EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Advance acoustic
  6. •
  7. Accessories
  8. •
  9. Advance acoustic PIR3 User manual

Advance acoustic PIR3 User manual

Other Advance acoustic Accessories manuals

Advance acoustic AXESS 3 AIR User manual

Advance acoustic

Advance acoustic AXESS 3 AIR User manual

Advance acoustic SUCCESS 5 User manual

Advance acoustic

Advance acoustic SUCCESS 5 User manual

Advance acoustic AXESS 3 AIR User manual

Advance acoustic

Advance acoustic AXESS 3 AIR User manual

Advance acoustic AXESS 4 User manual

Advance acoustic

Advance acoustic AXESS 4 User manual

Advance acoustic BIPRO4 User manual

Advance acoustic

Advance acoustic BIPRO4 User manual

Advance acoustic SUCCESS 4 User manual

Advance acoustic

Advance acoustic SUCCESS 4 User manual

Advance acoustic EASINESS 2 User manual

Advance acoustic

Advance acoustic EASINESS 2 User manual

Advance acoustic Progress 3 User manual

Advance acoustic

Advance acoustic Progress 3 User manual

Advance acoustic BiPro3 User manual

Advance acoustic

Advance acoustic BiPro3 User manual

Advance acoustic Easiness 3 User manual

Advance acoustic

Advance acoustic Easiness 3 User manual

Advance acoustic FRONTCONTAINER ZIP LIGHT User manual

Advance acoustic

Advance acoustic FRONTCONTAINER ZIP LIGHT User manual

Advance acoustic Lightness 2 User manual

Advance acoustic

Advance acoustic Lightness 2 User manual

Advance acoustic iMPRESS 2 User manual

Advance acoustic

Advance acoustic iMPRESS 2 User manual

Advance acoustic BIPAX2 Parts list manual

Advance acoustic

Advance acoustic BIPAX2 Parts list manual

Advance acoustic LIGHTNESS 3 User manual

Advance acoustic

Advance acoustic LIGHTNESS 3 User manual

Advance acoustic IMPRESS 3 User manual

Advance acoustic

Advance acoustic IMPRESS 3 User manual

Advance acoustic AXESS 4 User manual

Advance acoustic

Advance acoustic AXESS 4 User manual

Popular Accessories manuals by other brands

Hillco 2810 Operator's manual

Hillco

Hillco 2810 Operator's manual

Siemens QSA2700D Basic documentation

Siemens

Siemens QSA2700D Basic documentation

Contours ZY024 manual

Contours

Contours ZY024 manual

Saivod VS621 manual

Saivod

Saivod VS621 manual

SCE ENVIRO-THERM SCE-TE170B24VSS user manual

SCE

SCE ENVIRO-THERM SCE-TE170B24VSS user manual

Z-Wave HSD-200Z user manual

Z-Wave

Z-Wave HSD-200Z user manual

turck FMX-IM-2UPLI63FX quick start guide

turck

turck FMX-IM-2UPLI63FX quick start guide

Decagon Devices 10HS manual

Decagon Devices

Decagon Devices 10HS manual

UPPAbaby Cup Holder user manual

UPPAbaby

UPPAbaby Cup Holder user manual

Elko SmartSensor Leakage Wireless manual

Elko

Elko SmartSensor Leakage Wireless manual

Grizzly H8371 instructions

Grizzly

Grizzly H8371 instructions

Panasonic HG-T Series user manual

Panasonic

Panasonic HG-T Series user manual

IFM Electronic Efector 250 Series Brief instructions

IFM Electronic

IFM Electronic Efector 250 Series Brief instructions

Virtuox VirtuCLEAN 2.0 user manual

Virtuox

Virtuox VirtuCLEAN 2.0 user manual

DigiDesign 888/24 I/O installation guide

DigiDesign

DigiDesign 888/24 I/O installation guide

PROZIS QUAY user manual

PROZIS

PROZIS QUAY user manual

patagonia PSI Vest user manual

patagonia

patagonia PSI Vest user manual

SFC Energy EFOY GO! manual

SFC Energy

SFC Energy EFOY GO! manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

PIR3
Instruction
Welcome to use SSEN/CS/ST/WH infrared motion sensor!
This ceiling mounted PIR sensor utilizes a good sensitivity detector and integrated circuit for
energy-saving, safety and practical functionality. It utilizes infrared technology to detect movement of
the human body and will switch on the load once someone enters the detection field. It has an inbuilt
photocell to detect between day and nighttime operation.
SPECIFICATION:
Power Source: 110-240V/AC Detection Range: 360°
Power Frequency: 50/60Hz Detection Distance: 8m max(<24℃)
Ambient Light: <3-2000LUX (adjustable) Working Temperature: -20~+40℃
Time Delay: Min.10sec±3sec Working Humidity: <93%RH
Max.7min±2min Power Consumption: approx 0.5W
Rated Load: Max. 400W (220-240V/AC) Installation Height: 2.2-4m
200W (110-130V/AC) Detection Moving Speed: 0.6-1.5m/s
200W (220-240V/AC)
100W (110-130V/AC)
FUNCTION:
➢Can identify day and night: The installer can adjust the switching point at different ambient light
levels. It can operate in both day and night when the dial is set to the “sun” position (max). It
can work at night only when the dial is set towards the “3” position (min). As for the adjustment
pattern, please refer to the testing pattern.
➢Time-Delay is extended continually: During periods of continued occupancy, the sensor will
restart the time delay with each detection of movement.
Good sensitivity Poor sensitivity
INSTALLATION ADVICE:
As the detector responds to changes in temperature, avoid the following situations:
➢Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
➢Avoid mounting the detector near heat sources, such as heating vents, air conditioning units,
lights etc.
➢Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall
plants etc.
CONNECTION:
⚫Must be installed by a competent person.
⚫Disconnect power source.
⚫Cover or shied any adjacent live components.
⚫Ensure device cannot be switched on.
⚫Check power supply is disconnected.
➢Twist the cover in an anti-clockwise direction to remove.
➢Connect the power and the load according to the wiring
diagram.
➢Fix the sensor to the surface as required.
➢Twist and lock the cover back into position, turn on the power
and check the sensor functionality.
WIRING DIAGRAM (See the below image)
SENSOR INFORMATION:
TEST:
➢Turn the TIME knob anti-clockwise to the minimum (-).
Turn the LUX knob clockwise to the maximum (sun).
➢Switch on the power; the sensor and its connected
lamp will have no signal at the beginning. After a 30sec
warm-up period, the sensor will be operational. If the
sensor detects movement, the load will turn on. When
no further movement is detected, the load should switch off within 10sec±3sec.
➢Turn LUX knob anti-clockwise to the minimum (3). If the ambient light is more than 3LUX, the
sensor will switch the load off. If the ambient light is less than 3LUX (darkness), the sensor will
switch on the load. With no occupancy detected, the sensor will stop working within 10sec±
3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor may not work!
TROUBLESHOOTING:
➢The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is operational
c. Please check the light level setting.
➢The sensitivity is poor:
a. Please check if the sensor is obstructed from detecting movement.
b. Please check if the ambient temperature is too high.
c. Please check if the movement is in the detection field.
d. Please check if the installation height corresponds to the height required in the
instruction.
➢The sensor does not turn off the load automatically:
a. Please check if there is continual movement in the detection field.
b. Please check if the time delay is set to the maximum duration
c. Please check if the wiring corresponds to the instruction.
Height of installation:2.2-4m
Detection Distance: Max.8m