LTPH-UM-1161-01 Front Panel
H2TU-C-202 List 3F June 28, 2002 5
Table 2 lists the front-panel display messages. The four-character display reports the code of an alarm, loopback,
or diagnostic message and, in some cases, is followed by a second four-character message that modifies the first
message with a value or current configuration setting.
Table 2. Front-Panel Display Messages
Message Full Name Description
ALARM MESSAGES
ACO Alarm Cutoff A system alarm has occurred, and has been retired to an ACO condition
by pressing the LBK pushbutton on the H2TU-C front panel.
ALRM Alarm Condition Exists A system alarm condition is in effect.
DBER DS1 Bit Error Rate A system DS1 BER alarm is in effect and remains in effect until cleared.
HBER HDSL2 Block Error Rate A system HDSL2 Block Error Rate alarm is in effect.
LA Loop Attenuation Indicates that the attenuation on the HDSL2 loop has exceeded the
maximum threshold value.
LAIS Line Alarm Indication Signal Indicates an AIS (unframed all ones) pattern is being received or
transmitted at the H2TU-C DS1 input or output ports.
LLOS Line (Unit) Loss of Signal Indicates that no signal is detected at the DSX-1 input to the H2TU-C.
Causes a system alarm.
LOSW Loss of Sync Word Indicates that the HDSL2 loop has lost synchronization.
MAL Margin Alarm The margin on HDSL2 loop has dropped below the threshold (0 to 15
dB) as set by the operator.
PWR FEED GND Power Feed Ground The HDSL2 loop is grounded.
PWR FEED OPEN Power Feed Open Indicates a line power open condition.
PWR FEED SHRT Power Feed Short Indicates a short between the Tip and Ring of the HDSL2 pair.
PRMF Performance Report Messaging -
Far End H2TU-R PRM-FE BER threshold has been exceeded.
PRMN Performance Report Messaging -
Near End H2TU-R PRM-NE BER threshold has been exceeded.
RAIS Remote Alarm Indication Signal Indicates an AIS (unframed all ones) pattern is being received or
transmitted at the H2TU-R DS1 input or output ports.
RLOS Remote (Unit) Loss of Signal Indicates that no signal is detected at the DS1 input to the H2TU-R.
Causes a system alarm.
RRAI Remote RAI—Remote Alarm
Indication at the H2TU-R (Net
signal has errors.)
Indicates an RAI alarm (yellow) from the CPE with errors from the line
unit or network.
TRCI Transmit RAI-CI—TX RAI-CI
Indication - Customer Installation
at the H2TU-R (Net signal does not
have errors.)
Upon reception of an RAI (yellow) from the CPE, the H2TU-R sends RAI-CI
toward the network if the network signal received at the H2TU-R is clear. If
the network signal is impaired (LOS, AIS, or Loss of Frame [LOF]), then the
RAI is automatically passed on to the network.
SPNnSpan Number Accompanies the LOSW alarm and identifies the span where the LOSW
alarm occurred.
TUC Transmission Unit Central Office Accompanies the DBER, HBER, MAL, and LA alarm and indicates that the
alarm has occurred at the H2TU-C central office unit.
TUR Transmission Unit Remote End Accompanies the DBER, HBER, MAL, and LA alarm and indicates that the
alarm has occurred at the H2TU-R remote unit.
Continued