AFIX FAST FIX User manual

FAST FIX
ACCESS LADDERS
ASSEMBLY GUIDE
AS9999/323, 07-2015

221-07-2015
AS0006/XXX
Ledgers
AS0001/XXX
Adjustable base
plate
AS0003/XXX
AS0004/XXX
Standards
AS0050/257
Alu. platform
stair
AS0050/300
Stair guard rail
AS0050/520
Internal
guard rail
AS0010/XXX
Diagonal braces
2m hoog
AS0032/XXX
Steel decks
The AFIX FAST FIX system scaold is tested according to the norms:
NBN EN 12810-1, NBN EN 12810-2, NBN EN 12811-1, NBN EN 1288-2,
NBN 1288-3
This means that the AFIX FAST FIX scaold may be used in:
Austria, Belgium, the Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary,
Iceland, Ireland, Italy, Luxembourg, Malta, the Netherlands, Norway, Portugal, Slovakia, Spain,
Sweden, Switzerland and the United Kingdom.
AS0050/400
Stairway guard
rail adapter
AS0002/000
Collar

21-07-2015 3
ASSEMBLY INSTRUCTIONS
PSet up the scaffold only under safe weather conditions.
PAlways use a harness, helmet, gloves and safety shoes.
PWe recommend EVERYONE to attend a course about erecting scaffolds.
P
Do not let anyone, who has not read the user guide thoroughly, work with or on the scaold.
PAll components should be checked for damage at the time of assembly.
Damaged components should be repaired by certified personnel or destroyed.
PStudy the FAST FIX assembly and user guide.
1a Fit the collars over the
adjustable base plates and
swivel the wing-nut (+50mm)
upwards.
1b Place the complete base
plane. Connect collars using
ledgers. Use the small holes
of the rosette for right-angle
connections. If necessary, put
wood, concrete or a steel
plate under each adjustable
base plate.
2
Level the base plane in
longitudinal and cross direc-
tion. Level the base commen-
cing at the highest point of
the ground, by adjusting the
wing nut.
1a
1b
2
Before you start:
Study this assembly and user guide completly.
If you have any questions, you can contact us
without obligations.

421-07-2015
ASSEMBLY INSTRUCTIONS
3Place the 3m standards
in the collars of the base.
4At a height of 2m, fit
ledgers in longitudinal and
cross direction.
5Place the first alu. plat-
form stair and slide it to the
outside of the scaold.
3
4
5

21-07-2015 5
6
Mount a ledger as the
first guard rail in the 1st ro-
sette 0.5m above the plat-
form stair. Subsequently,
mount your 2
nd
guard rail
0.5m higher. Place 2 stairway
guard rail adapters at a height
of 0.5 and 1.0m.
7
Slide the internal
guard rail over internal
beam of the platform stair
and srew on the bolt-nut
connections. Place the stair
guard rail at the top edge
over the ledgers and at the
bottom over the guard rail
adapters. Knock the wedge
connections with a hamer.
8Fix diagonal braces all
4 sides. Insert the wedges in
one of the big holes of the ro-
sette. Mounting the first dia-
gonal in place of the bottom
platform 0.5m heigher, result
in a better passage.
6
7
8
ASSEMBLY INSTRUCTIONS

621-07-2015
9
Place another 2.0m
standards on each 3.0m
standard.
10 Mount the necessary
ledgers at 2.0m above the 1st
platform stair.
11 Mount the next plat-
form stair in opposite direc-
tion.
12 Mount at one side 2 led-
gers at 0.5 an 1.0m above the
platform level.
9
10
11
12
ASSEMBLY INSTRUCTIONS

21-07-2015 7
13 Fit the platform stair
with a internal- and stair
guard rail. Be sure that all the
guard rails are secured.
14 Fix diagonal braces all
4 sides. Repeat step 9-14 un-
til you reach the required
height.
15 Mount 2 steel decks
next to the platform stair.
Important: Secure every
deck with lock against lift-o.
16 Create with ledgers a
knee and hip guard rail.
13
14
15
16
ASSEMBLY INSTRUCTIONS

821-07-2015
ATTENTION: Anchoring only to solid constructions or buidings.
PBasic rules for access ladders who can’t be anchored:
PMaximum height open air construction: 3x smallest base width (3x1.40=4.20m).
PMaximum height construction in closed rooms 4x smallest base width (4x1.40= 5.60m).
When you need more height, widening the base of the access ladder to comply the basic rules.
CONSTRUCTION VARIANTS
Awhen you need a access ladder who can lift up secure the standards with locking clips.
Afix advise customers to use standards with dismantable spigot. The special Fast FIX-fix-
ture prevent losing collars and adjustable base plates during lift up.
BFor a higher or lower exit level it is recommended to start with a platform stair 0.5, 1.0 or
1.5m height.
CCombine platform stairs 0.5, 1.0 or 1.5m height with platform stairs 2.0m, height, makes it
possible to create a step out every 2.5 or 3.0m.

21-07-2015 9
België:
Durmelaan 20
9880 Aalter
België
Tél. +32 9 381 61 01
Fax +32 9 381 61 00
E-mail info@afixgroup.com
Nederland:
Koopvaardijweg 6
4906 CV Oosterhout
Nederland
Tél. +31 162 43 51 51
Fax +31 162 43 98 28
E-mail info@afixgroup.com
Mauritius:
C/O Interface Management Services LTD
9th Floor, Raes Tower 19
Cybercity, Ebene
Maurice
Tél. +230 404 6030
Mob +230 499 0920
E-mail info@afixgroup.com
Turkije:
Ofis/Depo adres: Orhanlı merkez Mah. Dervişsok.
No: 24/1
PK 34956 Orhanlı/Tuzla Gat Lojistik Genel
Müdürlük binası
VD: TUZLA / VN: 0080773715 SİCİL NO: 781569
Tél. +90 216 639 40 08
Fax +90 0216 639 40 09
E-mail info@afixgroup.com
Marokko:
Hayati AVCI
Route de Sidi Bouzid / O.C.P
El Jadida
Tél. +212 523 383 952
E-mail info@afixgroup.com
Qatar:
Sanam Services WLL
(Bin Arbaid Group)
P. O Box 60072, Al Khor, Qatar.
Tel.: +974 4472 1849
+974 4472 1875
Mob.: +974 6679 3307
Fax +974 4472 2680
E-mail
manager[email protected]
Nigeria:
14th floor, Churchgate Tower, AfriBank Road,
Victoria Island, Lagos E-mail info@afixgroup.com
Romania and Bulgaria:
FET International Services SRL
Strada Turnului nr. 5
500152 Braşov, Romania
Mob. +40 727 82 39 82
Tel. +40 368 46 95 45
E-mail info@fet-is.eu
eli.koster@fet-is.eu
Table of contents
Popular Ladder manuals by other brands

zarges
zarges ZAP Safemaster S Assembly and use instructions

Misterstep
Misterstep TECH CE installation instructions

Clarke
Clarke TL-2C Operation & maintenance instructions

Instant
Instant Span 300 Assembly guide

Stromberg Carlson Products
Stromberg Carlson Products LA-401 installation instructions

Instant Upright
Instant Upright Span 400 manual