ADC PG-PLUS User manual

Section SCP-PCS719-030-03H
PG-Plus/PG-FlexPlus/Edge
PCS-719 23” Central Office Terminal/
Remote Terminal Shelf
Installation and Turn-up/Technical Practice
Model List CLEI Code
PCS-719 1A S9MTCB0A~~
3 S9MTEB0B~~
ASU-945 1 VAC2H90L~~


March 1, 2004 SCP-PCS719-030-03H
ADC Telecommunications, Inc. i
REVISION HISTORY
Copyright © 2004 ADC Telecomunications, Inc. All Rights Reserved.
ADC, PG-Plus, PG-Flex and PG-FlexPlus are all registered trademarks of ADC Telecommunications, Inc. No right,
license, or interest to such trademarks is granted hereunder, and you agree that you shall assert no such right,
license, or interest with respect to such trademarks.
Other product names mentioned in this document are used for identification purposes only and may be trademarks
or registered trademarks of their respective companies.
Information contained in this document is company private to ADC Telecommunications, Inc., and shall not be
modified, used, copied, reproduced or disclosed in whole or in part without the written consent of ADC.
Contents herein are current as of the date of publication. ADC reserves the right to change specifications at any time
without notice. Information furnished by ADC is believed to be accurate and reliable. In no event shall ADC be liable
for any damages resulting from the loss of data, loss of use, or loss of profits and ADC further disclaims any and all
liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to
all products, publications and services during and after the warranty period.
Revision Release Date Revisions Made
01 June 23, 2003 Initial Release
02 August 6, 2003 Updated external alarms
03 March 1, 2004 Updated DB-25 alarm information

SCP-PCS719-030-03H March 1, 2004
ii ADC Telecommunications, Inc.
USING THIS TECHNICAL PRACTICE
The following style conventions and terminology are used throughout this guide.
INSPECTING YOUR SHIPMENT
Upon receipt of the equipment:
• Unpack each container and visually inspect the contents for signs of damage. If the equipment has been dam-
aged in transit, immediately report the extent of damage to the transportation company and to ADC. Order
replacement equipment, if necessary.
• Check the packing list to ensure complete and accurate shipment of each listed item. If the shipment is short or
irregular, contact ADC as described in Product Support on page 49. If you must store the equipment for a pro-
longed period, store the equipment in its original container.
Reader Alert Meaning
Alerts you to supplementary information
!
IMPORTANT Alerts you to supplementary information that is essential to the completion of a task
ATTENTION
Alerts you to possible equipment damage from electrostatic discharge
CAUTION Alerts you to possible data loss, service-affecting procedures, or other similar type problems
WARNING Alerts you that failure to take or avoid a specific action might result in hardware damage or
loss of service
DANGER Alerts you that failure to take or avoid a specific action might result in personal harm

Table of Contents
March 1, 2004 SCP-PCS719-030-03H
ADC Telecommunications, Inc. iii
Revision History ...................................................................................................................... i
Using this Technical Practice ..................................................................................................ii
Inspecting Your Shipment .......................................................................................................ii
Overview ................................................................................................................................. 1
PCS-719 Supported System Configurations ..................................................................... 1
96-Channel Universal DAML COT .............................................................................. 2
192-Channel Integrated PG-FlexPlus COT ................................................................. 3
96-Channel Universal DLC COT to Plus RT ............................................................... 4
192-Channel Distributed DLC RT ................................................................................ 5
Edge RAM ................................................................................................................... 6
Edge IAD ...................................................................................................................... 8
Description and Features ........................................................................................................ 10
Features ............................................................................................................................ 10
Backplane Connections .................................................................................................... 11
Connector by type and function ........................................................................................ 12
Power ........................................................................................................................... 12
DS1 .............................................................................................................................. 12
DS3 .............................................................................................................................. 12
HDSL ...........................................................................................................................12
Two-Wire Subscriber Circuits ...................................................................................... 12
Alarm Cutoff ...................................................................................................................... 13
External Alarm Relay Contacts ......................................................................................... 13
External Environmental Alarm Contact Alarm Inputs/Outputs .......................................... 14
Supported NID/RT Service Types ..................................................................................... 15
Fusing and Heat Dissipation ............................................................................................. 16
Fusing 192-Channel Integrated COT or 192-Channel Distributed DLC RT Systems . 16
Fusing Universal DAML Systems ................................................................................ 17
Fusing CPOTS Systems .............................................................................................. 18
Fusing RPOTS Systems .............................................................................................. 18
Fusing Edge RAM and Edge IAD Systems ................................................................. 19
Network Interface ..............................................................................................................20
LAN Interface .................................................................................................................... 21
DSX-1 Connections ........................................................................................................... 21
DS3 Connections (for AMX-944 only) ............................................................................... 22
Specifications .......................................................................................................................... 22

SCP-PCS719-030-03H March 1, 2004
iv ADC Telecommunications, Inc.
Upgrading The PCS-719 L1A to L3 ........................................................................................ 23
Required Tool .................................................................................................................... 23
Installing the ASU-945 DS3 Splitter............................................................... Checkoff 23
INSTALLATION AND TEST .................................................................................................... 24
Required Tools and Test Equipment ................................................................................. 24
Required For All Shelf Installations ................................................................................... 24
Mounting ........................................................................................................ Checkoff 24
NEBS Compliance ......................................................................................... Checkoff 24
Ground Connections ......................................................................................................... 25
J22 Connection.............................................................................................. Checkoff 25
TB1 FGND Connection.................................................................................. Checkoff 25
Power Connections........................................................................................ Checkoff 25
Single Source Powering ......................................................................................... 26
Redundant Shelf Powering .................................................................................... 27
Split Shelf Powering ............................................................................................... 28
Alarm Output Connections............................................................................. Checkoff 29
Test Connections ........................................................................................... Checkoff 30
External ACO Connection.............................................................................. Checkoff 30
External Environmental Alarm Input Cable ............................................................ 30
Application-Specific Shelf Installations .............................................................................. 31
96-Channel Universal DAM ........................................................................... Checkoff 31
192-Channel Integrated COT ........................................................................ Checkoff 31
96-Channel Universal DLC COT/RT ............................................................. Checkoff 31
192-Channel Distributed DLC RT.................................................................. Checkoff 31
Edge RAM ..................................................................................................... Checkoff 31
Edge IAD........................................................................................................ Checkoff 31
DS0 Connections ......................................................................................................... 32
DSX-1 Connections ..................................................................................................... 32
DS3 Connections (For PCS-719 List 3 Only) .............................................................. 34
HDSL Wiring ................................................................................................................ 34

March 1, 2004 SCP-PCS719-030-03H
ADC Telecommunications, Inc. v
Turn-up and Test ..................................................................................................................... 39
Appendix A .............................................................................................................................. 41
Acronyms ................................................................................................................................ 47
Product Support ...................................................................................................................... 49
Technical Support ..............................................................................................................49
Limited Warranty ...............................................................................................................49
Returns .............................................................................................................................. 49
FCC Class A Compliance ....................................................................................................... 50
Modifications ..................................................................................................................... 50

List of Figures
March 1, 2004 SCP-PCS719-030-03H
ADC Telecommunications, Inc. vii
Figure 1. PCS-719 Shelf with ASU-945 DS3 Splitter ........................................................... 1
Figure 2. 96-Channel Universal DAML COT ........................................................................ 2
Figure 3. 192-Channel Integrated COT ................................................................................ 3
Figure 4. 96-Channel Universal DLC COT ........................................................................... 4
Figure 5. 192-Channel Distributed DLC RT .......................................................................... 5
Figure 6. Edge RAM System Configuration – AMX-943 ...................................................... 7
Figure 7. Edge RAM System Configuration – AMX-944 ...................................................... 7
Figure 8. Edge IAD System Configuration – AMX-943 ........................................................ 9
Figure 9. Edge IAD System Configuration – AMX-944 ........................................................ 9
Figure 10. PCS-719 Card Placement ..................................................................................... 10
Figure 11. PCS-719 Shelf Backplane ..................................................................................... 11
Figure 12. Alarm Relay Contacts and Alarm Block Diagram .................................................. 13
Figure 13. ENV Alarm Input Pinouts ....................................................................................... 14
Figure 14. Modem Connection for PCS-719 Backplane ........................................................ 20
Figure 15. Null Modem Connection for PCS-719 Backplane ................................................. 21
Figure 16. LAN Connector ...................................................................................................... 21
Figure 17. Remove Screws and Lock Washers ..................................................................... 23
Figure 18. Replace the Screws and Lock Washers ................................................................ 23
Figure 19. Single Source Power Wiring .................................................................................. 26
Figure 20. Redundant Shelf Power Wiring ............................................................................. 27
Figure 21. Split-Shelf Wiring ...................................................................................................28
Figure 22. Connecting the Alarm Relays ................................................................................ 29
Figure 23. Connecting the Test Pair and External ACO Switch ............................................. 30
Figure 24. DSX-1 Backplane Terminations ............................................................................. 33
Figure 25. DS3 Terminations .................................................................................................. 34
Figure 26. Connecting the HDSL Pairs .................................................................................. 35

List of Tables
March 1, 2004 SCP-PCS719-030-03H
ADC Telecommunications, Inc. ix
Table 1. PCS-719 Supported System Configurations .......................................................... 1
Table 2. Backplane Connectors ........................................................................................... 11
Table 3. Environmental Alarm Input Definitions ................................................................... 15
Table 4. DB-25 Alarm Cable Pinouts ................................................................................... 15
Table 5. Supported NID/RT Service Types .......................................................................... 15
Table 6. PCS-719 Shelf Power and Heat Dissipation for Integrated Systems .................... 16
Table 7. PCS-719 Shelf Power and Heat Dissipation for Universal Systems ...................... 17
Table 8. PCS-719 Shelf Power and Heat Dissipation for CPOTS ....................................... 18
Table 9. PCS-719 Shelf Power and Heat Dissipation for RPOTS ....................................... 18
Table 10. PCS-719 Shelf Power and Heat Dissipation for Edge RAM and Edge IAD ........... 19
Table 11. PCS-719 Backplane DB-25 Connector Pinouts ..................................................... 20
Table 12. Specifications ......................................................................................................... 22
Table 13. Alarm Terminations ................................................................................................. 29
Table 14. P1 Telco Connector Pinouts ................................................................................... 36
Table 15. P2 Telco Connector Pinouts ................................................................................... 36
Table 16. P3 Telco Connector Pinouts ................................................................................... 37
Table 17. P4 Telco Connector Pinouts ................................................................................... 37
Table 18. PCS-719 HDSL Connections ................................................................................. 38
Table 19. P1 Tip and Ring Pin Assignments .......................................................................... 42
Table 20. P2 Tip and Ring Pin Assignments .......................................................................... 43
Table 21. P3 Tip and Ring Pin Assignments .......................................................................... 44
Table 22. P4 Tip and Ring Pin Assignments .......................................................................... 45

March 1, 2004 SCP-PCS719-030-03H
ADC Telecommunications, Inc. 1
OVERVIEW
The PCS-719 is a versatile chassis that supports numerous application-specific configurations. The shelf can
accommodate a common management or alarm unit, two multiplexer units and up to 16 universal or integrated line
units or up to eight PG-FlexPlusTM integrated line units. The shelf and all associated plugs are hardened and suitable
for deployment in a remote cabinet, CEV, or other suitable location. Depending on the application, the PCS-719 can
be configured as a Central Office Terminal (COT) or a Remote Terminal (RT) Shelf.
Figure 1. PCS-719 Shelf with ASU-945 DS3 Splitter
PCS-719 SUPPORTED SYSTEM CONFIGURATIONS
Refer to Table 1 for PCS-719 supported system configurations.
Table 1. PCS-719 Supported System Configurations
The PCS-719 List 3 supports all of the system configurations; whereas, the PCS-719 List 1A supports all except
when deployed with the AMX-944 DS3 Multiplexer Unit. The AMX-944 must be installed in a PCS-719 List 3 shelf to
support a DS3 ATM interface.
The List 1A and List 3 COT Shelves are identical except the List 3 shelf includes the ASU-945 DS3
splitter bracket for use with the AMX-944 (Figure 1).
System Configuration Narrowband Broadband ATM
96-Channel Universal Digital Added Main Line (DAML) COT 2, 4, 6
192-Channel Integrated PG-FlexPlus COT
96-Channel Universal DLC COT to PG-Plus RT
192-Channel Distributed DLC RT
Edge Remote Access Multiplexer (RAM)
Edge Integrated Access Device (IAD)
ADC Recommendation: For maximum system flexibility, ADC recommends use of the PCS-719
List 3 for all system configurations.
ASU-945 DS3 Splitter (L3 Only) Bracket

SCP-PCS719-030-03H March 1, 2004
2ADC Telecommunications, Inc.
96-Channel Universal DAML COT
The 96-Channel Universal DAML configuration includes:
• Shelf typically deployed in a CO environment
• Analog tip/ring input from switch
• Supports up to 96 DS0s
• Each slot supports up to 6 DS0s per a single pair High-bit-rate Digital Subscriber Line (HDSL) except Dual 2
POTS supports 2 each single pair HDSL
• Configuration supports POTS
• Configuration supports Enhanced Business Service (EBS) (P-Phone)
• Configuration supports Integrated Services Digital Network (ISDN)
• Shelf provides line powering for various Network Interface Devices (NIDs)
• Local powering not required at NID
Refer to Figure 2 for the 96-Channel Universal DAML system configuration.
Figure 2. 96-Channel Universal DAML COT
PLL-734
PG-Plus
COT Shelf
PLL-722
3 POTS
&
1 ISDN
PRL-772
NID
PRL-770
NID
2 POTS
PLL-721
6 POTS
PRL-771
NID
2 POTS
PRL-770
NID
HDSL
HDSL
HDSL
HDSL
AMU-912
M
D
F
96 Analog Tip/Rings
Class 5
Switch
VT-1
00
T
e
rmin
a
l

March 1, 2004 SCP-PCS719-030-03H
ADC Telecommunications, Inc. 3
192-Channel Integrated PG-FlexPlus COT
The 192-Channel Integrated configuration includes:
• Shelf typically deployed in a CO environment
• Can be deployed remotely, if desired
• DS1 input from switch
• Supports up to 192 DS0s
• Each slot supports up to 12 DS0s via dual single pair HDSL
• Configuration supports POTS services
• Supports Loop Start/Ground Start (LS/GS) services
• Shelf provides line powering for various NIDs and RTs
• Local powering not required at RT
• Local powering option with 24-channel PG-FlexPlus Remotes
Refer to Figure 3 for the 192-Channel Integrated COT system configuration.
Figure 3. 192-Channel Integrated COT
PLL-735
PG-Plus
COT Shelf
PLL-735
HDSL
(1 pair per NID)
HDSL
(1 pair per NID)
6 POT
S
PG-Flex
Doubler
PRL-771
NID
PRL-779
NID
6 POTS
PMX-744
HDSL
(2 pair per RT)
AMU-912
FLL-814
HDSL
(2 pair per RT)
Power
(2 pair per Doubler)
Class 5
Switch
24 POTS
24 Ch.
Enclosure
DSX1
(8)
DSX1
(8)
PMX-744
PMX-744
Transport
Medium
VT-100 Terminal

SCP-PCS719-030-03H March 1, 2004
4ADC Telecommunications, Inc.
96-Channel Universal DLC COT to Plus RT
The 96-Channel Universal DLC configuration includes:
• Shelves deployed at the CO and remote location
• Analog tip/ring input from switch
• DS1 input to Remote Shelf
• Supports up to 96 DS0s
• Each slot supports up to 6 DS0s
• Supports POTS services
• Supports up to 4 DS1s with a 5th for protection
Refer to Figure 4 for the 96-Channel Universal DLC COT system configuration.
Figure 4. 96-Channel Universal DLC COT
4 DS1s Plus Optional
Protection to RT
FPC-806
PG-Plus
COT Shelf
AMU-912
PMX-744
PMX-744
FPC-806
FPC-806
FPC-806
FPR-806
PG-Plus
RT Shelf
FPR-806
FPR-806
FPR-806
AMU-912
PMX-744
PMX-744
96 Analog Drops
VT-100 Terminal
M
D
F
96 Analog Tip/Rings
Class 5
Switch
VT-1
00
T
e
rmin
a
l

March 1, 2004 SCP-PCS719-030-03H
ADC Telecommunications, Inc. 5
192-Channel Distributed DLC RT
The 192-Channel Distributed DLC configuration includes:
• Shelf typically deployed in the field (CEV or outdoor Cabinet)
• DS1 input from switch
• Supports up to 192 DS0s
• Each slot supports up to 12 DS0s
• Supports TR-08 Mode 1, SF, or ESF Integrated Channel Bank (ICB) interfaces
• DS0s dropped off via FPR-806 or distributed to line-powered, micro-DLC remotes
Refer to Figure 5 for the 192-Channel Distributed DLC RT system configuration.
Figure 5. 192-Channel Distributed DLC RT
PMX-744
PG-Plus
COT Shelf
PLL-735
PLL-735
HDSL
(1 pair per NID)
PG-Flex
Doubler
PRL-771
NID
6 POTS
PMX-744
HDSL
(2 pair per RT)
AMU-912
FLL-814
HDSL
(2 pair per RT)
Power
(2 pair per Doubler)
Class 5
Switch
24 POTS
24 Ch.
Enclosure
DSX1
(8)
DSX1
(8)
PLL-735
FPR-806
Transport
Medium
VT-1
00
Te r m i n a l

SCP-PCS719-030-03H March 1, 2004
6ADC Telecommunications, Inc.
Edge RAM
The Edge RAM configuration includes:
• Redundant multiplexers provide DS1 circuit protection
• ASU-945 splitter provides DS3 circuit protection
• Shelf supports up to 16 ALU-935s
• DS1 (AMX-943) or DS3 (AMX-944) ATM interface options
• AMX-944 supports 8 TDM DS1s for up to 192 DS0s
• AMX-944 supports ATM DS3 interface for up to 256 PVCs
• AMX-944 supports up to 11 Crossbox RTs (24 ADSLs each)
• AMX-943 supports 4 TDM DS1s for up to 96 DS0s
• AMX-943 supports 4 ATM DS1s for up to 128 PVCs
• AMX-943 supports up to 6 Crossbox RTs (24 ADSLs each)
• Uses Symmetric High-bit-rate Digital Subscriber Line (SHDSL) circuits between RAM and COT Shelf
• Extends Asynchronous Digital Subscriber Line (ADSL) services beyond the normal ADSL range
• Provides ADSL drops to the subscriber
• Crossbox RT combines POTS and ADSL over a single copper pair
• Crossbox RT supports up tp 3 SHDSL circuits
• Each SHDSL supports up to 8 ADSL circuits
• Crossbox RT supports 3 ARL-942s and 3 ASU-940s (24 ADSL subscribers)
• Analog POTS circuits terminating in Crossbox RT are provided over copper pairs from switch/DLC and com-
bined in ASU-940 with the ADSL circuits originating from the ARL-942
Refer to Figure 6 on page 7 and Figure 7 on page 7 for the Edge RAM system configuration.

March 1, 2004 SCP-PCS719-030-03H
ADC Telecommunications, Inc. 7
Figure 6. Edge RAM System Configuration – AMX-943
Figure 7. Edge RAM System Configuration – AMX-944
ATM Switch
or
DSLAM
Class 5
Switch
ARL-942 ASU-940
ASU-940
ASU-940
ARL-942
ARL-942
ARX-965
Crossbox RT
8 ADSL/POTS drops per
ARL-942/ASU-940
(24 drops per ARX-965)
DSX-1 - ATM
(4 circuits - 8 pairs)
POTS (8 pairs per ASU-940)
AMU-912
AMX-943
AMX-943
ALU-935
ALU-935
ALU-935
ALU-935
ALU-935
PG-Plus
COT Shelf
2 SHDSL pairs
per ALU-935
VT-100 Terminal
SHDSL
(1 pair per ARL-942)
ATM Switch
or
DSLAM
Class 5
Switch
ASU-945 ARL-942 ASU-940
ASU-940
ASU-940
ARL-942
ARL-942
ARX-965
Crossbox RT
8 ADSL/POTS drops per
ARL-942/ASU-940
(24 drops per ARX-965)
DS3
(1 circuit - 2 coax cables)
POTS (8 pairs per ASU-940)
AMU-912
AMX-944
AMX-944
ALU-935
ALU-935
ALU-935
ALU-935
PG-Plus
COT Shelf
2 SHDSL pairs
per ALU-935
VT-100 Terminal
SHDSL
(1 pair per ARL-942)
ALU-935

SCP-PCS719-030-03H March 1, 2004
8ADC Telecommunications, Inc.
Edge IAD
The Edge IAD configuration includes:
• Redundant multiplexers provide DS1 circuit protection
• ASU-945 splitter provides DS3 circuit protection
• Shelf supports up to 16 ALU-935s
• AMX-944 supports 8 TDM DS1s for up to 192 DS0s
• AMX-944 supports ATM DS3 interface for up to 256 PVCs
• AMX-943 supports 4 TDM DS1s for up to 96 DS0s
• AMX-943 supports 4 ATM DS1s for up to 128 PVCs
• IAD provides ADSL services to multi-line subscribers over a single copper pair
• SHDSL circuits transport ADSL and POTS between COT Shelf and NID
• NID provides 1 ADSL and 3 or 6 Universal Voice Grade (UVG) POTS circuits to the subscriber
• Each ALU-935 supports 2 ARB-96x NIDs
• 3 and 6 POTS NIDs can be mixed on the same ALU-935
• ARB-963 NIDs can be ordered with or without built-in splitters
Refer to Figure 8 on page 9 and Figure 9 on page 9 for the Edge IAD system configuration.