ADC Gas Electric Steam AD-26 User manual

PHASE 5
COIN
USER’S MANUAL
American Dryer Corporation
88CurrantRoad
FallRiverMA02720-4781USA
Telephone:+1 (508) 678-9000 / Fax:+1 (508) 678-9447
e-mail:techsupport@amdry.com
www.amdry.com
ADC Part No. 112146-56

Retain This Manual In ASafe Place For
Future Reference
Pleaseread thismanualcarefully tothoroughlyfamiliarize yourselfwiththe Phase5 Coincomputer system
features, operational instructions, and programming characteristics. This manual contains important
informationonhow touse ALLthefeatures ofyournew ADCdryerin thesafestand fastestway.
AmericanDryerCorporationproductsembodyadvancedconcepts inengineering,design, andsafety. If
thisproductisproperly maintained,itwillprovidemany yearsofsafe,efficient,and troublefreeoperation.
Wehavetriedtomake thismanualascompleteaspossibleand hopeyouwillfindituseful. ADCreservesthe
rightto makechanges from timeto time,without noticeor obligation, inprices, specifications,colors, and
material,andtochange ordiscontinuemodels.
Proposition 65
Use of this product could expose you to substances
from fuel combustion that contain chemicals known
to the State of California to cause cancer, birth defects
and other reproductive harm.
▲ WARNING
!
“IMPORTANTNOTETOPURCHASER”
Information must be obtained from your local gas supplier on the
instructionstobe followedifthe usersmellsgas. These instructions
mustbe postedina prominentlocationnear thedryer.

Table Of Contents
SECTION I
INTRODUCTION.......................................................................................................4
Phase5 CoinMicroprocessor Controller(Computer) Features.......................................................... 4
SECTION II
L.E.D. DISPLAY AND CODES................................................................................. 8
SECTION III
OPERATING INSTRUCTIONS.............................................................................10
A. TimedMode............................................................................................................................. 10
B. AutomaticMode (Patent No.4,827,627) ................................................................................. 11
C. Free Dry Mode ........................................................................................................................ 12
SECTION IV
PROGRAM SELECTION.......................................................................................13
TemperatureDisplayMode............................................................................................................. 13
RightCoinCount (rCC)/LeftCoinCount(LCC) ............................................................................. 13
AutomaticReviewofProgramLocation .......................................................................................... 14
PL01-Temperature ConversionStatus........................................................................................... 15
Automatic Mode(Auto) Patent No.4,827,627 ............................................................................... 15
Timed Mode(tInE) ......................................................................................................................... 15
Anti-WrinkleProgram(Grd) ........................................................................................................... 16
Buzz/Tone(bUZ) ............................................................................................................................ 16
Free DryMode Cycle (FrEE) ......................................................................................................... 16
CoinMode (Coin) .......................................................................................................................... 17
FlashDisplayStatus (FLS) ............................................................................................................. 17
BadCoin Lockout Status(bCLO) ..................................................................................................17
BadCoin Reset (bCrS) .................................................................................................................. 17
AccumulativeTime(AtIn) ............................................................................................................... 18
AccumulativeCoin(ACOn) ............................................................................................................ 20
RotationalSafe Guard-OPTIONAL (nSEn) .................................................................................. 21
PL02 - Percent Dry (PdrY) ............................................................................................................ 21
PL03- HighTemperature(HI° F) ................................................................................................... 21
PL04- HighCool DownTemperature/Time(HIcd) ......................................................................... 22
PL05 - Low Temperature (LO° F)..................................................................................................22
PL06- LowCool DownTemperature/Time(LOcd)........................................................................ 22
PL07 - Permanent Press (PP° F) .................................................................................................... 22
PL08- PermanentPress CoolDown Temperature/Time (PPCd) .................................................... 22
PL09-Left CoinSlotDenomination (LCdE) .................................................................................. 22
PL10-Right CoinSlotDenomination(rCdE).................................................................................. 23

PL11 - Time ForAmount To Start(tFAS) ....................................................................................... 23
PL12-AmountTo Start(AtSt)....................................................................................................... 23
PL13-MinimumAmountForAdditionalTime(AFAT).................................................................... 23
PL14-MaximumTime ForAutomaticDry(Adrt) ........................................................................... 23
PL15-Anti-WrinkleTiming ............................................................................................................ 24
GuardDelayTime(GdLY) .............................................................................................................. 24
GuardOnTime (Gont).................................................................................................................... 24
PL16-Active GuardTime(AGt) .................................................................................................... 24
PL17 - “A” and “b” Factors ........................................................................................................... 24
SECTION V
PROGRAMMING INSTRUCTIONS ....................................................................25
A. IntroductionToProgramming.................................................................................................... 25
B. Programming(Flowcharts) ........................................................................................................ 26
SECTION VI
PROGRAMMING ....................................................................................................29
A. Temperature DisplayMode....................................................................................................... 29
B. LeftCoinCount........................................................................................................................ 30
C. RightCoinCount ...................................................................................................................... 31
D. ProgramLocation 01(PL01) .................................................................................................... 32
E. ProgramLocation 02(PL02) .................................................................................................... 36
F. ProgramLocation 03(PL03) .................................................................................................... 37
G. ProgramLocation04 (PL04) .................................................................................................... 38
H. ProgramLocation 05(PL05) .................................................................................................... 39
I. ProgramLocation 06(PL06) .................................................................................................... 40
J. ProgramLocation 07(PL07) .................................................................................................... 41
K. ProgramLocation 08(PL08) .................................................................................................... 42
L. ProgramLocation 09(PL09) .................................................................................................... 43
M. ProgramLocation 10(PL10) .................................................................................................... 44
N. ProgramLocation 11(PL11) .................................................................................................... 45
O. ProgramLocation 12(PL12) .................................................................................................... 46
P. ProgramLocation 13(PL13) .................................................................................................... 47
Q. ProgramLocation 14(PL14) .................................................................................................... 48
R. ProgramLocation 15(PL15) .................................................................................................... 49
S. ProgramLocation 16(PL16) andProgram Location17(PL17) ................................................ 50

SECTION VII
FACTORY PRESET PROGRAMS/PARAMETERS..........................................51
A. SingleCoinOnly
For alldryer modelsexceptAD-26/AD-295 andAD-540/WDA-540 ....................................... 52
B. DualCoinOnly
For alldryer modelsexceptAD-26/AD-295 andAD-540/WDA-540 ....................................... 53
C. SingleCoinOnly
Fordryer modelsAD-26/AD-295Only .................................................................................... 54
D. DualCoinOnly
Fordryer modelsAD-26/AD-295Only .................................................................................... 55
SECTION VIII
PHASE 5 COIN SYSTEM DIAGNOSTICS .........................................................56
A. Diagnostic(L.E.D)FailureCodes ............................................................................................. 56
1.“door” .................................................................................................................................. 56
2.“dSFL” ................................................................................................................................56
3.“SEFL” ................................................................................................................................57
4.“Hot” ................................................................................................................................... 57
B. L.E.D.Display Indicators/Dots ................................................................................................. 57
1.HeatCircuit Indicator ........................................................................................................... 57
2.Motor CircuitIndicator ......................................................................................................... 57
C. Phase5 MicroprocessorController(Computer) RelayOutput L.E.D.Indicators........................ 58
1.“DOOR” .............................................................................................................................. 58
2.“HEAT”................................................................................................................................59
3.“MTR”(motor) .................................................................................................................... 59
SECTION IX
PHASE 5 AUTO CYCLE (PATENT NO. 4,827,267)
“A” AND “B” FACTOR PARAMETERS .............................................................60
SECTION X
OPTIONAL 9 VOLT BATTERY BACKUP...........................................................62

4
SECTIONI
INTRODUCTION
The Phase 5 Coin Computer System is a fully programmable, highly sophisticated dryer control system.
American Dryer Corporation has designed the Phase 5 coin microprocessor controller (computer) to be the
most versatile and reliable coin-operated control system available.
To eliminate as many moving parts as possible, ALL Phase 5 coin microprocessor controller (computer)
programming is done through the membrane switch on the front of the control panel. The Program Switch (PS)
that puts microprocessor controller (computer) into the program mode is a single program switch. This program
switch eliminates the possibility of switch failure due to an accumulation of lint or moisture.
Phase5 CoinMicroprocessorController (Computer)Features
AUTOMATICPROGRAMREVIEW
In the program mode, the Phase 5 coin microprocessor controller (computer) will show ALL settings by one (1)
touch of the low temperature keyboard (touch pad) selection.
PROGRAMMABLE
Changes in the programs are made at the temperature keyboard (touch pad) selection and actual programs are
displayed for verification.
ADJUSTABLETIME
Programmable from a minimum of 1 minute to a maximum of 99 minutes in 1 minute increments.
COINACCEPTORDENOMINATIONS
Values of coin acceptors are programmable from a minimum of 1 to a maximum value of 9999 for any U.S. or
foreigncoin denomination.
AMOUNTTOSTART
Programmable from a minimum value 1 to a maximum value of 9999 in increments of one (1).
ACCUMULATIVETIME
This program yields a specific value of time for any coin entry made after the “Amount To Start” has been
inserted.

5
TIME FOR AMOUNT TO START
This program retains the time the owner wishes to vend. The feature allows any additional purchase that is
made to be calculated to the second. There is no calculation necessary by the owner. The Phase 5 coin
microprocessor controller (computer) calculates the vended time.
ACCUMULATIVECOIN
This program selection requires that a specific value of coin(s) be inserted for additional time, programmable for
any minimum amount.
COINCOUNT
The number of coins inserted, including a separate display program for optional dual coin acceptors, can be
viewed through the Phase 5 computer’s light emitting diode (L.E.D.) display.
BADCOIN LOCKOUT
Each coin is monitored. Should someone tamper with the coin acceptor or attempt to insert a foreign object, the
microprocessor controller (computer) will “LOCKOUT” and will not accept any entries until the reset time has
elapsed (approximately 15-seconds). Once the reset time has expired, the microprocessor controller (computer)
will automatically reset itself for the next coin entry.
TEMPERATURE CONVERSION
When the temperature conversion status is changed (i.e. from °F to °C), the Phase 5 coin microprocessor
controller (computer) will automatically convert ALLtemperature related programs/parameters from Fahrenheit
to Celsius and vice versa. The Phase 5 coin microprocessor controller (computer) will perform this conversion
within 1° F (2° C). The programs affected are:
1. Temperature Display Mode
2. Temperature Selections
3. Cool Down Temperatures
DRYINGTEMPERATURES
Any of the three (3) temperature selections (HI/LO/PP) are programmable from a minimum of 100° F to a
maximum of 190°F in ten-degree increments or from a minimum of 38° C to a maximum of 88° C in five-degree
increments. Actual temperature programs are displayed at time of programming for verification.
For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a minimum of
100° F to a maximum of 170° F in ten-degree increments, or from a minimum of 38° C to a maximum of 77° C
in five-degree increments.
For theAD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable from a minimum
of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C to a maximum of 71°
C in five-degree increments.

6
COOLDOWNTIME
ALL three (3) temperature selections are programmable from a minimum of 0 minutes to a maximum of 9
minutes in 1 minute increments.
COOLDOWNTEMPERATURES
In the automatic or free dry modes, the cool down cycle termination is programmable from a minimum of 70° F
to a maximum of 190° F in ten-degree increments or from a minimum of 21° C to a maximum of 88° C in
five-degree increments.
AUTOMATIC MODE (Patent No. 4,827,627)
This program selection uses ADC’s patented Auto-Dry cycle. The microprocessor controller (computer) will
calculate the percent of the dryness and read “donE” when complete. The Phase 5 coin microprocessor
controller (computer) can be programmed to have a maximum time for the “Auto Mode.” TheAutomatic Cycle
(mode) can be used in either the “Free Dry” Mode or the “Coin” Mode.
ANTI-WRINKLE
This program selection helps keep permanent press items wrinkle free when they are not removed from the
dryer promptly at the end of the drying and cooling cycles. TheAnti-Wrinkle program settings are:
1. Guard Delay Time ...................... 1 to 9 minutes
2. Guard On Time........................... 1 to 99-seconds
3. Active Guard Time ..................... 1 to 99 minutes
FREEDRYMODE
In this program selection, the dryer can be started without the insertion of coins by simply pressing any one of the
three (3) temperature selections. When set in the “Free Dry” Mode, the Phase 5 coin microprocessor controller
(computer) can also be programmed to run with anAutomatic Cycle (percent of dryness) or with a Timed Cycle.
If the “Free Dry” program is utilized, the computer’s light emitting diode (L.E.D.) display will cycle back and
forth between “FILL” to “FrEE,” unless otherwise programmed.
L.E.D.FLASHDISPLAY
Programmable to allow the L.E.D. readout to display a choice of “FILL” (no cycle in progress), “Amount To
Start” (i.e., 25¢), or, in the case of free dry, “FrEE.” This program selection also allows the L.E.D. display to
flash back and forth every 2-seconds from “FILL” to “Amount To Start” or, in the case of free dry, from “FILL”
to “FrEE.”
AUDIBLETONE
In this program selection, a tone (buzzer) will sound for each coin inserted, program entry, or at the drying and
cooling cycles for a period of 5-seconds to indicate that the cycle is complete. Additionally, when in the
Anti-Wrinkle program, the tone (buzzer) will sound for 5-seconds at the end of the “Guard On Time.”

7
TEMPERATUREDISPLAY
This program selection enables the temperature in the dryer to be viewed (°F or °C) either while the dryer is off
or running. This service feature shows that the dryer is maintaining the selected temperature.
DIAGNOSTICS
ALL major circuits, including door, microprocessor temperature sensor, heat, and motor circuits are monitored.
There are also indicators installed on the outputs of each relay to easily identify failures, and the door switch has
an indicator installed on the Phase 5 microprocessor controller (computer) to help indicate failure.
AUTOMATICDRYTIME
This program selection allows the dryer to run up to a specific time. During the “AUtO” mode or “FrEE” dry
mode this program is only designed to limit the dryer’s operation during the drying cycle.
ROTATIONALSAFEGUARD(Optional)
This program monitors the rotation of the basket (tumbler). If the basket (tumbler) is not rotating, the Phase 5
coin microprocessor controller (computer) will disable ALLoutputs, an audible tone (buzzer) will sound, and an
error message will be displayed. This program selection can be programmed to be in the inactive mode.
BATTERYBACKUP(Optional)
This feature allows the Phase 5 coin microprocessor controller (computer) to maintain its operating status should
a momentary power interruption occur while the dryer cycle is in progress.

8
SECTIONII
L.E.D. DISPLAYAND CODES
AAutomaticCycle(Slope ProgramFactor)
ACOn AccumulativeCoin
Adrt MaximumAutoDrynessTime
AFAt AmountforAdditionalTime
AGt ActiveAnti-WrinkleGuardTime
AtIn AccumulativeTime
AtSt AmountTo Start
AUtO AutomaticMode (Patent No.4,827,627)
bAutomaticCycle(Heat Loss[offset] Factor)
bCLO BadCoin Lockout
bCrS BadCoin Reset
bUZ Buzzer(Tone)
oCEL DegreeinCelsius
CLCC ClearLeftCoin Count
Coin CoinMode
CrCC ClearRightCoinCount
donE DryingandCoolingCyclesComplete
or
DryerisinAnti-WrinkleCycle
door DoorCircuit isOpen*
dSFL DryerSensorCircuitFailure*
oFAr DegreeinFahrenheit
FILL NoCycle inProgress
FLS FlashDisplayActive
FrEE Free Dry Mode
GdLY Anti-WrinkleDelayTime
Gont Anti-WrinkleOnTime
* Refer to Phase 5 Coin System Diagnostics in Section VIII of this manual for detailed information.
(Continuedon NextPage)

9
Grd Anti-WrinkleProgramActive
HICd HighCoolDown
Hot OverheatingCondition*
LCC LeftCoinCount
LCdE LeftCoinDenomination
LOCd LowCool Down
nbUZ NoBuzzer(Tone)
nFLS NoFlashDisplay
nGrd NoAnti-Wrinkle
nSEn NoRotational SensorSelected
PdrY PercentDry
PL ProgramLocation
PLOC ProgramLocationAutomationReview
PPCd PermanentPress CoolDown
PP°F PermanentPress
PUSH AmountTo StartHas BeenInserted
MakeTemperatureSelection
rCC RightCoinCount
rCdE RightCoinDenomination
SEFL RotationalSensorCircuitFailure*
SEn RotationalSensorSelected
tFAS Time ForAmountToStart
tInE TimedMode
* Refer to Phase 5 Coin System Diagnostics in Section VIII of this manual for detailed information.

10
SECTIONIII
OPERATINGINSTRUCTIONS
NOTE: Unlessotherwise specifiedatthe timeofordering,the Phase5coin microprocessorcontroller
(computer)has beenpreprogrammed bythe factorywith theparametersshown onpage52
andpage53 (forALLdryermodels except AD-26/AD-295andAD-540/WDA-540)and
page 54 andpage55(for dryer models AD-26/AD-295andAD-540/WDA-540 only).
Shouldprogram changes befound necessary,please readthis Phase5 CoinUser’sManual
carefullytothoroughlyfamiliarizeyourselfwiththePhase5coinmicroprocessorcontroller
(computer)programmingcharacteristics.
A. TIMED MODE
1. When turning on power or when no cycle is in progress, the light emitting diode (L.E.D.) display will read
“FILL” and/or “Amount To Start” (“AtSt”).
2. Insert coin(s). Once the correct “AmountTo Start” has been inserted, the L.E.D. display will read “PUSH.”
3. Select temperature by pushing “HI TEMP,” “LO TEMP,” or “PERM PRESS.” The dryer will start and the
L.E.D. display will read the temperature cycle selected and the drying time.
4. The dryer will continue through the drying and cooling cycles, showing time counting downward.
NOTE: If thedoor isopened duringa cycle,boththe heatand motorwill stop. However, thePhase 5
coinmicroprocessorcontroller(computer)will continuetocountdownwardsin time.
Continuationof thecyclewill resumeonlyafter thedoorhas beenclosedand anyone (1)of
thethree (3)temperatureselection buttonsisagain depressed.
5. Upon completion of the drying and cooling cycles, the buzzer (tone) will sound, and the L.E.D. display will
read “donE” for 5-seconds, at which time the dryer will shut off.
NOTE: IftheAnti-WrinkleProgramisactive(“Grd”),the L.E.D.display willremain reading“donE,”
andthePhase 5coinmicroprocessor (computer)willproceedthrough theAnti-Wrinkle
Programuntilthemaximum “GuardOnTime”has expiredor untilthedoorisopened,
whichevercomesfirst. The L.E.D.displaywillread“FILL” and/or“AmountToStart”
(“AtSt”).
NOTE: IftheAnti-WrinkleProgramisnotactive(“nGrd”)theL.E.D. displaywill read“donE”until
themaindoor isopened,at whichtimetheL.E.D. displaywillread “FILL”and/or“AmountTo
Start.”

11
B. AUTOMATIC MODE (PATENT NO. 4,827,627)
1. When turning on power or when no cycle is in progress, the light emitting diode (L.E.D.) display will read
“FILL” and/or “Amount To Start” (“AtSt”).
2. Insert coin(s). Once correct “Amount To Start” has been inserted, the L.E.D. display will read “PUSH.”
3. Select temperature by pushing “HI TEMP,” “LO TEMP,” or “PERM PRESS.” The dryer will start, the
L.E.D. display will read the temperature cycle selected, and the drying time portion of the L.E.D. display
will read “00” and count upward as time elapses.
NOTE: Ifthe dooris opened duringa cycle,both theheat andmotor will stop. However,the Phase5
coinmicroprocessorcontroller(computer)will continuetocountupwardsintime.
Continuationof thecyclewill resumeonlyafter thedoorhas beenclosedand anyone (1)of
thethree (3)temperatureselection buttonsisagain depressed.
4. Once the preprogrammed dryness level and cool down period have been reached or maximum automatic
time has expired, whichever comes first, the buzzer (tone) will sound, and the L.E.D. display will read
“donE” for 5-seconds, at which time the dryer will shut off.
NOTE: IftheAnti-WrinkleProgramisactive(“Grd”),the L.E.D.display willremain reading“donE,”
andthePhase 5coinmicroprocessor controller(computer)will proceedthroughthe
Anti-WrinkleProgramuntil themaximum“GuardOnTime”hasexpiredor doorisopened,
whichevercomesfirst. The L.E.D.willread“FILL” and/or“AmountToStart”(“AtSt”).
NOTE: IftheAnti-WrinkleProgram isnotactive(“nGrd”),theL.E.D.displaywill read“donE”until
themaindoor isopened,at whichtimetheL.E.D. displaywillread “FILL”and/or“AmountTo
Start.”

12
C. FREE DRYMODE
1 When turning on power or when no cycle is in progress, the light emitting diode (L.E.D.) display will read
“FILL” and/or “FrEE.”
2. Select temperature. The dryer will start, the L.E.D. display will read the temperature cycle selected and
the drying time portion of the L.E.D. display will read the temperature cycle selected. The drying time
portion of the L.E.D. drying will read “00” and count upward as time elapses, or the vended time will count
downward, depending on which parameter is programmed.
NOTE: Ifthe dooris opened duringa cycle,both theheat andmotor will stop. However,the Phase5
coinmicroprocessorcontroller(computer)willcontinuetocount thetime,eitherupward or
downward,dependingonwhich parameterisprogrammed. Continuationofthe cyclewill
resumeonly afterthe doorhas beenclosed andany one(1) ofthree (3)temperature selection
buttonsis againdepressed.
3. Once the preprogrammed percent dryness level and cool down period has been reached or maximum
automatic time has expired, whichever comes first, the tone (buzzer) will sound, and the L.E.D. display will
read “donE” for 5-seconds, at which time the dryer will shut off.
NOTE: IftheAnti-WrinkleProgramisactive(“Grd”),the L.E.D.display willremain reading“donE,”
andthePhase 5coinmicroprocessor controller(computer)will proceedthroughthe
Anti-WrinkleProgramuntil themaximum“GuardOnTime”has expiredordoorisopened,
whichevercomesfirst. The L.E.D.displaywillread“FILL” and/or“AmountToStart”
(“AtSt”).
NOTE: IftheAnti-WrinkleProgram isnotactive(“nGrd”),theL.E.D.displaywill read“donE”until
themaindoor isopened,at whichtimetheL.E.D. displaywillread “FILL”and/or“AmountTo
Start.”

13
SECTIONIV
PROGRAMSELECTION
NOTE: Programsare storedinthe Phase5 coinmicroprocessorcontroller (computer)memoryand
arecataloged asProgram Locations(PL).
TEMPERATUREDISPLAYMODE
By closing the Program Switch (PS) located on the back side of the Phase 5 coin microprocessor controller
(computer), the light emitting diode (L.E.D.) display will read the temperature in the dryer in either Fahrenheit
(°F) or Celsius (°C), depending on how the temperature conversion status is in PL01.The temperature display
mode can be activated while the dryer is in the operating cycle, or off. While in the operating cycle, the circuit
indicators are visible for troubleshooting purposes.
NOTE: Thedryer cannotbe startedwhile thePhase5 coinmicroprocessor controller(computer)
ProgramSwitch (PS)isclosed, unlessthe cyclewasalready inprogress.
RIGHTCOINCOUNT(rCC)/LEFTCOINCOUNT(LCC)
The “HI TEMP” key lets the operator review the coin counters. If the operator presses the “HI TEMP” key,
the computer displays “_LCC.” The operator could then press either the “PERM PRESS” key to view the
“Left Coin Count” or the “HI TEMP” key and the computer would display “_rCC.” Again, the operator could
press the “PERM PRESS” key to view the “Right Coin Count.” While displaying the coin count, if the operator
presses the “HI TEMP” key the computer then displays “CxCC” (x = “r” or “L”) to indicate “clearing” the coin
count. The operator then presses the “PERM PRESS” key to clear the coin count or the “HI TEMP” or “LO
TEMP” key to exit without clearing the coin count.

14
AUTOMATICREVIEWOFPROGRAM LOCATION
This selection allows for theAUTOMATIC REVIEW of what the program locations are set (programmed) for,
thereby eliminating the need to go into each and every Program Location (PL) manually for verification. By
closing the Programming Switch (PS) with no cycle in progress, the light emitting diode (L.E.D.) display will
read the temperature in the dryer. Then, by pressing the “LO TEMP” key, the L.E.D. display will read “PLOC”
for 1-second. Then, the Phase 5 coin microprocessor controller (computer) will go into the Automatic Review
Mode, the Program Location numbers (i.e., PL01, PL02, etc.) will not be shown and each parameter (i.e.,
“°FAr,” “tInE,” “Grd,” etc.) will be displayed for approximately 1-second each. TheAutomatic Review can be
stopped/exited at any time by simply pressing the “PERM PRESS” key, at which time the L.E.D. display will
read “0000” for 1-second and then return to the Temperature Display mode.

15
PL01-TEMPERATURE CONVERSIONSTATUS
This program controls whether the temperature related programs will be operated in Fahrenheit (°F) or Celsius
(°C). The programs affected are:
1. Temperature Display Mode
2. Selection Cycling Temperatures
3. Cool Down Temperatures
AUTOMATIC MODE (AUtO)PatentNo.4,827,627
When this parameter (“AUtO”) is selected, the dryer will run for a preset level of dryness (PL02) or until the
programmed automatic maximum time (PL14) has expired.
At the end of the drying cycle, the dryer will go into the cool down cycle for the time period programmed (PL04,
PL06, or PL08) or until the temperature has dropped to the programmed cool down temperature (PL04,
PL06, or PL08).
NOTE: Duetohumidity,atmospheric pressure,percentageofextraction, etc.,thedesired drynesslevel
mayvary. Itis suggestedthat theownerdetermine whichlevel ofdryness(90% to100%) is
bestsuitedforhis/her applicationbyexperimentingwitha fewtestloads.
NOTE: Whenprogramming, touse theAutomaticMode (“AUtO”)(PatentNo.4,827,627),the
followingparameter/programsneedto becheckedand/orchanged accordingly:
PL01 ..............................................“AUtO”
..............................................“FrEE” or “Coin” (coins required to start)
PL02 ..............................................“PdrY” (percent dry from 90% to 100%)
PL14 ..............................................“Adrt” (maximum auto dry time)
PL17 ..............................................“A” and “b” Factors
TIMEDMODE(tInE)
When this parameter is selected (‘tInE”) and the Phase 5 coin microprocessor controller (computer) has been
activated, the dryer will continue to run until the preset time, including the cool down period (PL04, PL06, or
PL08), has elapsed, at which time the dryer will continue to run until the preset time, including the cool down
period (PL04, PL06, or PL08), has elapsed, at which time the dryer will cycle off or go into the optional
Anti-Wrinkle Program.

16
ANTI-WRINKLEPROGRAM(Grd)
This feature can be used in conjunction with any of the three (3) operating modes (Coin Mode, Auto Mode, or
the Free Dry Mode). In this program (“Grd”), when the drying and cooling cycles are completed, the dryer will
shut off, the buzzer (tone) will sound, and the light emitting diode (L.E.D.) display will read “donE.” If the door
is not opened, the Phase 5 coin microprocessor controller (computer) will wait until the “Guard Delay Time”
(PL15) has expired, at which time the clothes will be tumbled (without heat) for the programmed ”Guard On
Time” (PL15). The Phase 5 coin microprocessor controller (computer) will repeat this process until the
programmed “Active Guard Time” (PL16) has expired or until the dryer door is opened, at which time the
L.E.D. display will read “FILL” and/or “Amount To Start” (“AtSt”) or “FILL” and/or “FrEE.”
NOTE: WhenprogrammingtheuseoftheAnti-WrinkleProgram(“Grd”), thefollowingparameter/
programsneed tobechecked and/orchanged accordingly:
PL01 ................................ “Grd”(Anti-WrinkleProgramactive)
................................ “bUZ”or“nbUZ”(buzzer[tone]active/notactive)
PL15 ................................ “GdLY”(guarddelaytime)
................................ “Gont”(guardontime)
PL16 ................................ “AGt”(activeguardtime)
BUZZ/TONE(bUZ)
With theAnti-Wrinkle Program active, the option is available to have the buzzer/tone (“bUZ”) sound for a period
of 5-seconds at the end of each “Guard On Time” cycle, or, no buzzer (“nbUZ”) sound.
FREEDRYMODE(FrEE)
The Phase 5 coin microprocessor controller (computer) can be programmed to run without the insertion of
coins. When the Phase 5 coin microprocessor controller (computer) is in the “FrEE” dry mode, it may be
programmed to run in the “AUtO” (Automatic) Mode or the “tInE” (Timed) Mode.
NOTE: Whenprogramming theuseofthe FreeDryMode(“FrEE”),the followingparameters/
programsneed tobecheckedand/orchanged accordingly;
PL01 ................................ “AUtO”(automatic dryingcycle)or
................................ “tInE”(timeddryingcycle)“FrEE”
PL02* .............................. “PdrY”(percentdry)
PL14* .............................. “Adrt”(maximumautodrytime)
PL17* .............................. “A”and “b”factors
* Needsto beprogrammed onlyifPL01 “AUtO”Cycle is chosen.

17
COINMODE(COIN)
In this program mode (“Coin”), coins are required to start the dryer, even if the Phase 5 coin microprocessor
controller (computer) is set in the Automatic Mode (Patent No. 4,827,627).
NOTE: Whenprogrammingtheuseof theCoinMode,(“Coin”),thefollowing parameter/programs
needto becheckedand/or changedaccordingly:
PL01 ................................ “AUtO”(automaticdryingcycle)or
................................ “tInE”(timeddryingcycle)“FrEE”
PL02* .............................. “PdrY”(percentdry)
PL11 ................................ “tFAS” (timeforamountto start)
PL12 ................................ “AtSt”(amountto start)
PL14* .............................. “Adrt”(maximumautodrytime)
PL17* .............................. “A”and “b”Factors
*Needsto beprogrammed onlyif PL01“AUtO”Cycle ischosen.
FLASHDISPLAYSTATUS(FLS)
When the Phase 5 coin microprocessor controller (computer) is set in this program status (“FLS”) it allows the
light emitting diode (L.E.D.) readout to display “FILL” and/or “FrEE” (no cycle in progress), and/or “Amount To
Start” (PL12) or, in the case of free dry, “FrEE.” The programming allows the L.E.D. readout to flip-flop back
and forth every 2-seconds from “FILL” to “Amount To Start,” or in the case of free dry, from “FILL” to
“FrEE.” If the L.E.D. display is programmed for “No Flash” (“nFLS”), the microprocessor controller (computer)
will then prompt you on whether you would like “FILL” displayed or the “Amount To Start” (“AtSt”).
BADCOIN LOCKOUTSTATUS (bCLO)
In this program status (“bCLO”), each coin entry is monitored. Should someone tamper with the coin acceptor
or attempt to insert a foreign object, the Phase 5 coin microprocessor controller (computer) will “LOCKOUT”
and not accept any entries until the reset time has elapsed (approximately 15-seconds). Once the reset time has
expired, the Phase 5 coin microprocessor controller (computer) will automatically reset itself immediately for the
next entry.
BADCOIN RESET(bCrS)
When set in this program (“bCrS”), the Phase 5 coin microprocessor controller (computer) counts in milliseconds
the amount of time required for a coin entry signal. If someone should tamper with the coin acceptor or attempt
to insert a foreign object, the Phase 5 coin microprocessor controller (computer) will not accept the entry and
will automatically reset itself immediately for the next entry.

18
ACCUMULATIVETIME (AtIn)
(SINGLECOIN)
In this program mode (“AtIn”), each coin inserted has a specific value in time which is determined by the “Time
For Amount To Start” (“tFAS”) program (PL11).
Example No. 1: If the dryer is equipped with a 25¢ coin acceptor and the desired time is 30 minutes, each
additional coin inserted would yield 30 minutes.
Settings: PL09 (LCdE)........................25
PL11 (tFAS) ..........................30
PL12 (AtSt)...........................25
Example No. 2: If the dryer is equipped with a 25¢ coin acceptor and the “AmountTo Start” (“AtSt”) is 50¢
for30minutes, the insertion of each additional coin would yield15minutes. Inthisapplication
the “Time For Amount To Start” (“tFAS”) is determined by a Phase 5 coin microprocessor
controller (computer) calculation. There is no calculation required by the owner.
Formula: (LCdE/AtSt) (tFAS) = Vended Time for “ LCdE” (25¢/50¢) (30) = 15 minutes
Settings: PL09 (LCdE)........................25
PL11 (tFAS) ..........................30
PL12 (AtSt)...........................50
(DUALCOIN)
In the accumulative time (AtIn) mode, when using a dual coin acceptor, once the “Amount To Start” (“AtSt”)
has been inserted, the addition of a coin(s) yields more time. The amount time accumulated for each additional
coin inserted is determined by the “Time For Amount To Start” (“tFAS”) program (PL11).
The “Time ForAmount To Start” (“tFAS”) is determined by a Phase 5 coin microprocessor controller (computer)
calculation of additional amounts installed.
Formula: (LCdE/AtSt) (tFAS) = Vended Time
Example No. 1: Using a 10¢/25¢ dual coin acceptor with the desired “Amount To Start” (“AtSt”) being 25¢
for 15 minutes, each additional 10¢ would yield the following:
Formula: (LCdE/AtSt) (tFAS) = Vended Time for “LCdE” (10¢/25¢) (15 minutes) 6 minutes
Settings: PL09 (LCdE)........................10
PL10 (rCdE) .........................25
PL11 (tFAS) ..........................15
PL12 (AtSt)...........................25
This manual suits for next models
39
Table of contents
Other ADC Dryer manuals
Popular Dryer manuals by other brands

Bosch
Bosch WTWH7579SN Installation and operating instructions

Hotpoint
Hotpoint NBXR333 owner's manual

Bosch
Bosch WTW87566AU Installation and operating instructions

Frigidaire
Frigidaire FDE/FDG647RF operating instructions

Crosley
Crosley CGD126SXQ1 installation instructions

Whirlpool
Whirlpool WED96HEA Use & care guide

American Dryer Corp.
American Dryer Corp. AD-120ES II parts manual

Frigidaire
Frigidaire GLER341CDC0 owner's guide

Household Essentials
Household Essentials Sunline WD-15-7 installation instructions

Whirlpool
Whirlpool CEM2750JQ0 installation guide

Sharp
Sharp KD-NHH8S7GW2-EE user manual

Hoover
Hoover PPV160 Instruction book