Advanced Energy MONROE 282H User manual

©2021 Advanced Energy Industries, Inc.
The Monroe 282H 200 kV/cm range digital Stat-ArcTM fieldmeter
is a pocket-sized, non-contacting static meter for consistently
accurate readings. Simply hold the instrument so the range
finder LED beams from a non-pulsing circle indicating you're
at exactly the right distance from the target for readings up to
2000 V.
PRODUCT HIGHLIGHTS
200 kV range
Exclusive Auto-Zero circuit
Hold button captures transient readings
Chopper-stabilized measurement technique works in the presence of ionization
Recorder output and 40-hour battery
Drift-free accuracy even in ionized environments
Optional Charge Plate System for testing ionization systems
TYPICAL APPLICATIONS
Monitoring "static-free" electronic workstations
Measuring static build-up on webs in converting, laminating, and printing operations
Checking grounds and bonding in dry particle/power transport systems
Normal Range
0 to ±199.9 V @ 1 ft
Accuracy
±5% of reading, + zero offset,
±2 LSD
Response Time
80 to 100 msec, 10 to 90%
HIGHLIGHTS
MONROE 282H
Pocket-sized, easy-to-use 200 kV non-contacting static
meter which produces consistently accurate readings.
2 advancedenergy.com
MONROE ELECTROSTATIC FIELDMETER 282H
TECHNICAL DATA
Performance Specifications
Display LCD 3 ½-digit with auto polarity readout, with hold and low battery indicators
Range 0 to ±199.9 V at 1 ft
For reading voltages under 20kV, decrease the distance to the target per the following:
kV Distance Divide Reading By
0 to 20 kV 1.0 in 4
Accuracy ±5% of reading, + zero offset, ±2 LSD
Analog Output Amplitude 1 V signal denotes 100 kV reading at 1 in for high impedance loads
Response Time Typical 80 to 100 msec 10 to 90%
Mechanical Specifications
Dimensions (L x W x H) 6.1 x 10.7 x 2.3 cm (2.4 x 4.2 x 0.9 in)
Weight 0.14 kg (0.31 lb) with battery
Jack Type Accepts standard 2.5 mm (3/32 in) monaural phone plug
Electrical Specifications
Battery 9 V NEDA #1604 or equivalent
Battery Life 40 hours of normal use, with alkaline battery
Environmental Specifications
Operating Temperature 0 to 50°C (32 to 122°F)
Relative Humidity 0 to 85% noncondensing
Ionized Unaffected by ionized equipment
advancedenergy.com 3
MONROE ELECTROSTATIC FIELDMETER 282H
1. Turn the instrument ON.
2. Discharge your body by touching a grounded metal object.
3. Point the aperture toward a grounded object and press the ZERO button.
4. Aim the aperture toward the target surface at a distance of 1ft. Adjust the distance until the flashing beams of the
LEDs inthe instrument converge. Read the voltage and polarity of the charged surface on the meter display.
For additional measurements, repeat step four.
Maintenance
The battery should be replaced annually, whenever you plan an extended period of unattended monitoring, or
whenever "BAT" appears on the display for more than an instant. To obtain accurate and drift-free readings, the
sensor plate and especially the area around the aperture must be kept absolutely clean at all times. Never touchthe
aperture with anything—not even a cotton swab.
EASY-TO-USE OPERATION
DS TITLE
For international contact information,
visit advancedenergy.com.
sales.support@aei.com
+1.970.221.0108
ABOUT ADVANCED ENERGY
Advanced Energy (AE) has devoted more than three
decades to perfecting power for its global customers. AE
designs and manufactures highly engineered, precision
power conversion, measurement and control solutions
for mission-critical applications and processes.
Our products enable customer innovation in complex
applications for a wide range of industries including
semiconductor equipment, industrial, manufacturing,
telecommunications, data center computing, and
medical. With deep applications know-how and
responsive service and support across the globe,
we build collaborative partnerships to meet rapid
technological developments, propel growth for our
customers, and innovate the future of power.
Specifications are subject to change without notice. Not responsible
for errors or omissions. ©2021 Advanced Energy Industries, Inc. All rights
reserved. Advanced Energy®, Monroe Electronics®, Stat-ArcTM, and AE® are
U.S. trademarks of Advanced Energy Industries, Inc.
ENG-ESD-Monroe-282H-235-01 1.21

Other Advanced Energy Measuring Instrument manuals

Advanced Energy LumaSense Technologies E2T QUASAR Series User manual

Advanced Energy

Advanced Energy LumaSense Technologies E2T QUASAR Series User manual

Advanced Energy 1314 User manual

Advanced Energy

Advanced Energy 1314 User manual

Advanced Energy 1316 User manual

Advanced Energy

Advanced Energy 1316 User manual

Advanced Energy Impac 600 Series User manual

Advanced Energy

Advanced Energy Impac 600 Series User manual

Advanced Energy 2818A User manual

Advanced Energy

Advanced Energy 2818A User manual

Popular Measuring Instrument manuals by other brands

AimTTi PSA3605 instruction manual

AimTTi

AimTTi PSA3605 instruction manual

Ono Sokki SE-2400 instruction manual

Ono Sokki

Ono Sokki SE-2400 instruction manual

EGAmaster 51251 operating instructions

EGAmaster

EGAmaster 51251 operating instructions

Metrix PX 110 user manual

Metrix

Metrix PX 110 user manual

Co2meter 77597 Operation manual

Co2meter

Co2meter 77597 Operation manual

PerkinElmer Lambda 365 installation instructions

PerkinElmer

PerkinElmer Lambda 365 installation instructions

Bin Master PROCAP I Series operating instructions

Bin Master

Bin Master PROCAP I Series operating instructions

TAS TA120 Series instruction manual

TAS

TAS TA120 Series instruction manual

FRO­NIUS Smart Meter TS Series operating instructions

FRO­NIUS

FRO­NIUS Smart Meter TS Series operating instructions

GeoSIG GMS plus Quick user manual

GeoSIG

GeoSIG GMS plus Quick user manual

Air Weigh LOADMAXX installation guide

Air Weigh

Air Weigh LOADMAXX installation guide

Master cool 89660 operating instructions

Master cool

Master cool 89660 operating instructions

EGAmaster 62981 operating instructions

EGAmaster

EGAmaster 62981 operating instructions

Sen Source PC-PIR15 installation guide

Sen Source

Sen Source PC-PIR15 installation guide

Long-run LRF-2000S user manual

Long-run

Long-run LRF-2000S user manual

Promax RANGER mini user manual

Promax

Promax RANGER mini user manual

Ntron Yellow Box user manual

Ntron

Ntron Yellow Box user manual

Excell NC RACER EX-2001 user manual

Excell

Excell NC RACER EX-2001 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.