manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Actisense
  6. •
  7. Cables And Connectors
  8. •
  9. Actisense QNB-1 User manual

Actisense QNB-1 User manual

This manual suits for next models

1

Other Actisense Cables And Connectors manuals

Actisense OPTO-4 User manual

Actisense

Actisense OPTO-4 User manual

Actisense NMEA 0183 Manual

Actisense

Actisense NMEA 0183 Manual

Actisense PRO-BUF-2 User manual

Actisense

Actisense PRO-BUF-2 User manual

Popular Cables And Connectors manuals by other brands

StarTech.com ST124HD20 quick start guide

StarTech.com

StarTech.com ST124HD20 quick start guide

Philips SWV4543S/10 Features

Philips

Philips SWV4543S/10 Features

Larson Electronics 10-50C instruction manual

Larson Electronics

Larson Electronics 10-50C instruction manual

Grip MEK-PM Assembly and operating manual

Grip

Grip MEK-PM Assembly and operating manual

Ultra Products Travel Pack #3 ULT31436 Specifications

Ultra Products

Ultra Products Travel Pack #3 ULT31436 Specifications

Surpass QCH-F Operation manual

Surpass

Surpass QCH-F Operation manual

Philips SWA6310 Specifications

Philips

Philips SWA6310 Specifications

StarTech.com CRJ4550PK quick start guide

StarTech.com

StarTech.com CRJ4550PK quick start guide

Nohau EMUL-IP2K-PC user guide

Nohau

Nohau EMUL-IP2K-PC user guide

Foxun SX-SP144E-HD4K2K operating instructions

Foxun

Foxun SX-SP144E-HD4K2K operating instructions

Philips SWA3305W Specifications

Philips

Philips SWA3305W Specifications

opticis Stretch DVIM1-1P0x user manual

opticis

opticis Stretch DVIM1-1P0x user manual

Volkswagen VAS 6558A operating manual

Volkswagen

Volkswagen VAS 6558A operating manual

NEXIBO N-13 user manual

NEXIBO

NEXIBO N-13 user manual

CYP PU-1H3HBTL Operation manual

CYP

CYP PU-1H3HBTL Operation manual

Allen-Bradley 1784-u2dhp installation instructions

Allen-Bradley

Allen-Bradley 1784-u2dhp installation instructions

Global Caché Flex Link Blaster quick start

Global Caché

Global Caché Flex Link Blaster quick start

Hauppauge USB-Live2 Quick installation guide

Hauppauge

Hauppauge USB-Live2 Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Technical Accuracy
To the best of our knowledge the information contained in this document
was correct at the time it was produced. Active Research Ltd cannot accept
liability for any inaccuracies or omissions.
The products described in this manual and the specications thereof may be
changed without prior notice. Active Research Ltd cannot accept any liability
for differences between the product and this document. To check for updated
information and specications please check actisense.com.
Active Research Ltd will not be liable for infringement of copyright, industrial
property rights, or other rights of a third party caused by the use of
information or drawings described in this manual.
Product Guarantee
This product comes with a three year ‘return to base’ guarantee. If you
suspect that the unit is faulty please refer to the Troubleshooting Section of
the User Manual before contacting support.
It is a requirement of the guarantee that all installations of electronic
equipment follow the NMEA 0400 specication. Any connection to a battery
or power supply must meet the mandatory essential safety requirements that
may be imposed by local regulatory agencies.
Actisense products are intended for use in a marine environment, primarily for
below deck use. If a product is to be used in a more severe environment, such
use may be considered misuse under the Active Research Ltd guarantee.
Important Notices
The device to which this manual relates complies with the Electromagnetic
Compatibility requirements according to EN60945. The unit should always
be used in conjunction with appropriately approved, shielded cable and
connectors as per NMEA 0400 to ensure compliance. A declaration of
conformity is available for download at www.actisense.com.
If the device to which this manual relates is to be installed within ve metres
of a compass, please refer to the ‘Compass Safe Distance’ section in the
‘Technical Specications’ table available on the Actisense website.
Trademarks and Registered Trademarks
Actisense® and the Actisense logo are registered trademarks of Active
Research Limited (Ltd). All other trademarks are the property of their
respective owners.
The NMEA® name and NMEA logo are copyright held by the NMEA. All uses in
this manual are by permission and no claim on the right to the NMEA name or
logo are made in this manual.
Fair Use Statement
The contents of this manual may not be transferred or copied without the
express written permission of Active Research Ltd.
Copyright © 2017 Active Research Ltd. All rights reserved.
Quick Network Block
Quick Start Guide
QNB-1
Product Registration
Please register your product via the online form at http://actisense.com/
support/prodreg.html.
Your product package includes a unit serial number. The serial number is six
digits long and can be found below the barcode on the label. Your registration
will assist Actisense Support to link your product to your details, simplifying
any future assistance you may require.
Product Disposal
Please dispose of this product in accordance with the WEEE Directive.
The product should be taken to a registered establishment for the disposal of
electronic equipment.
Issue 2.00
21 Harwell Road
Poole
Dorset
UK, BH17 0GE
Tel: +44 (0)1202 746682
Email:[email protected]
Web: www.actisense.com
Introduction & Features
The Actisense QNB-1 provides instrument drops for up to six NMEA 2000
devices offering a exible alternative to multiple T-pieces and reducing the
cost of an NMEA 2000 installation.
The QNB-1 is available in two versions:
The QNB-1-PMW version is tted with six standard NMEA 2000 M12 (Micro-
t) female connectors which allow ‘plug and play’ connections for quick and
easy installation. A Raymarine STNG backbone can be wired to one side of
the QNB-1 to combine standard NMEA 2000 with STNG without the need for
adapter cables.
The QNB-1 version is tted with glands to allow for installation of custom
lengths of cable. This is a great option for ‘mix & matching’ standard NMEA
2000 devices with Raymarine STNG devices.
Both versions are tted with LEDs that provide information during set up
and use to indicate the presence of data, power status, polarity and to show
Powering the QNB-1
For standard operation, connect a power supply or battery with a 10 to 16 volt
output. For extended voltage range operation (16 to 35 volts), the installer
must rst check that all NMEA 2000 devices can support that higher voltage,
as the QNB-1 does not regulate the voltage supplied to it.
Connect the battery positive wire to the ‘+ BATT IN’ terminal and the battery
negative wire to the ‘- BATT IN’ terminal. Use the 4 amp fuses provided for
‘micro’ (lite) backbone cable or the 8 amp fuses for ‘mini’ (heavy) backbone
Connecting NMEA 2000 Devices to the the
QNB-1
NMEA 2000 instruments should be connected to any of the six remaining
spaces available between the power supply and the backbone terminals. See
table in ‘Connecting the backbone cable’ section for pin out. This pin out is
also the same for standard NMEA 2000 and Raymarine’s SeaTalkNG system.
Connecting NMEA 2000 Devices to the the
QNB-1-PMW
Connection of NMEA 2000 devices to the ‘PMW’ variant of the QNB-1 is quick
Mounting the QNB-1
The QNB-1 can be mounted to any at bulkhead using the screw holes located
in each of the four corners of the case. The case has been designed to be
mounted with the glands/connectors on the sides, and not the top and bottom.
Connecting the backbone cable
Using NMEA 2000 approved cabling, install the backbone cable through the
large glands to the terminals furthest from the power supply. A pin out table
is available below. This pin out is the same for standard NMEA 2000 and
LED Behaviour
‘PLRTY’ - illuminates if the BATT IN + and - are the wrong way around
‘PWR’ - indicates presence of power on BATT IN
‘FUSE1’ & ‘FUSE2’ – illuminates when corresponding fuse is good and intact
Wire Colour Connects to
Red NET-S
Black NET-C
White NET-H
Blue NET-L
Bare/green Shield