Adam Equipment AE 402 User manual

Adam Equipment
AE RELAY ACCESSORY
(P.N. 3106611295), Revision A, June 2011)


CAUTION
The relay accessory is designed to allow the AE402
indicator to connect to user equipment. High voltage connections
can be made to the relay PCB.
WARNING! All electrical installation and maintenance
work should be carried out by qualified electricians only.
WARNING! Do not attempt any work with power applied.
Switch off the mains. It is good practice to check (with a voltage
indicating instrument) that the power is off before beginning work.
ANGEROUS VOLTAGES may be present. Only qualified
personal should attempt the connection of the relay to user equipment
ANGEROUS VOLTAGES can cause physical injury and/or
damage to the equip
I

INSTALLATION
The AE 402 indicator is supplied with drivers to control external relays.
The drivers could be used to control a number of different relays
depending upon the users need. The relay drivers are isolated outputs
requiring the use of an external power supply for the relays.
The Relay Accessory is a product to allow quick and convenient
connections to the AE402 for control of external equipment or
indicators.
Connections to the AE042 are made at terminal strip P1:
Within the AE402 the output to drive external relays is on the circuit
board inside the enclosure. To gain access you must remove the 6
screws securing the front to the rear of the case. Pass the wires for the
relays through the grommet on the rear panel. The wires will connect
to the PCB using the terminal strip P1. See the AE402 User manual for
more details.
Any of the 4 relays can be connected to any of the 4 outputs. The
+12Vdc from the relays connects to the Common terminal.

POWER
SUPPLY
Power for the relays can come from a user supplied source. 2
Alternative power input points are provided depending upon the power
the user has available.
Connector VAC is used for 15-25V C or 12-20VAC, 50/60Hz. 500ma.
This input is not sensitive to polarity, either terminal can be used.
If the user has 12V C to 15V C, 500ma available then connector marked
12V c can be used. Be careful with the polarity, using +12 to 12V and
minus voltage to the GN terminal.
Only one power input terminal should be used at one time
OPERATION
uring operation the relays will be active at the same time the
Low/OK/High LE s on the front panel operate and the Zero relay is
activated when the scale is at zero point.
Note the scale must show a small weight before the LOW LE will
activate. See the AE402 User Manual for details of how to set the limits.
User connections to the relays are made using the terminal strips
marked OUT1 to OUT4. The relay active for each LE will depend on the
input connection, Input IN1 controls relay 1, OUT1 for example. But IN1
could be connected to any of the 4 terminals in the AE 402.
CAUTION:
The voltage and current limits of the relay outputs must be less than:
115/230VAC, 1amp or 24V C. 1amp.
Higher currents may damage the circuit board.
The relays are not specified for higher voltages.

1 | P a g e © Adam Equipment Company 010
WARRANTY
STATEMENT
Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed due
to defects in materials or workmanship. Warranty starts from the date of delivery.
uring the warranty period, should any repairs be necessary, the purchaser must inform its
supplier or Adam Equipment Company. The company or its authorised Technician reserves
the right to repair or replace the components at any of its workshops depending on the
severity of the problems. However, any freight involved in sending the faulty units or parts
to the service centre should be borne by the purchaser.
The warranty will cease to operate if the equipment is not returned in the original packaging
and with correct documentation for a claim to be processed. All claims are at the sole
discretion of Adam Equipment.
This warranty does not cover equipment where defects or poor performance is due to
misuse, accidental damage, exposure to radioactive or corrosive materials, negligence, faulty
installation, unauthorised modifications or attempted repair or failure to observe the
requirements and recommendations as given in this User Manual. Additionally rechargeable
batteries (where supplied) are not covered under warranty.
Repairs carried out under the warranty does not extend the warranty period. Components
removed during the warranty repairs become the company property.
The statutory right of the purchaser is not affected by this warranty. The terms of this
warranty is governed by the UK law. For complete details on Warranty Information, see the
terms and conditions of sale available on our web-site.

© Adam Equipment Company 010
Manufacturer’s Declaration of Conformity
This product has been manufactured in accordance with the
harmonized Europea
n standards, following the provisions of the
below stated directives:
Electro Magnetic Compatibility irective 2004/108/EC
Low Voltage irective 2006/95/EC
Adam Equipment Co. Ltd.
Maidstone Road, Kingston,
Milton Keynes, MK10 0BD
United Kingdom
FCC COMPLIANCE
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipme
nt is operated in a commercial environment. The
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation
of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Shielded interconnect cables must be employed with this equipment to insure compliance
with the
pertinent RF emission limits governing this device.
Changes or modifications not expressly approved by Adam Equipment could void the user's authority
to operate the equipment.
WEEE COMPLIANCE
Any Electrical or Electronic Equipment (EEE) comp
onent or assembly of parts intended to be
incorporated into EEE devices as defined by European irective 2002/95/EEC must be recycled or
disposed using techniques that do not introduce hazardous substances
harmful to our health or the
environment as listed
in irective 2002/95/EC or amending legislation. Battery disposal in Landfill
Sites is more regulated since July 2002 by regulation 9 of the Landfill (England and Wales) Regulations
2002 and Hazardous Waste Regulations 2005. Battery recycling has become
topical and the Waste
Electrical and Electronic Equipment (WEEE) Regulations are set to impose targets for recycling.

© Adam Equipment Company 010
ADAM EQUIPMENT is an ISO 9001:2008 certified global company with more than 35 years
experience in the production and sale of electronic weighing equipment.
For a complete listing of all Adam scales and balances visit our website at:
www.adamequipment.com
© Copyright by Adam Equipment Co. Ltd. All rights reserved. No part of this
publication may be reprinted or translated in any form or by any means without the
prior permission of Adam Equipment.
Adam Equipment reserves the right to make changes to the technology, features,
specifications and design of the equipment without notice.
All information contained within this publication is to the best of our knowledge
timely, complete and accurate when issued. However, we are not responsible for
misinterpretations which may result from the reading of this material.
The latest version of this publication can be found on our Website.
Head Office:
Adam Equipment Co. Ltd.
Maidstone Road, Kingston
Milton Keynes,
MK10 0 BD
Tel: +44 (0)1908 274545 Fax:
+44 (0)1908 641339
For regional office worldwide visit www.adamequipment.com
Table of contents
Other Adam Equipment Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

OHAUS
OHAUS T31P quick start guide

Locus Solutions
Locus Solutions GO Real-Time 3G user manual

SEW-Eurodrive
SEW-Eurodrive Vibration SmartCheck user manual

Mesalabs
Mesalabs 90XL user guide

WATANABE
WATANABE WPMZ-5 Quick instruction manual

HB Ross Manufacturing Co.
HB Ross Manufacturing Co. ACVGD ROSS METER user manual