manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Network Hardware
  8. •
  9. ADTRAN 1442300G1 User manual

ADTRAN 1442300G1 User manual

Other ADTRAN Network Hardware manuals

ADTRAN HD-10 BRI MUX Instruction Manual

ADTRAN

ADTRAN HD-10 BRI MUX Instruction Manual

ADTRAN 622v XGS-PON ONT User manual

ADTRAN

ADTRAN 622v XGS-PON ONT User manual

ADTRAN T400 Instruction Manual

ADTRAN

ADTRAN T400 Instruction Manual

ADTRAN NetVanta 1700801G1 User manual

ADTRAN

ADTRAN NetVanta 1700801G1 User manual

ADTRAN jobAid 1442351G1 User manual

ADTRAN

ADTRAN jobAid 1442351G1 User manual

ADTRAN Total Access 604 User guide

ADTRAN

ADTRAN Total Access 604 User guide

ADTRAN SFP Series User manual

ADTRAN

ADTRAN SFP Series User manual

ADTRAN DSU IV ESP User manual

ADTRAN

ADTRAN DSU IV ESP User manual

ADTRAN NxT1 HSSI/V-35 User manual

ADTRAN

ADTRAN NxT1 HSSI/V-35 User manual

ADTRAN 1490 TX User manual

ADTRAN

ADTRAN 1490 TX User manual

ADTRAN DSX 1 User manual

ADTRAN

ADTRAN DSX 1 User manual

ADTRAN FNID Manual

ADTRAN

ADTRAN FNID Manual

ADTRAN 1200130L1 User manual

ADTRAN

ADTRAN 1200130L1 User manual

ADTRAN 1203019L2 User manual

ADTRAN

ADTRAN 1203019L2 User manual

ADTRAN Total Access 362R User manual

ADTRAN

ADTRAN Total Access 362R User manual

ADTRAN Ethernet Over Bonded Copper MX3112 User manual

ADTRAN

ADTRAN Ethernet Over Bonded Copper MX3112 User manual

ADTRAN 1442823F1 User manual

ADTRAN

ADTRAN 1442823F1 User manual

ADTRAN Total Access SHDSL LTU Instruction Manual

ADTRAN

ADTRAN Total Access SHDSL LTU Instruction Manual

ADTRAN 1200184L1 User manual

ADTRAN

ADTRAN 1200184L1 User manual

ADTRAN Total Access 300 Series Product manual

ADTRAN

ADTRAN Total Access 300 Series Product manual

ADTRAN ACT 1900 User manual

ADTRAN

ADTRAN ACT 1900 User manual

ADTRAN DSX 1 User manual

ADTRAN

ADTRAN DSX 1 User manual

ADTRAN SHDSL V.35 LTU User manual

ADTRAN

ADTRAN SHDSL V.35 LTU User manual

ADTRAN DSU 56/64 User manual

ADTRAN

ADTRAN DSU 56/64 User manual

Popular Network Hardware manuals by other brands

socomec SNMP Card II quick start guide

socomec

socomec SNMP Card II quick start guide

NVR SYSTEMS 4-CH user manual

NVR SYSTEMS

NVR SYSTEMS 4-CH user manual

Draytek VigorSwitch G1240 quick start guide

Draytek

Draytek VigorSwitch G1240 quick start guide

Westermo TD-34 LV installation manual

Westermo

Westermo TD-34 LV installation manual

LaCie Network Space MAX Quick install guide

LaCie

LaCie Network Space MAX Quick install guide

ZoneVu ZSI-450-IP Installation guide & user manual

ZoneVu

ZoneVu ZSI-450-IP Installation guide & user manual

QNAP Turbo NAS Application notes

QNAP

QNAP Turbo NAS Application notes

OpenEye MV Series quick start guide

OpenEye

OpenEye MV Series quick start guide

Huawei SmartAX MT880a quick start guide

Huawei

Huawei SmartAX MT880a quick start guide

Proxim Tsunami QuickBridge 2454-R installation guide

Proxim

Proxim Tsunami QuickBridge 2454-R installation guide

Bay Networks CLAM quick start guide

Bay Networks

Bay Networks CLAM quick start guide

Innodisk SATADOM-SH 3SE Series manual

Innodisk

Innodisk SATADOM-SH 3SE Series manual

Cisco CGR 1000 Series Getting connected guide

Cisco

Cisco CGR 1000 Series Getting connected guide

Matrix Switch Corporation MSC-HD161DEL product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-HD161DEL product manual

National Instruments NI 653x user manual

National Instruments

National Instruments NI 653x user manual

B&B Electronics ZXT9-IO-222R2 product manual

B&B Electronics

B&B Electronics ZXT9-IO-222R2 product manual

Yudor YDS-16 user manual

Yudor

Yudor YDS-16 user manual

D-Link ShareCenter DNS-320L datasheet

D-Link

D-Link ShareCenter DNS-320L datasheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

jobAid
DESCRIPTION
TheSmallForm‐FactorPluggable(SFP)isacopperSFPthatplugs
intoanADTRANGigECopperinterfacedesignedtoacceptSFPs.
TheSFPprovidesasingleelectricalinterfacetoaphysical
interface.
Installedintoanappropriatemodule,thisSFPprovidesa10/100/
1000Mbpsfullduplexdata‐link.
ThefollowingfeaturesaresupportedontheSFP:
♦Upto1.25Gbpsbidirectionaldatalinks
♦Hot‐pluggablefootprint
♦100metermaximumdistanceovershieldedtwisted‐pairCat5
cable
♦Supports10/100/1000Mbpsusingtheappropriatemodule/
platform
Operational Specifications
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–40°Cto+85°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto95%,noncondensing
◊OperatingAltitudeRange:–197(–60meters)to13000feet
(3962meters)
NOTE
Theoperatingambienttemperatureisderatedby1°C/1000feet
(3.3°C/km).
CAUTION
!
Duetocompliancecertificationrequirements,onlySFPs
approvedbyADTRANaretobeusedwiththehostmodule.
ADTRANcannotcertifysystemintegritywithotherSFPs.
INSTALLATION
ToinstalltheSFPintoanappropriatemodule,completethe
followingsteps:
InspecttheSFP.Ifdamaged,fileaclaimwiththecarrierandthen
contactADTRANCustomerSupport.
CAUTION
!
Ifpresent,donotremovetheprotectiveendcapfromtheSFP
untiltheCat5cableisreadytobeconnected.
1. InserttheSFPintotheSFPcageonthemodule.Ensurethe
latchontheSFPisfacingupwardforcorrectinstallation.
2. SlidetheSFPallthewayintotheSFPcageuntilthereisan
audible“click”.
NOTE
♦ ThelatchontheSFPisusedtoremovetheSFPfromthecage
onthecircuitcard.
♦ TheSFPmeetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR‐63‐CORE,andGR‐1089‐CORE.
COMPLIANCE
WARNING
!
TheSFPportisclassifiedasType2orType4,asdefinedin
AppendixBofGR‐1089‐COREIssue5,andissuitablefor
connectiontointra‐buildingorunexposedwiringorcablingonly.
Donotmetallicallyconnectthisporttointerfaceswhichconnect
toOutsidePlant(OSP)ortotheOSPwiring.TheSFPportis
designedforuseasanintrabuildinginterfaceonly(Type2orType
4),andrequiresisolationfromexposedOSPcabling.
TheadditionofPrimaryProtectorsisnotsufficientprotectionin
ordertoconnectthisinterfacemetallicallytoOSPwiring.TheSFP
portissuitableforconnectiononlytoshieldedintra‐building
cablinggroundedatbothends.
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargestrapto
preventdamagetoelectroniccomponents.Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
workingonmodules,alwaysplacethemonanapproved
antistaticmatthatiselectricallygrounded.
NOTE
TheSFPhasbeenevaluatedtointernationalsafetystandardsEN
60950‐1,AS/NZS60950.1,andIEC60950‐1.TheSFPmeetsthe
requirementsforCEmarkingundertheEMCDirectiveandLow
VoltageDirective.StandardsusedtodemonstrateComplianceare
EN300386,EN50222,EN55024asapplicableandEN60950.
CAUTION
!
TheSFPisintendedfordeploymentinCentralofficetype
facilities,EEEs,EECs,andlocationswhereNECapplies(for
example,CustomerPremises).TheSFPmustbeinstalledby
trainedservicepersonnelinADTRANproductsthatarelocated
inRestrictedAccessLocations.
CLEI: SOOTAK9J_ _
Product P/N: 1442300G1
Issue Date: April 2010
Document P/N: 61442300G1-22B
Small Form-Factor Pluggable
1.25 GigE Copper SFP
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
Warranty:ADTRAN will replace or repair this product within the warranty period if it does not meet its
published specifications or fails while in service. Warranty information can be found online at
www.adtran.com/warranty.
©2010 ADTRAN, Inc. All Rights Reserved.
*61442300G1-22B*
CAUTION
!
♦ PerGR‐1089‐COREtheADTRANsystemthattheSFPisbeing
deployedinisdesignedandintendedforinstallationaspartof
aCommonBondingNetwork(CBN).TheADTRANsystem
thattheSFPisbeingdeployedinisnotdesignednorintended
forinstallationaspartofanIsolatedBondingNetwork(IBN).
♦ PerGR‐1089‐CORESection9,theSFPdoesnothaveaninternal
DCconnectionbetweenbatteryreturnandframeground.The
SFPcanbeinstalledinaDC‐I(isolated)orDC‐C(common)
configuration.Forinstallationswhereothercardsorthehost
systemhaveinternalconnectionsbetweenbatteryreturnand
frameground,thesystemwouldbeintendedfordeployment
onlyinaDC‐Cconfiguration.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheSFPisproperlygroundedviathebackplane
connector.
NOTE
TheSFPisdesignedfordeploymentinGR‐3108‐CORE
environmentalclass1and2,asdefinedinGR‐3108‐CORE,Issues
2.
TheSFPisdesignedtomeetthefollowingenvironmentalclasses:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
TheSmallForm‐FactorPluggablemeetsEURoHSDirective2002/
95/ECand/orapplicableexemptions.Refertowww.adtran.com
forfurtherinformationonRoHS/WEEE.