∗49 Split/Dual Reporting [0]
0 = Standard/Backup reporting only (all to primary unless fail)
Primary Phone No. 2nd Phone No.
1 = Alarms, Restore, Cancel Others
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All
4 = All except Open/Close, Test All
5 = All All
∗50 Burglary Dialer Delay [2]
0 = no delay UL: must be “0”
1 = 15 seconds SIA Installations: delay
2 = 30 seconds must be minimum of
3 = 45 seconds 30 seconds
∗53 SESCOA/Radionics Select [0]
0 = Radionics (0-9, B-F), and all formats other than SESCOA
1 = SESCOA (0-9 only reporting)
∗54 Dynamic Signaling Delay [0]
Delay selectable from 0 to 225 secs in 15-sec increments.
0 = no delay (both signals sent),
1 = 15 secs,
2 = 30 secs, etc
UL: Grade AA must be “0;”Grade A must be “15”max
∗55 Dynamic Signaling Priority [0]
0 = Primary Dialer first; 1 = Long Range Radio first.
For UL Commercial Burglary installations that use a DACT
and LRR, this field must be “0”.
∗56 -*58 Menu Modes (see page 2 for description)
PROGRAMMING SYSTEM STATUS, & RESTORE REPORT
CODES (✱59 –✱76, & ✱89):
For 3+1 or 4+1 Standard Format: Enter a code in the
first
box: 1–
9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15
for F.
A 0 (
not
#+10) in the
first
box will disable a report. A 0 (
not
#+10) in
the
second
box will result in automatic advance to the next field.
For Expanded or 4+2 Format: Enter codes in
both
boxes (1st and
2nd digits) for 1–9, 0, or B–F, as described above.
A 0 (
not
#+10) in the
second
box will eliminate the expanded
message for that report. A 0 (
not
#+10) in
both
boxes will disable
the report.
For Ademco Contact ID®Reporting: Enter any digit (other than 0)
in the
first
box, to enable zone to report (entries in the
second
boxes
are ignored).
A 0 (
not
#+10) in the
first
box disables the report.
UL: see installation instructions for requirements
SYSTEM STATUS REPORT CODES
∗59 Exit Error Report Code [0]
∗60 Trouble Report Code [00] |
∗61 Bypass Report Code [00] |
∗62 AC Loss Report Code [00] |
∗63 Low Bat Report Code [00] |
∗64 Test Report Code [00] |
Use Scheduling mode to set periodic test reports or use the
following key commands to set schedule 2 to the stated
repeat option (first test report sent 12 hours after command):
installer code +[#] + [0] + 0 = test report sent every 24 hours
installer code +[#] + [0] + 1 = test report sent once per week
installer code +[#] + [0] + 2 = test report sent every 28 days
∗65 Open Report Code [0]
∗66 Arm Away/Stay Rpt Code [0,0]
Away Stay
∗67 RF Trans. Low Bat Report Code [00] |
UL: must be enabled if wireless devices are used
∗68 Cancel Report Code [00] |
RESTORE REPORT CODES
∗70 Alarm Restore Rpt Code [0]
∗71 Trouble Restore Rpt Code [00] |
∗72 Bypass Restore Rpt Code [00] |
∗73 AC Restore Rpt Code [00] |
∗74 Low Bat Restore Rpt Code [00] |
∗75 RF Trans. Lo Bat Rst Rpt Code [00] |
UL: must be enabled if wireless devices are used
∗76 Test Restore Rpt Code [00] |
OUTPUT AND SYSTEM SETUP
∗77 Daylight Savings Time
Start\End Month [4][10] |
0 = Disabled
1-9 = January-September (1 = Jan, 2 = Feb, etc)
#+10 = October; #+11 = November; #+12 = December
∗78 Daylight Savings Time
Start\End Weekend [1][5] |
0 = disabled, 1 = first, 2 = second, 3 = third
4 = fourth, 5 = last, 6 = next to last, 7 = third to last
∗79 -*82 Menu Modes (see page 2 for description)
∗84 Auto Stay Arm [1]
0 = no, 1 = yes, auto stay arm enabled
∗85 Cross Zone Timer
This option not for use in UL installations. [0]
0 = 15 seconds 6 = 2-1/2 min #+12 = 8 min
1 = 30 seconds 7 = 3 min #+13 = 10 min
2 = 45 seconds 8 = 4 min #+14 = 12 min
3 = 60 seconds 9 = 5 min #+15 = 15 min
4 = 90 seconds #+10 = 6 min
5 = 2 minutes #+11 = 7 min
(assign cross zones on zone list 4, with *81 Menu mode)
∗86 Cancel Verify Keypad Display [1]
0 = no, 1 = yes
∗87 Misc. Fault Delay Time [0]
(used with Configurable Zone Type “digit 6”)
0 = 15 seconds 6 = 2-1/2 min #+12 = 8 min
1 = 30 seconds 7 = 3 min #+13 = 10 min
2 = 45 seconds 8 = 4 min #+14 = 12 min
3 = 60 seconds 9 = 5 min #+15 = 15 min
4 = 90 seconds #+10 = 6 min
5 = 2 minutes #+11 = 7 min
UL: may only be used on non-burglar alarm/ non-fire alarm zones
when used in fire and/or UL burglar alarm installation
∗88 Program Mode Lockout Options [0]
0 = standard *98 installer code lockout
(reentry only by [∗] + [#] within 50 seconds after power up)
1 = lockout [∗] + [#] reentry after *98 exit
2 = not used
3 = lockout all local programming after *98 exit (reentry via
downloader only)