Front Panel LTPH-UM-1214-02
6 July 21, 2003 H2TU-C-388 List 7F
LOOPBACK MESSAGES
CLOC Customer Local Loopback Signal from customer is looped back to the customer at the H2TU-R.
COLB Central Office Loopback Dual loopback at the H2TU-C.
CREM Customer Remote Loopback Signal from customer is looped back to the customer at H2TU-C.
NLOC Network Local Loopback DSX-1 signal is looped back to the network at the H2TU-C.
NREM Network Remote Loopback DSX-1 signal is looped back to the network at the H2TU-R.
RULB Remote Unit Loopback Dual loopback at the H2TU-R.
SMJK Remote SmartJack Loopback DSX-1 signal is looped back to the network at the H2TU-R SmartJack
module.
DIAGNOSTIC MESSAGES
A = xx Maximum Loop Attenuation The Attenuation (A) message appears followed by xx, where xx is the
loop attenuation of the longest (maximum loss) span, measured in dB.
ACQ Acquisition The multiplexers of the H2TU-C and H2TU-R (or the H2TU-C and first
regenerator) are trying to establish synchronization over the HDSL2 loop
of Span 1.
ARM HiGain System Armed Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT? No Response from H2TU-R The H2TU-C receives no response from the H2TU-R and all HDSL2 loop
conditions are normal. Therefore, the integrity of the H2TU-R or the
HDSL2 loop is questionable.
BAD RGND H2TU-R Frame Ground Signal The H2TU-R does not have a frame ground connection.
FERR Framing Bit Error Occurred Framing bit error has occurred at H2TU-C DSX-1 input.
HES HDSL2 CRC Error H2TU-C HDSL2 Loop Cyclical Redundancy Check (CRC) error.
LBPV Local Bipolar Violation A bipolar violation has been received at the DSX-1 input to the H2TU-C.
M=xx HDSL2 Loop Margin Indicates the power of the received HDSL2 signal relative to noise (signal
to noise with respect to 21.5 dB). Any value of 6 dB or greater is
adequate for reliable system operation.
PWR FEED OFF Power Feed Off HDSL2 span power has been turned off by setting the PWFD option to
off, or HDSL2 span power has been turned off by use of the A2LB
Intelligent Office Repeater (IOR) Power Down code.
PWR FEED ON Power Feed On Indicates that the HDSL2 loop is not grounded or shorted.
SIG Signaling The transceivers of the H2TU-C and H2TU-R are trying to establish
contact with each other over the HDSL2 loop of Span 1.
SYSTEM INFORMATION MESSAGES(a)
VER x.xx Software Version Number The software version number of the H2TU-C.
LIST xx List Number The list number of the H2TU-C.
FRM xxxx Frame: SF, ESF, UNFR, or AUTO Defines the type of frame pattern being received from the DSX-1:
SuperFrame (SF), Extended SuperFrame (ESF), Unframed (UNFR), or
AUTO.
CODE xxxx Line Code: AMI or B8ZS The DS1 line code setting: Alternate Mark Inversion (AMI) or Bipolar with
8-Zero Substitution (B8ZS).
LATT xx Loop Attenuation The current loop attenuation threshold setting measured in decibels.
MARG xx Margin The current margin threshold setting measured in decibels.
(a) System information messages are displayed in Scroll Mode. To scroll through the messages, press the MODE pushbutton for
3 or more seconds. After system information messages scroll, the front panel displays the line card options (see Table 5 on
page 16 and Table 6 on page 17).
Table 2. Front-Panel Display Messages (Continued)
Message Full Name Description