Aico EI169/160 Manual

2
Connecting
to
mains
junction
box.
T
he ma
i
ns lead
w
i
r
es
ar
e
c
o
l
o
ur
c
o
ded as
f
o
l
l
o
w
s
:
T
h
i
s
can be
e
x
te
n
de
d up to
5
0 m (20
o
h
ms ma
x
.
)
w
it
h
su
i
t
-
ab
l
e
l
ow
vol
ta
g
e
cab
l
e
i
f
requi
r
ed. The Smoke
A
l
a
r
m
s
upp
li
ed
w
i
th
the
syste
m m
a
y
be
i
n
te
r
co
nnec
t
ed
wit
h
o
t
h
er
E
i
mai
ns
power
e
d
s
mo
ke
/
h
ea
t
a
l
a
rms up to a
ma
x
i
m
um
o
f
1
2
a
l
a
r
ms
(se
e
be
lo
w for
de
t
a
il
s
)
i
n
t
o
t
a
l.
M
any
dw
e
ll
ing
s
requ
i
r
e
m
o
r
e
t
h
a
n
one
sm
oke
al
a
rm
fo
r
m
i
n
i
m
um
prot
e
c
t
io
n
.
S
ee
t
he
smo
ke
a
l
a
rm
inst
r
uct
i
on
l
eaf
l
e
t
f
o
r
de
t
a
il
e
d
a
d
v
i
ce
o
n,
in
te
r
connec
-
t
i
o
n
,
maint
enan
ce
e
t
c
.
Warning: T
hi
s
ma
i
ns
o
pera
ted
s
y
s
t
em
s
h
o
u
l
d
be
i
ns
t
alled
and
i
n
ter
connne
c
te
d b
y a
q
u
a
l
i
f
i
e
d
e
l
ec
t
r
i
c
i
a
n
i
n
ac
c
o
r
dance
wi
th
the Regulati
on
s
fo
r
E
l
ec
t
ri
ca
l
I
ns
t
a
ll
at
i
on
s
published by
t
h
e
In
s
tit
u
t
e of
E
lec
tr
i
c
al
E
n
g
i
n
ee
r
s
(UK
)
.
F
a
il
u
re
t
o
i
ns
ta
ll
t
h
i
s
sys
t
e
m
correct
l
y
m
ay
ex
po
s
e the
u
ser
t
o
s
ho
c
k
o
r
fi
re
h
az
ard
s
.
Mains
(230V
A
C)
r
ated
cab
l
e
m
u
s
t
be
u
s
ed
fo
r
t
heint
e
r
c
o
nn
ec
t
w
i
re along
wit
h
th
e
m
a
i
ns
itse
l
f
.
Control Panel
Th
e
Con
t
ro
l
Pane
l
sh
ou
l
d
be
p
er
mane
nt
l
y
f
i
xe
d
t
o
t
h
e
w
a
ll
us
i
ng the
sc
re
ws
an
d p
l
a
st
i
c
p
l
ugs
e
n
c
l
ose
d
.
T
h
e
s
c
rew
s
sho
uld be spaced 114 mm
(
4
.
5
i
n
)
v
e
rt
i
c
ally apa
rt
.
T
h
e
t
o
p
screw
s
h
o
uld
b
e
2
7
m
m
(
1.
1
i
n)
b
e
l
o
w
th
e
to
p
s
u
rf
a
c
e of
t
h
e
contro
l
panel
w
hen
i
n
s
talled
.
T
he~
cre
w
s
(l
arge
h
e
ads)
s
h
oul
d
be
scr
ewe
d
i
nto
t
he
w
all
le
av
i
ng a gap of
app
r
ox
i
m
at
el
y
4 m
m
(0.
1
5
i
n)
un
der
t
he
h
ea
d
.
F
i
t t
he
k
e
y
ho
l
e
sl
ots
o
n
t
h
e
ba
ck
o
f
the
cont
rol
panel
ov
e
r
t
h
e
s
c
r
ew
h
eads
an
d
s
l
ide
t
he
pane
l
down vertically
in
t
o
p
os
itio
n.
T
he ma
i
ns
adapt
o
r
c
an be
p
l
ugg
e
d
i
n
t
o
a
s
o
ck
et. T
h
e
s
ock
et
mus
t
no
t
b
e
us
e
d
fo
r
an
y
o
t
he
r
eq
ui
pm
en
t
an
d
i
t
mu
st
a
l
w
a
y
s
be
sw
i
tched on.
It
isprefe
r
a
bl
e to
per
ma
n
e
nt
l
y
w
i
re
t
h
e u
nit
i
n
to
a
m
a
in
s
jun
c
-
t
i
on box.
In
t
h
is
cas
e
r
e
mov
e
t
h
e
p
l
ug and
w
i
r
e as
f
o
l
l
ows
.
Wa
rn
ing:
F
i
rs
t
r
em
o
ve the
po
we
r
to
t
he
c
irc
ui
t a
t
t
he d
is
t
ri
b
u
-
t
io
n
boar
d. If
you are
i
n
a
n
y
do
ubt
about
h
ow
to
do
t
h
i
s
,
get
he
l
p
f
rom a qua
li
f
i
e
d
el
ect
r
ic
i
an.
V
I
BR
A
T
I
ON PAD Ei 174
PA
TTRESS Ei 172/160
1
.
Location
&
Installation
T
h
e Contro
l
Pane
l
s
h
ould
norma
ll
y befixed
suc
h
t
h
at the in-
terna
l
strobe
l
ig
ht
can
be
seen
fr
o
m t
he bed
a
nd
the
vi
b
r
a
t
ion
pa
d
can be placed
u
nder the mattress
o
r
p
i
llow.
I
t
has
to
be
p
owered
f
rom the mains (230 VAC) so a
suitab
l
e power
po
i
nt
or
jun
ction
b
ox
m
ust be availab
l
e
to
wh
i
ch it can be
pe
r
ma-
n
ently
connec
t
ed. The Smoke
A
l
arm must be
l
ocate
d
as de-
sc
ri
be
d
i
n
t
he
Smoke Alarm
i
nstructions suppl
i
e
d
.
Cable (10
m)
i
s
s
u
ppl
i
ed
to
c
o
nnec
t
bet
w
een the Control
Pane
l
and
t
he
·
·
Ei
1
72/160
P
at
t
ress
fo
r
the smoke
a
l
arm.
Ei
171/160
Ei
1
69/
1
60
w
i
th a
Ma
i
ns
Opt
i
cal Smoke
A
l
arm
Ei
1
66
Ei
170/160
E
i
1
69
/
160 wit
h
a
Ma
in
s
Ion
i
sa
t
i
o
n
Smoke
A
l
a
r
m
E
i
161
Intr
od
uc
t
ion
T
h
is
le
afl
et
desc
r
i
be
s
t
he
in
s
t
a
ll
a
t
io
n
o
f t
he
Ei
169/160,
E
i
17
0/160
a
nd
Ei
1
71
/
160 Sys
t
em
s
.
I
m
po
rt
a
nt:
Re
ad
a
ll
i
ns
truc
t
io
n
s
be
fo
re
in
sta
llin
g
.
Thi
s
lea
f
-
l
et
mu
s
t be left wit
h
t
h
e end
u
ser
a
f
t
e
r
i
ns
t
a
ll
at
i
on.
N
.
B.
If
t
he
syste
m
i
s
n
ot
b
e
ing
us
ed
fo
r
s
om
e
t
m
e
t
he
Cont
ro
l
Pa
ne
l
p
ower
s
w
i
t
ch
m
u
s
t
b
e
i
n
t
he off
po
siti
on. Thi
s
w
i
ll
pre
-
vent
t
h
e batt
e
ryfrom
bei
ng
t
ot
all
y
d
epl
et
ed
a
n
d
p
oss
i
bly
da
m-
a
ged
.
D
o n
o
t
turn on
unt
il
i
t
i
s
fu
lly
w
ir
ed.
The
systems consist
of
:
-
Ei 169
/
160
E
i
173
Con
t
r
ol
Pane
l
(with
bu
ilt
in
strobe)
E
i
174
Vi
b
ra
t
o
r
Pad
Ei
172/160
Pa
ttr
ess
fo
r
Smoke
I
Heat
A
l
a
r
m
Interface (t
hi
s
requires
a
n
Easi-tit
A
l
ar
m
to opera
t
e i.e.
E
i
1
40,
1
4
1 ,
14
6,
16
1
or 166)
CONT
R
OLPA
N
E
L
E
i
173
(Wi
th
r
echa
rge
a
bl
e
battery
fo
r
one ':"eek
s
ta
n
dby)
SMOK
E
AL
A
RM
E
i
16
9
/160
B
ASIC
SYSTE
M
(req
uir
es
a
Smoke Alarm
E
i
1
6
1
o
r
E
i
1
66
)
Ei
1
7
0/160
w
ith
M
AI
NS
I
ONISA
TI
ON SMOKE
ALAR
M
Ei
161
E
i
17
1/160
wi
th
M
A
IN
S
OP
TI
CAL
SMOK
E
A
L
ARM Ei 166
Smoke Alarm
Syst
e
ms
for
the Deaf
&
Hard
of
Hear
i
ng
- with Strobe
&
Vibrator
Instruction Leaflet
www.acornfiresecurity.com
www.acornfiresecurity.com

4
8.
Rep
l
ace
t
he
w
i
r
i
ng
c
ov
e
r
o
n
t
he
m
ou
nt
in
g
plat
e
.
Sli
de
t
h
e
Smoke Alarm on
t
o
t
h
e
m
o
un
t
i
g
p
l
at
e
.
InterconnectingSmoke
A!arms
A maximum
o
f
1
2
E
i
14
0
,14
1
,
1
44
,14
5,
1
46
,
1
6
1
,
1
64
,
1
66
Smoke
/
Heat
A
l
arms maybe
int
e
r
co
nn
ec
t
e
d
t
oone Ei
172
/
1
60
un
i
t. When one
a
l
a
rm senses
fi
r
e
a
ll
int
e
r
co
nne
ct
e
d
u
ni
t
s
w
i
ll
so
u
nd and the
co
ntrol
p
ane
l
will
t
u
rn
o
n
t
he
s
t
r
obe light and
v
i-
bra
t
ion pad (See
S
m
ok
e
/
Heat
Ala
r
m
in
st
ru
ctio
n
l
eafl
e
t
f
o
r
f
u
r
-
ther
detail
s on
inter
connect
io
n
....vfr
ing
)
.
W
a
rn
i
ng:
Do
no
t
conne
ct
t
o any other
t
ype
o
f
Smoke
/
H
ea
t
A
l
arm.
Do
i
ng
t
h
is
m
ay
d
a
ma
g
e
t
he
a
l
a
r
ms
an
d
c
o
u
ld
r
esu
lt
i
n
a
shock
o
r fire
da
mage
.
Note
1
:
An
ala
rm
w
i
t
h
b
at
t
e
r
y
b
ack-
u
p
(
i.
e
.
E
i
141
,
144,
1
4
6,
161
,
1
6
4
,
1
66)
w
i
ll
c
o
ntinu
e
t
o
ope
ra
te
du
r
i
ng
m
a
i
n
s
fa
i
l
ure and
w
il
l
be
ab
l
e to
sig
n
a
l
t
h
e
co
nt
ro
l
p
a
n
e
l
if
th
ey
sense
fire
.
The control
pa
n
el
a
l
so
h
a
s battery
ba
c
k-
up
,
so
t
h
at
i
t
t
oo
wi
l l
ope
r
ate during
m
a
in
s
f
ai
l
u
re.
F
i
gu
re 2
/
F
I
X
I
N
G
SC
R
E
WS
W
I
R
IN
G
F
R
O
M
PA
TT
RE
S
S
E
i1
72/
1
6
0
3
.
The
lo
w vo
l
t
age
wi
ring from
th
e
c
o
ntrol
p
a
n
e
l
m
ust
n
o
t
b
e
r
u
n
i
n
t
he same co
n
d
u
it
as
t
he
ma
i
n
s
/
i
ni
e
r
co
n
nect
w
i
res
.
4
.
U
s
i
ng a
sha
r
p
k
ni
f
e
re
mo
v
e
m
a
t
er
i
al from
t
h
e
approp
ri
ate
k
nockouts
mak
i
n
g
s
u
re
tha
t
t
h
ere
i
s
n
o
gap
,
e
i
th
e
r
w
h
e
r
e
m
a
t
ed with
t
he
du
c
tin
g
/
co
nduit or
w
i
th
t
h
e
l
ow
vo
ltage
w
ir
es.
T
here are
thr
e
e
knoc
k
ou
ts
a
n
d
on
e
o
n
t
h
e
r
ea
r.
5
.
Sc
r
ew the
pa
t
t
r
e
s
s
t
o
t
he
s
u
rfa
ce
u
s
i
n
g
t
he
t
wo
sc
r
ews
a
n
d
plast
i
c
p
l
ug
s
s
u
ppl
i
ed
.
6.
F
i
gure
1
sh
ows
t
h
e
conne
c
t
i
o
n
s
.
C
onne
c
t
t
h
e
i
n
co
m
i
ng
l
ive
,
neutra
l
,
a
nd
in
te
r
connect
(fro
m
o
th
e
r
smo
k
e
a
l
a
r
ms if
p
r
ese
n
t
)
to the pr
e
-
w
i
r
ed
co
nne
c
t
or
b
l
ock
.
T
h
e
P
att
re
s
s
do
es
not
r
eq
u
i
re
a
n
Earth
.
T
he
t
h
re
e
w
ir
es for co
nne
ct
i
n
g
t
o
t
he
s
moke alarm
m
oun
t
ing
p
l
a
t
e are
a
l
ready
wir
ed
t
o
t
h
e
patt
r
ess.
Connect the
r
ed
w
i
re
(
r
emove
t
he
sma
ll
p
ie
c
e
o
f
in
su
l
at
i
ng
t
a
pe
f
ir
st) from
t
h
e
c
ont
r
o
l
pa
ne
l
t
o
t
h
e
t
e
rm
i
n
a
l
m
ark
e
d
"
R
"
and the
ye
ll
ow
w
i
re
t
o
t
he
t
e
r
mi
na
l
m
a
r
ked
"
Y"
.
T
h
e
b
l
a
c
k
and
b
l
ue
w
i
res
fr
om
t
he
control
panel
a
r
e
n
ot
u
sed.
The
y
s
h
o
u
l
d
bothbe
conn
e
ct
ed
t
o
t
h
e
spa
r
e
t
e
r
m
i
na
l
fo
r
e
x
tr
a
stra
i
n
re
li
e
f
.
7
.
Bring
t
he
m
oun
t
i
n
g
p
la
te
w
ire
s
ou
t
t
hr
ou
gh
t
h
e
ho
l
e
i
n
t
h
e
moun
t
ing
p
l
a
te
a
s
s
h
own
i
n
f
i
gu
re 2
.
Co
nn
ect
t
he
t
hree
wi
r
e
s
to the
m
o
un
t
i
ng
p
l
a
t
e
te
r
mi
na
l
s
f
o
l
l
ow
i
ng
t
h
e
w
i
r
i
n
g
c
ol
o
ur
s
sp
e
ci
fie
d in
figu
r
e 2
.
N
o
te
:
T
he
w
hite
interconnect
w
ir
e
must
b
e
co
nn
ected
to the
smo
k
e
a
la
r
m
(
even
i
f
th
ere
i
s
o
n
l
y
on
e
smoke alarm on
t
h
e system).
SMOKE ALARM MOUNTINGPLATE
3
1.
Choo
s
e
t
he
m
o
unting
po
s
it
i
on
f
o
l
low
i
ng the siting
i
ns
t
r
u
c-
t
i
ons inthe Smoke
A
l
arm
leafl
et.
R
e
move
t
h
e power
f
rom the
ci
rcui
t you
pl
an to use.
2. Where the
i
ncomin
g mains and
in
terconnect
w
i
r
e
s
ar
eon
t
he surface of
t
h
e
ceil
i
ng
o
r
w
al
l
the
appropriatel
y
s
i
z
ed duct-
..
ing/condui
tmust
b
e
chos
e
n to mate with the unit.
Figu
r
e
1
NE
UTR
AL
INTER
C
ONN
EC
T
T
O
O
THE
R
S
M
O
KE
/
HE
AT
A
LA
RMS (IF
P
R
ESENT)
TO
C
O
N
TR
OL
PANELEi
1
73
TO EA
Sl
·
F
I
T
SMOK
E
A
L
AR
M
M
OUN
TI
N
G
PLATE
PA
TTR
ESS
WIR
IN
G
The
pa
ttr
ess
i
s usedto mount
t
h
e smoke alarm in
its
loca
t
ion,
t
o connect
i
t to the mains and
inte
r
connect wires, and to con-
nect it to the wires
fr
omthe
E
i
173control
pane
l
.
(The
connec
-
t
i
ons
f
ro
m
thenon-isolated
ma
i
ns poweredsmoke
ala
rm
s,
to
th
e
l
ow
voltage
con
tr
ol
panel
wi
r
es
are
t
h
rough
an
opto
-
i
so
l
ator
in
t
he
E
i
1
7
2/160
for
e
l
ectr
i
ca
l
sa
f
ety).
Note:
Turning
o
ff the power sw
i
t
c
h
on the
Con
tr
o
l
Pane
l
does
n
ot
sw
i
tc
h
o
ff
the
appa
r
atusfrom the
supp
l
y
mains
.
The
sw
i
tch removes the AC and battery power from the Control
Pane
l
,
but the
,
mains
transfo
r
mer remains connected to
t
he
supply ma
in
s.
V
ibration
Pa
d
P
l
ug the
vibra
t
i
on pad
in
t
o
i
ts locking socket on
t
h
e control
pane
l.
P
l
ace the vibration pad underthe pillow or
mattress
.
It
i
s
important
t
hat
th
e
pers
o
n
i
n
th
e bed can
fee
l
t
he
vibrat
i
on
-
check
i
t
i
s
suffic
ie
nt to wake a person by
l
y
in
g on
t
he bed and
press
i
ng
t
h
e
tes
t
butt
on onthe control
pane
l
-
see also ''Test-
i
ng your system". Some mattresses may
no
t
transm
i
t
suffi
-
cient
vi
bration
,
and
i
n
t
hese cases
i
t
shou
l
d befitted
u
nde
r
th
e
pillow.
Note
:
During testing, or
i
n an ac
t
ua
l
alarm
s
i
tuat
i
on,
the pad pulses on and off for
grea
t
er effect on
sleepe
r
s
.
MainsSmoke
Ala
r
m InterfacePattress Ei172/160
The
w
i
re
wh
i
ch is co
l
ou
r
ed
b
l
ue
mus
t be
co
nn
e
cted to
t
he
terminal/w
i
re which
i
s marked
w
i
th the letter
N
or
co
l
ou
r
ed
b
lack.
The
w
ir
e
wh
i
ch is
co
l
oured brown must be connected to the
t
erminal/w
ir
e
wh
i
ch is marked
w
i
th the
l
ett
er
L
o
r
c
o
l
oured
r
ed.
T
he
a
ppara
t
us
i
s
not to be earthed, so no
connect
i
on
i
s
t
o
b
e
made
t
o
termina
l
s or wires marked
w
it
h
the
le
tt
er E,
t
h
e
sym
-
bo
l
Q)
or
co
l
oured green or
g
r
een and
y
el
l
ow
.
B
r
i
ng
t
h
e
l
ow
v
o
l
tage
wir
i
ng
fro
m
th
e
cont
ro
l
panel to
whe
r
e
the smoke
a
l
arm is to be
l
oca
t
ed.
Ro
u
te
a
l
l
wires
neat
l
y and
securely alongthe
wa
ll
s and
ceiling
s.
b
r
own:
live
blu
e
:
n
eu
t
ral
www.acornfiresecurity.com
www.acornfiresecurity.com

6
5
0
m
A
•
Ala
r
m
Control Panel
"
Aux.
Output"
T
h
e
auxil
i
ary
o
u
tp
ut t
urn
s
o
n
w
h
e
n
th
e
co
n
t
ro
l
p
a
n
e
l
i
s
i
n
a
l
a
r
m
and can
s
upply
up
t
o 200
m
A
at
1
2
V
o
l
t
s
(
r
a
n
g
e
1
0
t
o
1
4
Vo
l
t
s
)
.
(No
te:
t
he
p
osit
i
ve
t
e
r
m
ina
l i
s
t
he
p
i
n
n
e
xt
t
o
t
he
"
C
l
oc
k Inpu
t
"
soc
k
e
t
)
.
A
n
Auxiliary
Strob
e Ei 178
i
s
a
vail
ab
l
e
a
n
d
is
su
p
p
li
e
d
w
i
t
h
1
0
m
of
c
able and
a
suita
b
l
e
pl
u
g
.
It
ca
n
b
e
l
o
ca
ted
,
fo
r
e
x
a
m
pl
e
,
w
h
er
e
i
t
is
readily
see
n
du
r
i
n
g
th
e
d
ay
(
e
.g
.
d
ow
n
s
tai
r
s
h
al
l
w
ay)
.
A
n
ex
t
r
a
Vibration Pad Ei 174
i
s
a
v
a
il
a
bl
e
w
i
t
h
2 m
o
f
c
able a
n
d
a
p
l
ug
f
or
connecting
i
t to
th
e
a
u
x
ili
a
ry
so
c
k
e
t.
Cont
r
ol
Pane
l
"Clock
Input
"
socket
A suitable
ala
r
m
c
l
o
c
k
(w
i
th a 5
t
o
2
4
Vo
l
ts
A
C
o
r
D
C
outpu
t
-
electrically isola
te
d
f
r
o
m
t
h
e
ma
i
n
s
s
u
p
ply
)
c
a
n
b
e
co
n
n
e
ct
e
d
to
this input socket
w
i
th a
3
.
5
m
m
mo
n
o
j
a
c
k
p
lu
g
.
Whe
n
th
e
a
lar
m
clock
t
r
igger
s
,
t
he
v
i
b
r
ati
on
p
ad
t
u
rn
s on to w
a
ke
t
he
p
e
r
s
on
,
bu
t
the
i
n
ternal
st
rob
e or
a
u
x
ilia
ry
out
pu
t
d
o
no
t
t
u
rn
o
n
.T
h
i
s
l
e
t
s
t
he
user know
it
is
a
w
a
ke-up
ca
ll
an
d
n
o
t a
fi
r
e
.
Th
e
r
e
fo
r
e
th
e
us
er
nee
d
s
only one
v
i
br
a
ti
o
n
pa
d
un
de
r
th
ei
r
p
ill
ow
o
r
ma
tt
r
ess
.
Trigger
i
ng Control Panel into
A
l
arm Externally
A manual fire
al
a
r
m
s
wi
t
c
h
(
e.g. a
g
l
as
s
br
e
a
k
t
ype)
c
an be
us
ed
to get the control
p
a
ne
l
t
o
t
u
rn
o
n
th
e
v
i
b
ra
t
i
o
n
pad
an
d
s
t
ro
be
lig
h
t.
Th
i
s
is
don
e
b
y
co
nn
ec
t
i
ng
t
h
e
r
ed a
n
d
y
e
l
l
o
w w
i
r
es,
fr
om
t
h
e
contro
l
panel
,
tog
e
t
h
er,
wi
t
h
th
e
sw
i
t
c
h
(
or
v
o
l
t
-fr
ee
re
l
ay
i
s
o
l
ated
cont
a
cts)
.
The w
i
r
e
s
fr
o
m
t
h
e
swi
tch
ca
n
b
e
c
o
n
n
e
c
t
e
d
int
o
th
e
ci
r
-
cui
t at the
patt
r
e
s
s
te
r
m
i
n
a
l
s
.
Note:
Th
i
s does
n
ot
ca
us
e
th
e
sm
o
k
e
a
lar
m
t
o
so
u
n
d.
Adding an Ei 128R Pattress
with
relay
to
the system
The
Ei
128R
Pa
t
t
r
ess is
u
s
e
d
w
he
r
e
v
ol
t
-fre
e
r
e
l
a
y
co
n
ta
c
t
s
are
r
eq
ui
red to signal to
ot
h
er
e
qu
i
p
me
n
t w
h
e
n
o
n
e of
t
h
e
s
mo
k
e
a
l
arms
s
ens
e fire.
Fo
r
e
xa
mp
le
t
h
e
r
e
l
a
y
c
a
n
b
e
u
sed
t
o sig
n
a
l
to a
wa
r
den call
sy
s
te
m
,
o
r
t
o
tu
rn
o
n
l
i
g
h
t
s
.
This
require
s
t
he
s
ys
t
e
m
t
o
h
av
e
a
t
l
e
a
s
t
t
w
o
s
mok
e
/
h
e
at
alarm
s
.
The first
smo
k
e
/
he
at
al
a
r
m
sh
ou
l
d
be
mo
u
n
t
e
d
o
n
t
h
e
pattress
Ei
172/1
60
a
s
des
c
r
i
bed a
bo
v
e
.
Th
e
s
e
co
nd
s
mo
ke
I
h
eat
a
l
arm
,
interco
n
nec
ted
t
o
th
e
fi
r
s
t,
s
h
ou
l
d
b
e
mo
un
t
e
d
o
n
t
h
e
r
e
l
ay
pattress
Ei
128R.
W
he
n
an
y
s
m
oke
a
l
a
r
m
s
e
n
s
es
f
i
r
e
th
e
E
i
172
/
160 pattress
wi
ll
s
i
g
n
a
l
t
h
e
c
o
n
~
o
l
pa
n
e
l
int
o
a
larm
a
n
d
t
h
e
E
i
128R pattress will
s
w
i
t
c
h i
t
s
r
e
l
a
y
con
ta
ct
s
.
(Note: The Ei
1
28R
w
i
ll
n
o
t
op
e
rat
e
wi
t
h
out a
230
V
A
C
m
a
i
ns
supply)
.
Pow
e
r
Req
uirements
The
t
y
p
i
c
al
cur
r
e
n
t
s
a
t
2
3
0
V
AC
ar
e
•
S
t
andby
10
m
A
4
.
Accessories and other Features
T
here are
n
o
u
se
r
s
erv
i
ceab
l
e parts
i
n
t
h
i
s
un
i
t.
I
f
i
t
i
s
t
h
o
u
ght
to be
defective
,
it
mus
t
b
e
r
e
tu
rn
e
d
to
t
h
e
m
a
nuf
act
ur
e
r
f
o
r
r
e-
pair o
r
repla
cem
en
t
(
s
ee
"
P
ro
d
uc
t
G
ua
r
ant
ee
"
sect
i
o
n)
.
T
h
e
c
ontr
ol
p
ane
l
mo
n
i
to
r
s
t
h
e w
iri
ng
t
o
th
e
v
i
b
r
a
t
io
n
pa
d
and the
smok
e a
l
a
r
m
patt
r
ess
fo
r
f
au
lts
.
(
i) If
th
e vib
ra
t
i
o
n
pad
i
s
r
e
m
o
ve
d
o
r
if
i
t
s
w
i
r
i
n
g
i
s
ope
n ci
r
-
c
uit,
t
h
e control
p
an
e
l
will
fl
a
s
h
t
h
e
s
t
r
obe
.
(
ii)
I
f
t
h
e
w
i
r
i
ng
t
o
t
h
e
sm
o
k
e
ala
r
m
pa
tt
r
ess
i
s
d
i
sc
o
nn
e
c
t
ed
,
open
c
ir
cuited o
r
s
h
o
rt
c
i
r
c
ui
t
e
d
,
th
e
c
o
n
t
ro
l
p
a
n
e
l
wi
ll
t
u
rn
o
n
the
v
i
bration pad and
th
e
s
t
robe
li
g
h
t.
no
t o
n
,
ch
eck
t
h
e w
i
r
i
n
g to
t
h
e
m
a
i
n
s
a
nd
t
h
a
t
t
h
e
ma
i
ns
i
s
no
t
o
ff (e.g. due
t
o a
tri
pped
c
i
r
c
ui
t
b
r
e
a
k
e
r
o
r
f
u
s
e
)
.
Ch
ec
k
t
h
e
p
ow
e
r
s
w
i
tc
h
on
t
h
e
c
on
tro
l
p
a
n
e
l
js
o
n
.
3. Troubleshooting
If the units fail any of the
abov
e tests after
installation
,
the
sys
tem has probably been
in
corre
c
tly wired
and
/o
r
all units
are not
connected
.
Check all wiring carefully. If the
gree
n
power lights on the
smok
e alarm and/or the
c
ontrol panel
ar
e
5
(i) Ensure the control panel has been mains powered for at
l
e
ast the previous 20 hours for the battery to
charge
.
(ii)
Turn off the mains power to the control panel by unplug-
ging
it
or switching
off
the circuit at the distribution
board
.
Check that the green light goes off
a
nd the red
li
ght
s
t
arts to
f
lash.
(
iii)
Press
t
he control panel test button for 20 seconds and
check the strobe
f
l
ashes brightly and that the pad vibrates
strongly. Check that the red light
con
t
inues to flash
wh
i
le
t
h
e
test
bu
tton is
pressed
.
(Cover the strobe light with a card to
stop this
daz
z
ling you while looking
for
the red
light)
.
This red
light flashing
indicate
s that the
b
attery is
satisfactory
.
Ifthe
re
d
light g
o
es off, or if the
s
trob
e
i
s weak, or if the vibration
i
s weak,
the
batt
ery will need to be
r
eplaced. Contact the
nea
r
est ad-
dress in
th
is
l
eaflet for advice
abou
t getting a replacement.
Replace Ei173 control
pan
e
l
after 5 years operation. (See
date on
s
ide of
pan
e
l)
.
We
recommend that
th
e
functi
o
ning of the rechargeable
battery is checked at least yearly as
follows
:
After
Installat
i
on
1.
Tu
rn on the AC mains power
t
o the smoke alarm circuit.
Check the continuous green light
i
s visible on the smoke alarm
cover. Ttie red light on the un
i
t will flash every 40
s
e
co
n
ds
.
2.
P
l
ug in the control panel mains
adapto
r (or turn on the AC
mains if
i
t
i
s connected
t
o a
j
unc
t
ion box). Slide
t
he power
switch on the side of
t
he unit
t
o the "on" position.
Chec
k the
con
t
inuous green light on the control panel cover is visible.
3
.
Press the test button on the smoke
alarm
.
The smoke
ala
r
m should sound and the red light
wi
l
l
flash
e
very second.
Aft
e
r
about 4 seconds the control panel will start flashing the
strobe light and the
vibrat
i
on pad will turn on. Two people
ma
y
be needed for
t
h
is test. Interconnected smoke alarms (where
present) should also be
test
ed in
s
i
milar fashion.
4.
Press the control panel test button. Check the
vibra
t
ion
pad is on and
tha
t the strobe is
flashing
.
Daily
&
Weekly Testing
We recommend that you
tes
t your system weekly by press-
ing all
th
e smoke/heat alarm test buttons and
check
i
ng
tha
t
.
the
vibra
t
ion pad and strobe
l
ight
a
r
e operating. Also check at
t
h
e
sa
m
e
t
i
me
t
h
at
t
h
e green
p
owe
r
li
ghts are
v
isibl
e on
b
oth
the smoke alarm(s) and the control panel.
Check
daily
that the vibration pad is in its
correc
t
pos
i
tion by
pressing the
tes
t button on the control panel.
Periodic Testing
of
Rechargeable Battery
The
rechargeable battery takes about 20 hours to charge
from the control panel when it is first powered up. The panel
then maintains it in the
fu
l
ly charged state by continuous
trickle
charge
.
In the event of a mains failure the battery will
power the system in standby for a week followed by at least 4
m
i
nutes
alarm
.
When the mains
fails
,
the
g
r
een light is extin-
guished and the red light flashes rapidly on the control panel to
indicate
it
is on battery power.
If
the battery is starting to be
fully depleted the red light will go off to indicate the control
panel is totally unpowered. The battery will last 5 years in no
r
-
mal use provided it is not exposed to extremes of temperature
for
prolonged periods, or fully discharged/charged a large
number of
times
.
2.
Testing
your
System
www.acornfiresecurity.com
www.acornfiresecurity.com
This manual suits for next models
2
Other Aico Security System manuals
Popular Security System manuals by other brands

Defender
Defender AL00035 manual

Channel Safety Systems
Channel Safety Systems Zerio Plus instruction manual

Clas Ohlson
Clas Ohlson SST-14 instruction manual

DUCATI Performance
DUCATI Performance 96680503A manual

Optex
Optex VX-402 installation instructions

Nokia