Aegis EL-RG-4M User manual

Operation and display panel
1.PRODUCT APPLICATION DESCRIPTION
ECS-180 neo temperature controller could be used in the middle and low
temperature medicine cabinet, kitchen cabinet, supermarket split cabinet, air
curtain cabinet, island counter, wine cabinet, etc.
The controller adopts building block design concept and users could select defrost,
fan, light/external alarm according to their demand.
The function of evaporator sensor, condenser sensor, door switch and buzzer is
optional.
Refrigeration relay output could reach to 30A/240VAC, which could directly drive single-
phase 1.5Hp compressor.
2. INDICATOR LIGHT STATUS DESCRIPTION
Indicator light Symbol Status Meaning
Setting Set
ON Parameter setting
OFF Status of temperature
measuring and controlling
Refrigeration
ON Refrigeration work
Flash Refrigeration stop
Defrost
ON Refrigeration time delay
OFF Defrost work
Fan
ON Defrost stop
OFF Fan work
Defrost dripping drip
ON Fan stop
OFF Start defrost dripping
Dor switch
ON Cabinet door open
OFF Cabinet door close
3. PARAMETER LIST
Menu Functions Setting range Default Unit
Common user menu
St Temperature set value Upper limit ~ Lower Limit 4 °C °C/°F
Po Administrator menu Password 00 ~ 99
(password is 55 unmodied)
4 °C °C/°F
Administrator’s menu
C1 Hysteresis value 0.5 °C ~ 9 °C / 1 °F ~ 20 °F 4 °C °C/°F
C2 Compressor start Min. interval 0 ~ 60 5min
C3 Compressor initial start Min.
interval
0 ~ 90 5min
C4 Cabinet sensor calibration -10 °C ~ 10 °C / -20 °F ~ 20 °F 0.0 °C °C/°F
C5 Temperature set lower limit -50 °C ~ temperature set value -2 °C °C/°F
-58 °F ~ temperature set value
C6 Temperature set upper limit temperature set value ~ 85 °C 22 °C °C/°F
-temperature set value ~ 185 °F
C7 Max standby time after
finishi g compressor start
Min. interval
00 ~ 99
0: Max.standby time
calculation is forbidden
9min
C8 Refrigeration Min. running
time
00 ~ 99
0: Refrigeration Min. running
time calculation is forbiden
0min
d1 Evaporator sensor selection 0: Disabled / 1: Enabled 1-
d1 Evaporator sensor calibration -10 °C ~ 10 °C / -20 °F ~ 20 °F 0.0 °C °C/°F
Temperature Controller
ECS-180neo
USER MANUAL
1 Ivybrook Blvd, Unit 145R, Ivyland, PA 18974, USA
Tel: 1-800-796-2344 / Fax: 732 879 0248 WWW.AEGISFRIDGE.COM
EL-RG-4M / EL-RG-4K / EL-F-4K
Medical & Pharmacy Refrigerator/Freezer

Operation and display panel
Wiring diagram Refer to the actual product.
4. KEYS DESCRIPTION
Keys Function Button action
Set
Enter the status of parameter setting Pressing the keys for 3s
Switch between menu and parameter Press the response
Adjust menu and parameters Pressing the keys for 3s
Open/close light
(only valid for the model with light control) Press the response
Upload the data to copy card Pressing the keys for 3s
Adjust menu and parameters Press the response
Download the copy card Pressing the keys for 3s
View evaporator sensor temperature Press the response
Exit from parameter setting Press the response
6. INTERNAL ALARM
Alarm
code Alarm reason
E1 Cabinet temperature sensor failure
E2 Evaporator sensor failure
E3 Condenser sensor failure
cH Condenser high temperature alarm
rH Cabinet high temperature alarm
rL Cabinet low temperature alarm
Er Copy card programming failure
EP Inconsistent data between copy card and controller, programming failure
Temperature Controller
ECS-180neo
USER MANUAL
1 Ivybrook Blvd, Unit 145R, Ivyland, PA 18974, USA
Tel: 1-800-796-2344 / Fax: 732 879 0248 WWW.AEGISFRIDGE.COM
5. KEYS OPERATION
In the status of temperature measuring and controlling, press Set key for three
seconds to enter user menu, it displays the code St, then press Set key again, display
the value of St. It could be modified y pressing the key or .
When it displays the code St, press the key display the code Po, then press Set key,
display 00, at this time, press or to input the password of administrator menu.
Press Set key again to confi m the password input, and the controller will
automatically verify the correctness of password. When it passes, it could select
parameter items St, Po, C1, C2……U1 (that is, any parameter items both in the
administrator menu and user manuals) by pressing the key or . Or else, only the
parameters items St and Po available, others could not be displayed.
When the parameter item is selected, press Set key to enter to the setting of the current
item, press or to modify the value, and then press Set key to return to the menu.
Under the status of parameter setting, press key or no key operation within 30s, it
will exit from parameter setting and automatically save the current parameter value.
7. SAFETY RULES
Danger Strictly distinguish the power wire, relay output, sensor down-lead and
data line, and the relay could not be overloaded.
Prohibit connecting the wire terminals without electricity cut-off.
Warning Prohibit using this unit under the environment of over damp, high temp.,
strong electromagnetism interference or strong corrosion.
Notice The power supply should conform to the voltage value indicated in the
instruction, and make sure a steady power supply.
To avoid the possible interference, the sensor down-lead/data line and
power wire should be kept in a proper distance.
When evaporator sensor is installed, the sensor should be well connected
with the copper tube which is 5cm away from evaporator inlet.
EL-RG-4M / EL-RG-4K / EL-F-4K
Medical & Pharmacy Refrigerator/Freezer

EL-RG-4M / EL-RG-4K / EL-F-4K
Medical & Pharmacy Refrigerator/Freezer
USER MANUAL
1 Ivybrook Blvd, Unit 145R, Ivyland, PA 18974, USA
Tel: 1-800-796-2344 / Fax: 732 879 0248 WWW.AEGISFRIDGE.COM
Dear Customer:
Congratulations on your purchase of this product. Like all of our products, this product has also been developed
on the basis of the latest technology and produced using reliable and modern electrical components.
Please take a few minutes before starting operation of the appliance and read the following operating
instructions. Save this manual for further reference.
Many thanks.
All internal adjustments and maintenance must be performed by qualified se vice personnel.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory
or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
CAUTION!
Environmental Protection
Discarded electric appliances are recyclable and should not be discarded in the domestic waste!
Please actively support us in conserving resources and protecting the environment by returning
this appliance to the collection centers(if available).
Important operating and/or maintenance instructions. Read the
accompanying text carefully.
Potential electrical hazards. Only qualified pe sons should perform
procedures associated with this symbol.
Hot surface(s) present which may cause burns to unprotected skin
or to materials which may be damaged by elevate temperatures.
Extreme temperature hazards, hot or cold.
Use special handling equipment or wear special, protective clothing.
Always use the proper protective equipment (clothing,gloves,etc.)
Always use dissipate extreme cold or heat and wear protective clothing.
Always follow good hygiene practices.
Each individual is responsible for his or her own safety.

EL-RG-4M / EL-RG-4K / EL-F-4K
Medical & Pharmacy Refrigerator/Freezer
USER MANUAL
1 Ivybrook Blvd, Unit 145R, Ivyland, PA 18974, USA
Tel: 1-800-796-2344 / Fax: 732 879 0248 WWW.AEGISFRIDGE.COM
Table of Contents
1. Installation......................................................................................................1
1.1 Safety Information....................................................................................1
1.2 Assembly.......................................................................................................2
1.3 Positioning the Medical Refrigerator...........................................2
1.4 Ventilation...................................................................................................3
1.5 Power Supply.............................................................................................3
2. Product description.................................................................................4
3. Operation........................................................................................................5
3.1 Access to power.........................................................................................5
3.2 Setting Temperature..............................................................................5
3.3 Turn on/off the light................................................................................5
4. Cleaning...........................................................................................................5
4.1 Out of service..............................................................................................5
5. Maintenance..................................................................................................6
6. Disposal.............................................................................................................6
If the user’s manual is lost or damaged, you can through our
website to download or contact us by E-mail.
1.Installation
1.1 Safety Information
• All electrical work must be executed by suitably qualified pe sons. When using any electrical appliance, safety
precautions must always be observed.
• Do not use this appliance for other than its intended use. This product is intended for use as a beverage Medical
Refrigerator. Consult your supplier for alternatives.
• Do not cover the front grille or block the rear air entry by placing object up against the cabinet.
• Please close attention, when used by or near children, infi m persons.
• Ensure adequate ventilation.
• Do not probe any openings.
• Do not touch any moving parts or hot surfaces.
• Regulations require that all electrical work be carried out by authorized persons. For your own safety and that of
others please ensure this is done.
• Do not overload the power supply. Always ensure on the rating label. The rating label is located.
• If have any problem, please consult a qualified ele trician. Caution: Never use extension leads or multiple adaptors.
• If the mains supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified a d skilled persons in order to avoid hazard.
•Disconnect the mains power supply before attempting any cleaning, removal of any covers, or maintenance work.
• Do not store explosive substances, such as aerosol cans with flammable p opellant.
• Warning: Do not use mechanical devices or other means to accelerate the defrosting process. Defrosting is
performed automatically.
• Warning: Do not damage the refrigeration circuit.
• Warning: Do not use electrical appliances inside the storage compartment of this appliance.

EL-RG-4M / EL-RG-4K / EL-F-4K
Medical & Pharmacy Refrigerator/Freezer
USER MANUAL
1 Ivybrook Blvd, Unit 145R, Ivyland, PA 18974, USA
Tel: 1-800-796-2344 / Fax: 732 879 0248 WWW.AEGISFRIDGE.COM
1.2 Assembly
•Remove the appliance from the packaging and peel off any protective film rom all surfaces.
• Fit the shelf support clips onto the shelf support strips, making sure that the clips for each shelf are of the
same height and that they are securely engaged on the support strip.
•Unwrapping each shelf carefully, to prevent damaging their protective coating or surface finish
• Position the shelves onto the clips.
Please dispose of all waste packaging appropriately and in accordance
with all local recycling laws.
Note: If the unit has not been stored or moved in an upright position,
let it stand upright for approximately 12 hours before operation.
WARNING! Do not overload the power supply. Always ensure that the
power supply is adequate for the electrical requirements specified on
the rating label and never use extension leads or multiple adaptors.
1.3 Positioning the Medical Refrigerator
• Please position the cabinet carefully being careful not to bump it.
•The power supply fl x exits the Medical Refrigerator at the bottom right hand side (as viewed from the front).
For ease of access; the fl x should be retrieved prior to positioning the Medical Refrigerator in its final location
• The maximum recommended ambient temperature for this Medical Refrigerator is 38°C
• Avoid positioning the appliance in direct sunlight or damp areas.
• Allow adequate space for the door(s) to fully open.
• Ensure that this Medical Refrigerator is positioned on a level surface, so as to allow the door(s) to shut and seal
correctly, as well as to allow proper drainage from the evaporator tray, to prevent any overfl w. If necessary,
adjust the screw feet of the appliance to make it level
1.4 Ventilation
• All models must have clear and unobstructed ventilation from the entire surface area of the front grille.
• The 2 and 3 door models may be built into an enclosure without the need for ventilation other than at the
front.
• The single door of Medical Refrigerators must have a minimum ventilation space of 20mm at sides and rear.
• WARNING:Failure to provide the minimum ventilation space will harm the performance of your Medical
Refrigerator could cause fi e and will invalidate the warranty.
• WARNING:Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for
building in

EL-RG-4M / EL-RG-4K / EL-F-4K
Medical & Pharmacy Refrigerator/Freezer
USER MANUAL
1 Ivybrook Blvd, Unit 145R, Ivyland, PA 18974, USA
Tel: 1-800-796-2344 / Fax: 732 879 0248 WWW.AEGISFRIDGE.COM
1.5 Power Supply
• The Medical Refrigerator uses a three-pin plug which must be well grounded. Never ground the Medical
Refrigerator through a gas pipe, tap water pipe OR the grounded wire of single-phase power supply etc. Never
share same circuit with other appliances. Before plugging in your Medical Refrigerator for the fi st time make
sure the power cable is free from damage and check that your voltage corresponds to that on the serial plate.
• Once plugged in the display will show the temperature inside the Medical Refrigerator and the compressor
will run late on (the indicator light of cooling will be on at the same time ). This temperature is the actual
temperature recorded by the probes inside the Medical Refrigerator and as the fridge cools to the set point
(factory set at 4oC/39oF) so the number on the display will descend accordingly. If power is cut off, wait for at
least 5 minutes before plugging the unit in again to avoid damaging the compressor.
• Front panel display
• Remote alarm connector
• Light switch
• Door switch
• Door
• LED light
• Shelves
•Fan
• Adjustable leg
• Cable port
3.Operation
This product is designed to operate at a recommended ambient temperature not more than 38℃.
3.1 Access to power
• Close the door of the appliance.
3.2 Setting Temperature
• Press down to decrease the set temperature.
• Press up to increase the set temperature.
3.3 Turn on/off the light
The light will turn on while the door is opened and will turn off while the closed.
If you want to turn on the light while you do not open the door, you can turn on the switch.
2. Product description

EL-RG-4M / EL-RG-4K / EL-F-4K
Medical & Pharmacy Refrigerator/Freezer
USER MANUAL
1 Ivybrook Blvd, Unit 145R, Ivyland, PA 18974, USA
Tel: 1-800-796-2344 / Fax: 732 879 0248 WWW.AEGISFRIDGE.COM
4. Cleaning
• WARNING: You must disconnect the plug before cleaning or maintenance.
•Do not use abrasive cleaning agents which may scratch and harm the delicate interior finis es of your appliance.
• Always wipe dry after cleaning.
•An agent or qualified echnician must carry out repair if required.
• When cleaning the storage box, please use a soft cloth or sponge dipped in warm water (neutral detergent
can be added) to clean the storage box.
• It is strictly forbidden to spray and wash with water to avoid affecting the electrical insulation performance.
• It is strictly prohibited to use hard brush, wire brush, detergent, gasoline, banana water, acetone and other
organic solvents, hot water or acid, alkali, etc. to clean the storage box.
4.1 Out of service
• If the storage box is out of service for a long time, the power supply should be cut off and cleaned according to
the above method, and the door should be opened to dry.
• In general, it is not necessary to stop using the storage box for a long time in order to avoid affecting the
service life.
5. Maintenance
If your appliance develops a fault, please check the following table before making a call to the helpline.
Fault Possible Cause Action
The appliance is
not working
The unit is plugged in correctly Check the unit is plugged in
correctly
Plug or lead is damaged Call Our agent or qualified technician
Power supply Check power supply
Internal wiring fault Call Our agent or qualified technician
The appliance
turns on, but the
temperature is too
high or too low
Filter or condenser blocked with dust Clean fi ter or condenser
Doors are not shut properly Check doors are shut and seal are
not damaged
Appliance is located near a heat source or air
fl w to the condenser is being interrupted
Move the appliance to a more
suitable location
Ambient temperature is too high Increase ventilation or move
appliance to a Medical Refrigerator
position
Insufficient ai fl w to the fans Remove any blockages to the fans
Appliance is overloaded Reduce the amount stored in the
appliance
Factory default parameters adjusted Call Our agent or qualified technician
The LED lights not
working
Led light short Leaded damage Call Our agent or qualified technician
The appliance
appear BT alarm
See description below See description below
The appliance is
unusually loud
The appliance is touching a neighboring
object
Check installation position and
change if necessary
The appliance has not been installed in a
level or stable position
Check installation position and
change if necessary
6. Disposal
If in any doubt, please consult your Local Authority, contact us or contact the reseller from whom you purchased
the appliance.

EL-RG-4M / EL-RG-4K / EL-F-4K
Medical & Pharmacy Refrigerator/Freezer
USER MANUAL
1 Ivybrook Blvd, Unit 145R, Ivyland, PA 18974, USA
Tel: 1-800-796-2344 / Fax: 732 879 0248 WWW.AEGISFRIDGE.COM
Certifica e of Quality
Checker:
Checker:
Checker:
This manual suits for next models
2
Table of contents
Other Aegis Temperature Controllers manuals