manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Network Hardware
  8. •
  9. ADTRAN U-BR1TE User manual

ADTRAN U-BR1TE User manual

Other manuals for U-BR1TE

6

Other ADTRAN Network Hardware manuals

ADTRAN DSU III AR User manual

ADTRAN

ADTRAN DSU III AR User manual

ADTRAN GPON 452 User manual

ADTRAN

ADTRAN GPON 452 User manual

ADTRAN Cable T1 ESF CSU ACE User manual

ADTRAN

ADTRAN Cable T1 ESF CSU ACE User manual

ADTRAN 1202803L1 User manual

ADTRAN

ADTRAN 1202803L1 User manual

ADTRAN 6540 Product manual

ADTRAN

ADTRAN 6540 Product manual

ADTRAN NetVanta Series User manual

ADTRAN

ADTRAN NetVanta Series User manual

ADTRAN XFP NG-PON2 ONU User manual

ADTRAN

ADTRAN XFP NG-PON2 ONU User manual

ADTRAN 1490 TX User manual

ADTRAN

ADTRAN 1490 TX User manual

ADTRAN TRACER 5045 User guide

ADTRAN

ADTRAN TRACER 5045 User guide

ADTRAN SDX 611 GPON SFU ONT User manual

ADTRAN

ADTRAN SDX 611 GPON SFU ONT User manual

ADTRAN 1442980G1C User manual

ADTRAN

ADTRAN 1442980G1C User manual

ADTRAN Express 6500 Series Instruction Manual

ADTRAN

ADTRAN Express 6500 Series Instruction Manual

ADTRAN ISU 512E User manual

ADTRAN

ADTRAN ISU 512E User manual

ADTRAN HTU-C User manual

ADTRAN

ADTRAN HTU-C User manual

ADTRAN Express 6530 6530 Manual

ADTRAN

ADTRAN Express 6530 6530 Manual

ADTRAN GPON 452 User manual

ADTRAN

ADTRAN GPON 452 User manual

ADTRAN T200 HTU-R Instruction Manual

ADTRAN

ADTRAN T200 HTU-R Instruction Manual

ADTRAN NxT1 HSSI/V-35 User manual

ADTRAN

ADTRAN NxT1 HSSI/V-35 User manual

ADTRAN TA 900 User manual

ADTRAN

ADTRAN TA 900 User manual

ADTRAN P/N 1204011L1 Service manual

ADTRAN

ADTRAN P/N 1204011L1 Service manual

ADTRAN NetVanta 2300 User manual

ADTRAN

ADTRAN NetVanta 2300 User manual

ADTRAN TR OCU DP Instruction Manual

ADTRAN

ADTRAN TR OCU DP Instruction Manual

ADTRAN NetVanta T1/FT1 + DSX-1 User manual

ADTRAN

ADTRAN NetVanta T1/FT1 + DSX-1 User manual

ADTRAN DSU 5600 User manual

ADTRAN

ADTRAN DSU 5600 User manual

Popular Network Hardware manuals by other brands

socomec SNMP Card II quick start guide

socomec

socomec SNMP Card II quick start guide

NVR SYSTEMS 4-CH user manual

NVR SYSTEMS

NVR SYSTEMS 4-CH user manual

Draytek VigorSwitch G1240 quick start guide

Draytek

Draytek VigorSwitch G1240 quick start guide

Westermo TD-34 LV installation manual

Westermo

Westermo TD-34 LV installation manual

LaCie Network Space MAX Quick install guide

LaCie

LaCie Network Space MAX Quick install guide

ZoneVu ZSI-450-IP Installation guide & user manual

ZoneVu

ZoneVu ZSI-450-IP Installation guide & user manual

QNAP Turbo NAS Application notes

QNAP

QNAP Turbo NAS Application notes

OpenEye MV Series quick start guide

OpenEye

OpenEye MV Series quick start guide

Huawei SmartAX MT880a quick start guide

Huawei

Huawei SmartAX MT880a quick start guide

Proxim Tsunami QuickBridge 2454-R installation guide

Proxim

Proxim Tsunami QuickBridge 2454-R installation guide

Bay Networks CLAM quick start guide

Bay Networks

Bay Networks CLAM quick start guide

Innodisk SATADOM-SH 3SE Series manual

Innodisk

Innodisk SATADOM-SH 3SE Series manual

Cisco CGR 1000 Series Getting connected guide

Cisco

Cisco CGR 1000 Series Getting connected guide

Matrix Switch Corporation MSC-HD161DEL product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-HD161DEL product manual

National Instruments NI 653x user manual

National Instruments

National Instruments NI 653x user manual

B&B Electronics ZXT9-IO-222R2 product manual

B&B Electronics

B&B Electronics ZXT9-IO-222R2 product manual

Yudor YDS-16 user manual

Yudor

Yudor YDS-16 user manual

D-Link ShareCenter DNS-320L datasheet

D-Link

D-Link ShareCenter DNS-320L datasheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

U-BR1TE
ISDN 2B1Q INTERFACE
U-BR1TE
FEATURES
• Conforms to ANSI T1.601-1992
• Plugs into WECO D4 Channel Bank, ADTRAN
BR1/8 BR1TE bank, and ACT 1241
• Designed for use in SLC-96 terminals
• Basic Rate 2B+D service
• Faceplate Bantam jacks for maintenance testing
• TR-NWT-000397 3 DS0 format and T1 facility
performance monitoring
• Loopback features available on faceplate
• 18,000 ft. nominal range, mixed gauge
• U-BR1TE/MLT supports Mechanized Loop Testing
BENEFITS
• Extends range of 2-wire U-interface using T carrier
• Suitable for both Central Office and customer
premises environments
• UseofD4bankaddsflexibilityandextendslifeofD4
equipment
DESCRIPTION
The ADTRAN U-BR1TE is a device which enables
transport of ISDN Basic Rate (2B+D) information over T
carrierlines. Thisisaccomplishedbytheinsertionofthetwo
"B"channelsat64kbpsandasingle "D"channelat16kbps
into 3 DS0 time slots. The U-BR1TE provides a standard
U-interface which operates at 160 kbps full duplex over a
single twisted pair of wires. The U-BR1TE may be used at
both the Central Office Terminal location (COT) and the
RemoteTerminallocation(RT). ClearChannelcapabilities
(B8ZS) are not required of the T1 facility if Zero Byte
Suppression is enabled. The U-interface available at the
U-BR1TE conforms to ANSI standards and performs all
Layer 1 functions.
The U-BR1TE plugs into a single D4 channel slot. It
occupiesthetimeslotinwhichitisinserted,andthenexttwo
adjacent time slots when delivering 2B+D service. The
U-BR1TE meets the ones density requirement of the T
carrier through the use of zero byte substitution and
associated flags in the “D” channel DS0 slot according to
TR-NWT-000397.
Maintenance and testability is provided for on the
U-BR1TE's front panel. A four-character display provides
an indication of Loop Activation, Out-of-Service, and Test.
The Select button is used with the four-character display to
determinewhichnetworkelementistobeloopedback. The
B1-B2 switch determines which channel is to be looped
back. The LP-CR switch determines the direction of the
loopback. The Test button, which activates the unit's test
features, is recessed to prevent any inadvertent operation.
The U-BR1TE/MLT contains the same capabilities as
the U-BR1TE, with the addition of compatibility with
MechanizedLoopTesting(MLT3.0/ISDN)accordingtoTR-
NWT-000397, Issue 3, June 1992. When configured and
installed in a SLC-96 channel bank, the U-BR1TE/MLT
allows testing the local loop cable drop using an Extended
Pair Gain Tester (XPGTC).
APPLICATIONS
The ADTRAN U-BR1TE is suitable for use in both
Central Office and customer premises environments. The
use of a single wire pair for full-duplex operations greatly
simplifies the administration of cable plant. The capability
oftheU-interfacetoservemixedwiregauges,andnominal
distances up to 18,000 ft. make it the universal choice for
ISDN deployment.
The ADTRAN U-BR1TE is ideally suited when the
need arises to extend ISDN service beyond the normal
ISDN BR1/8 Bank (BR1/8)
TheADTRANBR1/8BR1TE bankprovidesanalternative
means of housing the ADTRAN U-BR1TE or T-BR1TE and
providesnetworkterminationforaT1line. TheBR1/8contains
eight channel slots to accommodate up to eight U-BR1TEs or
T-BR1TEs. Each channel slot contains three DS0 timeslots
allowing all of the channel slots to be used when delivering
ISDNBasicRate(2B+D)Service. TheBR1/8isaneconomical
means to offer ISDN Basic Rate via T carrier. Mounting slots
areprovidedforeightcommonequipmentcards:aPAU,PCU,
OIU-2, RU, LIU, ACU, TU, and CAU. It is available in 23-inch
mounting.
servicing range. The ability to provide ISDN services
is only limited by the range of available T carrier lines.
In instances where the 2B1Q U-interface card is
not available in the digital switch, it is possible to use
ADTRAN T-BR1TEs and U-BR1TEs in a mixed
application. Thisapplicationallowsthe2B1QT1.601-
1992 U-interface to be delivered from a digital switch
which does not yet support it.
U-BR1TE Applications
LOCAL EXCHANGE
18,000 FT.
LOCAL EXCHANGE
18,000 FT.
D4 (BR 1/8)
U-BR1TE
CHANNEL
BANK
D4 (BR 1/8)
U-BR1TE
CHANNEL
BANK
D4 (BR 1/8)
U-BR1TE
CHANNEL
BANK
D4 (BR 1/8)
U-BR1TE
CHANNEL
BANK
NT1
NT1
U
LT
T
NT
I
S
D
N

S
W
I
T
C
H
U
T
U
U
Loop Interface:
Line: 2-Wire (TIP and Ring)
Operating Mode: Full-duplex
Data Rate: 160 kbps total; 144 kbps available to customer
Signal Format: 2B1Q
Output Amplitude: 2.5 Volt, Zero-to-Peak
Tx Source Impedance: As per ANSI T1.601-1992
Rx Source Impedance: As per ANSI T1.601-1992
Receiver Sensitivity: As per ANSI T1.601-1992
DS1 Facility Interface: Fully compatible with WECO D4 Channel Bank Equipment
Network Compatibility: ISDN and other digital service, according to TR-NWT-000397
Faceplate Controls and Indicators:
Controls: B1/B2 Bearer channel Select switch
LP/CR Loop or carrier direction Select switch
Select Scrolls through valid loopback addresses on four-character display
Test Activates selected loopback
Indicators: Four-character display is used to select loopback address and display loopback status.
Test: Bantam test jacks for TPI 108/109 RT II or equivalent test sets
Mechanical:
Size: 4.4" H x 10" D x 1.4" W
Weight: 10 oz.
Mounting: Mounts in WECO D4 Channel Bank/SLC-96 terminals
Power: Current Drain On-Card Dissipation
-48 V: 40
m
A (in LUNT mode) 1.95 W maximum
5V: 5
m
A Display OFF (normal operating mode)
45
m
A Display ON
ORDERING INFORMATION: The part numbers for the U-BR1TE are provided below.
Equipment Part Number
U-BR1TE 1100020L1
U-BR1TE MLT 1100020L2
BR1/8 BR1TE BANK 1150018L1
U-BR1TE SPECIFICATIONS
901 Explorer Boulevard • Huntsville, Alabama • 35806-2807 • (205) 971-8000 • FAX (205) 971-8699
Display Interpretation
ACTV IN PROG Activation in progress, the 2-wire loop is attempting to activate.
LOOP lS DOWN The 2-wire loop is not activated.
ADR# LOOP BACK A distant unit with address # is in a loopback commanded from this card.
NT1 LOOP BACK The NT1 is in loopback as commanded from this card.
B1 LOOP BACK This card is currently looping back channel B1 as commanded from a far unit.
B2 LOOP BACK This card is currently looping back channel B2 as commanded from a far unit.
2B+D LOOP BACK This card is currently looping back all channels as commanded from a far unit.
BANK CR FAIL Bank carrier fail, the channel bank is not receiving data from the T carrier.
XMIT CR SIDE Transmit carrier side, forcing the injection of 64 kbps data into a Bearer channel from the front panel Bantam jack into the carrier direction.
XMIT LP SIDE Transmit loop side, forcing the injection of 64 kbps data into a Bearer channel from the front panel Bantam jack into the loop direction.
MADE B1 LPBK Made B1 loopback, manually forced the Bearer channel B1 loopback in both the network and customer directions.
MADE B2 LPBK Made B2 loopback, manually forced the Bearer channel B2 loopback in both the network and customer directions.
CHCK TEST SET Check test set, ensure test set Tx probe is properly inserted into faceplate Bantam jack and configured as NEAR LOGIC.
FAR END OPEN The unit on the far end of the carrier is not present or not configured properly.
61100.020L1-8C
August 1993
Printed in U.S.A.
Specifications subject to change without notice.