DESCRIPTION
TheSmallForm‐FactorPluggable(SFP)isacopperSFPthatplugs
intoanADTRANGigECopperinterfacedesignedtoacceptSFPs.
TheSFPprovidesasingleelectricalinterfacetoaphysical
interface.
Installedintoanappropriatemodule,thisSFPprovidesa10/100/
1000Mbpsfullduplexdata‐link.
ThefollowingfeaturesaresupportedontheSFP:
♦Upto1.25Gbpsbidirectionaldatalinks
♦Hot‐pluggablefootprint
♦100metermaximumdistanceovershieldedtwisted‐pairCat5
cable
♦Supports10/100/1000Mbpsusingtheappropriatemodule/
platform
Operational Specifications
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–40°Cto+85°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto95%,noncondensing
◊OperatingAltitudeRange:–197(–60meters)to13000feet
(3962meters)
NOTE
Theoperatingambienttemperatureisderatedby1°C/1000feet
(3.3°C/km).
CAUTION
!
Duetocompliancecertificationrequirements,onlySFPs
approvedbyADTRANaretobeusedwiththehostmodule.
ADTRANcannotcertifysystemintegritywithotherSFPs.
INSTALLATION
ToinstalltheSFPintoanappropriatemodule,completethe
followingsteps:
InspecttheSFP.Ifdamaged,fileaclaimwiththecarrierandthen
contactADTRANCustomerSupport.
CAUTION
!
Ifpresent,donotremovetheprotectiveendcapfromtheSFP
untiltheCat5cableisreadytobeconnected.
1. InserttheSFPintotheSFPcageonthemodule.Ensurethe
latchontheSFPisfacingupwardforcorrectinstallation.
2. SlidetheSFPallthewayintotheSFPcageuntilthereisan
audible“click”.
NOTE
♦ ThelatchontheSFPisusedtoremovetheSFPfromthecage
onthecircuitcard.
♦ TheSFPmeetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR‐63‐CORE,andGR‐1089‐CORE.
COMPLIANCE
WARNING
!
TheSFPportisclassifiedasType2orType4,asdefinedin
AppendixBofGR‐1089‐COREIssue5,andissuitablefor
connectiontointra‐buildingorunexposedwiringorcablingonly.
Donotmetallicallyconnectthisporttointerfaceswhichconnect
toOutsidePlant(OSP)ortotheOSPwiring.TheSFPportis
designedforuseasanintrabuildinginterfaceonly(Type2orType
4),andrequiresisolationfromexposedOSPcabling.
TheadditionofPrimaryProtectorsisnotsufficientprotectionin
ordertoconnectthisinterfacemetallicallytoOSPwiring.TheSFP
portissuitableforconnectiononlytoshieldedintra‐building
cablinggroundedatbothends.
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargestrapto
preventdamagetoelectroniccomponents.Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
workingonmodules,alwaysplacethemonanapproved
antistaticmatthatiselectricallygrounded.
NOTE
TheSFPhasbeenevaluatedtointernationalsafetystandardsEN
60950‐1,AS/NZS60950.1,andIEC60950‐1.TheSFPmeetsthe
requirementsforCEmarkingundertheEMCDirectiveandLow
VoltageDirective.StandardsusedtodemonstrateComplianceare
EN300386,EN50222,EN55024asapplicableandEN60950.
CAUTION
!
TheSFPisintendedfordeploymentinCentralofficetype
facilities,EEEs,EECs,andlocationswhereNECapplies(for
example,CustomerPremises).TheSFPmustbeinstalledby
trainedservicepersonnelinADTRANproductsthatarelocated
inRestrictedAccessLocations.
CLEI: SOOTAK9J_ _
Product P/N: 1442300G1
Issue Date: April 2010
Document P/N: 61442300G1-22B
Small Form-Factor Pluggable
1.25 GigE Copper SFP
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
Warranty:ADTRAN will replace or repair this product within the warranty period if it does not meet its
published specifications or fails while in service. Warranty information can be found online at
www.adtran.com/warranty.
©2010 ADTRAN, Inc. All Rights Reserved.
*61442300G1-22B*
CAUTION
!
♦ PerGR‐1089‐COREtheADTRANsystemthattheSFPisbeing
deployedinisdesignedandintendedforinstallationaspartof
aCommonBondingNetwork(CBN).TheADTRANsystem
thattheSFPisbeingdeployedinisnotdesignednorintended
forinstallationaspartofanIsolatedBondingNetwork(IBN).
♦ PerGR‐1089‐CORESection9,theSFPdoesnothaveaninternal
DCconnectionbetweenbatteryreturnandframeground.The
SFPcanbeinstalledinaDC‐I(isolated)orDC‐C(common)
configuration.Forinstallationswhereothercardsorthehost
systemhaveinternalconnectionsbetweenbatteryreturnand
frameground,thesystemwouldbeintendedfordeployment
onlyinaDC‐Cconfiguration.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheSFPisproperlygroundedviathebackplane
connector.
NOTE
TheSFPisdesignedfordeploymentinGR‐3108‐CORE
environmentalclass1and2,asdefinedinGR‐3108‐CORE,Issues
2.
TheSFPisdesignedtomeetthefollowingenvironmentalclasses:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
TheSmallForm‐FactorPluggablemeetsEURoHSDirective2002/
95/ECand/orapplicableexemptions.Refertowww.adtran.com
forfurtherinformationonRoHS/WEEE.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807

Other ADTRAN Network Hardware manuals

ADTRAN TRACER 64 0 Series User manual

ADTRAN

ADTRAN TRACER 64 0 Series User manual

ADTRAN 1442351G7 User manual

ADTRAN

ADTRAN 1442351G7 User manual

ADTRAN OSU 300 User manual

ADTRAN

ADTRAN OSU 300 User manual

ADTRAN NetVanta 2300 User manual

ADTRAN

ADTRAN NetVanta 2300 User manual

ADTRAN HDSL 3192 HTU-C Instruction Manual

ADTRAN

ADTRAN HDSL 3192 HTU-C Instruction Manual

ADTRAN 1200221L1 User manual

ADTRAN

ADTRAN 1200221L1 User manual

ADTRAN jobAid NETVANTA User manual

ADTRAN

ADTRAN jobAid NETVANTA User manual

ADTRAN FNID Manual

ADTRAN

ADTRAN FNID Manual

ADTRAN HD-10 BRI MUX Instruction Manual

ADTRAN

ADTRAN HD-10 BRI MUX Instruction Manual

ADTRAN 1442880G1 User manual

ADTRAN

ADTRAN 1442880G1 User manual

ADTRAN TRACER 4x03 User manual

ADTRAN

ADTRAN TRACER 4x03 User manual

ADTRAN 1203019L2 User manual

ADTRAN

ADTRAN 1203019L2 User manual

ADTRAN Total Access 301 User manual

ADTRAN

ADTRAN Total Access 301 User manual

ADTRAN 1442704PG1 User manual

ADTRAN

ADTRAN 1442704PG1 User manual

ADTRAN NIU3 Instruction Manual

ADTRAN

ADTRAN NIU3 Instruction Manual

ADTRAN Total Access DSLAM Octal SHDSL User manual

ADTRAN

ADTRAN Total Access DSLAM Octal SHDSL User manual

ADTRAN Total Access 372E User manual

ADTRAN

ADTRAN Total Access 372E User manual

ADTRAN 1202801L1 User manual

ADTRAN

ADTRAN 1202801L1 User manual

ADTRAN T200 HTU-R Instruction Manual

ADTRAN

ADTRAN T200 HTU-R Instruction Manual

ADTRAN 622v XGS-PON ONT User manual

ADTRAN

ADTRAN 622v XGS-PON ONT User manual

ADTRAN BR1/10 PAU Instruction Manual

ADTRAN

ADTRAN BR1/10 PAU Instruction Manual

ADTRAN Total Access 374 Product manual

ADTRAN

ADTRAN Total Access 374 Product manual

ADTRAN 1200 Series User manual

ADTRAN

ADTRAN 1200 Series User manual

ADTRAN Total Access 362R Product manual

ADTRAN

ADTRAN Total Access 362R Product manual

Popular Network Hardware manuals by other brands

FieldServer Metasys N2 FS-8700-19 Driver manual

FieldServer

FieldServer Metasys N2 FS-8700-19 Driver manual

Opengear CM4116 quick start guide

Opengear

Opengear CM4116 quick start guide

Adaptec AAA-133U2 Hardware guide

Adaptec

Adaptec AAA-133U2 Hardware guide

Microsemi 9001G-40/SP user guide

Microsemi

Microsemi 9001G-40/SP user guide

NEC N8151-51A Guide usage notes

NEC

NEC N8151-51A Guide usage notes

Airspan AirSpeed 1050 B3 installation guide

Airspan

Airspan AirSpeed 1050 B3 installation guide

Cisco CPS-MSP-1RU-K9 user guide

Cisco

Cisco CPS-MSP-1RU-K9 user guide

Vpon VP-2 Series Quick reference manual

Vpon

Vpon VP-2 Series Quick reference manual

PaloAlto Networks ION 1000 Hardware reference

PaloAlto Networks

PaloAlto Networks ION 1000 Hardware reference

Sophos XGS 7500 quick start guide

Sophos

Sophos XGS 7500 quick start guide

ACTi GNR -3000 user manual

ACTi

ACTi GNR -3000 user manual

LaCie 5big - Network NAS Server Quick install guide

LaCie

LaCie 5big - Network NAS Server Quick install guide

Vivint Air Tower quick reference

Vivint

Vivint Air Tower quick reference

Risco LightSYS Plus user manual

Risco

Risco LightSYS Plus user manual

AMX AXB-PSCV Dimensional drawing

AMX

AMX AXB-PSCV Dimensional drawing

SMC Sierra Monitor ProtoNode FPC-N34 Startup guide

SMC Sierra Monitor

SMC Sierra Monitor ProtoNode FPC-N34 Startup guide

GRASS VALLEY K2 BASECAMP EXPRESS Service manual

GRASS VALLEY

GRASS VALLEY K2 BASECAMP EXPRESS Service manual

Enable-IT 360 quick start guide

Enable-IT

Enable-IT 360 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.