
1Section 61245201L1-5, Issue 361245201L1-5C
FNID and T200 FNID
Fractional T1 Network Interface Device
Installation and Maintenance
CONTENTS
1. GENERAL ............................................................................ 1
2. INSTALLATION.................................................................. 2
3. CONNECTIONS................................................................... 3
4. DSL SYSTEM TESTING .................................................... 4
5. CONTROL PORT OPERATION......................................... 4
6. DSL DEPLOYMENT GUIDELINES ................................. 11
7. TROUBLESHOOTING PROCEDURES ........................... 12
8. MAINTENANCE ................................................................ 12
9. PRODUCT SPECIFICATIONS .......................................... 12
10. WARRANTY AND CUSTOMER SERVICE .................... 12
Appendix A. FT1 Loopbacks ................................................... A-1
FIGURES
Figure 1. ADTRAN FNID ...................................................... 1
Figure 2. FNID Option Switch Locations .............................. 2
Figure 3. FNID Network Loop Connection Locations .......... 4
Figure 4. RS-232 (DB9) Pin Assignments ............................. 4
Figure 5. Introductory Menu Screen ...................................... 7
Figure 6. HDSL Main Menu Screen ...................................... 7
Figure 7. Current System Status Screen................................. 8
Figure 8. Performance History Screen ................................... 8
Figure 9. Loopback Options Screen ....................................... 9
Figure 10. Self Test Options Screen ........................................ 9
Figure 11. Provisioning Options Screen ................................. 10
Figure 12. Troubleshooting Screen ......................................... 10
Figure 13. DSL Deployment Guidelines................................. 11
Figure A-1. FT1 Loopbacks .................................................... A-1
Figure A-2. FT1 DP Network Loopback ................................. A-1
Figure A-3. FT1 DP CPE Loopback ....................................... A-1
Figure A-4. FT1 Repeater #1 or # 2 Network Loopback ........ A-2
Figure A-5. FNID Network Loopback .................................... A-2
Figure A-6. FNID CPE Loopback ........................................... A-2
TABLES
Table A. Front Panel Functions ............................................. 3
Table B. FNID Card Edge Pin Definitions ........................... 3
Table C. Definition of Screen Abbreviations ........................ 5
Table D. Loop Insertion Loss Data....................................... 11
Table E. Troubleshooting Guide .......................................... 12
Table F. FNID Unit Specifications ...................................... 13
Table A-1. FT1 Loopback Select Codes ................................ A-3
1. General
This practice is an installation and maintenance (I/M)
guide for the ADTRAN Fractional T1 Network
Interface Device (FNID). Figure 1 is an illustration of
the ADTRAN FNID.
Revision History
This practice has been reissued to reflect additional
support detail for two FT1 repeater applications.
The ADTRAN FNID is a network terminating unit
used to deploy a fractional T1 circuit using 2-wire
metallic facilities on CSA loops. This practice is
written to support both the T200 FNID circuit pack
(P/N 1245201L1) and the FNID standalone
(P/N 4245201L1) units.
The FNID is housed in a standalone metal enclosure.
The T200 FNID card plugs into a standard Type
200/400 multiple mounting shelf.
Section 61245201L1-5C
Issue 3, September 1999
CLEI Code: NCDIFBH4 _ _
Trademarks:Anybrandnamesandproductnamesincludedinthisdocumentare
trademarks, registered trademarks, or trade names of their respective holders.
Figure 1. ADTRAN FNID
DSL
FNID
1245201L1
DS1
SF
AMI
(GRN)
(GRN)
ESF
B8ZS
(YEL)
(YEL)
LBK
LOC
L
B
KREM
R
S
2
3
2
TX
RX
M
O
N