Front Panel LTPH-TP-1001-02, Issue 2
6 February 28, 2001 H2TU-C-388 List 3E
Table 2 lists the front-panel display messages. The display reports the code of a pertinent alarm, loopback, or
diagnostic message and, in some cases, is followed by a second message that modifies the first message with a
value or current configuration setting.
Table 2. Front-Panel Display Messages
Message Full Name Description
ALARM MESSAGES
ACO Alarm Cutoff A system alarm has occurred and has been retired to an ACO
condition by pressing the SEL button on the H2TU-C front panel.
ALRM Alarm Condition Exists A system alarm condition is in effect.
DBER DS1 Bit Error Rate A system DS1 BER alarm is in effect and remains in effect until
cleared.
HBER HDSL2 Block Error Rate A system HDSL2 Block Error Rate alarm is in effect.
LA Loop Attenuation Indicates that the attenuation on the HDSL2 loop has exceeded the
maximum threshold value.
LAIS Line Alarm Indication Signal Indicates an AIS (all ones) pattern is being received or transmitted
at the H2TU-C DS1 input or output ports.
LLOS Local Loss of Signal Indicates that no signal is detected at the DSX-1 input to the
H2TU-C. Causes a system alarm.
LOSW Loss of Sync Word Indicates that the HDSL2 loop has lost synchronization.
MAL Margin Alarm The margin on HDSL2 loop has dropped below the threshold
(0 to 15 dB) as set by the operator.
PWR FEED GND Power Feed Ground The HDSL2 loop is grounded.
PWR FEED OPEN Power Feed Open Indicates a line power open condition.
PWR FEED SHRT Power Feed Short Indicates a short between the Tip and Ring of the HDSL2 pair.
PRMF Performance Report Messaging -
Far End H2TU-R PRM-FE BER threshold has been exceeded.
PRMN Performance Report Messaging -
Near End H2TU-R PRM-NE BER threshold has been exceeded.
RAIS Remote Alarm Indication Signal Indicates an AIS (all ones) pattern is being received or transmitted
at the H2TU-R DS1 input or output ports.
RLOS Remote Loss of Signal Indicates that no signal is detected at the DS1 input to the H2TU-R.
Causes a system alarm.
RRAI Remote RAI—Remote Alarm
Indication at the H2TU-R Net signal
has errors.)
Indicates an RAI alarm (yellow LED) from the CPE with errors from
the line unit or network.
SPNnSpan Number Accompanies the LOSW alarm and identifies the span where the
LOSW alarm occurred.
TRCI Transmit RAI-CI—Remote Alarm
Indication at the H2TU-R (Net signal
does not have errors.)
Upon reception of an RAI (yellow LED) from the CPE, the H2TU-R
sends RAI-CI towards the network if the network signal received at
the H2TU-R is clear. If the network signal is impaired (LOS, AIS, or
LOF), then the RAI is passed on to the network unaltered.
TUC Transmission Unit Central Office Accompanies the DBER, HBER, MAL, and LA alarm and indicates
that the alarm has occurred at the H2TU-C central office unit.
TUR Transmission Unit Remote End Accompanies the DBER, HBER, MAL, and LA alarm and indicates
that the alarm has occurred at the H2TU-R remote unit.