If you are using double-sided tape, wipe the two surfaces clean of any oil or dust with a damp towel. When the surface 
has completely dried, peel one side of the tape back and attach it to the corresponding section on the rear side of the 
mounting plate.
You can choose each of way from these 2 installations above. Just need to note if the environment temperature of the 
garage door is less than 0   ,  we suggest to choose the rst way (using screws to afx the mounting plate) that would 
be more stable.
4. Lock your Sensor on the mounting plate.
Press and hold the Latch Button, and then push the Sensor into the mounting plate.
After completing all installation steps, you may need to test your Garage Door Controller to see if it has been 
successfully installed. You can implement this via short pressing the Switch Button on the Garage Door Controller. 
When you press the Switch Button, you will see the alarm LED blink and ring the alarm sound. After about 5 seconds, 
the garage door will move to a full open or closed position. If you press the Switch Button again, the garage door will 
immediately stop moving. If not, please check or repeat the steps above.
Note: If  you have conrmed  the installation is  successful, you need to  calibrate the Sensor  once. For detailed 
calibration steps, please refer to  the “Conguration Parameter 34” in the engineering spec  document of Garage 
Door Controller.
The following instructions will tell you how to remove your Garage Door Controller from your Z-Wave network via an 
Aeotec by Aeon Labs’ Z-Stick or Minimote controller. If you are using another Z-Wave controller as your main controller, 
please refer to their respective manual on how remove devices from your network.
If you’re using a Z-Stick:
If your primary controller is missing or inoperable, you may wish to reset your Garage Door Controller to its default 
factory settings. To do this, press and hold the Z-Wave Button for 20 seconds and then release it. Your Garage Door 
Controller will now be reset to its original settings, and the Network LED will be solid for 2 seconds and then start slow 
blinking to conrm a success.
Model Number: ZW062
Power Supply: 5V DC Adapter for Garage Door Controller.CR2 Lithium battery 3V, 800mA for Sensor.
Max Alarm Power: 2W.
Max Standby Power: 1W.
Max Volume: 105dB.
Operating Temperature:-10 to 45 .
Storage Temperature:-20 to 70 .
Supported Audio Formats: MP3 within 320 Kbps or WAV at 1411 Kbps.
Operating Distance: Up to 980 feet/300 metres outdoors.
1. If your Z-Stick is plugged into a gateway or a computer, unplug it.
2. Takeyour Z-Stick to your Garage Door Controller.
3. Press the Action Button on your Z-Stick.
4. Press the Z-Wave Button on your Garage Door Controller.
5. If your Garage Door Controller has been successfully removed from your network, its Network LED will blink. If the 
removal was unsuccessful, the Network LED will not blink.
6. Press the Action Button on the Z-Stick to take it out of removal mode.
If you’re using a Minimote:
1. Take your Minimote to your Garage Door Controller.
2. Press the Remove Button on your Minimote.
3. Press the Z-Wave Button on your Garage Door Controller.
4. If your Garage Door Controller has been successfully removed from your network, its Network LED will blink. If the 
removal was unsuccessful, the Network LED will not blink.
5. Press any button on your Minimote to take it out of removal mode.
Removing your Garage Door Controller from a Z-Wavenetwork.
Reset your Garage Door Controller.
Advanced functions.
Technicalspecications. 
Warranty.
Aeon Labs warrants to the original purchaser of Products that for the Warranty Period (as dened below), the Products 
will be free from material defects in materials and workmanship. The foregoing warranty is subject to the proper 
installation, operation and maintenance of the Products in accordance with installation instructions and the operating 
manual supplied to  Customer. Warranty claims must be  made by Customer  in writing within thirty  (30) days of the 
manifestation of a problem. Aeon Labs' sole obligation under the foregoing warranty is, at Aeon Labs' option, to repair, 
replace or correct any such defect that was present at the time of delivery, or to remove the Products and to refund the 
purchase price to Customer. 
The "Warranty Period" begins on the date the Products is delivered and continues for 12 months. 
Any repairs under this warranty must be conducted by an authorized Aeon Labs service representative and under 
Aeon Labs' RMA policy. Any repairs conducted by unauthorized persons shall void this warranty.
Excluded from the warranty are problems due to accidents, acts of God, civil or military authority, civil disturbance, war,
strikes, res, other  catastrophes, misuse, misapplication, storage  damage, negligence, electrical power  problems, or 
modication to the Products or its components. 
Aeon Labs does not authorize any person or party to assume or create for it any other obligation or liability in 
connection with the Products except as set forth herein. 
Aeon Labs will pass on to Customer all manufacturers’ Material warranties to the extent that they are transferable, but 
will not independently warrant any Material.
Customer must prepay shipping and transportation charges for returned Products, and insure the shipment or accept 
the risk of loss or damage during such shipment and transportation. Aeon Labs will ship the repaired or replacement 
products to Customer freight prepaid.
Customer shall indemnify, defend,  and hold Aeon Labs  and Aeon Labs' afliates,  shareholders, directors, ofcers, 
employees, contractors, agents and other representatives harmless from all demands, claims, actions, causes of 
action, proceedings, suits, assessments, losses, damages, liabilities, settlements, judgments, nes, penalties, interest, 
costs and expenses  (including fees and  disbursements of counsel) of  every kind (i) based  upon personal injury or 
death or injury to property to the extent any of the foregoing is proximately caused either by a defective produc t 
(including strict liability in  tort) or by the negligent or  willful acts or omissions of Customer or its ofcers, employees, 
subcontractors or agents,  and/or (ii) arising from or  relating to any actual or  alleged infringement or misappropriation 
of any patent, trademark, mask work, copyright, trade secret or any actual or alleged violation of any other intellectual 
property rights arising from or in connection with the products, except to the extent that such infringement exists as a 
result of Aeon Labs' manufacturing processes.  
IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL
DAMAGES, OR  DAMAGES FOR LOSS  OF PROFITS, REVENUE,  OR USE INCURRED  BY CUSTOMER OR ANY THIRD  PARTY, 
WHETHER IN AN ACTION IN CONTRACT, OR TORT, OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.  
AEON LABS' LIABILITY AND  CUSTOMER'S EXCLUSIVE REMEDY FOR ANY  CAUSE OF ACTION ARISING IN  CONNECTION WITH 
THIS AGREEMENT OR THE SALE OR USE OF  THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH 
OF WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES,  IS EXPRESSLY LIMITED TO, AT AEON LABS' OPTION, 
REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH 
DAMAGES ARE CLAIMED.  ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF 
PRODUCTS SHALL BE DEEMED  WAIVED UNLESS MADE IN WRITING  WITHIN THIRTY (30) DAYS FROM AEON LABS'S  DELIVERY, 
OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF NONDELIVERY. 
THE INDEMNITY AND  WARRANTY IN ABOVE ARE EXCLUSIVE AND  IN LIEU OF ALL  OTHER INDEMNITIES OR  WARRANTIES, 
WHETHER EXPRESS  OR IMPLIED, INCLUDING  THE IMPLIED WARRANTIES  OF MERCHANTABILITY AND FITNESS  FOR A 
PARTICULARPURPOSE. 
FCC NOTICE(for USA)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
THE MANUFACTURER  IS NOT RESPONSIBLE  FOR ANY RADIO  OR TV  INTERFERENCE CAUSED  BY UNAUTHORIZED 
MODIFICATIONS TO THIS  EQUIPMENT.SUCH MODIFICATIONS COULD  VOID THE  USER’S AUTHORITY TO OPERATE THE 
EQUIPMENT.
STORE INDOORS WHEN  NOT IN USE. SUITABLE FOR  DRY LOCATIONS. DO NOT IMMERSE IN  WATER. NOT FOR USE WHERE 
DIRECTLY EXPOSED TO WATER.
This device may not cause harmful interference, and 
This device must accept any interference received, including interference that may cause undesired operation. This 
equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of 
the FCC Rules. These limits are designed to provide rea son abl e prot ectio n a gai nst ha rmful interference in a 
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio communications. However, 
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following measures: 
1
2
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consul the dealer or an experienced radio/TV technician for help.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local government for information regarding the collection systems available.
Warning
Certications (regional):
Z-Wave and Z-Wave Plus 
are registered trademarks 
of Sigma Designs and its 
subsidiaries in the United 
States and other countries
     Version:501005600002-AA                                                                                                                    www.aeotec.com
6
C
C C
C
C
System Operation.
Operation Notes.
1. USE THE MOBILE APPS TO CONTROL YOUR GARAGE DOOR, VIEW STATUS, AND SET CUSTOM RULES
2. THE GARAGE DOOR CONTROLLER WILL BEEP AND FLASH FOR FIVE SECONDS BEFORE THE DOOR MOVES
3. THE CONTROLLER WILLACTIVATE THE DOOR OPENER AND OPEN OR CLOSETHE DOOR
4. THE MOBILE APP WILL SHOW THE NEW STATUS OF THE DOOR AFTER THE DOOR COMPLETES ITS CYCLE
1. The Alarm LED will blink and the Speaker System will sound for 5 seconds before the door opener is activated. 
STAY CLEAR OF THE DOOR, AND DOOR OPENER. THEY ARE ABOUT TO MOVE!
2. If the door does not completely open or close after remote activation, you need to calibrate the Sensor again. For 
detailed calibration steps, please refer to the “Configuration Parameter 34” in the engineering spec document of 
Garage Door Controller.
Changes or modications  not expressly approved by the  manufacturer could void the  user’s authority to operate the 
equipment.
1. Use the Micro USB cable to connect Garage Door Controller to your PC host. Your PC host will detect the removable 
storage after a few seconds, and then you will nd it in the section of “Device with Removable Storage.
2. Double click the “CD Drive(G:) NEW” to open the storage.
3. Run the “MusicDownload.exe”.
4. Click the “Select Sound” tab on the menu, and then click the “Select Sound” button, which will open a new pop up 
a window. Now you can select/choose the alarm sounds from your hard disk to update into Garage Door Controller’s 
ash memory.
5. Click “Update” button and wait a few minutes to complete the updating.
Note: 
1. Please do not disconnect the USB port until the update has completed. 
2. The new ringtones will overwrite all of the old ringtones after the update is complete.
Download new alarm sounds to your Garage Door Controller from your PC host.