  9. ADC HiGain H2TU-C-231 Original operating instructions

ADC HiGain H2TU-C-231 Original operating instructions

HiGain
HiGain
FCC Class A Compliance
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Limited Warranty
Product warranty is determined by your service agreement. Contact your sales representative or
Customer Service for details.
Modifications
Any changes or modifications made to this device that are not expressly approved by ADC DSL
Systems, Inc. voids the user's warranty.
All wiring external to the products should follow the provisions of the current edition of the National
Electrical Code.
Standards Compliance
This equipment has been tested and verified to comply with the applicable sections of the following
standards:
❑GR 63-CORE - Network Equipment-Building System (NEBS) Requirements
❑GR 1089-CORE - Electromagnetic Compatibility and Electrical Safety
❑Binational standard, UL-1950/CSA-C22.2 No. 950-95: Safety of Information Technology
Equipment
Trademark Information
ADC is a registered trademark of ADC Telecommunications, Inc. HiGain is a registered trademark of
PairGain Technologies, Inc. Other product names mentioned in this installation guide are used for
identification purposes only and may be trademarks or registered trademarks of their respective
companies.
Copyright Information
©Copyright 2001 ADC DSL Systems, Inc. All rights reserved. Information contained in this document
is company private to ADC DSL Systems, Inc., and shall not be modified, used, copied, reproduced, or
disclosed in whole or in part without the written consent of ADC.
ADC DSL Systems, Inc.
14402 Franklin Avenue
Tustin, CA 92780-7013
Tel: 714.832.9922
Fax: 714.832.9924
Technical Assistance
800.638.0031
714.730.3222
THE H2TU-C-231 LIST 3E
The H2TU-C-231 List 3E line unit is the Central Office (CO) side of a T1 transmission
system. When the H2TU-C is used in conjunction with a HiGain High-bit-rate Digital
Subscriber Line 2 (HDSL2) remote unit (H2TU-R), the system provides 1.552 Mbps
transmissionon oneunconditioned copperpairoverthefullCarrier ServiceArea(CSA)
range. The CSA includes loops up to 12,000 feet of 24 AWG or 9,000 feet of 26 AWG
wire, including bridged taps.
FEATURES
SPECIFICATIONS
•Front-panel status LED, craft port, and
four-character status display •Payload (PL) or HiGain (HG) loopback source
identification
•Ultra-low wander •Bit Error Rate (BER) alarm option
•Grounded loop detection •Bipolar Violation Transparency (BPVT) option
•Loss of Signal (LOS)/Alarm Indication Signal
(AIS) payload alarm option •Report menu option for downloading status and
performance monitoring data to a file
•Digital Data Service (DDS) latching loopback
option •Maintenance screens for inventory, provisioning,
troubleshooting, and performance monitoring
•Sources sealing current •Performance Report Messaging (SPRM and NPRM)
•Supports the inband 100 loopdown and
100000 loopup commands when the
SmartJack Loopback (LPBK) option is enabled
•HDSL2 span connection to Loop 2 on pins 26 and
27
Operating Temperature -40 °F to +149 °F (-40 °C to +65 °C)
Operating Humidity 5% to 95% non-condensing
HDSL2 Span Voltage 0, -185 Vdc
Mounting 220 mechanics, high-density shelf
HDSL2 Line Rate 1.552 Mbps Overlapped Pulse Amplitude Modulation Transmission
with Interlocking Spectra (OPTIS)
HDSL2 Output +16.8 dBm ±0.5 dB, 135 Ω(0-450 kHz) at CO side
+16.5 dBm ±0.5 dB, 135 Ω(0-350 kHz) at remote side
Maximum Loop Attenuation 35 dB at 196 KHz, 135 Ω
DSX-1 Line Rate 1.544 Mbps ±200 bps
DSX-1 Line Format Alternate Mark Inversion (AMI) or Bipolar with 8-Zero Substitution
(B8ZS)
DSX-1 Frame Format Extended SuperFrame (ESF), SuperFrame (SF), or Unframed (UNFR)
DSX-1 Pulse Output 6 V pk-pk, pre-equalized for 0 to 655 feet of ABAM cable
DSX-1 Input Level +1.5 to -7.5 dB DSX
INSTALLATION
To ensure proper installation of the H2TU-C-231, align the H2TU-C with the
enclosure slot guides and slide the unit in. When the unit is properly seated, the
retaining latch snaps closed.
POWER-UPSEQUENCE
When the H2TU-C powers up, the four-character display illuminates and reports
status messages.
If the H2TU-C is unable to communicate with the H2TU-R, it displays various alarm
and status messages.
If the H2TU-C is able to communicate with the H2TU-R, the following occurs:
1The Status LED flashes red while acquiring the H2TU-R and turns a steady green
when the entire system is operating with no alarms. (The DS1 signal must be
present.)
2The four-character display reports margin (SNR) readings (shouldbe ≥6 dB) and
loop attenuation (should be <35 dB @196 KHz).
3After the system powers up, alarm conditions that exist are reported on the
display. (The H2TU-C reports alarms if no DS1 signal is applied.)
PROVISIONING
After installing the H2TU-C, perform these basic provisioning tasks by accessing the
HiGain HDSL2 logon screen. Refer to the onscreen Help menu for navigational aids.
1Connect a maintenance terminal to the craft port (see front-panel illustration
inside), then press + to refresh the log on screen, if necessary.
2Select the Config menu, Date and Time, then type the date and time.
3Select the Inventory menu, then type in the unit ID numbers.
4Change the settings of any system parameters, if necessary, by selecting the
Config menu, Standard Options or ADC Options. (Configuration options can
also be set from the front panel using the MODE and SEL buttons. See the
“Front-Panel Configuration Options Using MODE and SEL” table inside.)
5Once the H2TU-C is successfully installed and provisioned, access the
Performance or Event Log menu to clear the Performance, Alarm History, or
Event Log screens, or use Master Clear in the Config menu.
Continued
CTRL R
Þ
´,#R¶7c¨
1203507
February 28, 2001
Product: 150-2404-35
CLEI: VACJ1LDE
Document: LTPH-QI-1046-02, Issue 2
IN
3E
BRG
BRG
BRGBRG
LINE
LINE
HiGain
HDSL2
DCE
H2TU-C-231 LIST 3E
LINE UNIT
QUICK INSTALLATION
LOOPBACK TESTING
Initiate loopback testing from the maintenance screen or use the MODE and SEL
pushbuttons. The inband codes below can also be sent by a test set.
For more information about the maintenance screens, refer to the H2TU-C-231 List 3E
technical practice, document number LTPH-TP-1004-xx. Contact Customer Service to
obtain a copy of the practice.
H
D
S
L
2
H
2
T
U
•
C
2
3
1
MODE SEL
OUT
BRG
IN
L
LINE
LINE
BRG
R
S
2
3
2
SETUP
STATUS
Four-character display
List number
Status LED
Displays status, provisioning, and
alarm messages. See tables below
for a list of message descriptions.
Status LED reports the following conditions:
Card-Edge Connector
14
15
16
17
18
19
20
21
22
23
24
25
Tip
DSX-1
DSX-1
In
Out
Ground
Factoryuseonly
Ring
Ground
Tip1
Ring1
39
40
41
42
43
44
45
46
47
48
49
50
-48Vdc
1
2
3
4
5
6
7
8
9
10
11
Fusealarm*
Tip
Ring
KEY KEY
26
27
28
29
30
31
32
33
34
35
36
37
38
12
13
Alarms**
* Fuse alarm is normally floating and at -48 Vdc when activated.
** System minor alarm contacts (pins 20 and 21) are normally open;
they close upon alarm.
Management bus
3E
HiGain
HDSL2
A Customer Remote (CREM)
or Network Local (NLOC)
loopback is in effect.
Green LED Normal operation.
Red LED Fuse alarm.
Flashing Red LED HDSL2 acquisition or
system alarm.
Yellow LED
FlashingYellow LED System is in Armed (ARM)
mode.
Off Line power is off.
MODE and SEL pushbuttons (for manual
setting of system parameters)
DSX-1 test access jacks
Use MODE and SEL to manually modify user options,
initiate loopbacks, and display DSX-1 line parameters.
Connect standard test equipment.
Craft port provisioning
To access all system maintenance, provisioning,
and performance screens, connect a standard
9-pin terminal cable between the serial port on a PC
and the H2TU-C craft port.
1
2
3
4
Press the MODE button for 1 second and release.
The front panel alternately displays the first
system parameter and its current setting.
Press SEL to step through all possible settings for
the displayed parameter.
Press MODE to update the parameter and advance
to the next parameter.
After scrolling through all the parameters, press SEL
to confirm changes when prompted with a CONF NO
message, or press MODE to cancel all changes.
BRG
LINE
Provides non-intrusive bridging jack
access to (IN) and from (OUT) the
HDSL2 span at the DSX-1 interface.
Allows monitoring of the DS1 payloads.
Provides splitting jack access to
(IN) and from (OUT) the HDSL2 span
at the DSX-1 interface.
MaintenanceTerminal Modem Settings
9600 baud
8 data bits
No parity
1 stop bit
Hardware flow control:OFF
Terminal emulation software:VT100
HDSL2 Span
DCE
GNLB Loopback Commands
Loopback Inband Code Description
NLOC 1111000 DSX-1 signal is looped back to the network at the H2TU-C.
NREM 1110000 DSX-1 signal is looped back to the network at the H2TU-R.
SMJK 11000 DSX-1 signal is looped back to the network at the H2TU-R
SmartJack module.
CREM 1111110 DS1 signal from customer is looped back to the customer
at the H2TU-C.
CLOC 1111100 DS1 signal from customer is looped back to the customer
at the H2TU-R.
Loopdown 11100 Deactivates any of the above loopbacks.
Front-Panel Alarm Messages(a)
(a) Front-panel alarm messages are listed in order of priority. ALRM displays prior to any alarm message.
Pressing the SEL button initiates an Alarm Cutoff (ACO) message.
Message Description
PWR FEED SHRT (b)
(b) Message displays repeatedly as long as the alarm condition exists and is not included in the priority order.
A short between the Tip and Ring of the HDSL2 pair.
PWR FEED GND (b) The HDSL2 loop is grounded.
PWR FEED OPEN (b) A line-power open condition.
SPNn-LOSW The HDSL2 loop has lost synchronization. The span closest to the network has highest
priority.
LLOS No signal is detected at the DSX-1 input to the H2TU-C.
RLOS No signal is detected at the DS1 input to the H2TU-R.
LAIS (c)
(c) Does not activate the alarm relay access pins 20 and 21.
Local Alarm Indication Signal.
RAIS (c) Remote Alarm Indication Signal.
TRCI (c) An RAI alarm (yellow LED) from the CPE with an error-free signal from the line unit or
network.
RRAI(c) An RAI alarm (yellow LED) from the Customer Premises Equipment (CPE) with errors
from the line unit or network.
xxx-DBER (c) A system DS1 Bit Error Rate (BER) alarm. (xxx denotes either TUC or TUR.)
PRMF (c) H2TU-R Performance Report Messaging BER threshold exceeded at far end.
PRMN (c) H2TU-R Performance Report Messaging BER threshold exceeded at near end.
xxx-HBER A system HDSL2 Block Error Rate (BER) alarm. (xxx denotes either TUC or TUR.)
xxx-MAL The margin on the HDSL2 loop has dropped below the threshold setting. (xxx denotes
either TUC or TUR.)
xxx-LA The attenuation on the HDSL2 loop has exceeded the maximum threshold value. (xxx
denotes either TUC or TUR.)
To comply with the intrabuilding wiring requirements of
GR-1089 CORE, Section 4.5.9, the shields of the ABAM-type
cables that connect the H2TU-C-231 List 3E DSX-1 output ports
to the cross-connect panel must be grounded at both ends.
Network
Customer
Premises
H2TU-C H2TU-R
TLOS*
NLOC CREM CLOC
1111000 NREM
1110000 1111100
1111110
11000
SMJK
When enabled,TLOS is an automatic loopback
that occurs with an LOS at the remote DS1 input.
*
DS1DSX-1
Front-Panel Diagnostic Messages
Display Code Description (normal operating messages in bold)
A=xx The loop attenuation of the longest (maximum loss) span, measured in dB.
ACQ The multiplexers of the H2TU-C-231 and H2TU-R are trying to establish synchronization.
AnL The multiplexers of the two devices on Span n are trying to establish synchronization with
each other, where nis the number of the span.
ARM Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT? The H2TU-C is not receiving a response from the H2TU-R.
FERR A framing bit error occurred at H2TU-C DSX-1 input.
FLDL Flash download of firmware updates. (Contact Customer Service for update procedures.)
HES H2TU-C HDSL2 loop cyclical redundancy check (CRC) error.
LBPV A local bipolar violation has been received at the DSX-1 input to the H2TU-C.
M=xx Indicates the power of the received HDSL2 signal relative to noise (S/N with respect to
21.5 dB). Any value of 6 dB or greater is adequate for reliable system operation.
MNGD The H2TU-C is under control of the HMU-319 network management unit.
PWR FEED OFF HDSL2 span power is turned off.
PWR FEED ON Indicates that the HDSL2 loop is not grounded or shorted.
SIG The transceivers of the H2TU-C and H2TU-R are trying to establish contact with each
other on Span 1 of the HDSL2 loop.
SnL The transceivers of the two devices on Span nare trying to establish contact with each
other, where nis the number of the span.
Front-Panel Configuration Options Using MODE and SEL
Display Code Description (default values in bold)
EQL Sets the DSX-1 Equalizer to: EXT (replaces the internal equalizer with an external
equalizer), 0 (0 to 132 ft.), 133 (133 to 265 ft.), 266 (266 to 398 ft.), 399 (399 to 532 ft.),
533(533to655ft.).
RLBO Sets the H2TU-R line buildout to 0 dB, -7.5 dB, or 15 dB.
LPBK Enables (ENA) or disables (DIS) SmartJack loopback commands.
FT1 Enables (ENA) or disables (DIS) system response to DDS latching loopback commands
for fractional T1 applications.
SPLB xxxx Configures system for generic (GNLB) or specialinband loopback commands (A2LB, A3LB, A4LB).
PWRF OFF = disables HDSL2 powering; ON = HDSL2 line voltage is -185 Vdc maximum.
HBER 1E-6 or 1E-7 = alarm activates when theHDSL2 BER alarmthreshold exceeds 10-6 or 10-7.
NONE = prevents generation of a system alarm due to BER.
DBER Enables (ENA) or disables (DIS) fixed 24-hour DSX-1 BER alarm threshold.
LBTO Loopback timeout = NONE, 20, 60, 120 minutes.
ALM Enables (ENA) or disables (DIS) alarm indications on pins 20 and 21.
DS1 DSX-1 line code = B8ZS, AMI.
CONV H2TU-R frame format conversion = OFF (framing determined by the DS1 FRMG option),
ACON (autodetection of framing and potential frame conversion at the H2TU-R), or FCON
(autodetection of framing and forced frame format conversion at the H2TU-R).
FRMG DS1 frame formatting = AUTO (auto framing mode) or UNFR (unframed mode).
ALMP Enables system to output an alarm pattern: AIS or LOS.
BPVT Enables (ENA) or disables (DIS) Bipolar Violation Transparency.
NLBP Enables the H2TU-R to transmit either AIS or LOS towards CI for any network loopback.
TLOS Enables (ENA) or disables (DIS) a logic loopback at the H2TU-R when an LOS occurs at its
DS1 input.
RTPV Enables (ENA) or disables (DIS) remote provisioning.
PRM OFF = no enhanced Performance Report Messaging; SPRM = Supplemental PRM;
NPRM = Network PRM; S + N = SPRM + NPRM.
NAIS If ALMP is set to AIS, this option specifies which pattern is sent to the network when a
remote LOS or AIS occurs. CI = AIS-CI sent to the network; AIS = AIS sent to the network.
ROVR Enables (ENA) or disables (DIS) conversion of an ESF DS1 payload from the network with
an embedded RAI pattern to an SF-RAI pattern towards the CI at the H2TU-R. CONV
option must be set to FCON or ACON.
RACI Enables (ENA) or disables (DIS) conversion of a DS1 SF-RAI signal received by the H2TU-R
to an SF-RAI-CI signal towards the network.
Front-Panel System Information Messages (Scroll Mode)(a)
(a) To scroll through system information messages, press the MODE button for 3 or more seconds.
Code Description Code Description
CODE xxxx Line code setting (AMI or B8ZS). LIST xx List number of the H2TU-C-231.
FRM xxxx Frame pattern received from the
DSX-1 (SF, ESF, UNFR). MARG xx Margin threshold (0 to 15 dB).
Default is 5.
LATT xx Loop attenuation (0 to 40 dB).
Default is 32. VER x.xx Software version number.

Other manuals for HiGain H2TU-C-231

7

Other ADC Network Hardware manuals

ADC H4TU-C-231-L1 User manual

ADC

ADC H4TU-C-231-L1 User manual

ADC Double Pair/Line Power HDSL User manual

ADC

ADC Double Pair/Line Power HDSL User manual

ADC HiGain HDSL2 User manual

ADC

ADC HiGain HDSL2 User manual

ADC ComProtect Building Entrance Terminals (BET) User manual

ADC

ADC ComProtect Building Entrance Terminals (BET) User manual

ADC The DSX Value Solution (Japanese) LDX154 User manual

ADC

ADC The DSX Value Solution (Japanese) LDX154 User manual

ADC HiGain H2TU-R-402 List 7A Original operating instructions

ADC

ADC HiGain H2TU-R-402 List 7A Original operating instructions

ADC LoopStar 750 User manual

ADC

ADC LoopStar 750 User manual

ADC HiGain H2TU-C-231 Original operating instructions

ADC

ADC HiGain H2TU-C-231 Original operating instructions

ADC DSX-4R (RZX3) User manual

ADC

ADC DSX-4R (RZX3) User manual

ADC H2TU-C-202 User manual

ADC

ADC H2TU-C-202 User manual

ADC HiGain HRE-420 User manual

ADC

ADC HiGain HRE-420 User manual

ADC OmniReach OFDT-24 User manual

ADC

ADC OmniReach OFDT-24 User manual

ADC HiGain H2TU-C-231 User manual

ADC

ADC HiGain H2TU-C-231 User manual

ADC H2TU-C-388 HiGain Original operating instructions

ADC

ADC H2TU-C-388 HiGain Original operating instructions

ADC WorldDSL UTU-701C User manual

ADC

ADC WorldDSL UTU-701C User manual

ADC Double Pair/Line Power G.SHDSL WorldDSL G.S User manual

ADC

ADC Double Pair/Line Power G.SHDSL WorldDSL G.S User manual

ADC PG-Flex FLL-812 User manual

ADC

ADC PG-Flex FLL-812 User manual

ADC GPRS Support Node GGSN & SGSN WAVE.GSN User manual

ADC

ADC GPRS Support Node GGSN & SGSN WAVE.GSN User manual

ADC HiGain HTC-439 List 2 Test Card User manual

ADC

ADC HiGain HTC-439 List 2 Test Card User manual

ADC Cross-Connect DSXi User manual

ADC

ADC Cross-Connect DSXi User manual

ADC HiGain H2TU-C-319 List 4E User manual

ADC

ADC HiGain H2TU-C-319 List 4E User manual

ADC HIGAIN H2TU-R-402-L7A1 Original operating instructions

ADC

ADC HIGAIN H2TU-R-402-L7A1 Original operating instructions

ADC H2TU-C-202 User manual

ADC

ADC H2TU-C-202 User manual

ADC PG-FlexPlus AMU-912 User manual

ADC

ADC PG-FlexPlus AMU-912 User manual

Popular Network Hardware manuals by other brands

Multitech MultiFRAD FR111 owner's manual

Multitech

Multitech MultiFRAD FR111 owner's manual

HIK VISION TBK-NVR2100 Series quick start guide

HIK VISION

HIK VISION TBK-NVR2100 Series quick start guide

High Sec Labs KM Admin Tool user manual

High Sec Labs

High Sec Labs KM Admin Tool user manual

Q-See QC814 Specifications

Q-See

Q-See QC814 Specifications

HIK VISION iDS-9664NXI-M8/X user manual

HIK VISION

HIK VISION iDS-9664NXI-M8/X user manual

Cisco IronPort C670 quick start guide

Cisco

Cisco IronPort C670 quick start guide

Mazi INVR-0xA user manual

Mazi

Mazi INVR-0xA user manual

OXO JORAN User instruction

OXO

OXO JORAN User instruction

Magma PCI Expansion System P13RR-TEL user manual

Magma

Magma PCI Expansion System P13RR-TEL user manual

Interlogix TruVision 10 user manual

Interlogix

Interlogix TruVision 10 user manual

KE2 Therm Solutions KE2 Evaporator Efficiency quick start guide

KE2 Therm Solutions

KE2 Therm Solutions KE2 Evaporator Efficiency quick start guide

Speco N8 user guide

Speco

Speco N8 user guide

MSI MS-S0391 manual

MSI

MSI MS-S0391 manual

Caltta ZXIMCU P300 Operation manual

Caltta

Caltta ZXIMCU P300 Operation manual

BridgeWave AR60X installation manual

BridgeWave

BridgeWave AR60X installation manual

PairGain T1L2BZ0A manual

PairGain

PairGain T1L2BZ0A manual

NETGEAR AirCard quick start guide

NETGEAR

NETGEAR AirCard quick start guide

Emerson dixell quick start guide

Emerson

Emerson dixell quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.