A
5B
7
9
8

4SENSEON PLUS INSTALLATION GUIDE
Reader
The Senseon Plus Reader scans user/administrator cards, fobs, or other RFID access credentials. You
can mount a Reader in a variety of locations. These include a cabinet's outside surface, subsurface, or
a surrounding panel or wall. Determine where you want users to scan cards for access beforehand.
(For programming information, see Senseon Plus Programming Guide.)
Mounting Orientations
There are two basic reader mounting orientations: surface and subsurface.
Surface Mounting
You can mount a Reader on the outside of the cabinet surface or a nearby panel or wall. You must
surface mount a Reader if your cabinet has a metal surface as scans will not penetrate metal.
(unless perforated).
You can mount a Senseon Plus Reader on various
locations of a cabinet surface. The above image
highlights example areas.
Optional mounting points for surface installation
of a Reader.
1

SENSEON PLUS INSTALLATION GUIDE 5
Subsurface Mounting
You can mount a Senseon Plus Reader underneath a cabinet surface if the surface is not metallic.
You may use the center or the edge of a cabinet as a reference for the location.
NOTE!
Material composition, such as wood or stone, may impact the Reader's signal strength. It's
recommended a subsurface-mounted Reader be under a surface 1″ thick or less. Always test
scan a Reader in a planned location before you mount it in place. Consider a visual identifier on a
subsurface-mounted Reader to help a user know where to scan.
A Senseon Plus Reader Mount in a vertical
arrangement. Mount a Reader via the Reader
Mount seen here. You can remove the vertical
Reader Mount’s detachable side tabs, or keep
them in place.
Reader Mount in a horizontal arrangement with
detachable tabs still connected. As with a vertical
arrangement, you can remove the vertical Reader
Mount’s detachable side tabs, or keep them in place.
The dimensions of a VERTICALLY MOUNTED
Senseon Plus Reader. Make sure the cabinet
surface your Reader signals through is no
The dimensions of a HORIZONTALLY MOUNTED
Senseon Plus Reader. Make sure the cabinet surface
3.33" MIN
(84.6 mm)
3.33" MIN
(84.6 mm)
1.82" MIN (46.2 mm)
.80" MIN (20.3 cm)
1" MAX (25.4 cm)
1.82" MIN
(46.2 mm)
.80" MIN (20.3 mm)
1" MAX (25.4 mm)
SIDE VIEW SIDE VIEW
FRONT VIEW
FRONT VIEW

6SENSEON PLUS INSTALLATION GUIDE
Controller
The Controller is the "brain" of the Senseon Plus System and resides inside the cabinet fixture. One
Controller supports up to 10 Hubs You can mount a Controller by screw attachment or adhesive tape
(included). The Controller holds audit trail data and system configurations. You have the option to
connect a Controller to third-party RFID readers.
NOTE!
Clean your cabinet surface prior to placing adhesive tape. Using adhesive tape is a one-time
installation. Any removal will damage the tape.
Senseon Plus Controller dimensions (left) and example of mounting location (right).
An example of a mounting location for a cabinet-side Magnetic Connector.
0.70" (17.8 mm)
3.680" (93.5 mm)
Plug Reader cables
from right-to-left in
that order.
2.180" (55.4 mm)
2

SENSEON PLUS INSTALLATION GUIDE 7
Hub
The Hub is the “heart” of the Senseon Plus System. Hubs connect to each other, to the locks, to the
Power Supply, and the Controller. All connected Hubs distribute power and unlock signals amongst
each other. A Senseon Plus Controller supports up to ten Hubs. You can mount a Hub by screw
attachment or adhesive tape (included).
NOTE!
Clean your cabinet surface prior to placing adhesive tape. Using adhesive tape is a one-time
installation. Any removal will damage the tape. Prior to programming, verify all Hubs are set to
Channel 1. See Senseon Programming Guide for more information.
A A
B B
C C
D D
E E
F F
G G
H H
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
DRAWN
CHK'D
APPV'D
MFG
Q.A
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
TOLERANCES:
LINEAR:
ANGULAR:
FINISH:
DEBURR AND
BREAK SHARP
EDGES
NAME
SIGNATURE
DATE
MATERIAL:
DO NOT SCALE DRAWING
REVISION
TITLE:
DWG NO.
SCALE:1:4
SHEET 1 OF 1
A2
WEIGHT:
Senseon Hub Wire Management 1
6.4" (162.6 mm)
1.15"
(29.2 mm)
Senseon Plus Hub Dimensions Sample placements for Senseon Plus Hubs. Clean a
surface before attaching a Hub with adhesive tape
(included). Examples of placement for Hubs are
circled above.
Optional screw-mounting points for Senseon
Plus Hub
0.475" (12.1 mm)
3

8SENSEON PLUS INSTALLATION GUIDE
Electronic Locks
Senseon Plus electronic locks (e-locks) secure or unlock openings via an electronic signal from the
Hub. A built-in sensor monitors the status of a connected opening. The e-lock reports status, defined
as “secure” or “unsecure,” to the Controller. Senseon Plus systems use B-model e-locks which are
designed specifically for Senseon Plus systems. For more information, see your Senseon E-Lock
Technical Sheet.
NOTE!
Before installing the drawer, make sure you have access to your Senseon Plus e-lock's manual
override lever.
Integrated E-Lock & Drawer Slides
An example of an installed Senseon Plus
integrated undermount e-lock An example of
a Senseon Plus 3135EL integrated undermount
e-lock installed within a cabinet.
A Senseon Plus integrated 38EL e-lock for
traditional sidemount drawers.
An example of a Senseon Plus integrated
sidemount e-lock connected to a Hub. Notice
the connection on the right side of the Hub. A
Lock Terminator is required for any Hub slot not
connected to an e-lock.
Access to
manual override 3" (76.2mm)
minimum
4

SENSEON PLUS INSTALLATION GUIDE 9
10EL Standalone E-Locks
An example of a Senseon Plus
standalone 10EL SURFACE-
MOUNTED on a vertical partition
within a FRAMELESS cabinet.
An example of a Senseon Plus standalone 10EL
SURFACE MOUNTED on a horizontal partition
within a FRAMELESS cabinet.
An example of a Senseon Plus standalone 10EL
SURFACE-MOUNTED mounted within a FACE
FRAME cabinet.
An example of a cable route
between a Senseon Plus Hub and
a 10EL.
MOUNTING
BLOCK
ROUTED ALONG
SIDE PANEL - NO
TOP PANEL NEEDED
PARTITION- MAY RUN
TO BACK PANEL OF
CABINET IF DESIRED
3" MIN
(76 mm)
3" MIN
(76 mm)
2 1/2" MIN
(64 mm)
3 1/2" MIN
(89 mm)
PARTITION-
MAY RUN TO
BACK PANEL
OF CABINET IF
DESIRED

10 SENSEON PLUS INSTALLATION GUIDE
An example of a Senseon standalone e-lock
mounted VERTICALLY behind
a drawer.
An example of a Senseon standalone e-lock
mounted HORIZONTALLY behind
a drawer.
Example of Senseon standalone e-lock mounted
horizontally below a drawer (alternate view).
An example of a pair of Senseon standalone e-locks
mounted VERTICALLY behind a
wide drawer.
An example of a Senseon standalone e-lock
mounted HORIZONTALLY AND BELOW a
drawer front.
An example of a Senseon standalone e-lock
mounted HORIZONTALLY AND ABOVE a
drawer front.
CABINET
FRONT
CABINET
FRONT
CABINET
FRONT
CABINET
FRONT
CABINET
FRONT
CABINET
FRONT
CABINET
FRONT
TOP VIEW
SIDE VIEW
SIDE VIEW
SIDE VIEW
SIDE VIEW
3 3/8" MIN
(85.7 mm)
2 1/2" MIN
(63.5 mm)
1/2" MIN
(12.7 mm)
2 1/2" MIN
(63.5 mm)
3 3/8" MIN
(85.7 mm)
1/8" MIN
(3.2 mm)
DRAWER CLOSED
1/2" MIN
(12.7 mm)
3/4" MIN
(19.1 mm)
3/4" MIN
(19.1 mm)

SENSEON PLUS INSTALLATION GUIDE 11
Cables & Connections
An example of Reader-to-Controller and Magnetic Connect-to-Controller connections.
Hub Cable Management
Cable connection points for Hub
Cable Name Cable Color
1 36" Magnetic Connnect to Controller Red
2 12" Handheld to Magnetic Connnect Unmarked
3 36" Reader to Controller Orange
4 12” Reader to Controller Extension Yellow
5 24” Reader to Controller Extension Purple
6 12" Hub to Lock Light Green
7 12” Hub to Lock Extension Brown
8 24” Hub to Lock Extension Silver
9 3" Hub to Lock Terminator Light Blue
10 12” Hub Connect Blue
11 24” Hub Connect Green
12 12” Magnetic Connnect to Controller Extension Gold
13 24” Magnetic Connnect to Controller Extension Dark Red
Reader-to-
Contoller Cable
Magnetic Connect-to-
Controller Cable
Reader Connection Point
on the Controller. Insert
your rst Reader-to-
Controller cable in the slot
circled above.
To Controller
or Hub
Set channel
to "1" with
the provided
screwdriver.
To Power
Supply
Adapter or
Hub
To E-Lock
or Lock
Terminator
To E-Lock
or Lock
Terminator
5

12 SENSEON PLUS INSTALLATION GUIDE
Power Supply
The Power Supply provides the electrical power to run the Senseon Plus System. The power supply
connects to a bottom hub via a power adapter. You can mount a Power Supply by screw attachment
with holder.
Adhesive tape strip
Power Supply
Power Supply Adapter
Hub
Senseon Plus Power Supply
with dimensions.
Senseon Plus Power Supply Adapter with
adhesive tape (included) placed.
An example of placement for a Senseon Plus Power Supply and Adapter in relation to the Hub. The Power
Supply can be mounted on any surface of the cabinet. The example shows the Power Supply mounted
beneath the bottom panel of the cabinet. Other possible positions inside the cabinet are on the back panel,
on top of the bottom panel, on a side panel or partition, or anywhere inside a toe kick (as shown). You can
mount the Power Supply on a cabinet surface or through-panel.
88.9
31
2
"
HOLDER
TOE KICK AREA
7/64"
(2.78 mm)
1"
(25.4 mm)
1"
(25.4 mm)
6 33/64"
(165.4 mm)
4 19/32"
(116.5 mm) 8X DRILL
6

SENSEON PLUS INSTALLATION GUIDE 13
NOTE!
Clean your cabinet surface prior to placing adhesive tape. Using adhesive tape is a one-time
installation. Any removal will damage the tape.
In case of excess cable length,
fold extra length within cable
clips.
Suggested cable access hole
placement for a Senseon Plus
Hub mounted vertically onto the
rear of a cabinet.
Suggested cable access
hole placement for a
Senseon Plus Hub mounted
horizontally (flat) onto a
cabinet partition.
Cable connection point on a
Senseon e-lock. Senseon e-locks
use locking connectors. Always
press down on the connector tab
before removal.
Senseon Plus systems offer
two choices of organizer clips.
Left shows a clip-on option for
smaller cables. Circled right is an
option for larger cables.
An example arrangement of
spacing and placement for
cable clips along a corner.
6"-7"
[15.24cm-17.78cm]
1"-2"
[2.54cm-5.08cm]
1"-2"
[2.54cm-5.08cm]
2 1/4"
(57.2 mm)
1 3/10"
(33.02 mm)
"click"

Accuride International, Inc.
Shoemaker Avenue
Santa Fe Springs, CA 6
© Accuride International, Inc.
senseonsecure.com
Table of contents