AEMC DTR 8510 User manual

DIGITAL TRANSFORMER
RATIOMETER (DTR®)
ENGLISH User Manual
8510
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer.
Serial #: ________________________________
Catalog #: 2136.50
Model #: 8510
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
Chauvin Arnoux®, Inc.
d.b.a AEMC®Instruments
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

Digital Transformer Ratiometer DTR
®
Model 8510
1
Table of Contents
1. INTRODUCTION ................................................................................. 3
1.1 International Electrical Symbols................................................4
1.2 DenitionofMeasurementCategories .....................................4
1.3 ReceivingYourShipment..........................................................5
1.4 OrderingInformation.................................................................5
1.4.1 AccessoriesandReplacementParts............................5
2. PRODUCT FEATURES......................................................................... 6
2.1 Description................................................................................6
2.2 ControlFeatures.......................................................................8
2.3 CableIdentication ...................................................................9
3. SPECIFICATIONS ............................................................................. 10
3.1 DTR®8510Specications.......................................................10
3.2 BatteryChargerSpecications ...............................................12
4. DISPLAY FUNCTIONS....................................................................... 13
4.1 ProgramFlow .........................................................................13
4.2 TopLevelMenu ......................................................................13
4.3 CongureInstrument ..............................................................14
4.3.1 SetClock ....................................................................16
4.3.2 SetupNameplate ........................................................17
4.3.3 SelectTestType..........................................................20
4.3.4 Select Test Mode ........................................................20
4.3.5 SelectStorageMode ..................................................21
4.3.6 Select Filter.................................................................22
4.3.7 Erase Memory.............................................................23
4.3.8 SelectLanguage.........................................................24
4.3.9 RestoringFactoryDefaults .........................................25
4.4 Recall Data .............................................................................26
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

2
Digital Transformer Ratiometer DTR
®
Model 8510
5. OPERATION..................................................................................... 28
5.1 PowerUp................................................................................28
5.2 RunningaTest........................................................................29
5.2.1 VT/PTTest ..................................................................29
5.2.2 StoringtheMeasurementRecord...............................31
5.2.2.1 ManualMode........................................................31
5.2.2.2 AutoMode............................................................32
5.2.3 VT/PTExcitationCurrent ............................................32
5.2.4 VT/PTContinuityTest .................................................33
5.2.5 CTTest........................................................................33
5.3 TipsforMakingPreciseRatioMeasurements ........................35
5.4 Ratio Test - 1:1 .......................................................................36
6. CONNECTIONS ................................................................................ 37
6.1 ConnectionDiagrams .............................................................37
6.2 PolyphaseConnections..........................................................38
7. DATAVIEW®SOFTWARE................................................................... 39
7.1 InstallingDataView®................................................................39
7.2 OpeningtheControlPanel .....................................................43
7.3 UsingtheControlPanel..........................................................45
7.4 ConguringtheDTR®8510 ....................................................47
7.5 RunningaTest........................................................................49
7.6 DownloadingaTest ................................................................50
7.7 SavingtheMeasurementRecords .........................................51
7.8 ReportGeneration ..................................................................51
8. MAINTENANCE................................................................................ 53
8.1 ChargingtheBatteries............................................................53
8.2 Cleaning..................................................................................56
APPENDIX: DISPLAY MESSAGES......................................................... 57
Limited Warranty .............................................................................61
WarrantyRepairs ............................................................................61
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

Digital Transformer Ratiometer DTR
®
Model 8510
3
CHAPTER 1
INTRODUCTION
WARNING
These safety warnings are provided to ensure the safety of
personnelandproperoperationoftheinstrument.
• This instrument is protected from accidental voltages of not
morethan50Vwithrespecttoearth.Theguaranteedlevelof
protectionofthisequipmentmaybecompromisedifusedina
mannernotspeciedbythemanufacturer.
• Readtheinstructionmanualcompletelyandfollowallsafety
informationbeforeattemptingtouseorservicethisinstrument.
• TheDigitalTransformerRatiometerDTR®Model 8510 is
designedforuseonde-energized (“dead”) transformersonly.
MakesurethetestsampleiscompletelydisconnectedfromAC
powerandisfully discharged.
• OnlyqualiedpersonnelshouldusetheDTR®8510 .
• TheDTR®8510mustnotbeusedinamannerinwhichanyof
itscomponents(includingtestcables)arereliedupontoprovide
protectionfromelectricshock.Nohighvoltageinsulation/
protectionisprovidedbyanycomponentoftheDTR®8510.
Always make sure the circuit is fully discharged before
attaching any test cables.
• Donottouch,adjust,orrepositiontestcableswhiletheDTR®is
conductingatest.
• Usecautiononanyapparatus:potentiallyhighvoltagesand
currentsmaybepresentandposeashockhazard.
• Safetyistheresponsibilityoftheuser.
• Onlyusethechargingunitsuppliedwiththeinstrumentto
rechargethebattery.
• NeveropentheinstrumentwhileitisconnectedtoACpower
orwhentestcablesareconnectedtotransformers,equipment,
circuits,etc.
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

4
Digital Transformer Ratiometer DTR
®
Model 8510
1.1 International Electrical Symbols
Signifies that the instrument is protected by double or reinforced insulation.
CAUTION - Risk of Danger! Indicates a WARNING and that the operator must
refer to the user manual for instructions before operating the instrument in all
cases where this symbol is marked.
Risk of electric shock. The voltage at the parts marked with this symbol may
be dangerous.
Ground/Earth
Important instructions to read and understand completely.
Important information to acknowledge.
Battery
Fuse
USB socket
Compliance with the Low Voltage & Electromagnetic Compatibility European
directives (73/23/CEE & 89/336/CEE)
In the European Union, this product is subject to a separate collection system
for recycling electrical and electronic components In accordance with directive
WEEE 2002/96/EC
1.2 Definition of Measurement Categories
CAT II: For measurements performed on circuits directly connected to
the electrical distribution system. Examples are measurements on
householdappliancesorportabletools.
CAT III:
Formeasurementsperformedinthebuildinginstallationatthedistri-
butionlevelsuchasonhardwiredequipmentinxedinstallationand
circuitbreakers.
CAT IV: For measurements performed at the primary electrical supply
(<1000V)suchasonprimaryovercurrentprotectiondevices,ripple
controlunits,ormeters.
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

Digital Transformer Ratiometer DTR
®
Model 8510
5
1.3 Receiving Your Shipment
Uponreceivingyourshipment,makesurethatthecontentsareconsistent
withthe packinglist. Notifyyour distributor ofany missingitems. Ifthe
equipmentappearstobedamaged,leaclaimimmediatelywiththecar-
rierandnotifyyourdistributoratonce,givingadetaileddescriptionofany
damage.Savethedamagedpackingcontainertosubstantiateyourclaim.
1.4 Ordering Information
Digital Transformer Ratiometer DTR®Model 8510 ......... Cat. #2136.50
Includes NiMH batteries (installed), 115V power cord, set of two 15 ft leads, 10 ft USB cable,
external battery charger (90-264VAC 50/60Hz), soft carrying case, DataView®software, and
a user manual.
1.4.1 Accessories and Replacement Parts
Fuse-setof5,0.5A250V(5x20mm,SlowBlow) ............... Cat. #2118.53
Fuse-setof5,4A125V(5x20mm,SlowBlow) .................. Cat. #2118.55
Lead-Setof2,30ft............................................................ Cat. #2136.76
Lead-ReplacementSetof2,15ft...................................... Cat. #2136.77
Battery-ReplacementSetof2,12VNiMHrechargeable... Cat. #2136.78
ReplacementBatteryCharger............................................. Cat. #2136.79
ReplacementUSBCable,10ft............................................Cat. #2136.80
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

6
Digital Transformer Ratiometer DTR
®
Model 8510
CHAPTER 2
PRODUCT FEATURES
2.1 Description
The Digital Transformer Ratiometer DTR® Model 8510 is a lightweight,
rugged,portableinstrumentdesignedforonsitetestingofpower,potential
andcurrenttransformers.
OperationoftheDTR®8510isfullyautomatic.Nousercalibration,range
selection,handcrankingortediousbalancingisrequired.
During each test cycle, the DTR®8510 automatically checks for:
• H/Xleadreversal
• Continuityoftestedcircuits/windings(ifcongured)
• Shortcircuitconditions(highcurrent)
Upon completion of a test cycle, the DTR®8510 displays:
• Turns Ratio:Theratiooftheprimarytosecondaryvoltageatthe
transformerterminalsduetotestexcitation
• Excitation Current: TheRMSexcitationcurrentintheHwinding
duetotestexcitationduringnegligibleloadingoftheassociated
Xwinding
• Polarity:Indicatesthepolarity(phase)ofXrelativetoH
• Deviation: Indicatesthedeviationfromnameplateratioin%
TurnsRatio,ExcitationCurrent,PolarityandDeviationareusefulparam-
etersindiagnosingandpredictingavarietyoffaultsthatoccurinpower,
potentialandcurrenttransformers.
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

Digital Transformer Ratiometer DTR
®
Model 8510
7
The DTR®8510 will display the following messages:
• IncorrectLeadConnections
• H/XReversal(accidentalstep-upmisconnection)
• Short(excessexcitationcurrent)
• OpenCircuits
• CircuitContinuity
• LowBattery
Inaddition,theDTR®8510allowstheusertostorethedatainautomatic
ormanualmodeaftereachtesteliminatingtheneedtowritedownthetest
results. Each measurement record is date and time stamped providing
completetestinformation.
TheusercanalsosaveNameplatevoltagesandcomparetheresultsas
thedataisbeinggathered.ThedatacanlaterbedownloadedtoaPCand
analyzedusingtheDataView®softwarepackagewhichisincludedwith
theproduct.
DataView®allowsfullcontroloftheinstrument.
The DTR®8510 utilizes an advanced, low-voltage, step-down measure-
ment technique in which the high voltage “H” windings are subjected to
test excitation. This results in greater operator safety and the ability to
test a much wider array of transformer types and sizes.
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

8
Digital Transformer Ratiometer DTR
®
Model 8510
2.2 Control Features
50V CAT IV
OFF/
CHARGE
ON
ENTER
MEM
TEST
CONTRAST
DIGITAL TRANSFORMER RATIOMETER
DTR®MODEL 8510
USE SPECIFIED
CHARGER ONLY
USE ONLY ON DE-ENERGIZED TRANSFORMERS
H
X
5
2
1
3
4
6
7
8
10
11
9
1. Display: Displaysdata,statusandcontrolfeaturesoftheinstrument.
2. USB Connector: Allowsconnectiontoacomputerforinstrument
congurationset-upandstatuscheck,downloadingofthestored
datausingtheDataView®softwareandrunningatest..
3. High-side “H” Cable Connector (primary):Connectionforthe
primarysideofthetransformer.
4. Low-side “X” Cable Connector (secondary):Connectionforthe
secondarysideofthetransformer.
5. Battery Charge Input Connector:Allowsthesmartchargerto
chargethebatteries.
6. Power Switch: TurnstheinstrumentONorOFF(ifthechargerisnot
connected).Ifthechargerisconnected,thebatterieschargeinOFF/
CHARGEposition.
7. Operation and Battery Low Indicator: GreenLEDindicatesthat
theinstrumentisonandblinkswhenthebatteriesaregettinglow
(<12V).Theinstrumentwillcompletelyshutdownwhenthebatteries
arebelow8.7V.
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

Digital Transformer Ratiometer DTR
®
Model 8510
9
8. Display Contrast Adjustment: Allowsadjustmentofthedisplay
contrast.
9. Function Keys:Allowsnavigationofthemenuandfunctionsofthe
instrument.
10. Backlight ( ) Control Button:TurnsthedisplaybacklightONor
OFF.
11. Test Button: Runstheselectedtestwhenpressedandreleased.
2.3 Cable Identification
H CABLE SET
RED INLINE PLUG
BLACK INLINE PLUG
"H" IDENTIFIER
5 PIN
CONNECTOR
"H" IDENTIFIER
X CABLE SET
RED INLINE PLUG
BLACK INLINE PLUG
"X" IDENTIFIER
3 PIN
CONNECTOR
"X" IDENTIFIER
H
H
XX
Primary (H) Cable:
Secondary (X) Cable:
Eachcableisclearlymarked.ThePrimary(H)cablehasa5-pinconnector
and the Secondary (X) cable has a 3-pin connector. They cannot
inadvertently be connected incorrectly.
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

10
Digital Transformer Ratiometer DTR
®
Model 8510
CHAPTER 3
SPECIFICATIONS
Reference Conditions: 23°C±5°C(30to50%RH)range.Add 25ppm /°Cfrom-10°to
18°Cand28°to50°Ctoallaccuracyspecications.Noexternalelectricalormagneticelds.
Outputcurrent≤150mAforVT/PTand≤50mAforCT.Calibrationcycleis1year.
3.1 DTR®8510 Specifications
DTR®8510
ELECTRICAL
Ratio Range (VT/PT) Autoranging: 0.8000 to 8000:1
Accuracy (VT/PT) Ratio Range Accuracy (% of Reading)
0.8000 to 9.9999 ± 0.2%
10.000 to 999.99 ± 0.1%
1000.0 to 4999.9 ± 0.2%
5000.0 to 8000.0 ± 0.25%
Ratio Range (CT) Autoranging: 0.8000 to 1000.0
Accuracy (CT) Ratio Range Accuracy (% of Reading)
0.8000 to 1000.0 ± 0.5%
Excitation Signal VT/PT Mode: 32Vrms max
CT Mode: Auto Level 0 to 1A, 0.1 to 4.5Vrms
Excitation Current
Display
Range: 0 to 1000mA
Accuracy: ± (2% of Reading + 2mA)
Excitation Frequency 70Hz
Display Dual line alpha-numeric LCD, 16x2 characters with contrast
adjustment and backlight control. Day/night visible.
Measurement Method In accordance with IEEE Std C57.12.90™-2006
Power Source Two 12V, 5x2, 1650mAH NiMH rechargeable battery packs
Battery Life Up to 10 hrs of continuous operation. Low battery indication.
Battery Charger Universal input (90 to 264Vrms input) smart recharger
Charging Time <4 hrs
Data Storage 99 objects with 99 tests each
Date/ Time Battery-backed, Real-time clock
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

Digital Transformer Ratiometer DTR
®
Model 8510
11
Communication USB. 2.0 compliant, optically isolated, 115.2 KB
Software DataView®analysis software included
MECHANICAL
Dimensions 10.70 x 9.76 x 5.12" (272 x 248 x 130 mm)
Weight 8.1 lbs (3.7kg)
Connection XLR connectors
Leads 15 ft (4.6m) H & X shielded with large color-coded
industrial alligator clips in carrying bag
Enclosure Heavy duty Polypropylene case, UL 94 V0
Vibration IEC 68-2-6 (1.5mm to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
Index of Protection IP 40 (Instrument lid open) per EN 60529
IP 53 (Instrument lid closed) per EN 60529
ENVIRONMENTAL
Operating Temperature 14° to 122°F (-10° to 50°C)
Storage Temperature -4° to 140°F (-20° to 60°C)
Relative Humidity 10 to 85% RH @ 35°C
Altitude Up to 2000 meters (6560 ft)
SAFETY
Safety Rating EN 61010-1; 50V CAT IV; Pollution Degree 2
Double Insulated Yes
Specications are subject to change without notice.
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

12
Digital Transformer Ratiometer DTR
®
Model 8510
3.2 Battery Charger Specifications
DTR®8510 BATTERY CHARGER
ELECTRICAL
No-load Voltage 41V ±2V
Fast Charge Current 0.9A ±70mA
Top-off Charge 130mA ±40mA
Charge Termination Options -dV, dT/dt
Input Rating 90 to 264VAC /47 to 63Hz
Maximum Output Power 35W
Trickle Charge Current 50mA ±25mA
Leakage Current
(from battery with mains off) <1mA
MECHANICAL
Dimensions 4.22 x 2.64 x 1.44" (107 x 67 x 36.5mm)
Weight 0.55 lbs (250g)
Input Connection 2-pin IEC 320-C7
Output Connection NiMH: 3 PIN DIN
ENVIRONMENTAL
Operating Temperature -4° to 104°F (-20° to 40°C)
SAFETY
Insulation Class II
Electrical Safety Approval EN 60601-1, EN 60950, EN 60335-2-29
EMC Standards EN 61000-6-3 (Emission), EN 61000-6-1 (Immunity)
Specications are subject to change without notice.
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

Digital Transformer Ratiometer DTR
®
Model 8510
13
CHAPTER 4
DISPLAY FUNCTIONS
4.1 Program Flow
Inordertousetheinstrumentefciently,itisimportanttounderstandthe
programow.
• Pressingthe▼and▲keyssimultaneouslyallowsgoingupone
level(ifthereisalevel)intheprogramow.
(Verticalnavigationmovingupalevel).
• Pressingthe▼or▲keyallowsnavigationwithinthelevel.
(Horizontalnavigation).
• PressingtheENTERkeyallowstheselectionanddisplayofchoices
onelevelbelow(ifthereisalevel)intheprogramow.
(Verticalnavigationmovingdownalevel).
4.2 Top Level Menu
TheinstrumenthasatoplevelcontrolasshowninFig.4-1.
Theusercannavigatearoundtheringbypressingthe▼or▲key.
Main Screen
Recall Data
Configuration
Figure 4-1
Oncetheinstrumentisturnedon,itinitializesandthendisplaystheMain
Screen:
Figure 4-2
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

14
Digital Transformer Ratiometer DTR
®
Model 8510
• Main Screen: DisplaystheTestType,TestMode,Filter[Fast(F),
Normal(N)orSlow(S)],StorageMode[Auto(A)orManual(M)]and
thePresentNameplatevalues(ifenabled).
• CongureInstrument:Congurestheinstrument(see§4.3).
• Recall Data: Storeddatacanbeselectedanddisplayed(see§4.4).
NOTE: The program flow is two or three levels deep at various points.
The available choices for a level can be viewed by pressing the ▼or
▲keys.
TheENTERkeyisusedtoselectthefollowingfunctions:
• Entercongurationmenu.
• EnterRecallDatamenu.
• Initiatestorageoftestresults,acceptlocationparametersandstore
theMeasurementRecord.
4.3 Configure Instrument
With the display showing Congure Instrument, press the ENTER key.
Thecongurationring(seeFigure4-4)canbenavigatedaroundusingthe
▲or▼key.
Figure 4-3
• Set Clock: AllowsthesettingofTimeandDate.
• Setup Nameplate: AllowsselectionandeditingofPresent
Nameplatevoltagesorratios.Predenedratioscanonlybeedited
throughDataView®.
• Select Test Type: AllowstheselectionofTestType(VT/PTorCT).
• Select Test Mode: AllowsselectionoftheTestMode(Ratioor
Continuity/RatioinVT/PTMode).
• Select Storage Mode: Allowstheselectionofdatastoragemode
(AutomaticorManual).
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

Digital Transformer Ratiometer DTR
®
Model 8510
15
• Select Filter: Allowsselectionoflter(Fast,Normal,Slow).
See§4.3.6.
• Erase Memory: Allowsdeletionofallthestoredmeasurement
records
• Select Language: Allowsselectionoflanguageonthedisplay
(English,French,German,Italian,Spanish,Portuguese)
NOTE: To move one level up and return to Configure Instrument, press
the ▼▲keys simultaneously.
Set
Clock
Select
Storage Mode
Setup
Nameplate
Select
Language
Select
Test Type
Erase Memory
Select
Test Mode
Select
Filter
Figure 4-4
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

16
Digital Transformer Ratiometer DTR
®
Model 8510
4.3.1 Set Clock
1. WithinthetoplevelofCongure Instrument,pressthe▼or▲key
untilSet Clock appearsonthedisplay,thenpressENTER.
Figure 4-5
TheSet Clock congurationallowsyoutoformatthefollowing:
Date Format:Allowstheformattingofthedate.
(MM/DD/YY,DD/MM/YY,YY/MM/DD).
Figure 4-6
Time Format:Allowstheformattingofthetime(12or24hours).
Figure 4-7
Set Date and Time:Allowsthesettingofthedateandtimeintheselected
format.
Note: Timemustbesetinthe24-hourformat.ItwillbedisplayedwithAM/
PMifthe12-hourformatischosen.
Figure 4-8
Example: Tosetthetimeto2:50PM,setthehourto14andtheminutes
to 50.
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

Digital Transformer Ratiometer DTR
®
Model 8510
17
TomaneuverbetweentheSet Clockcongurationsettings,performthe
following:
1. WithinthetoplevelofCongure Instrument,pressthe▼or▲key
untilSet Clockappearsonthedisplay,thenpressENTERtocongure
thedate.
2. Usethe ▼ or▲ keys toview the choices.Press ENTER tomake
aselection.Oncetheformatisselected,thedisplayreturnstoDate
Format.
3. Usethe▼or▲keystonavigatetotheotherdateandtimeoptionsor
pressboth▼▲keystogethertoreturntothetoplevel.
4.3.2 Setup Nameplate
Nameplatevaluesareprimaryandsecondaryvoltages(orratios)associated
with a given transformer.This information is available on the Nameplate
ofthetransformer.Themeasuredresultswillbecomparedwithselected
(edited)NameplatevaluesandDeviationwillbedisplayedandstoredin%
relativetothesevalues.
The DTR® 8510 allows the storage of 10 Nameplate voltages or ratios
whichcanbeindividuallyselectedforagiventest.
NOTE:
• TheNameplatelistofupto10transformerscanbewrittentoand
savedonlyusingDataView®software.Thevaluesinthelistcan
beeditedforusebutcannotbesavedfromthefrontpanel.
• Thekeysonthefrontpanelcanselectanyoneofthe10
transformerNameplatevalues.Oncethetransformervalues
areselected,theycanbeeditedtoanewvalueusingthe▼,
▲andENTERkeys.Whenthenewvaluesareselected(even
iftheyarenoteditedtonewvalues),itbecomesthePresent
NameplateandwillbeusedforallsubsequentVT/PTandCT
measurements.Deviationwillbereportedandstoredusingthese
values.
• ThePresentNameplatevalueswillberetainedinmemoryeven
iftheinstrumentisturnedOFFandturnedON.However,itwill
notbesavedinthelistfromwhichitwasoriginallyselected.
• TheusercanselectanotherNameplatefromthelistinthe
futureandmayormaynoteditthevalues.Assoonasthenew
Nameplatevaluesareselected(and/oredited),itbecomesthe
newPresentNameplate.
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412

18
Digital Transformer Ratiometer DTR
®
Model 8510
• ThePresentNameplatevaluesaredisplayedintheMain
Screen.
• EachMeasurementRecordwillrecordthePresentNameplate
alongwithotherassociatedparametersandwillbeavailable
whenthedataisdownloaded.
• TheRatioofthenameplatevaluesmustbebetween1and
32767.
• TheNameplateneedstobeenabled.IftheNameplateis
notenabled,theDeviation%willnotbereportedafterthe
measurements.Subsequently,thestoredvalueswillnothave
NameplateandDeviation%intheMeasurementRecord.
NOTE: The Main Screen will display the Present Nameplate only if
it is Enabled. If it is not Enabled, it will display "---" for Primary and
Secondary.
TocongurethesettingsfortheNameplate,performthefollowing:
1. WithinthetoplevelofCongure Instrument,pressthe▼or▲key
untilSetup Nameplate appearsonthedisplay,thenpressENTER.
Figure 4-9
2. ThedisplaywillshowEnablewithYes and Nochoices.Pressthe▼
keytoselectYes(EnableNameplate).
Figure 4-10
www.ShopAEMC.com
Shop for AEMC products online at: 1.877.766.5412
Table of contents
Other AEMC Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

E+E Elektronik
E+E Elektronik EE671 user manual

Underground Magnetics
Underground Magnetics MAG 3S manual

Morskate
Morskate DH 010 FPM Installation and operating instructions

EZCast
EZCast CatchU B1 quick start guide

PCB Piezotronics
PCB Piezotronics IMI SENSORS 624B61 Installation and operating manual

Omega
Omega DP41-B Series Operation manual