Mile End Business Park, Oswestry, Shropshire SY10 8NN Tel. 0870 758 4000 Fax. 0870 758 4010 www.aico.co.uk
E &OE Our policy is one of continuous improvement. Ei205ENA DataSht Rev 0 29.03.10
We reserve the right to amend designs and specifications without prior notice.
Product Description
The Ei205ENA is a Carbon Monoxide (CO) Alarm that runs on
battery power. It has a sealed in tamper proof batteries
designed to last 5 years (the life of the alarm).
The alarm has a high performance electrochemical sensor to
sense CO presence.
The alarm has an integrated pattress and screws for easy wall or
ceiling mounting.
Operation
 The green light will flash once every 40 seconds to show
power is present.
 The alarm will sound and the red indicator will flash at
different speeds to indicate the presence of various levels of
CO gas (see overleaf).
 The alarm will beep every 40 seconds to indicate the
battery is depleted and the unit needs replacing.
 The alarm will beep and the amber indicator will flash every
40 seconds to indicate a fault on the sensor.
 The ‘Test/Hush’ button will either silence false alarms (if
briefly pressed) or perform a unit self test (if pressed and
held). Note that the alarm cannot be silenced when sensing a
CO level of 300ppm or above.
 Memory Feature—after the unit as been in alarm, the red
indicator will flash every 40 seconds at a rate indicating the
CO level previously detected.
Battery Powered
Carbon Monoxide Alarm
 Proven Electrochemical sensor
 Tamper Proof battery cover
 Memory feature records if Carbon Monoxide (CO) has been
detected
 Easy to use Test/Hush button
 Pre alarm LED gives early warning of CO
 Advanced suppression and calibration technology
 Low power cell warning
 Loud distinctive alarm sound (85db (A) at 3 metres)
 Power, alarm and fault indicator lights
 Kitemarked to BS EN50291:2001
 5 Year Guarantee
Model Ei205ENA
Technical Specification
1. The CO Alarm carries the BSI Kitemark to indicate type testing to BS EN 50291:2001. It is CE marked to indicate conformance to BS EN 60065: 1994,
BS EN 50081-1: 1992 and BS EN 50270: 1992 Safety and Electromagnetic Compatibility Directives.
2. New generation electrochemical cell type Carbon Monoxide sensor checks CO concentration every 50 seconds. Each unit is calibrated and tested in CO
gas in order to ensure accuracy.
3. High level of selectivity. No false alarms when exposed to the following interference gases for 2 hours: (as per UL2034sec.38) Methane 500ppm, Butane
300ppm, Heptane 500ppm.
4. Battery powered; supplied with 3 long life alkaline AA batteries. Battery compartment is sealed to prevent unauthorised battery removal. The green LED
on the cover will flash and alarm will beep to indicate if the unit needs replacement.
5. Tamperproof battery compartment - white locking rivets supplied.
6. Supplied with integral mounting base and fixing screws: suitable for ceiling or wall mounting.
7. Start up sequence - the green, red and amber LEDs will flash once, after 20 seconds the green LED will flash every 4 seconds for a further 45 seconds.
The red LED will then flash once to indicate that the alarm is in full operation. Rapid warm up time - only 70 seconds to full operation.
8. Green LED power indicator light flashes once every 40 seconds to confirm integrity of battery power supply.
9. Low and high level indicators - red LED indicator light flashes every 2 seconds at 50ppm CO (sounder operates within 60-90 mins); flashes twice every
second at 100ppm CO (sounder operates within 10-40 mins); flashes 4 times per second at 350ppm CO (sounder operates within 3 minutes)
10. Fault indicator - amber LED flashes and horn beeps every 40 seconds if a fault is detected.
11. Manual Test/Hush button - press and hold the Test/Hush button to test circuitry and horn. Pressing and releasing the Test/Hush button when the unit is
sensing CO will silence the alarm for 4 minutes. It will only silence once until the gas clears. At 300ppm CO the unit cannot be silenced due to the in-
creased danger.
12. Quick CO gas test - allows quick and easy testing of the unit with CO gas. Pressing the Test/Hush button causes the sensor to test for CO every 4 sec-
onds. The unit
automatically resets after approximately 3 minutes.
13. Memory feature - pressing the Test/Hush button records if CO has been detected during a period of absence: red LED off – no CO recorded; Red LED
flashes twice (every 40 seconds) – 50ppm CO recorded, red LED flashes 4 times (every 40 seconds) – 100ppm, red LED flashes 8 times (every 40 seconds) -
300ppm CO recorded. Pressing the Test/Hush button for 20 seconds resets the memory.
14. Built in sounder to give a minimum output of 85dB(A) at 3 metres. Modulated sound output - 3 rapid pulses followed by a 1½ second pause, repeated
until reset. This easily differentiates it from a typical smoke alarm.
15. Automatic reset of alarm test function and after an alarm state when CO gas clears.
16. Operating temperature range: -5°C to +40°C (23°F - 104°F). 15% to 95% relative humidity.
17. Dimensions: 135mm x 105mm x 42mm. Weight: 260g.
18. 5 year guarantee (covers the alarm and batteries).
19. Manufactured in Ireland.
Mile End Business Park, Oswestry, Shropshire SY10 8NN Tel. 0870 758 4000 Fax. 0870 758 4010 www.aico.co.uk
E &OE Our policy is one of continuous improvement. Ei205ENA DataSht Rev 0 2903.10
We reserve the right to amend designs and specifications without prior notice.
Aico Ltd is a wholly owned subsidiary of Ei Electronics
Europe’s Leader in Residential Fire + Gas Detection
Ei Electronics, Shannon, Ireland
Made in
Ireland
Model Ei205ENA

Other Aico Security System manuals

Aico RadioLink Ei208DWRF User manual

Aico

Aico RadioLink Ei208DWRF User manual

Aico 140 Series Instruction Manual

Aico

Aico 140 Series Instruction Manual

Aico RadioLINK Ei450 User manual

Aico

Aico RadioLINK Ei450 User manual

Aico Ei208DW User manual

Aico

Aico Ei208DW User manual

Aico Ei3024 User manual

Aico

Aico Ei3024 User manual

Aico EI169/160 Manual

Aico

Aico EI169/160 Manual

Aico Ei3018 User manual

Aico

Aico Ei3018 User manual

Aico Ei3030 User manual

Aico

Aico Ei3030 User manual

Popular Security System manuals by other brands

Kenwood SPECTRUM 755 AV using manual

Kenwood

Kenwood SPECTRUM 755 AV using manual

SImx CHM0152 installation instructions

SImx

SImx CHM0152 installation instructions

Bosch AMAX 2100 Quick start manual

Bosch

Bosch AMAX 2100 Quick start manual

Honeywell LYNXR Installation and setup guide

Honeywell

Honeywell LYNXR Installation and setup guide

Locstar EM 4102 Operation manual

Locstar

Locstar EM 4102 Operation manual

Yardgard YG03 Installation & operation manual

Yardgard

Yardgard YG03 Installation & operation manual

ADT 3G Cellular Medical Alert System Quick installation guide

ADT

ADT 3G Cellular Medical Alert System Quick installation guide

Bentel Security ECHO manual

Bentel Security

Bentel Security ECHO manual

ERA Protect Replica Siren Installation and operating manual

ERA

ERA Protect Replica Siren Installation and operating manual

Medpage MP5x operating instructions

Medpage

Medpage MP5x operating instructions

Philips LBB 1370 Instructions for use

Philips

Philips LBB 1370 Instructions for use

Honeywell 5816 WMWH manual

Honeywell

Honeywell 5816 WMWH manual

Malmbergs LM-101LD instruction manual

Malmbergs

Malmbergs LM-101LD instruction manual

Smartwares DVR640S quick start guide

Smartwares

Smartwares DVR640S quick start guide

Valcom V-9910-YEL installation guide

Valcom

Valcom V-9910-YEL installation guide

CAME Securityline SRS485 manual

CAME

CAME Securityline SRS485 manual

Honeywell MK V Line maintenance manual

Honeywell

Honeywell MK V Line maintenance manual

HAI Omni Pro II quick reference

HAI

HAI Omni Pro II quick reference

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.